{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T07:15:35Z","timestamp":1761894935631},"reference-count":18,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2010,3]]},"abstract":"<jats:sec>\n<jats:title>Object<\/jats:title>\n<jats:p>The authors conducted a study to evaluate the advantages of a 3D volume-rendering technique (VRT) in follow-up digital subtraction (DS) angiography of coil-embolized intracranial aneurysms.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>One hundred nine patients with 121 intracranial aneurysms underwent endovascular coil embolization and at least 1 follow-up DS angiography session at the authors' institution. Two neuroradiologists independently evaluated the conventional 2D DS angiograms, rotational angiograms, and 3D VRT images obtained at the interventional procedures and DS angiography follow-up. If multiple follow-up sessions were performed, the final follow-up was mainly considered. The authors compared the 3 techniques for their ability to detect aneurysm remnants (including aneurysm neck and sac remnants) and parent artery stenosis based on the angiographic follow-up. The Kruskal-Wallis test was used for group comparisons, and the kappa test was used to measure interobserver agreement. Statistical analyses were performed using commercially available software.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>There was a high statistical significance among 2D DS angiography, rotational angiography, and 3D VRT results (X<jats:sup>2<\/jats:sup> = 9.9613, p = 0.0069) when detecting an aneurysm remnant. Further comparisons disclosed a statistical significance between 3D VRT and rotational angiography (X<jats:sup>2<\/jats:sup> = 4.9754, p = 0.0257); a high statistical significance between 3D VRT and 2D DS angiography (X<jats:sup>2<\/jats:sup> = 8.9169, p = 0.0028); and no significant difference between rotational angiography and 2D DS angiography (X<jats:sup>2<\/jats:sup> = 0.5648, p = 0.4523). There was no statistical significance among the 3 techniques when detecting parent artery stenosis (X<jats:sup>2<\/jats:sup> = 2.5164, p = 0.2842). One case, in which parent artery stenosis was diagnosed by 2D DS angiography and rotational angiography, was excluded by 3D VRT following observations of multiple views. The kappa test showed good agreement between the 2 observers.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>The 3D VRT is more sensitive in detecting aneurysm remnants than 2D DS angiography and rotational angiography and is helpful for identifying parent artery stenosis. The authors recommend this technique for the angiographic follow-up of patients with coil-embolized aneurysms.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2009.7.jns081718","type":"journal-article","created":{"date-parts":[[2009,8,7]],"date-time":"2009-08-07T12:12:58Z","timestamp":1249647178000},"page":"674-680","source":"Crossref","is-referenced-by-count":14,"title":["Three-dimensional volume-rendering technique in the angiographic follow-up of intracranial aneurysms embolized with coils"],"prefix":"10.3171","volume":"112","author":[{"given":"Bing","family":"Zhou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming-Hua","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao-Wen","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong-De","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jue","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1-1120674","series-title":"Radiology","first-page":"799","article-title":"Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment","volume":"218","author":"Anxionnat","year":"2001"},{"key":"b2-1120674","series-title":"J Neuroradiol","first-page":"251","article-title":"3D angiography. Clinical interest. First applications in interventional neuroradiology","volume":"25","author":"Anxionnat","year":"1998"},{"key":"b3-1120674","series-title":"J Comput Assist Tomogr","first-page":"216","article-title":"Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils","volume":"23","author":"Brunereau","year":"1999"},{"key":"b4-1120674","series-title":"Neurosurgery","first-page":"1191","article-title":"Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3-6-mo) follow-up","volume":"56","author":"Fiorella","year":"2005"},{"key":"b5-1120674","series-title":"Neuroradiology","first-page":"41","article-title":"Recanalization after endovascular treatment of intracerebral aneurysms","volume":"49","author":"Grunwald","year":"2007"},{"key":"b6-1120674","series-title":"AJNR Am J Neuroradiol","first-page":"1356","article-title":"Computational replicas: anatomic reconstructions of cerebral vessels as volume numerical grids at threedimensional angiography","volume":"25","author":"Hassan","year":"2004"},{"key":"b7-1120674","series-title":"AJNR Am J Neuroradiol","first-page":"1067","article-title":"Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms","volume":"24","author":"Hirai","year":"2003"},{"key":"b8-1120674","series-title":"AJNR Am J Neuroradiol","first-page":"1199","article-title":"Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms","volume":"23","author":"Hochmuth","year":"2002"},{"key":"b9-1120674","series-title":"J Neurosurg","first-page":"538","article-title":"Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms","volume":"91","author":"Lanzino","year":"1999"},{"key":"b10-1120674","series-title":"Ann Biomed Eng","first-page":"460","article-title":"Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity","volume":"25","author":"Lieber","year":"1997"},{"key":"b11-1120674","series-title":"Surg Neurol","first-page":"158","article-title":"Safety of intracranial endovascular aneurysm therapy using 3-dimensional rotational angiography: a single-center experience","volume":"69","author":"Loh","year":"2008"},{"key":"b12-1120674","series-title":"Neurosurgery","first-page":"E416","article-title":"Histological postmortem study of an internal carotid artery aneurysm treated with the Neuroform stent","volume":"56","author":"Lopes","year":"2005"},{"key":"b13-1120674","series-title":"Neuroradiology","first-page":"404","article-title":"CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms: an experimental study","volume":"45","author":"Piotin","year":"2003"},{"key":"b14-1120674","series-title":"Surg Neurol","first-page":"32","article-title":"Angiography after aneurysm surgery: indications for \u201cselective\u201d angiography","volume":"49","author":"Rauzzino","year":"1998"},{"key":"b15-1120674","series-title":"Stroke","first-page":"1398","article-title":"Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils","volume":"34","author":"Raymond","year":"2003"},{"key":"b16-1120674","series-title":"Acta Neurochir (Wien)","first-page":"1153","article-title":"Aneurysmal remnants after microsurgical clipping: classification and results from a prospective angiographic study (in a consecutive series of 305 operated intracranial aneurysms)","volume":"140","author":"Sindou","year":"1998"},{"key":"b17-1120674","series-title":"Neuroradiology","first-page":"383","article-title":"Three-dimensional time-offlight MR angiography at 3T compared to digital subtraction angiography in the follow-up of ruptured and coiled intracranial aneurysms: a prospective study","volume":"50","author":"Urbach","year":"2008"},{"key":"b18-1120674","series-title":"Neuroradiology","first-page":"622","article-title":"Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils","volume":"47","author":"Westerlaan","year":"2005"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/112\/3\/article-p674.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/112\/3\/article-p674.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/112\/3\/article-p674.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T08:43:35Z","timestamp":1679906615000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/112\/3\/article-p674.xml"}},"subtitle":["Clinical article"],"short-title":[],"issued":{"date-parts":[[2010,3]]},"references-count":18,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2009.7.jns081718","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,3]]}}}