{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T15:22:09Z","timestamp":1794324129364,"version":"4.9.0"},"reference-count":40,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2009,12]]},"abstract":"<jats:p>Bilateral pedicle fractures in the spine are uncommon in the absence of bony abnormality, previous surgery, or trauma. The authors report a case of spontaneous bilateral lumbar pedicle fracture in a 50-year-old sedentary woman, which caused intractable pain and did not respond to months of conservative management. The fractures were surgically treated using a percutaneous, minimally invasive technique with screws placed directly through the fractures into the vertebral body. The pedicles were strategically tapped to achieve the lag effect and reapproximate the posterior fragment with the anterior elements. The patient tolerated the procedure well and experienced early improvement of her symptoms, and follow-up imaging showed evidence of fracture healing. Transpedicular fixation and the use of the lag effect could be a useful strategy in the treatment of future cases involving poorly healing pedicle fractures causing persistent symptoms.<\/jats:p>","DOI":"10.3171\/2009.7.spine08373","type":"journal-article","created":{"date-parts":[[2011,2,23]],"date-time":"2011-02-23T16:42:35Z","timestamp":1298479355000},"page":"724-728","source":"Crossref","is-referenced-by-count":14,"title":["Stress fracture of the lumbar pedicle bilaterally: surgical repair using a percutaneous minimally invasive technique"],"prefix":"10.3171","volume":"11","author":[{"given":"Jeremiah N.","family":"Johnson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael Y.","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-0110724","series-title":"Skeletal Radiol","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1007\/BF00350578","article-title":"Jogger's fracture and other stress fractures of the lumbo-sacral spine","volume":"13","author":"Abel","year":"1985"},{"key":"b2-0110724","series-title":"J Bone Joint Surg Am","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.2106\/00004623-198668090-00025","article-title":"Fracture of the pedicle of the fourth lumbar vertebra associated with contralateral spondylolysis. Report of a case","volume":"68","author":"Aland","year":"1986"},{"key":"b3-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1097\/00007632-199211000-00028","article-title":"Reactive sclerosis of the pedicle associated with contralateral spondylolysis","volume":"17","author":"Araki","year":"1992"},{"key":"b4-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1444","DOI":"10.1097\/00007632-200207010-00014","article-title":"Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery","volume":"27","author":"Bose","year":"2002"},{"key":"b5-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2780","DOI":"10.1097\/00007632-199412150-00008","article-title":"Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Initial clinical results","volume":"19","author":"Calancie","year":"1994"},{"key":"b6-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1097\/00007632-198003000-00011","article-title":"Articular tropism and stability of the lumbar spine","volume":"5","author":"Cyron","year":"1980"},{"key":"b7-0110724","series-title":"J Bone Joint Surg Br","first-page":"234","article-title":"The fatigue strength of the lumbar neural arch in spondylolysis","volume":"60","author":"Cyron","year":"1978"},{"key":"b8-0110724","series-title":"J Bone Joint Surg Br","first-page":"462","article-title":"Spondylolytic fractures","volume":"58","author":"Cyron","year":"1976"},{"key":"b9-0110724","series-title":"J Spinal Disord","first-page":"8","article-title":"Evaluation of pedicle screw insertion monitored by intraoperative evoked electromyography","volume":"9","author":"Darden","year":"1996"},{"key":"b10-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"S184","DOI":"10.1097\/00007632-199206001-00021","article-title":"Complications of lumbar spinal fusion with transpedicular instrumentation","volume":"17","author":"Davne","year":"1992"},{"key":"b11-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2724","DOI":"10.1097\/01.brs.0000244618.06877.cd","article-title":"Back pain prevalence and visit rates: estimates from U.S. national surveys, 2002","volume":"31","author":"Deyo","year":"2006"},{"key":"b12-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1097\/00007632-199311000-00015","article-title":"Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members","volume":"18","author":"Esses","year":"1993"},{"key":"b13-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1097\/00007632-198601000-00018","article-title":"Unilateral spondylolysis and contralateral pedicle fracture","volume":"11","author":"Garber","year":"1986"},{"key":"b14-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1097\/00007632-199520120-00008","article-title":"A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation","volume":"20","author":"Glassman","year":"1995"},{"key":"b15-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2541","DOI":"10.1097\/00007632-200010010-00019","article-title":"Contralateral spondylolysis and fracture of the lumbar pedicle in an elite female gymnast: a case report","volume":"25","author":"Guillodo","year":"2000"},{"key":"b16-0110724","series-title":"Spine","first-page":"185","article-title":"Stress fracture of the lumbar pedicle. Case reports of \u201cpediculolysis\u201d and review of the literature","volume":"16","author":"Gunzburg","year":"1991"},{"key":"b17-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"E158","DOI":"10.1097\/01.BRS.0000058951.16468.24","article-title":"Bilateral pedicle stress fracture after instrumented posterolateral lumbar fusion: a case report","volume":"28","author":"Ha","year":"2003"},{"key":"b18-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1097\/00007632-199207000-00023","article-title":"Idiopathic scoliosis with unusual stress fracture of the pedicle within solid fusion mass. A case report","volume":"17","author":"Knight","year":"1992"},{"key":"b19-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"E111","DOI":"10.1097\/01.brs.0000254048.79024.8b","article-title":"Pedicle screw placement accuracy: a meta-analysis","volume":"32","author":"Kosmopoulos","year":"2007"},{"key":"b20-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1097\/00007632-199507150-00006","article-title":"Triggered electromyographic threshold for accuracy of pedicle screw placement. An animal model and clinical correlation","volume":"20","author":"Lenke","year":"1995"},{"key":"b21-0110724","series-title":"J Bone Joint Surg Am","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","article-title":"Complications associated with pedicle screws","volume":"81","author":"Lonstein","year":"1999"},{"key":"b22-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1097\/00007632-200103010-00026","article-title":"Pedicle fracture after instrumented posterolateral lumbar fusion: a case report","volume":"26","author":"Macdessi","year":"2001"},{"key":"b23-0110724","series-title":"J Oral Maxillofac Surg","doi-asserted-by":"publisher","first-page":"2012","DOI":"10.1016\/j.joms.2008.06.013","article-title":"A biomechanical evaluation of plating techniques used for reconstructing mandibular symphysis\/parasymphysis fractures","volume":"66","author":"Madsen","year":"2008"},{"key":"b24-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"E475","DOI":"10.1097\/BRS.0b013e31811ec2bb","article-title":"Biomechanical comparison of a fully threaded, variable pitch screw and a partially threaded lag screw for internal fixation of Type II dens fractures","volume":"32","author":"Magee","year":"2007"},{"key":"b25-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1097\/00007632-200004010-00022","article-title":"Iatrogenic spondylolysis leading to contralateral pedicular stress fracture and unstable spondylolisthesis: a case report","volume":"25","author":"Maurer","year":"2000"},{"key":"b26-0110724","series-title":"Int Orthop","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1007\/s00264-006-0216-6","article-title":"Less is more: lag screw only fixation of lateral malleolar fractures","volume":"31","author":"McKenna","year":"2007"},{"key":"b27-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"E19","DOI":"10.1097\/01.BRS.0000105988.43472.2B","article-title":"Bilateral pedicle stress fractures in a female athlete: case report and review of the literature","volume":"29","author":"Parvataneni","year":"2004"},{"issue":"4 Suppl","key":"b28-0110724","series-title":"Neurosurgery","first-page":"ONS361","article-title":"Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine","volume":"59","author":"Ringel","year":"2006"},{"key":"b29-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1097\/00007632-199306000-00021","article-title":"Stress fracture of the pedicle. A late complication of posterolateral lumbar fusion","volume":"18","author":"Robertson","year":"1993"},{"issue":"Suppl 5","key":"b30-0110724","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1007\/s00586-006-0184-y","article-title":"Bilateral pedicle stress fracture in the lumbar spine of a sedentary office worker","volume":"15","author":"Sadiq","year":"2006"},{"key":"b31-0110724","series-title":"Am J Sports Med","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1177\/0363546504269035","article-title":"Athletes with unilateral spondylolysis are at risk of stress fracture at the contralateral pedicle and pars interarticularis: a clinical and biomechanical study","volume":"33","author":"Sairyo","year":"2005"},{"issue":"2","key":"b32-0110724","series-title":"Neurosurg Focus","first-page":"E9","article-title":"Stress fracture of the pedicle after extensive decompression and contralateral posterior fusion for lumbar stenosis. Report of three cases","volume":"13","author":"Sheehan","year":"2002"},{"key":"b33-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1097\/00007632-199006000-00032","article-title":"Contralateral pedicle stress fracture. An unusual complication of laminectomy","volume":"15","author":"Stanley","year":"1990"},{"key":"b34-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1160","DOI":"10.1097\/00007632-199307000-00007","article-title":"The variable screw placement spinal fixation system. Report of a prospective study of 250 patients enrolled in Food and Drug Administration clinical trials","volume":"18","author":"Steffee","year":"1993"},{"key":"b35-0110724","series-title":"J Comput Assist Tomogr","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1097\/00004728-199103000-00033","article-title":"Bilateral pedicle stress fractures: SPECT and CT features","volume":"15","author":"Traughber","year":"1991"},{"key":"b36-0110724","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1097\/00007632-199307000-00016","article-title":"Bilateral pedicular stress fractures after successful posterior spinal fusion for adult idiopathic scoliosis","volume":"18","author":"Tribus","year":"1993"},{"issue":"Suppl 3","key":"b37-0110724","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1007\/s00586-007-0396-9","article-title":"Acute L5 pedicle fracture and contralateral spondylolysis in a 12-year-old boy: a case report","volume":"16","author":"Vialle","year":"2007"},{"key":"b38-0110724","series-title":"J Bone Joint Surg Br","first-page":"990","article-title":"Low back pain with fracture of the pedicle and contralateral spondylolysis. A technique of surgical management","volume":"73","author":"Weatherley","year":"1991"},{"key":"b39-0110724","series-title":"Radiology","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1148\/111.3.683","article-title":"The sclerotic pedicle: tumor or pseudotumor?","volume":"111","author":"Wilkinson","year":"1974"},{"key":"b40-0110724","series-title":"J Orthop Trauma","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1097\/00005131-200605000-00013","article-title":"Operative treatment of acute distal femur fractures: systematic review of 2 comparative studies and 45 case series (1989 to 2005)","volume":"20","author":"Zlowodzki","year":"2006"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/11\/6\/article-p724.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/11\/6\/article-p724.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/11\/6\/article-p724.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T17:39:19Z","timestamp":1681580359000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/11\/6\/article-p724.xml"}},"subtitle":["Case report"],"short-title":[],"issued":{"date-parts":[[2009,12]]},"references-count":40,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2009.7.spine08373","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2009,12]]}}}