{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T12:24:56Z","timestamp":1776342296469,"version":"3.51.2"},"reference-count":48,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2011,9]]},"abstract":"<jats:sec>\n<jats:title>Object<\/jats:title>\n<jats:p>Intracranial pressure (ICP) monitors are currently based on fluid-filled, strain gauge, or fiberoptic technology. Capacitive sensors have minimal zero drift and energy requirements, allowing long-term implantation and telemetric interrogation; their application to neurosurgery has only occasionally been reported. The aim of this study was to undertake a preliminary in vitro and in vivo evaluation of a capacitive telemetric implantable ICP monitor.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Four devices were tested in air- and saline-filled pressure chambers; long-term capacitance-pressure curves were obtained. Devices implanted in a gel phantom and in a piglet were placed in a 3-T MR unit to evaluate MR compatibility. Four devices were implanted in a piglet neonatal hydrocephalus model; output was compared with ICP obtained through fluid-filled transduction and a strain-gauge ICP monitor.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The capacitance-pressure relationship was constant over 4 weeks, suggesting minimal zero drift during this period. There were no temperature changes around the monitor. Signal loss at the sensor was minimal in both the phantom and the piglet. Over 114,000 measurements were obtained; the difference between mean capacitive ICP and fluid-transduced ICP was 1.8 \u00b1 1.42 mm Hg. The correlation between ICP from the capacitive sensor and fluid-filled transducer (r = 0.97, p &lt; 0.0001) or strain-gauge monitor (r = 0.99, p &lt; 0.0001) was excellent. In vivo monitoring was restricted to 48 hours due to problems with robustness in the clinical environment.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>This preliminary study demonstrates minimal long-term zero drift in vitro, good MR compatibility, and good correlation with other methods of ICP monitoring in vivo in the short term. Further long-term in vivo study is required.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2011.4.jns101920","type":"journal-article","created":{"date-parts":[[2011,5,27]],"date-time":"2011-05-27T14:16:59Z","timestamp":1306505819000},"page":"561-569","source":"Crossref","is-referenced-by-count":16,"title":["Preliminary evaluation of a novel intraparenchymal capacitive intracranial pressure monitor"],"prefix":"10.3171","volume":"115","author":[{"given":"Kristian","family":"Aquilina","sequence":"first","affiliation":[{"name":"University of Bristol and"},{"name":"Department of Neurosurgery, Frenchay Hospital, Bristol, United Kingdom; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marianne","family":"Thoresen","sequence":"additional","affiliation":[{"name":"University of Bristol and"},{"name":"Institute of Basic Medical Sciences, University of Oslo, Norway"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ela","family":"Chakkarapani","sequence":"additional","affiliation":[{"name":"University of Bristol and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ian K.","family":"Pople","sequence":"additional","affiliation":[{"name":"University of Bristol and"},{"name":"Department of Neurosurgery, Frenchay Hospital, Bristol, United Kingdom; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hugh B.","family":"Coakham","sequence":"additional","affiliation":[{"name":"University of Bristol and"},{"name":"Department of Neurosurgery, Frenchay Hospital, Bristol, United Kingdom; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard J.","family":"Edwards","sequence":"additional","affiliation":[{"name":"University of Bristol and"},{"name":"Department of Neurosurgery, Frenchay Hospital, Bristol, United Kingdom; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"issue":"2 Suppl","key":"b1-jns101920","series-title":"J Neurosurg","first-page":"126","article-title":"A neonatal piglet model of intraventricular hemorrhage and posthemorrhagic ventricular dilation","volume":"107","author":"Aquilina","year":"2007"},{"key":"b2-jns101920","series-title":"J Neurosurg","first-page":"927","article-title":"Prospective study of zero drift in fiberoptic pressure monitors used in clinical practice","volume":"86","author":"Bavetta","year":"1997"},{"key":"b3-jns101920","series-title":"J Neurotrauma","first-page":"449","article-title":"Guidelines for the management of severe head injury","volume":"17","author":"Brain Trauma Foundation. American Association of Neurological Surgeons. Joint Section on Neurotrauma and Critical Care","year":"2000"},{"key":"b4-jns101920","series-title":"Med Biol Eng Comput","first-page":"460","article-title":"Technique for very long-term monitoring of intracranial pressure","volume":"21","author":"Brindley","year":"1983"},{"key":"b5-jns101920","series-title":"Neurosurgery","first-page":"421","article-title":"A clinical evaluation of the Camino subdural screw and ventricular monitoring kits","volume":"26","author":"Chambers","year":"1990"},{"key":"b6-jns101920","series-title":"Neurosurgery","first-page":"866","article-title":"An evaluation of the camino ventricular bolt system in clinical practice","volume":"33","author":"Chambers","year":"1993"},{"key":"b7-jns101920","series-title":"Conf Proc IEEE Eng Med Biol Soc 2007","first-page":"3285","article-title":"Motion artifact reduction in blood pressure signals using adaptive digital filter with a capacitive sensor","author":"Choi","year":"2007"},{"key":"b8-jns101920","series-title":"Neurosurgery","first-page":"1152","article-title":"Multicenter clinical assessment of the Raumedic Neurovent-P intracranial pressure sensor: a report by the BrainIT group","volume":"63","author":"Citerio","year":"2008"},{"key":"b9-jns101920","series-title":"Acta Neurochir (Wien)","first-page":"1221","article-title":"Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by the BrainIT group","volume":"146","author":"Citerio","year":"2004"},{"key":"b10-jns101920","series-title":"IEEE Trans Electron Dev","first-page":"1887","article-title":"Pressure sensitivity in anisotropically etched thin-diaphragm pressure sensors","volume":"26","author":"Clark","year":"1979"},{"key":"b11-jns101920","series-title":"Med Biol Eng Comput","first-page":"525","article-title":"Transducers for foot pressure measurement: survey of recent developments","volume":"33","author":"Cobb","year":"1995"},{"key":"b12-jns101920","series-title":"Surg Neurol","first-page":"287","article-title":"A telemetric pressure sensor for ventricular shunt systems","volume":"11","author":"Cosman","year":"1979"},{"key":"b13-jns101920","series-title":"J Neurosurg","first-page":"482","article-title":"Evaluation of a fiberoptic intracranial pressure monitor","volume":"72","author":"Crutchfield","year":"1990"},{"key":"b14-jns101920","series-title":"Neurosurgery","first-page":"219","article-title":"Laboratory testing of three intracranial pressure microtransducers: technical report","volume":"38","author":"Czosnyka","year":"1996"},{"issue":"5","key":"b15-jns101920","series-title":"Neurosurg Focus","first-page":"E10","article-title":"Intracranial pressure: more than a number","volume":"22","author":"Czosnyka","year":"2007"},{"key":"b16-jns101920","series-title":"Med Prog Technol","first-page":"89","article-title":"Long-term intracranial pressure monitoring","volume":"10","author":"de Jong","year":"1984"},{"key":"b17-jns101920","series-title":"Biotelemetry","first-page":"257","article-title":"Telemetred epidural pressure","volume":"2","author":"de Jong","year":"1975"},{"key":"b18-jns101920","series-title":"ISA Trans","first-page":"19","article-title":"Capacitive blood pressure transducer","volume":"19","author":"Dias","year":"1980"},{"key":"b19-jns101920","series-title":"Acta Neurochir Suppl (Wien)","first-page":"44","article-title":"Clinical evaluation of the Codman microsensor intracranial pressure monitoring system","volume":"71","author":"Fernandes","year":"1998"},{"key":"b20-jns101920","series-title":"IEEE Trans Biomed Eng","first-page":"312","article-title":"A microminiature solid-state capacitive blood pressure transducer with improved sensitivity","volume":"20","author":"Frobenius","year":"1973"},{"key":"b21-jns101920","series-title":"Biotelem Patient Monit","first-page":"88","article-title":"Telemetry of intracranial pressure","volume":"5","author":"Fryer","year":"1978"},{"key":"b22-jns101920","series-title":"Neurosurgery","first-page":"918","article-title":"Monitoring of brain tissue pressure with a fiberoptic device","volume":"31","author":"Gambardella","year":"1992"},{"key":"b23-jns101920","series-title":"Childs Nerv Syst","first-page":"470","article-title":"Intracranial pressure monitoring in children: comparison of external ventricular device with the fiberoptic system","volume":"9","author":"Gambardella","year":"1993"},{"key":"b24-jns101920","series-title":"Acta Neurochir (Wien)","first-page":"435","article-title":"The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases","volume":"148","author":"Gelabert-Gonz\u00e1lez","year":"2006"},{"key":"b25-jns101920","series-title":"IEEE Trans Biomed Eng","first-page":"1374","article-title":"A telemetric pressure sensor system for biomedical applications","volume":"55","author":"Ginggen","year":"2008"},{"key":"b26-jns101920","series-title":"J Neurosci Methods","first-page":"11","article-title":"Evaluation of a microsensor intracranial pressure transducer","volume":"49","author":"Gopinath","year":"1993"},{"key":"b27-jns101920","series-title":"Neurosurgery","first-page":"1137","article-title":"Clinical evaluation of a miniature strain-gauge transducer for monitoring intracranial pressure","volume":"36","author":"Gopinath","year":"1995"},{"key":"b28-jns101920","series-title":"Conf Proc IEEE Eng Med Biol Soc","first-page":"2010","article-title":"Tri-axial plantar pressure sensor: design, calibration and characterization","volume":"3","author":"Heywood","year":"2004"},{"key":"b29-jns101920","series-title":"Heart Lung","first-page":"111","article-title":"Use of fiber-optic pressure transducer for intracranial pressure measurements: a preliminary report","volume":"17","author":"Hollingsworth-Fridlund","year":"1988"},{"key":"b30-jns101920","series-title":"J Neurol Neurosurg Psychiatry","first-page":"154","article-title":"A technique for the investigation of intracranial pressure in man","volume":"29","author":"Hulme","year":"1966"},{"key":"b31-jns101920","series-title":"Neurosurgery","first-page":"693","article-title":"Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system","volume":"56","author":"Koskinen","year":"2005"},{"key":"b32-jns101920","series-title":"J Neurosurg","first-page":"852","article-title":"Long-term testing of an intracranial pressure monitoring device","volume":"93","author":"Kroin","year":"2000"},{"key":"b33-jns101920","series-title":"Neurosurgery","first-page":"1455","article-title":"Clinical evaluation of intraparenchymal Spiegelberg pressure sensor","volume":"52","author":"Lang","year":"2003"},{"key":"b34-jns101920","series-title":"Cardiovasc Intervent Radiol","first-page":"714","article-title":"Telemetric catheter-based pressure sensor for hemodynamic monitoring: experimental experience","volume":"32","author":"Mahnken","year":"2009"},{"key":"b35-jns101920","series-title":"Int J Hyperthermia","first-page":"725","article-title":"Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz","volume":"5","author":"Marchal","year":"1989"},{"key":"b36-jns101920","series-title":"J Neurosurg","first-page":"20","article-title":"The outcome with aggressive treatment in severe head injuries. Part I: the significance of intracranial pressure monitoring","volume":"50","author":"Marshall","year":"1979"},{"key":"b37-jns101920","series-title":"J Neurol Neurosurg Psychiatry","first-page":"82","article-title":"Camino intracranial pressure monitor: prospective study of accuracy and complications","volume":"69","author":"Mart\u00ednez-Ma\u00f1as","year":"2000"},{"key":"b38-jns101920","series-title":"Neurosurgery","first-page":"931","article-title":"A new ventriculoperitoneal shunt with a telemetric intracranial pressure sensor: clinical experience in 94 patients with hydrocephalus","volume":"40","author":"Miyake","year":"1997"},{"key":"b39-jns101920","series-title":"Acta Neurochir (Wien)","first-page":"1113","article-title":"The Camino intracranial pressure device in clinical practice: reliability, handling characteristics and complications","volume":"140","author":"M\u00fcnch","year":"1998"},{"key":"b40-jns101920","series-title":"J Neurosurg","first-page":"159","article-title":"Potential heating caused by intraparenchymal intracranial pressure transducers in a 3-tesla magnetic resonance imaging system using a body radiofrequency resonator: assessment of the Codman MicroSensor Transducer","volume":"109","author":"Newcombe","year":"2008"},{"key":"b41-jns101920","series-title":"J Neurosurg","first-page":"206","article-title":"Continuous monitoring of intracranial pressure with a miniaturized fiberoptic device","volume":"67","author":"Ostrup","year":"1987"},{"key":"b42-jns101920","series-title":"Neurosurgery","first-page":"1158","article-title":"The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies","volume":"49","author":"Piper","year":"2001"},{"key":"b43-jns101920","series-title":"Neurosurgery","first-page":"1142","article-title":"The evaluation of the wave-form analysis capability of a new strain-gauge intracranial pressure Micro-Sensor","volume":"36","author":"Piper","year":"1995"},{"key":"b44-jns101920","series-title":"J Neurotrauma","first-page":"439","article-title":"Fiberoptic intraparenchymal brain pressure monitoring with the Camino V420 monitor: reflections on our experience in 163 severely head-injured patients","volume":"19","author":"Poca","year":"2002"},{"key":"b45-jns101920","series-title":"Sensors Actuators A: Phys","first-page":"93","article-title":"Capacitive sensors: when and how to use them?","volume":"37\u201338","author":"Puers","year":"1993"},{"key":"b46-jns101920","series-title":"J Hand Surg Am","first-page":"67","article-title":"Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results","volume":"32","author":"Rikli","year":"2007"},{"key":"b47-jns101920","series-title":"J Shoulder Elbow Surg","first-page":"462","article-title":"Coracoacromial pressure recordings in a cadaveric model","volume":"4","author":"Wuelker","year":"1995"},{"key":"b48-jns101920","series-title":"J Neurosurg","first-page":"899","article-title":"A pressure-balanced radio-telemetry system for the measurement of intracranial pressure. A preliminary design report","volume":"47","author":"Zervas","year":"1977"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/115\/3\/article-p561.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/115\/3\/article-p561.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/115\/3\/article-p561.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T02:17:57Z","timestamp":1679883477000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/115\/3\/article-p561.xml"}},"subtitle":["Laboratory investigation"],"short-title":[],"issued":{"date-parts":[[2011,9]]},"references-count":48,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2011.4.jns101920","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,9]]}}}