{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T02:59:15Z","timestamp":1783479555528,"version":"3.55.0"},"reference-count":23,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2013,4]]},"abstract":"<jats:sec>\n<jats:title>Object<\/jats:title>\n<jats:p>The aims of this study were to evaluate a large series of posterior C-1 lateral mass screws (LMSs) to determine accuracy based on CT scanning findings and to assess the perioperative complication rate related to errant screw placement.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Accuracy of screw placement was evaluated using postoperative CT scans obtained in 196 patients with atlantoaxial instability. Radiographic analysis included measurement of preoperative and postoperative CT scans to evaluate relevant anatomy and classify accuracy of instrumentation placement. Screws were graded using the following definitions: Type I, screw threads completely within the bone (ideal); Type II, less than half the diameter of the screw violates the surrounding cortex (safe); and Type III, clear violation of transverse foramen or spinal canal (unacceptable).<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>A total of 390 C-1 LMSs were placed, but 32 screws (8.2%) were excluded from accuracy measurements because of a lack of postoperative CT scans; patients in these cases were still included in the assessment of potential clinical complications based on clinical records. Of the 358 evaluable screws with postoperative CT scanning, 85.5% of screws (Type I) were rated as being in the ideal position, 11.7% of screws (Type II) were rated as occupying a safe position, and 10 screws (2.8%) were unacceptable (Type III). Overall, 97.2% of screws were rated Type I or II. Of the 10 screws that were unacceptable on postoperative CT scans, there were no known associated neurological or vertebral artery (VA) injuries. Seven unacceptable screws erred medially into the spinal canal, and 2 patients underwent revision surgery for medial screws. In 2 patients, unilateral C-1 LMSs penetrated the C-1 anterior cortex by approximately 4 mm. Neither patient with anterior C-1 penetration had evidence of internal carotid artery or hypoglossal nerve injury. Computed tomography scanning showed partial entry of C-1 LMSs into the VA foramen of C-1 in 10 cases; no occlusion, associated aneurysm, or fistula of the VA was found. Two patients complained of postoperative occipital neuralgia. This was transient in one patient and resolved by 2 months after surgery. The second patient developed persistent neuralgia, which remained 2 years after surgery, necessitating referral to the pain service.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>The technique for freehand C-1 LMS fixation appears to be safe and effective without intraoperative fluoroscopy guidance. Preoperative planning and determination of the ideal screw insertion point, the ideal trajectory, and screw length are the most important considerations. In addition, fewer malpositioned screws were inserted as the study progressed, suggesting a learning curve to the technique.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2013.1.spine12724","type":"journal-article","created":{"date-parts":[[2013,2,1]],"date-time":"2013-02-01T18:35:44Z","timestamp":1359743744000},"page":"372-377","source":"Crossref","is-referenced-by-count":21,"title":["Accuracy and complications associated with the freehand C-1 lateral mass screw fixation technique: a radiographic and clinical assessment"],"prefix":"10.3171","volume":"18","author":[{"given":"Yong","family":"Hu","sequence":"first","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No. 6 Hospital, Zhejiang Province, China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher K.","family":"Kepler","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Thomas Jefferson University and Rothman Institute, Philadelphia, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Todd J.","family":"Albert","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Thomas Jefferson University and Rothman Institute, Philadelphia, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen-shan","family":"Yuan","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No. 6 Hospital, Zhejiang Province, China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-hu","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No. 6 Hospital, Zhejiang Province, China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong-jie","family":"Gu","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No. 6 Hospital, Zhejiang Province, China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rong-ming","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No. 6 Hospital, Zhejiang Province, China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-spine12724","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"554","DOI":"10.3171\/spi.2006.5.6.554","article-title":"Vertebral artery injury in C-1 lateral mass screw fixation. Case illustration","volume":"5","author":"Aota","year":"2006"},{"key":"b2-spine12724","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"222","DOI":"10.3171\/SPI\/2008\/8\/3\/222","article-title":"Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques","volume":"8","author":"Aryan","year":"2008"},{"key":"b3-spine12724","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.spinee.2012.02.011","article-title":"Accuracy and complications associated with posterior C1 screw fixation techniques: a radiographic and clinical assessment","volume":"12","author":"Bransford","year":"2012"},{"key":"b4-spine12724","series-title":"Neurol India","first-page":"178","article-title":"Vertebral artery in relationship to C1-C2 vertebrae: an anatomical study","volume":"52","author":"Cacciola","year":"2004"},{"key":"b5-spine12724","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1007\/s00586-009-1178-3","article-title":"C1 lateral mass screw-induced occipital neuralgia: a report of two cases","volume":"19","author":"Conroy","year":"2010"},{"key":"b6-spine12724","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1097\/BRS.0b013e318166e083","article-title":"Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra: implications for C1-C2 transarticular and C1 lateral mass fixation","volume":"33","author":"Currier","year":"2008"},{"key":"b7-spine12724","series-title":"Spine J","first-page":"489","article-title":"Lateral mass screw-rod fixation of the cervical spine: a prospective clinical series with 1-year follow-up","volume":"3","author":"Deen","year":"2003"},{"key":"b8-spine12724","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1097\/00006123-200212000-00004","article-title":"Atlantoaxial fixation using plate and screw method: a report of 160 treated patients","volume":"51","author":"Goel","year":"2002"},{"key":"b9-spine12724","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/BF01400872","article-title":"Plate and screw fixation for atlanto-axial dislocations","volume":"129","author":"Goel","year":"1994"},{"key":"b10-spine12724","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1097\/01.bsd.0000211291.21766.4d","article-title":"The use of C1 lateral mass screws in complex cervical spine surgery: indications, techniques, and outcome in a prospective consecutive series of 25 cases","volume":"20","author":"Gunnarsson","year":"2007"},{"key":"b11-spine12724","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1-C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms","year":"2001"},{"key":"b12-spine12724","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"83","DOI":"10.3171\/spi.2006.5.1.83","article-title":"Hypoglossal nerve palsy after posterior screw placement on the C-1 lateral mass. Case report","volume":"5","author":"Hong","year":"2006"},{"key":"b13-spine12724","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"230","DOI":"10.3171\/SPI\/2008\/8\/3\/230","article-title":"Analysis of anatomical variations of bone and vascular structures around the posterior atlantal arch using three-dimensional computed tomography angiography","volume":"8","author":"Hong","year":"2008"},{"issue":"2 Suppl","key":"b14-spine12724","series-title":"J Neurosurg","first-page":"178","article-title":"Incorporation of C-1 lateral mass screws in occipitocervical and atlantoaxial fusions for children 8 years of age or younger. Technical note","volume":"107","author":"Jea","year":"2007"},{"key":"b15-spine12724","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1097\/BRS.0b013e31816d72b5","article-title":"The feasibility of microscope-assisted \u201cfree-hand\u201d C1 lateral mass screw insertion without fluoroscopy","volume":"33","author":"Liu","year":"2008"},{"key":"b16-spine12724","series-title":"J Neurol Sci","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.jns.2007.05.001","article-title":"Transcranial Doppler ultrasonographic evaluation of vertebral artery hypoplasia and aplasia","volume":"260","author":"Min","year":"2007"},{"key":"b17-spine12724","series-title":"J Comput Assist Tomogr","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1097\/00004728-200205000-00027","article-title":"Normal variation of vertebral artery on CT angiography and its implications for diagnosis of acquired pathology","volume":"26","author":"Sanelli","year":"2002"},{"key":"b18-spine12724","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1227\/01.NEU.0000351779.58845.62","article-title":"Safe zone for C1 lateral mass screws: anatomic and radiological study","volume":"65","author":"Simsek","year":"2009"},{"key":"b19-spine12724","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1097\/BRS.0b013e3181646ba1","article-title":"Outcome-based classification for assessment of thoracic pedicular screw placement","volume":"33","author":"Upendra","year":"2008"},{"issue":"3B","key":"b20-spine12724","series-title":"Arq Neuropsiquiatr","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1590\/S0004-282X2006000500012","article-title":"C1 lateral mass screws for posterior segmental stabilization of the upper cervical spine and a new method of three-point rigid fixation of the C1-C2 complex","volume":"64","author":"Vilela","year":"2006"},{"key":"b21-spine12724","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1097\/BRS.0b013e3181c97dc7","article-title":"Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases","volume":"36","author":"Wang","year":"2011"},{"key":"b22-spine12724","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1016\/j.spinee.2009.02.008","article-title":"Lateral fluoroscopic guide to prevent occipitocervical and atlantoaxial joint violation during C1 lateral mass screw placement","volume":"9","author":"Yeom","year":"2009"},{"key":"b23-spine12724","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E942","DOI":"10.1097\/BRS.0b013e3181870441","article-title":"Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement","volume":"33","author":"Yeom","year":"2008"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/18\/4\/article-p372.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/18\/4\/article-p372.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/18\/4\/article-p372.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,16]],"date-time":"2023-04-16T00:23:05Z","timestamp":1681604585000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/18\/4\/article-p372.xml"}},"subtitle":["Clinical article"],"short-title":[],"issued":{"date-parts":[[2013,4]]},"references-count":23,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3171\/2013.1.spine12724","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2013,4]]}}}