{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T15:22:53Z","timestamp":1794324173679,"version":"4.9.0"},"reference-count":24,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2013,9]]},"abstract":"<jats:sec>\n                    <jats:title>Object<\/jats:title>\n                    <jats:p>Carotid artery stenting (CAS) can be an alternative option for carotid endarterectomy in the prevention of ischemic stroke caused by carotid artery stenosis. The purpose of this study was to evaluate the influence of stent design on the incidence of procedural and postprocedural embolism associated with CAS treatment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Ninety-six symptomatic and asymptomatic patients, consisting of 79 males and 17 females, with moderate to severe carotid artery stenosis and a mean age of 69.0 years were treated with CAS. The stent type (48 closed-cell and 48 open-cell stents) was randomly allocated before the procedure. Imaging, procedural, and clinical outcomes were assessed and compared. The symptomatic subgroup (76 patients) was also analyzed to determine the influence of stent design on outcome.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>New lesions on postprocedural diffusion-weighted imaging (DWI) were significantly more frequent in the open-cell than in the closed-cell stent group (24 vs 12, respectively; p = 0.020). The 30-day clinical outcome was not different between the 2 stent groups. In the symptomatic patient group, stent design (p = 0.017, OR 4.173) and recent smoking history (p = 0.036, OR 4.755) were strong risk factors for new lesions on postprocedural DWI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Stent design may have an influence on the risk of new embolism, and selecting the appropriate stent may improve outcome.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2013.5.jns1331","type":"journal-article","created":{"date-parts":[[2013,6,21]],"date-time":"2013-06-21T10:30:49Z","timestamp":1371810649000},"page":"642-647","source":"Crossref","is-referenced-by-count":48,"title":["Incidence of embolism associated with carotid artery stenting: open-cell versus closed-cell stents"],"prefix":"10.3171","volume":"119","author":[{"given":"Keun Young","family":"Park","sequence":"first","affiliation":[{"name":"Departments of Radiology and"},{"name":"Department of Neurosurgery, National Health Insurance Corporation Ilsan Hospital, Goyang-si, Gyeonggi-do, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Ik","family":"Kim","sequence":"additional","affiliation":[{"name":"Departments of Radiology and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byung Moon","family":"Kim","sequence":"additional","affiliation":[{"name":"Departments of Radiology and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyo Suk","family":"Nam","sequence":"additional","affiliation":[{"name":"Neurology, Yonsei University College of Medicine, Seoul; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Dae","family":"Kim","sequence":"additional","affiliation":[{"name":"Neurology, Yonsei University College of Medicine, Seoul; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Hoe","family":"Heo","sequence":"additional","affiliation":[{"name":"Neurology, Yonsei University College of Medicine, Seoul; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Joon","family":"Kim","sequence":"additional","affiliation":[{"name":"Departments of Radiology and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-jns1331","series-title":"Catheter Cardiovasc Interv","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/ccd.22439","article-title":"Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial","volume":"76","author":"Ansel","year":"2010"},{"key":"b2-jns1331","series-title":"N Engl J Med","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1056\/NEJM199811123392002","article-title":"Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis","volume":"339","author":"Barnett","year":"1998"},{"key":"b3-jns1331","series-title":"Eur J Vasc Endovasc Surg","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.ejvs.2006.09.019","article-title":"Does free cell area influence the outcome in carotid artery stenting?","volume":"33","author":"Bosiers","year":"2007"},{"key":"b4-jns1331","series-title":"N Engl J Med","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1056\/NEJMoa0912321","article-title":"Stenting versus endarterectomy for treatment of carotid-artery stenosis","volume":"363","author":"Brott","year":"2010"},{"key":"b5-jns1331","series-title":"J Vasc Surg","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1016\/j.jvs.2006.06.029","article-title":"Do device characteristics impact outcome in carotid artery stenting?","volume":"44","author":"Hart","year":"2006"},{"key":"b6-jns1331","series-title":"Ann Vasc Surg","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.avsg.2010.07.004","article-title":"Closed-cell stents present with higher velocities on duplex ultrasound compared with open-cell stents after carotid intervention: short- and mid-term results","volume":"25","author":"Hussain","year":"2011"},{"key":"b7-jns1331","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1161\/STROKEAHA.108.534289","article-title":"Protection or nonprotection in carotid stent angioplasty: the influence of interventional techniques on outcome data from the SPACE Trial","volume":"40","author":"Jansen","year":"2009"},{"key":"b8-jns1331","series-title":"Endovascular and Percutaneous Therapy of the Brain and Spine","first-page":"1","article-title":"Ischemic stroke: overview","author":"Kidwell","year":"2002"},{"key":"b9-jns1331","series-title":"AJNR Am J Neuroradiol","first-page":"151","article-title":"Spontaneous improvement of persistent ulceration after carotid artery stenting","volume":"27","author":"Kohyama","year":"2006"},{"key":"b10-jns1331","series-title":"JAMA","doi-asserted-by":"publisher","first-page":"3289","DOI":"10.1001\/jama.1991.03470230047029","article-title":"Carotid endarterectomy and prevention of cerebral ischemia in symptomatic carotid stenosis. Veterans Affairs Cooperative Studies Program 309 Trialist Group","volume":"266","author":"Mayberg","year":"1991"},{"key":"b11-jns1331","series-title":"Catheter Cardiovasc Interv","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1002\/ccd.22503","article-title":"Carotid artery stenting in octogenarians using a proximal endovascular occlusion cerebral protection device: a multicenter registry","volume":"76","author":"Micari","year":"2010"},{"key":"b12-jns1331","series-title":"Neuroradiology","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1007\/s00234-011-0867-x","article-title":"Unprotected carotid artery stenting: complications in 6 months follow-up","volume":"54","author":"Mohammadian","year":"2012"},{"key":"b13-jns1331","series-title":"J Endovasc Ther","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1583\/08-2539.1","article-title":"Comparison of carotid stents: an invitro experiment focusing on stent design","volume":"16","author":"M\u00fcller-H\u00fclsbeck","year":"2009"},{"key":"b14-jns1331","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1161\/STROKEAHA.110.588772","article-title":"Anatomical and technical factors associated with stroke or death during carotid angioplasty and stenting: results from the endarterectomy versus angioplasty in patients with symptomatic severe carotid stenosis (EVA-3S) trial and systematic review","volume":"42","author":"Naggara","year":"2011"},{"key":"b15-jns1331","series-title":"J Vasc Surg","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1016\/j.jvs.2008.10.016","article-title":"Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting","volume":"49","author":"Pierce","year":"2009"},{"key":"b16-jns1331","series-title":"J Endovasc Ther","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1583\/04-1400MR.1","article-title":"Proximal endovascular flow blockage for cerebral protection during carotid artery stenting: results from a prospective multicenter registry","volume":"12","author":"Reimers","year":"2005"},{"key":"b17-jns1331","series-title":"Eur J Radiol","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1016\/j.ejrad.2007.04.007","article-title":"Morphological changes of ulcerative plaque in patients received carotid angioplasty and stenting (CAS)","volume":"65","author":"Sadikin","year":"2008"},{"key":"b18-jns1331","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1161\/STROKEAHA.107.499145","article-title":"Does carotid stent cell design matter?","volume":"39","author":"Schillinger","year":"2008"},{"key":"b19-jns1331","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.1161\/STROKEAHA.107.500603","article-title":"New brain lesions after carotid stenting versus carotid endarterectomy: a systematic review of the literature","volume":"39","author":"Schnaudigel","year":"2008"},{"key":"b20-jns1331","series-title":"J Endovasc Ther","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1583\/08-2583.1","article-title":"Clinical significance and technical assessment of stent cell geometry in carotid artery stenting","volume":"16","author":"Siewiorek","year":"2009"},{"key":"b21-jns1331","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"1962","DOI":"10.1161\/STROKEAHA.110.607820","article-title":"Are distal protection devices \u2018protective\u2019 during carotid angioplasty and stenting?","volume":"42","author":"Tallarita","year":"2011"},{"key":"b22-jns1331","series-title":"AJNR Am J Neuroradiol","first-page":"604","article-title":"Conformity of carotid stents with vascular anatomy: evaluation in carotid models","volume":"25","author":"Tanaka","year":"2004"},{"key":"b23-jns1331","series-title":"Neuroradiology","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1007\/s00234-010-0672-y","article-title":"Complication rate in unprotected carotid artery stenting with closed-cell stents","volume":"52","author":"Tietke","year":"2010"},{"key":"b24-jns1331","series-title":"J Vasc Surg","first-page":"1310.e1","article-title":"Randomized clinical trial of open-cell vs closed-cell stents for carotid stenting and effects of stent design on cerebral embolization","volume":"54","author":"Timaran","year":"2011"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/119\/3\/article-p642.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/119\/3\/article-p642.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/119\/3\/article-p642.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,14]],"date-time":"2022-08-14T13:05:30Z","timestamp":1660482330000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/119\/3\/article-p642.xml"}},"subtitle":["Clinical article"],"short-title":[],"issued":{"date-parts":[[2013,9]]},"references-count":24,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2013.5.jns1331","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9]]}}}