{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T13:46:08Z","timestamp":1792676768940,"version":"4.5.0"},"reference-count":11,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2015,3]]},"abstract":"<jats:sec>\n<jats:title>OBJECT<\/jats:title>\n<jats:p>The authors prospectively analyzed 2 microscope-integrated videoangiography techniques using intravenous indocyanine green (ICG) and fluorescein for assessment of cerebral aneurysm obliteration and adjacent vessel patency.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>METHODS<\/jats:title>\n<jats:p>The authors prospectively enrolled 22 patients who underwent clip ligation of their aneurysm and used intraoperative videoangiography to assess obliteration of the aneurysmal sac and patency of the adjacent branching and perforating arteries. Patients underwent ICG videoangiography (ICG-VA) and the newly developed fluorescein videoangiography (FL-VA) using microscope-integrated fluorescence modules. Two independent observers compared the videoangiography recordings for value and quality to assess aneurysm exclusion and the patency of adjacent arteries.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>RESULTS<\/jats:title>\n<jats:p>All 22 patients first underwent FL-VA and then ICG-VA after clip application. In 7 cases (32%), FL-VA provided superior detail to assess perforating arteries (4 cases), distal branches (2 cases), and both (1 case); such detail was not readily available on ICG-VA. In 1 patient, ICG-VA offered better visualization of posterior communicating artery aneurysm occlusion than FL-VA because of staining artifact on the aneurysm dome from the adjacent tentorium. In 2 patients, FL-VA offered the needed advantage of real-time manipulation of the vessels and flow assessment by visualization through the operating microscope oculars. In 2 other cases, ICG-VA was more practical for repeat usage because of its more efficient clearance from the intravascular space. The ICG-VA image quality was often degraded at higher magnification in deep operative fields, partly due to chromatic aberration. Both ICG-VA and FL-VA afforded restricted views of vasculature based on the angle of surgical approach and obscuration by blood clot, aneurysm, or brain tissue.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>CONCLUSIONS<\/jats:title>\n<jats:p>Compared with ICG-VA, FL-VA can potentially provide an improved visualization of vasculature at high magnification in deep surgical fields. ICG-VA is more effective for repeated use during clip repositioning due to ICG's minimal vascular wall extravasation. Therefore, in certain cases, FL-VA may offer some advantages and play a complementary role along with ICG-VA in intraoperative fluorescence evaluation during microsurgical management of aneurysms.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2014.10.jns132766","type":"journal-article","created":{"date-parts":[[2014,12,19]],"date-time":"2014-12-19T15:03:33Z","timestamp":1419001413000},"page":"618-626","source":"Crossref","is-referenced-by-count":52,"title":["A prospective comparative study of microscope-integrated intraoperative fluorescein and indocyanine videoangiography for clip ligation of complex cerebral aneurysms"],"prefix":"10.3171","volume":"122","author":[{"given":"Brandon","family":"Lane","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bradley N.","family":"Bohnstedt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aaron A.","family":"Cohen-Gadol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-jns132766","series-title":"Acta Neurochir Suppl","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/978-3-211-99651-5_39","article-title":"Microscope integrated indocyanine green video-angiography in cerebrovascular surgery","volume":"109","author":"Dashti","year":"2011"},{"key":"b2-jns132766","series-title":"Surg Neurol","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/j.surneu.2009.01.027","article-title":"Microscope-integrated near-infrared indocyanine green videoangiography during surgery of intracranial aneurysms: the Helsinki experience","volume":"71","author":"Dashti","year":"2009"},{"key":"b3-jns132766","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1227\/NEU.0b013e31820777ee","article-title":"Prospective comparison of intraoperative vascular monitoring technologies during cerebral aneurysm surgery","volume":"68","author":"Gruber","year":"2011"},{"key":"b4-jns132766","series-title":"International Organization for Standardization","article-title":"Optics and photonics\u2014designation of microscope objectives\u2014Part 2: Chromatic correction","author":"ISO 19012-2:2009"},{"issue":"2 Suppl Operative","key":"b5-jns132766","series-title":"Neurosurgery","first-page":"ons141","article-title":"Intra-arterial injection fluorescein videoangiography in aneurysm surgery","volume":"72","author":"Kuroda","year":"2013"},{"key":"b6-jns132766","series-title":"Neurosurgery","first-page":"132","article-title":"Near-infrared indocyanine green video angiography: a new method for intraoperative assessment of vascular flow","volume":"52","author":"Raabe","year":"2003"},{"key":"b7-jns132766","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"982","DOI":"10.3171\/jns.2005.103.6.0982","article-title":"Prospective evaluation of surgical microscopeintegrated intraoperative near-infrared indocyanine green videoangiography during aneurysm surgery","volume":"103","author":"Raabe","year":"2005"},{"key":"b8-jns132766","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"429","DOI":"10.3171\/JNS\/2008\/108\/2\/0429","article-title":"Fluorescence angiography","volume":"108","author":"Raabe","year":"2008"},{"key":"b9-jns132766","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"68","DOI":"10.3171\/JNS-07\/07\/0068","article-title":"Confirmation of blood flow in perforating arteries using fluorescein cerebral angiography during aneurysm surgery","volume":"107","author":"Suzuki","year":"2007"},{"key":"b10-jns132766","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"420","DOI":"10.3171\/2012.10.JNS11818","article-title":"Comparing indocyanine green videoangiography to the gold standard of intraoperative digital subtraction angiography used in aneurysm surgery","volume":"118","author":"Washington","year":"2013"},{"key":"b11-jns132766","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1227\/00006123-199411000-00027","article-title":"Intraoperative assessment of aneurysm clip placement by intravenous fluorescein angiography","volume":"35","author":"Wrobel","year":"1994"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/122\/3\/article-p618.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/122\/3\/article-p618.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/122\/3\/article-p618.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,24]],"date-time":"2022-07-24T22:56:31Z","timestamp":1658703391000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/122\/3\/article-p618.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3]]},"references-count":11,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2014.10.jns132766","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,3]]}}}