{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T12:05:41Z","timestamp":1787313941783,"version":"build-2736575974"},"reference-count":16,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2015,6]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECT<\/jats:title>\n                    <jats:p>The goal of this study was to determine the value of the 3D sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) technique in the evaluation of endoscopic third ventriculostomy (ETV) patency.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>Twenty-six patients with ETV were examined using 3-T MRI units. Sagittal-plane 3D-SPACE with variant flip-angle mode, 3D T1-weighted (T1W), and 3D heavily T2-weighted (T2W) images were obtained with isotropic voxel sizes. Also, sagittal-axial plane phase-contrast cine (PC)-MR images were obtained. The following findings were evaluated: diameters of stoma and third ventricle, flow-void sign on 3D-SPACE and PC-MR images, integrity of the third ventricle on heavily T2W images, and quantitative PC-MRI parameters of the stoma. Obtained sequences were evaluated singly, in combination with one another, and all together.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>The mean area, flow, and velocity values measured at the level of stoma in patients with patent stoma were significantly higher than those measured in patients with closed stoma (p &lt; 0.05). There was significant correlation among PC-MRI, 3D-SPACE, and 3D heavily T2W techniques regarding assessment of ETV patency (p &lt; 0.001). The 3D-SPACE technique provided the lowest rate of ambiguous results.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>The 3D-SPACE technique seems to be the most efficient one for determination of ETV patency. The authors suggest the use of 3D-SPACE as a stand-alone first-line sequence in addition to routine brain MRI protocols in assessing patients with ETV, thereby decreasing scan time and reserving the use of a combination of additional sequences such as PC-MRI and 3D heavily T2W images in suspicious or complex cases.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2014.10.jns14298","type":"journal-article","created":{"date-parts":[[2015,4,10]],"date-time":"2015-04-10T20:27:01Z","timestamp":1428697621000},"page":"1347-1355","source":"Crossref","is-referenced-by-count":27,"title":["Assessment of third ventriculostomy patency with the 3D-SPACE technique: a preliminary multicenter research study"],"prefix":"10.3171","volume":"122","author":[{"given":"Oktay","family":"Algin","sequence":"first","affiliation":[{"name":"Department of Radiology, Ataturk Training and Research Hospital;"},{"name":"Bilkent University, National MR Research Center (UMRAM), Bilkent, Ankara;\u00a0"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Murat","family":"Ucar","sequence":"additional","affiliation":[{"name":"Departments of Radiology and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evrim","family":"Ozmen","sequence":"additional","affiliation":[{"name":"Department of Radiology, Ataturk Training and Research Hospital;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alp Ozgun","family":"Borcek","sequence":"additional","affiliation":[{"name":"Neurosurgery, Gazi University Medical Faculty;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pinar","family":"Ozisik","sequence":"additional","affiliation":[{"name":"Neurosurgery Clinic, Koru Hospital, Ankara; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gokhan","family":"Ocakoglu","sequence":"additional","affiliation":[{"name":"Biostatistics, Uludag University, Gorukle, Bursa, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E. Turgut","family":"Tali","sequence":"additional","affiliation":[{"name":"Departments of Radiology and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-jns14298","series-title":"Clin Neurol Neurosurg","first-page":"700","article-title":"Radiologic evaluation of spontaneous or endoscopic third ventriculostomy: which technique is more useful?","volume":"113","author":"Algin","year":"2011"},{"key":"b2-jns14298","series-title":"J Neuroradiol","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.neurad.2010.03.006","article-title":"Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography for the detection of spontaneous third ventriculostomy","volume":"38","author":"Algin","year":"2011"},{"key":"b3-jns14298","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3174\/ajnr.A2833","article-title":"Evaluation of aqueductal stenosis by 3D sampling perfection with application-optimized contrasts using different flip angle evolutions sequence: preliminary results with 3T MR imaging","volume":"33","author":"Algin","year":"2012"},{"key":"b4-jns14298","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"14","DOI":"10.3174\/ajnr.A2899","article-title":"Intrathecal gadolinium-enhanced MR cisternography: a comprehensive review","volume":"34","author":"Algin","year":"2013"},{"key":"b5-jns14298","series-title":"J Neuroradiol","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.neurad.2011.12.003","article-title":"Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: preliminary results with variant flip-angle mode","volume":"40","author":"Algin","year":"2013"},{"key":"b6-jns14298","series-title":"AJNR Am J Neuroradiol","first-page":"2514","article-title":"Functional analysis of third ventriculostomy patency by quantification of CSF stroke volume by using cine phase-contrast MR imaging","volume":"26","author":"Bargall\u00f3","year":"2005"},{"key":"b7-jns14298","series-title":"Childs Nerv Syst","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1007\/s00381-008-0779-1","article-title":"Endoscopic third ventriculostomy for malfunction in previously shunted infants","volume":"25","author":"Bilginer","year":"2009"},{"key":"b8-jns14298","series-title":"Can J Neurol Sci","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1017\/S0317167100008179","article-title":"Cine phase-contrast MR images failed to predict clinical outcome following ETV","volume":"36","author":"Di","year":"2009"},{"key":"b9-jns14298","series-title":"Neurosurg Rev","first-page":"1","article-title":"Endoscopic third ventriculostomy for obstructive hydrocephalus","volume":"28","author":"Hellwig","year":"2005"},{"key":"b10-jns14298","series-title":"Eur Radiol","doi-asserted-by":"publisher","first-page":"2789","DOI":"10.1007\/s00330-009-1477-4","article-title":"Brain ventricular wall movement assessed by a gated cine MR trueFISP sequence in patients treated with endoscopic third ventriculostomy","volume":"19","author":"Hodel","year":"2009"},{"key":"b11-jns14298","series-title":"Eur Radiol","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1007\/s00330-012-2732-7","article-title":"Imaging of the entire cerebrospinal fluid volume with a multistation 3D SPACE MR sequence: feasibility study in patients with hydrocephalus","volume":"23","author":"Hodel","year":"2013"},{"key":"b12-jns14298","series-title":"Insights Imaging","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1007\/s13244-014-0333-5","article-title":"Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: an update","volume":"5","author":"Kartal","year":"2014"},{"key":"b13-jns14298","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"931","DOI":"10.3171\/JNS\/2008\/109\/11\/0931","article-title":"Three-dimensional constructive interference in steady-state magnetic resonance imaging in obstructive hydrocephalus: relevance for endoscopic third ventriculostomy and clinical results","volume":"109","author":"Kunz","year":"2008"},{"key":"b14-jns14298","series-title":"Radiology","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1148\/radiology.216.3.r00au46891","article-title":"Optimized single-slab three-dimensional spin-echo MR imaging of the brain","volume":"216","author":"Mugler","year":"2000"},{"key":"b15-jns14298","author":"Mugler"},{"issue":"Suppl 1","key":"b16-jns14298","series-title":"J Neurol Neurosurg Psychiatry","first-page":"i17","article-title":"Hydrocephalus and shunts: what the neurologist should know","volume":"73","author":"Pople","year":"2002"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/122\/6\/article-p1347.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/122\/6\/article-p1347.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/122\/6\/article-p1347.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,24]],"date-time":"2022-07-24T18:07:33Z","timestamp":1658686053000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/122\/6\/article-p1347.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6]]},"references-count":16,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2014.10.jns14298","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,6]]}}}