{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T15:22:55Z","timestamp":1794324175153,"version":"4.9.0"},"reference-count":14,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2015,3]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECT<\/jats:title>\n                    <jats:p>This investigation was done to examine, following implantation of vagus nerve stimulators, the relationship of vocal cord paralysis to the inner diameter of the coils used to attach the stimulator lead to the nerve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>All data in this investigation were collected, as mandated by the FDA, by the manufacturer of vagus nerve stimulators and were made available without restrictions for analysis by the authors. The data reflect all initial device implantations in the United States for the period from 1997 through 2012.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Vocal cord paralysis was reported in 193 of 51,882 implantations. In patients aged 18 years and older, the incidence of paralysis was 0.26% when the stimulator leads had coil diameters of 3 mm and 0.51% when the leads had 2-mm-diameter coils (p &lt; 0.05). Across all age groups, the incidence of vocal cord paralysis increased with age at implantation for leads having 2-mm-diameter coils.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In patients aged 18 years and older, vocal cord paralysis occurred at almost twice the rate with the implantation of vagus nerve stimulator leads having 2-mm-diameter coils than with leads having 3-mm-diameter coils. The incidence of vocal cord paralysis increases with patient age at implantation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2014.10.jns14640","type":"journal-article","created":{"date-parts":[[2014,12,19]],"date-time":"2014-12-19T10:03:33Z","timestamp":1418983413000},"page":"532-535","source":"Crossref","is-referenced-by-count":14,"title":["Relationship of vocal cord paralysis to the coil diameter of vagus nerve stimulator leads"],"prefix":"10.3171","volume":"122","author":[{"given":"Leslie C.","family":"Robinson","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, University of Colorado School of Medicine, Aurora;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken R.","family":"Winston","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Colorado School of Medicine, Aurora;"},{"name":"Denver Health and Hospitals, Denver;"},{"name":"University Hospital; and"},{"name":"Children's Hospital Colorado, Aurora, Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-jns14640","series-title":"Seizure","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1016\/j.seizure.2006.06.002","article-title":"Long-term results with vagus nerve stimulation in children with pharmacoresistant epilepsy","volume":"15","author":"Alexopoulos","year":"2006"},{"key":"b2-jns14640","series-title":"J Clin Neurophysiol","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1097\/00004691-200109000-00005","article-title":"Vagus nerve stimulation, side effects, and long-term safety","volume":"18","author":"Ben-Menachem","year":"2001"},{"key":"b3-jns14640","series-title":"Neurology","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1212\/WNL.51.1.48","article-title":"Vagus nerve stimulation therapy for partial-onset seizures: a randomized active-control trial","volume":"51","author":"Handforth","year":"1998"},{"key":"b4-jns14640","series-title":"Seizure","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/j.seizure.2013.06.011","article-title":"Complications of vagal nerve stimulation for drug-resistant epilepsy: a single center longitudinal study of 143 patients","volume":"22","author":"Kahlow","year":"2013"},{"key":"b5-jns14640","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"949","DOI":"10.3171\/jns.2002.96.5.0949","article-title":"Self-inflicted vocal cord paralysis in patients with vagus nerve stimulators. Report of two cases","volume":"96","author":"Kalkanis","year":"2002"},{"key":"b6-jns14640","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"26","DOI":"10.3171\/jns.1993.78.1.0026","article-title":"Vagus nerve stimulation for complex partial seizures: surgical technique, safety, and efficacy","volume":"78","author":"Landy","year":"1993"},{"key":"b7-jns14640","series-title":"J Neurol Neurosurg Psychiatry","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1136\/jnnp.2009.179929","article-title":"Refractory central supratentorial hiccup partially relieved with vagus nerve stimulation","volume":"81","author":"Longatti","year":"2010"},{"key":"b8-jns14640","series-title":"Neurotherapeutics","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.nurt.2007.10.071","article-title":"Vagus nerve stimulation for epilepsy and depression","volume":"5","author":"Milby","year":"2008"},{"key":"b9-jns14640","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"935","DOI":"10.3171\/jns.2005.102.5.0935","article-title":"Vagus nerve stimulation for chronic intractable hiccups. Case report","volume":"102","author":"Payne","year":"2005"},{"key":"b10-jns14640","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"500","DOI":"10.3171\/jns.2003.99.3.0500","article-title":"Complications of chronic vagus nerve stimulation for epilepsy in children","volume":"99","author":"Smyth","year":"2003"},{"key":"b11-jns14640","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"829","DOI":"10.3171\/2009.6.JNS09422","article-title":"Insulation discontinuity in a vagus nerve stimulator lead: a treatable cause of intolerable stimulation-related symptoms","volume":"112","author":"Spitz","year":"2010"},{"key":"b12-jns14640","series-title":"Tohoku J Exp Med","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1620\/tjem.216.133","article-title":"Nonrecurrent inferior laryngeal nerve without vascular anomaly as a genuine entity","volume":"216","author":"Tateda","year":"2008"},{"key":"b13-jns14640","series-title":"J Neurol Sci","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.jns.2011.02.022","article-title":"Lead breakage and vocal cord paralysis following blunt neck trauma in a patient with vagal nerve stimulator","volume":"304","author":"Tran","year":"2011"},{"key":"b14-jns14640","series-title":"Neurology","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1212\/WNL.45.2.224","article-title":"A randomized controlled trial of chronic vagus nerve stimulation for treatment of medically intractable seizures","volume":"45","author":"Vagus Nerve Stimulation Study Group","year":"1995"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/122\/3\/article-p532.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/122\/3\/article-p532.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/122\/3\/article-p532.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,24]],"date-time":"2022-07-24T18:55:29Z","timestamp":1658688929000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/122\/3\/article-p532.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3]]},"references-count":14,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2014.10.jns14640","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,3]]}}}