{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T03:13:04Z","timestamp":1794453184070,"version":"4.9.1"},"reference-count":51,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2015,4]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECT<\/jats:title>\n                    <jats:p>Percutaneous pedicle screws are used to provide rigid internal fixation in minimally invasive spinal procedures and generally require the use of Kirchner wires (or K-wires) as a guide for screw insertion. K-wires can bend, break, advance, or pull out during the steps of pedicle preparation and screw insertion. This can lead to increased fluoroscopic and surgical times and potentially cause neurological, vascular, or visceral injury. The authors present their experience with a novel \u201cK-wireless\u201d percutaneous pedicle screw system that eliminates the inherent risks of K-wire use.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>A total of 100 screws were placed in 28 patients using the K-wireless percutaneous screw system. Postoperative dedicated spinal CT scans were performed in 25 patients to assess the accuracy of screw placement. Screw placement was graded A through D by 2 independent radiologists: A = within pedicle, B = breach &lt; 2 mm, C = breach of 2\u20134 mm, and D = breach &gt; 4 mm. Screw insertion and fluoroscopy times were also recorded in each case. Clinical complications associated with screw insertion were documented.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>A total of 100 K-wireless percutaneous pedicle screws were placed into the lumbosacral spine in 28 patients. Postoperative CT was performed in 25 patients, thus the placement of only 90 screws was assessed. Eighty-seven screws were placed within the pedicle confines (Grade A), and 3 violated the pedicle (2 Grade B [1 lateral, 1 medial] and 1 Grade D [medial]) for an overall accuracy rate of 96.7%. One patient required reoperation for screw repositioning due to a postoperative L-5 radiculopathy secondary to a Grade D medial breach at L-5. This patient experienced improvement of the radiculopathy after reoperation. Average screw insertion and fluoroscopy times were 6.92 minutes and 22.7 seconds per screw, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>The results of this study demonstrate that the placement of K-wireless percutaneous pedicle screws is technically feasible and can be performed accurately and safely with short procedure and fluoroscopy times.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2014.11.spine14181","type":"journal-article","created":{"date-parts":[[2015,2,6]],"date-time":"2015-02-06T10:02:12Z","timestamp":1423216932000},"page":"422-431","source":"Crossref","is-referenced-by-count":41,"title":["Percutaneous \u201cK-wireless\u201d pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time"],"prefix":"10.3171","volume":"22","author":[{"given":"Steven M.","family":"Spitz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Faheem A.","family":"Sandhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Marc","family":"Voyadzis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-spine14181","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1097\/BSD.0b013e318211fdea","article-title":"Optimization of radiation exposure and image quality of the cone-beam O-arm intraoperative imaging system in spinal surgery","volume":"25","author":"Abul-Kasim","year":"2012"},{"key":"b2-spine14181","series-title":"Orthopade","first-page":"693","article-title":"[Transpedicular implantation of screws in the thoracolumbar spine. Results of a survey of methods, frequency and complications]","volume":"28","author":"Bastian","year":"1999"},{"key":"b3-spine14181","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"570","DOI":"10.3171\/SPI.2008.4.08182","article-title":"Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion","volume":"9","author":"Bindal","year":"2008"},{"key":"b4-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1097\/00007632-199606010-00008","article-title":"Accuracy of pedicle screw placement in lumbar vertebrae","volume":"21","author":"Castro","year":"1996"},{"key":"b5-spine14181","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1097\/00006123-200010000-00017","article-title":"Computer-assisted fluoroscopic targeting system for pedicle screw insertion","volume":"47","author":"Choi","year":"2000"},{"key":"b6-spine14181","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1227\/01.NEU.0000124751.57121.A6","article-title":"Back pain and disability after lumbar laminectomy: is there a relationship to muscle retraction?","volume":"54","author":"Datta","year":"2004"},{"key":"b7-spine14181","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1097\/BSD.0b013e31805fea01","article-title":"Minimally invasive transpedicular vertebrectomy for metastatic disease to the thoracic spine","volume":"21","author":"Deutsch","year":"2008"},{"key":"b8-spine14181","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"560","DOI":"10.3171\/SPI.2008.9.08142","article-title":"Clinical and radiographic comparison of mini-open transforaminal lumbar interbody fusion with open transforaminal lumbar interbody fusion in 42 patients with long-term follow-up","volume":"9","author":"Dhall","year":"2008"},{"issue":"15 Suppl","key":"b9-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S26","DOI":"10.1097\/01.BRS.0000076895.52418.5E","article-title":"Minimally invasive lumbar fusion","volume":"28","author":"Foley","year":"2003"},{"key":"b10-spine14181","series-title":"Acta Orthop Scand","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1080\/00016470410004102","article-title":"Computer-assisted fluoroscopic navigation of pedicle screw insertion: an in vivo feasibility study","volume":"75","author":"Fu","year":"2004"},{"key":"b11-spine14181","series-title":"J Bone Joint Surg Am","first-page":"1458","article-title":"The use of pedicle-screw internal fixation for the operative treatment of spinal disorders","volume":"82-A","author":"Gaines","year":"2000"},{"key":"b12-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1097\/00007632-199905150-00017","article-title":"Serial changes in trunk muscle performance after posterior lumbar surgery","volume":"24","author":"Gejo","year":"1999"},{"key":"b13-spine14181","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"Gelalis","year":"2012"},{"key":"b14-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein","year":"1990"},{"key":"b15-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1097\/00007632-200202150-00021","article-title":"A minimally invasive technique for decompression of the lumbar spine","volume":"27","author":"Guiot","year":"2002"},{"key":"b16-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2226","DOI":"10.1097\/00007632-199810150-00017","article-title":"Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report","volume":"23","author":"Heini","year":"1998"},{"issue":"3","key":"b17-spine14181","series-title":"Neurosurg Focus","first-page":"E6","article-title":"Minimally invasive transforaminal lumbar interbody fusion: indications, technique, and complications","volume":"20","author":"Holly","year":"2006"},{"key":"b18-spine14181","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"98","DOI":"10.3171\/spi.2005.3.2.0098","article-title":"Minimally invasive microendoscopy-assisted transforaminal lumbar interbody fusion with instrumentation","volume":"3","author":"Isaacs","year":"2005"},{"issue":"304","key":"b19-spine14181","series-title":"Clin Orthop Relat Res","first-page":"130","article-title":"Percutaneous diagnostic stabilization for low back pain. Correlation with results after fusion operations","author":"Jeanneret","year":"1994"},{"key":"b20-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1097\/00007632-199604150-00007","article-title":"Back muscle injury after posterior lumbar spine surgery. A histologic and enzymatic analysis","volume":"21","author":"Kawaguchi","year":"1996"},{"key":"b21-spine14181","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1016\/j.spinee.2006.12.012","article-title":"Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery","volume":"8","author":"Kim","year":"2008"},{"key":"b22-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E111","DOI":"10.1097\/01.brs.0000254048.79024.8b","article-title":"Pedicle screw placement accuracy: a meta-analysis","volume":"32","author":"Kosmopoulos","year":"2007"},{"key":"b23-spine14181","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s005860000146","article-title":"Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients","volume":"9","author":"Laine","year":"2000"},{"key":"b24-spine14181","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1007\/BF01834068","article-title":"Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients","volume":"6","author":"Laine","year":"1997"},{"issue":"Suppl 1","key":"b25-spine14181","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"S126","DOI":"10.1007\/PL00008318","article-title":"Posterior percutaneous spine instrumentation","volume":"9","author":"Lowery","year":"2000"},{"issue":"189","key":"b26-spine14181","series-title":"Clin Orthop Relat Res","first-page":"125","article-title":"Stabilization of the lower thoracic and lumbar spine with external skeletal fixation","author":"Magerl","year":"1984"},{"key":"b27-spine14181","series-title":"Proc Inst Mech Eng H","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1243\/09544119JEIM268","article-title":"Fluoroscopy-based navigation system in spine surgery","volume":"221","author":"Merloz","year":"2007"},{"key":"b28-spine14181","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1097\/BSD.0b013e3182999380","article-title":"Raley DA: Complications with K-wire insertion for percutaneous pedicle screws","volume":"27","author":"Mobbs","year":"2014"},{"key":"b29-spine14181","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1097\/BSD.0b013e3181eed618","article-title":"Radiation exposure to the surgeon during percutaneous pedicle screw placement","volume":"24","author":"Mroz","year":"2011"},{"key":"b30-spine14181","series-title":"Int J Med Robot","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1002\/rcs.359","article-title":"Three-dimensional image-guided placement of percutaneous pedicle screws without the use of biplanar fluoroscopy or Kirschner wires: technical note","volume":"6","author":"Nottmeier","year":"2010"},{"issue":"1","key":"b31-spine14181","series-title":"Neurosurg Focus","first-page":"E4","article-title":"Bilateral decompressive surgery in lumbar spinal stenosis associated with spondylolisthesis: unilateral approach and use of a microscope and tubular retractor system","volume":"13","author":"Palmer","year":"2002"},{"key":"b32-spine14181","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1097\/BSD.0b013e318250ec75","article-title":"Percutaneous lumbar and thoracic pedicle screws: a trauma experience","volume":"27","author":"Park","year":"2014"},{"issue":"2","key":"b33-spine14181","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E16","DOI":"10.3171\/FOC\/2008\/25\/8\/E16","article-title":"Minimally invasive transforaminal lumbar interbody fusion with reduction of spondylolisthesis: technique and outcomes after a minimum of 2 years' follow-up","volume":"25","author":"Park","year":"2008"},{"key":"b34-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1097\/01.brs.0000256473.49791.f4","article-title":"Comparison of one-level posterior lumbar interbody fusion performed with a minimally invasive approach or a traditional open approach","volume":"32","author":"Park","year":"2007"},{"key":"b35-spine14181","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1227\/NEU.0b013e3181fdfaf4","article-title":"Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws","volume":"68","author":"Parker","year":"2011"},{"issue":"3","key":"b36-spine14181","series-title":"Neurosurg Focus","first-page":"E3","article-title":"Placement of percutaneous pedicle screws without imaging guidance","volume":"20","author":"Powers","year":"2006"},{"key":"b37-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2637","DOI":"10.1097\/00007632-200010150-00016","article-title":"Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion","volume":"25","author":"Rampersaud","year":"2000"},{"key":"b38-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1097\/BRS.0b013e3181cbfd09","article-title":"Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws","volume":"36","author":"Ravi","year":"2011"},{"issue":"4 Suppl 2","key":"b39-spine14181","series-title":"Neurosurgery","first-page":"ONS361","article-title":"Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine","volume":"59","author":"Ringel","year":"2006"},{"issue":"203","key":"b40-spine14181","series-title":"Clin Orthop Relat Res","first-page":"7","article-title":"Internal fixation of the lumbar spine with pedicle screw plating","author":"Roy-Camille","year":"1986"},{"issue":"4 Suppl 2","key":"b41-spine14181","series-title":"Neurosurgery","first-page":"203","article-title":"Percutaneous transforaminal lumbar interbody fusion for the treatment of degenerative lumbar instability","volume":"60","author":"Scheufler","year":"2007"},{"key":"b42-spine14181","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1007\/s00586-006-0221-x","article-title":"Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization","volume":"16","author":"Schizas","year":"2007"},{"key":"b43-spine14181","series-title":"J Spinal Disord Tech","first-page":"S1","article-title":"Minimally invasive transforaminal lumbar interbody fusion (TLIF): technical feasibility and initial results","volume":"18 Suppl","author":"Schwender","year":"2005"},{"key":"b44-spine14181","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1097\/BSD.0b013e31826226cb","article-title":"Incidence of lumbar spine pedicle breach after percutaneous screw fixation: a radiographic evaluation of 601 screws in 151 patients","volume":"27","author":"Smith","year":"2014"},{"issue":"1 Suppl","key":"b45-spine14181","series-title":"Neurosurgery","first-page":"ONS52","article-title":"Minimally invasive resection of intraduralextramedullary spinal neoplasms","volume":"58","author":"Tredway","year":"2006"},{"key":"b46-spine14181","series-title":"Semin Spine Surg","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1053\/j.semss.2010.11.003","article-title":"The learning curve in minimally invasive spine surgery","volume":"23","author":"Voyadzis","year":"2011"},{"key":"b47-spine14181","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"600","DOI":"10.3171\/2010.5.SPINE09536","article-title":"Stimulus-evoked electromyography testing of percutaneous pedicle screws for the detection of pedicle breaches: a clinical study of 409 screws in 93 patients","volume":"13","author":"Wang","year":"2010"},{"key":"b48-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1599","DOI":"10.1097\/00007632-199908010-00015","article-title":"Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine","volume":"24","author":"Wiesner","year":"1999"},{"key":"b49-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1097\/00007632-200003010-00013","article-title":"Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine","volume":"25","author":"Wiesner","year":"2000"},{"key":"b50-spine14181","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1097\/00007632-198813060-00019","article-title":"New uses and refinements of the paraspinal approach to the lumbar spine","volume":"13","author":"Wiltse","year":"1988"},{"key":"b51-spine14181","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1227\/00006123-198811000-00014","article-title":"Relief of lumbar canal stenosis using multilevel subarticular fenestrations as an alternative to wide laminectomy: preliminary report","volume":"23","author":"Young","year":"1988"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/22\/4\/article-p422.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/22\/4\/article-p422.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/22\/4\/article-p422.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T17:26:54Z","timestamp":1681579614000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/22\/4\/article-p422.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4]]},"references-count":51,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3171\/2014.11.spine14181","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2015,4]]}}}