{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T06:27:24Z","timestamp":1763620044603},"reference-count":22,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2014,9]]},"abstract":"<jats:sec>\n<jats:title>Object<\/jats:title>\n<jats:p>Cerebrovascular lesions can have complicated abnormal anatomy that is not completely characterized by CT or MR angiography. Although 3D rotational angiography provides superior spatial and temporal resolution, catheter angiograms are not easily registered to the patient, limiting the use of these images as a source for neuronavigation. However, 3D digital subtraction angiography (DSA) contains not only vascular anatomy but also facial surface anatomy data. The authors report a novel technique to register 3D DSA images by using only the surface anatomy contained within the data set without having to fuse the DSA image set to other imaging modalities or use fiducial markers.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>A cadaver model was first created to assess the accuracy of neuronavigation based on 3D DSA images registered by facial surface anatomy. A 3D DSA scan was obtained of a formalin-fixed cadaver head, with acquisitions of mask and contrast runs. The right common carotid artery was injected prior to the contrast run with a 45% contrast solution diluted with water-soluble red liquid latex. One week later, the head was registered to a neuronavigation system loaded with the 3D DSA images acquired earlier using facial surface anatomy. A right pterional craniotomy was performed and 10 different vascular landmarks were identified and measured for accuracy using the neuronavigation system. Neuronavigation based only on 3D DSA was then used to guide an open clipping procedure for a patient who presented with a ruptured distal lenticulostriate aneurysm.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The accuracy of the measurements for the cadaver model was 0.71 \u00b1 0.25 mm (mean \u00b1 SE), which is superior to the 1.8\u20135 mm reported for neuronavigation. The 3D DSA\u2013based navigation-assisted surgery for the distal lenticulostriate aneurysm aided in localization, resulting in a small craniotomy and minimal brain dissection.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>This is the first example of frameless neuronavigation based on 3D catheter angiography registered by only the surface anatomy data contained within the 3D DSA image set. This is an easily applied technique that is beneficial for accurately locating vascular pathological entities and reducing the dissection burden of vascular lesions.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2014.6.jns132386","type":"journal-article","created":{"date-parts":[[2014,7,18]],"date-time":"2014-07-18T14:02:21Z","timestamp":1405692141000},"page":"745-750","source":"Crossref","is-referenced-by-count":14,"title":["Frameless neuronavigation based only on 3D digital subtraction angiography using surface-based facial registration"],"prefix":"10.3171","volume":"121","author":[{"given":"David A.","family":"Stidd","sequence":"first","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua","family":"Wewel","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali J.","family":"Ghods","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephan","family":"Munich","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anthony","family":"Serici","sequence":"additional","affiliation":[{"name":"Anatomy and Cell Biology, Rush University Medical Center, Chicago; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiffon M.","family":"Keigher","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heike","family":"Theessen","sequence":"additional","affiliation":[{"name":"Siemens Healthcare Sector, Hoffman Estates, Illinois"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roham","family":"Moftakhar","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Demetrius K.","family":"Lopes","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1-jns132386","series-title":"Radiology","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1148\/radiology.218.3.r01mr09799","article-title":"Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment","volume":"218","author":"Anxionnat","year":"2001"},{"key":"b2-jns132386","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1227\/00006123-198706000-00019","article-title":"Computed imaging stereotaxy: experience and perspective related to 500 procedures applied to brain masses","volume":"20","author":"Apuzzo","year":"1987"},{"issue":"3 Suppl","key":"b3-jns132386","series-title":"Neurosurgery","first-page":"55","article-title":"Real-time image guidance for open vascular neurosurgery using digital angiographic roadmapping","volume":"61","author":"Ayad","year":"2007"},{"key":"b4-jns132386","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1227\/01.NEU.0000372205.53792.E4","article-title":"Image-guided resection of embolized cerebral arteriovenous malformations based on catheter-based angiography","volume":"67","author":"Gonzalez","year":"2010"},{"key":"b5-jns132386","series-title":"AJNR Am J Neuroradiol","first-page":"1199","article-title":"Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms","volume":"23","author":"Hochmuth","year":"2002"},{"issue":"3 Suppl 1","key":"b6-jns132386","series-title":"Neurosurgery","first-page":"266","article-title":"Dynact soft-tissue visualization using an angiographic C-arm system: initial clinical experience in the operating room","volume":"62","author":"Irie","year":"2008"},{"key":"b7-jns132386","series-title":"Minim Invasive Neurosurg","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1055\/s-2007-985151","article-title":"Neuronavigation-assisted surgery for distal anterior cerebral artery aneurysm","volume":"50","author":"Kim","year":"2007"},{"key":"b8-jns132386","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1227\/NEU.0b013e31820b4f1c","article-title":"Robotic digital subtraction angiography systems within the hybrid operating room","volume":"68","author":"Murayama","year":"2011"},{"key":"b9-jns132386","series-title":"Neurol Res","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1179\/016164104225016056","article-title":"Magnetic resonance angiography image guidance for the microsurgical clipping of intracranial aneurysms: a report of two cases","volume":"26","author":"Pirotte","year":"2004"},{"key":"b10-jns132386","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"406","DOI":"10.3171\/jns.2006.105.3.406","article-title":"Three-dimensional rotational angiography guidance for aneurysm surgery","volume":"105","author":"Raabe","year":"2006"},{"key":"b11-jns132386","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"545","DOI":"10.3171\/jns.1986.65.4.0545","article-title":"A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope","volume":"65","author":"Roberts","year":"1986"},{"key":"b12-jns132386","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1108","DOI":"10.1097\/00006123-200211000-00002","article-title":"Role of frameless stereotaxy in the surgical treatment of cerebral arteriovenous malformations: technique and outcomes in a controlled study of 44 consecutive patients","volume":"51","author":"Russell","year":"2002"},{"key":"b13-jns132386","series-title":"Acta Neurochir Suppl","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/978-3-211-99651-5_18","article-title":"From intraoperative angiography to advanced intraoperative imaging: the geneva experience","volume":"109","author":"Schaller","year":"2011"},{"key":"b14-jns132386","series-title":"Minim Invasive Neurosurg","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1055\/s-2003-44455","article-title":"Neuronavigation based on CT angiography for surgery of intracranial aneurysms: primary experience with unruptured aneurysms","volume":"46","author":"Schmid-Elsaesser","year":"2003"},{"issue":"5 Suppl 2","key":"b15-jns132386","series-title":"Neurosurgery","first-page":"266","article-title":"Image-guided surgery for treatment of unruptured middle cerebral artery aneurysms","volume":"61","author":"Son","year":"2007"},{"key":"b16-jns132386","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1227\/NEU.0b013e318287072d","article-title":"The silent loss of neuronavigation accuracy: a systematic retrospective analysis of factors influencing the mismatch of frameless stereotactic systems in cranial neurosurgery","volume":"72","author":"Stieglitz","year":"2013"},{"key":"b17-jns132386","series-title":"AJNR Am J Neuroradiol","first-page":"1545","article-title":"Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms","volume":"23","author":"Sugahara","year":"2002"},{"key":"b18-jns132386","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1007\/s00701-012-1363-8","article-title":"Surgical treatment of poorly visualised and complex cerebrovascular lesions using pre-operative angiographic data as angiographic DynaCT datasets for frameless stereotactic navigation","volume":"154","author":"Tee","year":"2012"},{"key":"b19-jns132386","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"976","DOI":"10.3174\/ajnr.A0964","article-title":"3D rotational angiography: the new gold standard in the detection of additional intracranial aneurysms","volume":"29","author":"van Rooij","year":"2008"},{"key":"b20-jns132386","series-title":"Semin Ophthalmol","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1080\/08820530801978534","article-title":"Management of intracranial aneurysm causing a third cranial nerve palsy: MRA, CTA or DSA?","volume":"23","author":"Vaphiades","year":"2008"},{"key":"b21-jns132386","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"501","DOI":"10.3171\/jns.2007.106.3.501","article-title":"Image-guided vascular neurosurgery based on three-dimensional rotational angiography. Technical note","volume":"106","author":"Willems","year":"2007"},{"key":"b22-jns132386","series-title":"Acad Radiol","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1016\/j.acra.2012.02.012","article-title":"Benefits of 3D rotational DSA compared with 2D DSA in the evaluation of intracranial aneurysm","volume":"19","author":"Wong","year":"2012"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/121\/3\/article-p745.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/121\/3\/article-p745.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/121\/3\/article-p745.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,25]],"date-time":"2022-07-25T01:20:01Z","timestamp":1658712001000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/121\/3\/article-p745.xml"}},"subtitle":["Laboratory investigation"],"short-title":[],"issued":{"date-parts":[[2014,9]]},"references-count":22,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2014.6.jns132386","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9]]}}}