{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T09:05:14Z","timestamp":1780131914824,"version":"3.54.0"},"reference-count":3,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"v1supplement","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["FOC"],"published-print":{"date-parts":[[2014,7]]},"abstract":"<jats:p>\n                    We present the case of a balloon-assisted, stent-supported coil embolization of a basilar tip aneurysm. Initially, a balloon extending from the basilar artery into the right PCA was placed.\n                    <jats:sup>3<\/jats:sup>\n                    However, even with a more proximal purchase, coils were found to impinge on the left PCA. Subsequently, a transcirculation approach was performed, where the left posterior communicating artery was utilized as a conduit for balloon support and the coils were embolized from the ipsilateral vertebral artery.\n                    <jats:sup>1<\/jats:sup>\n                    However, after this transcirculation approach was completed, there was a coil tail extruding from the aneurysm. The balloon was then removed over an exchange wire and a horizontal stent advanced, spanning the entire neck of the aneurysm, eliminating the extruded coil.\n                    <jats:sup>2<\/jats:sup>\n                  <\/jats:p>\n                  <jats:p>\n                    The video can be found here:\n                    <jats:bold>\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"http:\/\/youtu.be\/bMbtZoPnYvo\" ext-link-type=\"uri\" xlink:type=\"simple\">http:\/\/youtu.be\/bMbtZoPnYvo<\/jats:ext-link>\n                      .\n                    <\/jats:bold>\n                  <\/jats:p>","DOI":"10.3171\/2014.v2.focus14182","type":"journal-article","created":{"date-parts":[[2014,7,1]],"date-time":"2014-07-01T11:07:03Z","timestamp":1404212823000},"page":"1","source":"Crossref","is-referenced-by-count":0,"title":["Transcirculation balloon-assisted stent-supported coil embolization of a basilar tip aneurysm"],"prefix":"10.3171","volume":"37","author":[{"given":"Vijay","family":"Agarwal","sequence":"first","affiliation":[{"name":"Division of Neurosurgery, Duke University Medical Center, Durham, North Carolina; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Zomorodi","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Duke University Medical Center, Durham, North Carolina; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cameron","family":"Mcdougal","sequence":"additional","affiliation":[{"name":"Barrow Neurological Institute, Phoenix, Arizona"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranjith","family":"Babu","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Duke University Medical Center, Durham, North Carolina; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam","family":"Back","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Duke University Medical Center, Durham, North Carolina; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. Fernando","family":"Gonzalez","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Duke University Medical Center, Durham, North Carolina; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-10.14182","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1227\/NEU.0b013e3182077f17","article-title":"Transcirculation endovascular treatment of complex cerebral aneurysms: technical considerations and preliminary results","volume":"68","author":"Albuquerque","year":"2011"},{"key":"b2-10.14182","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1227\/NEU.0b013e318265a416","article-title":"Safety and efficacy of endovascular treatment of basilar tip aneurysms by coiling with and without stent assistance: a review of 235 cases","volume":"71","author":"Chalouhi","year":"2012"},{"key":"b3-10.14182","series-title":"AJNR Am J Neuroradiol","first-page":"1987","article-title":"Stent-assisted coiling versus balloon remodeling of wide-neck aneurysms: comparison of angiographic outcomes","volume":"10","author":"Chalouhi","year":"2013"}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/37\/v1supplement\/2014.v2.focus14182.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/37\/v1supplement\/2014.v2.focus14182.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/37\/v1supplement\/2014.v2.focus14182.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T08:42:41Z","timestamp":1780130561000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/37\/v1supplement\/2014.v2.focus14182.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7]]},"references-count":3,"journal-issue":{"issue":"v1supplement"},"URL":"https:\/\/doi.org\/10.3171\/2014.v2.focus14182","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,7]]}}}