{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T00:06:12Z","timestamp":1786406772622,"version":"build-2736575974"},"reference-count":55,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2016,7]]},"abstract":"<jats:sec>\n<jats:title>OBJECTIVE<\/jats:title>\n<jats:p>Loosening and pullout of pedicle screws are well-known problems in pedicle screw fixation surgery. Augmentation of pedicle screws with bone cement, first described as early as 1975, increases the pedicle-screw interface and pullout force in osteoporotic vertebrae. The aim of the present study was to identify cement leakage and pulmonary embolism rates in a large prospective single-center series of pedicle screw augmentations.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>METHODS<\/jats:title>\n<jats:p>All patients who underwent cement-augmented pedicle screw placement between May 2006 and October 2010 at the authors' institution were included in this prospective cohort study. Perivertebral cement leakage and pulmonary cement embolism were evaluated with a CT scan of the area of operation and with a radiograph of the chest, respectively.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>RESULTS<\/jats:title>\n<jats:p>A total of 98 patients underwent placement of cement-augmented pedicle screws; 474 augmented screws were inserted in 237 vertebrae. No symptomatic perivertebral cement leakage or symptomatic pulmonary cement embolism was observed, but asymptomatic perivertebral cement leakage was seen in 88 patients (93.6%) and in 165 augmented vertebrae (73.3%). Cement leakage most often occurred in the perivertebral venous system. Clinically asymptomatic pulmonary cement embolism was found in 4 patients (4.1%).<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>CONCLUSIONS<\/jats:title>\n<jats:p>Perivertebral cement leakage often occurs in pedicle screw augmentation, but in most cases, it is clinically asymptomatic. Cement augmentation should be performed under continuous fluoroscopy to avoid high-volume leakage. Alternative strategies, such as use of expandable screws, should be examined in more detail for patients at high risk of screw loosening.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2015.10.spine15511","type":"journal-article","created":{"date-parts":[[2016,3,4]],"date-time":"2016-03-04T15:02:02Z","timestamp":1457103722000},"page":"103-109","source":"Crossref","is-referenced-by-count":64,"title":["Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws"],"prefix":"10.3171","volume":"25","author":[{"given":"Jan U.","family":"Mueller","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, University Medicine Greifswald,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joerg","family":"Baldauf","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Medicine Greifswald,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sascha","family":"Marx","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Medicine Greifswald,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Kirsch","sequence":"additional","affiliation":[{"name":"Department of Radiology and Neuroradiology, University Medicine Greifswald, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henry W. S.","family":"Schroeder","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Medicine Greifswald,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk T.","family":"Pillich","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University Medicine Greifswald,"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-spine15511","series-title":"J Orthop Surg (Hong Kong)","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1177\/230949901001800322","article-title":"Pulmonary cement embolism during cement augmentation of pedicle screw fixation: a case report","volume":"18","author":"Akinola","year":"2010"},{"key":"b2-spine15511","series-title":"J Orthop Traumatol","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s10195-011-0164-9","article-title":"Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases","volume":"12","author":"Amendola","year":"2011"},{"key":"b3-spine15511","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1097\/BSD.0b013e31818e0945","article-title":"The pedicle screw fixation with vertebroplasty augmentation in the surgical treatment of the severe osteoporotic spines","volume":"22","author":"Aydogan","year":"2009"},{"key":"b4-spine15511","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1007\/s00586-008-0769-8","article-title":"Assessment of different screw augmentation techniques and screw designs in osteoporotic spines","volume":"17","author":"Becker","year":"2008"},{"key":"b5-spine15511","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"23","DOI":"10.3171\/2009.3.SPINE08625","article-title":"Revision characteristics of cement-augmented, cannulated-fenestrated pedicle screws in the osteoporotic vertebral body: a biomechanical in vitro investigation. Technical note","volume":"11","author":"Blattert","year":"2009"},{"key":"b6-spine15511","series-title":"Orthopade","first-page":"673","article-title":"[Pedicle screw augmentation from a biomechanical perspective.]","volume":"39","author":"Bullmann","year":"2010"},{"key":"b7-spine15511","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E932","DOI":"10.1097\/BRS.0b013e3181c6ec60","article-title":"Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers","volume":"35","author":"Bullmann","year":"2010"},{"key":"b8-spine15511","series-title":"J Bone Joint Surg Am","doi-asserted-by":"publisher","first-page":"655","DOI":"10.2106\/00004623-197557050-00013","article-title":"Use of polymethylmethacrylate to enhance screw fixation in bone","volume":"57","author":"Cameron","year":"1975"},{"key":"b9-spine15511","series-title":"Radiol Med (Torino)","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1007\/s11547-008-0230-1","article-title":"CT-guided percutaneous vertebroplasty: personal experience in the treatment of osteoporotic fractures and dorsolumbar metastases","volume":"113","author":"Caudana","year":"2008"},{"key":"b10-spine15511","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1097\/BSD.0b013e318246ae8a","article-title":"Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method","volume":"26","author":"Chang","year":"2013"},{"key":"b11-spine15511","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E317","DOI":"10.1097\/BRS.0b013e31816f6c73","article-title":"Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique","volume":"33","author":"Chang","year":"2008"},{"key":"b12-spine15511","series-title":"Clin Biomech (Bristol, Avon)","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1016\/j.clinbiomech.2009.05.002","article-title":"Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping","volume":"24","author":"Chen","year":"2009"},{"key":"b13-spine15511","series-title":"Med Eng Phys","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1016\/j.medengphy.2014.05.003","article-title":"Biomechanical study of expandable pedicle screw fixation in severe osteoporotic bone comparing with conventional and cement-augmented pedicle screws","volume":"36","author":"Chen","year":"2014"},{"key":"b14-spine15511","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1476","DOI":"10.1007\/s00586-008-0776-9","article-title":"Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine","volume":"17","author":"Chen","year":"2008"},{"key":"b15-spine15511","series-title":"Ann Rheum Dis","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1136\/ard.37.4.378","article-title":"Studies with pain rating scales","volume":"37","author":"Downie","year":"1978"},{"key":"b16-spine15511","series-title":"Acta Radiol","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1080\/02841850701422153","article-title":"Pulmonary cement embolism: a complication of percutaneous vertebroplasty","volume":"48","author":"Duran","year":"2007"},{"key":"b17-spine15511","series-title":"Biomed Tech (Berl)","first-page":"473","article-title":"Correlation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement","volume":"57","author":"F\u00f6lsch","year":"2012"},{"key":"b18-spine15511","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"47","DOI":"10.3171\/SPI-07\/07\/047","article-title":"A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation","volume":"7","author":"Frankel","year":"2007"},{"key":"b19-spine15511","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1227\/01.NEU.0000290899.15567.68","article-title":"Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation","volume":"61","author":"Frankel","year":"2007"},{"key":"b20-spine15511","series-title":"Technol Health Care","doi-asserted-by":"publisher","first-page":"607","DOI":"10.3233\/THC-140815","article-title":"PMMA-augmentation of incompletely cannulated pedicle screws: a cadaver study to determine the benefits in the osteoporotic spine","volume":"22","author":"Goost","year":"2014"},{"key":"b21-spine15511","series-title":"Anat Rec","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1002\/(SICI)1097-0185(199710)249:2<285::AID-AR16>3.0.CO;2-K","article-title":"Morphology of the human internal vertebral venous plexus: a cadaver study after intravenous Araldite CY 221 injection","volume":"249","author":"Groen","year":"1997"},{"key":"b22-spine15511","series-title":"Rofo","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1055\/s-2004-813869","article-title":"[Percutaneous vertebroplasty\u2013the role of osseous phlebography.]","volume":"177","author":"Hierholzer","year":"2005"},{"key":"b23-spine15511","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2504","DOI":"10.1097\/00007632-199711010-00007","article-title":"Structural characteristics of the pedicle and its role in screw stability","volume":"22","author":"Hirano","year":"1997"},{"key":"b24-spine15511","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"669","DOI":"10.3174\/ajnr.A1442","article-title":"Kyphoplasty and vertebroplasty produce the same degree of height restoration","volume":"30","author":"Hiwatashi","year":"2009"},{"key":"b25-spine15511","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1007\/s00586-011-1824-4","article-title":"Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body","volume":"20","author":"Hu","year":"2011"},{"key":"b26-spine15511","series-title":"Clin Lymphoma Myeloma","doi-asserted-by":"publisher","first-page":"375","DOI":"10.3816\/CLM.2009.n.073","article-title":"Kyphoplasty for patients with multiple myeloma is a safe surgical procedure: results from a large patient cohort","volume":"9","author":"Huber","year":"2009"},{"key":"b27-spine15511","series-title":"Orthopade","first-page":"679","article-title":"[Cement distribution in vertebroplasty pedicle screws with different designs.]","volume":"39","author":"Kafchitsas","year":"2010"},{"key":"b28-spine15511","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1007\/s00701-008-1569-y","article-title":"Comparison of CT characteristics of extravertebral cement leakages after vertebroplasty performed by different navigation and injection techniques","volume":"150","author":"Kas\u00f3","year":"2008"},{"key":"b29-spine15511","series-title":"Orthop Rev (Pavia)","doi-asserted-by":"publisher","first-page":"e24","DOI":"10.4081\/or.2013.e24","article-title":"Cement embolism into the venous system after pedicle screw fixation: case report, literature review, and prevention tips","volume":"5","author":"Kerry","year":"2013"},{"key":"b30-spine15511","series-title":"Radiology","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1148\/radiol.2511080854","article-title":"Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors","volume":"251","author":"Kim","year":"2009"},{"key":"b31-spine15511","series-title":"Scientific World Journal","first-page":"979186","article-title":"Minimally invasive technique for PMMA augmentation of fenestrated screws","volume":"2015","author":"Klingler","year":"2015"},{"key":"b32-spine15511","series-title":"Eur Radiol","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1007\/s00330-005-0056-6","article-title":"Kyphosis reduction and the rate of cement leaks after vertebroplasty of intravertebral clefts","volume":"16","author":"Krauss","year":"2006"},{"key":"b33-spine15511","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1007\/s00586-009-1073-y","article-title":"Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature","volume":"18","author":"Krueger","year":"2009"},{"key":"b34-spine15511","series-title":"PLoS One","doi-asserted-by":"publisher","first-page":"e74827","DOI":"10.1371\/journal.pone.0074827","article-title":"Comparison of expansive pedicle screw and polymethylmethacrylate-augmented pedicle screw in osteoporotic sheep lumbar vertebrae: biomechanical and interfacial evaluations","volume":"8","author":"Liu","year":"2013"},{"key":"b35-spine15511","series-title":"J Korean Neurosurg Soc","doi-asserted-by":"publisher","first-page":"305","DOI":"10.3340\/jkns.2009.46.4.305","article-title":"Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine: a three-year follow-up of 37 patients","volume":"46","author":"Moon","year":"2009"},{"key":"b36-spine15511","series-title":"Eur Radiol","doi-asserted-by":"publisher","first-page":"2568","DOI":"10.1007\/s00330-008-1020-z","article-title":"CT-guided vertebroplasty: analysis of technical results, extraosseous cement leakages, and complications in 500 procedures","volume":"18","author":"Pitton","year":"2008"},{"key":"b37-spine15511","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1016\/j.spinee.2013.06.067","article-title":"DensiProbe Spine: an intraoperative measurement of bone quality in spinal instrumentation. A clinical feasibility study","volume":"13","author":"Popp","year":"2013"},{"key":"b38-spine15511","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1007\/s00586-011-2106-x","article-title":"Percutaneous augmented instrumentation of unstable thoracolumbar burst fractures","volume":"21","author":"Rahamimov","year":"2012"},{"key":"b39-spine15511","series-title":"Acta Orthop Belg","first-page":"269","article-title":"Pulmonary cement embolism after augmentation of pedicle screws with bone cement","volume":"76","author":"R\u00f6llinghoff","year":"2010"},{"issue":"203","key":"b40-spine15511","series-title":"Clin Orthop Relat Res","first-page":"7","article-title":"Internal fixation of the lumbar spine with pedicle screw plating","author":"Roy-Camille","year":"1986"},{"key":"b41-spine15511","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1007\/s00586-004-0839-5","article-title":"Cement leakage during vertebroplasty: an underestimated problem?","volume":"14","author":"Schmidt","year":"2005"},{"key":"b42-spine15511","series-title":"BioMed Res Int","first-page":"748393","article-title":"Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status","volume":"2014","author":"Shea","year":"2014"},{"key":"b43-spine15511","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1097\/00007632-199111000-00015","article-title":"An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine","volume":"16","author":"Soshi","year":"1991"},{"key":"b44-spine15511","series-title":"AJR Am J Roentgenol","doi-asserted-by":"publisher","first-page":"W442","DOI":"10.2214\/AJR.09.2774","article-title":"Cement leakage in percutaneous vertebroplasty for osteoporotic compression fractures with or without intravertebral clefts","volume":"193","author":"Tanigawa","year":"2009"},{"key":"b45-spine15511","series-title":"Neuroradiology","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s00234-010-0705-6","article-title":"Postprocedural CT for perivertebral cement leakage in percutaneous vertebroplasty is not necessary\u2014results from VERTOS II","volume":"53","author":"Venmans","year":"2011"},{"key":"b46-spine15511","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"1983","DOI":"10.3174\/ajnr.A1269","article-title":"Frequency and outcome of pulmonary polymethylmethacrylate embolism during percutaneous vertebroplasty","volume":"29","author":"Venmans","year":"2008"},{"key":"b47-spine15511","series-title":"Unfallchirurg","first-page":"403","article-title":"[Results of balloon kyphoplasty in the treatment of osteoporotic vertebral compression fractures.]","volume":"111","author":"Voggenreiter","year":"2008"},{"key":"b48-spine15511","series-title":"Eur Radiol","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1007\/s00330-005-0021-4","article-title":"CT-guided percutaneous vertebroplasty in the therapy of vertebral compression fractures","volume":"16","author":"Vogl","year":"2006"},{"key":"b49-spine15511","series-title":"Rofo","first-page":"610","article-title":"[CT-guided vertebroplasty and kyphoplasty: comparing technical success rate and complications in 101 cases.]","volume":"178","author":"Weber","year":"2006"},{"key":"b50-spine15511","series-title":"Arch Orthop Trauma Surg","doi-asserted-by":"publisher","first-page":"1493","DOI":"10.1007\/s00402-013-1842-2","article-title":"Biomechanical evaluation of the primary stability of pedicle screws after augmentation with an innovative bone stabilizing system","volume":"133","author":"Wegmann","year":"2013"},{"issue":"284","key":"b51-spine15511","series-title":"Clin Orthop Relat Res","first-page":"34","article-title":"Anatomic and technical considerations of pedicle screw fixation","author":"Weinstein","year":"1992"},{"key":"b52-spine15511","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1097\/00007632-198809000-00008","article-title":"Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement","volume":"13","author":"Weinstein","year":"1988"},{"key":"b53-spine15511","series-title":"J Surg Res","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.jss.2010.09.009","article-title":"Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients","volume":"173","author":"Wu","year":"2012"},{"key":"b54-spine15511","series-title":"J Bone Joint Surg Br","first-page":"83","article-title":"Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures","volume":"85","author":"Yeom","year":"2003"},{"issue":"203","key":"b55-spine15511","series-title":"Clin Orthop Relat Res","first-page":"99","article-title":"A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine","author":"Zindrick","year":"1986"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/25\/1\/article-p103.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/25\/1\/article-p103.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/25\/1\/article-p103.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T22:00:00Z","timestamp":1681596000000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/25\/1\/article-p103.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7]]},"references-count":55,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3171\/2015.10.spine15511","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7]]}}}