{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T15:24:15Z","timestamp":1794324255163,"version":"4.9.0"},"reference-count":42,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2015,12]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECT<\/jats:title>\n                    <jats:p>Abnormal sacral slope (SS) has shown to increase progression of spondylolisthesis, yet there exists a paucity in biomechanical studies investigating its role in the correction of adult spinal deformity, its influence on lumbosacral shear, and its impact on the instrumentation selection process. This in vitro study investigates the effect of SS on 3 anterior lumbar interbody fusion constructs in a biomechanics laboratory.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>Nine healthy, fresh-frozen, intact human lumbosacral vertebral segments were tested by applying a 550-N axial load to specimens with an initial SS of 20\u00b0 on an MTS Bionix test system. Testing was repeated as SS was increased to 50\u00b0, in 10\u00b0 increments, through an angulated testing fixture. Specimens were instrumented using a standalone integrated spacer with self-contained screws (SA), an interbody spacer with posterior pedicle screws (PPS), and an interbody spacer with anterior tension band plate (ATB) in a randomized order. Stiffness was calculated from the linear portion of the load-deformation curve. Ultimate strength was also recorded on the final construct of all specimens (n = 3 per construct) with SS of 40\u00b0.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>Axial stiffness (N\/mm) of the L5\u2013S1 motion segment was measured at various angles of SS: for SA 292.9 \u00b1 142.8 (20\u00b0), 277.2 \u00b1 113.7 (30\u00b0), 237.0 \u00b1 108.7 (40\u00b0), 170.3 \u00b1 74.1 (50\u00b0); for PPS 371.2 \u00b1 237.5 (20\u00b0), 319.8 \u00b1 167.2 (30\u00b0), 280.4 \u00b1 151.7 (40\u00b0), 233.0 \u00b1 117.6 (50\u00b0); and for ATB 323.9 \u00b1 210.4 (20\u00b0), 307.8 \u00b1 125.4 (30\u00b0), 249.4 \u00b1 126.7 (40\u00b0), 217.7 \u00b1 99.4 (50\u00b0). Axial compression across the disc space decreased with increasing SS, indicating that SS beyond 40\u00b0 threshold shifted L5\u2013S1 motion into pure shear, instead of compression-shear, defining a threshold. Trends in ultimate load and displacement differed from linear stiffness with SA &gt; PPS &gt; ATB.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>At larger SSs, bilateral pedicle screw constructs with spacers were the most stable; however, none of the constructs were significantly stiffer than intact segments. For load to failure, the integrated spacer performed the best; this may be due to angulations of integrated plate screws. Increasing SS significantly reduced stiffness, which indicates that surgeons need to consider using more aggressive fixation techniques.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2015.3.spine14557","type":"journal-article","created":{"date-parts":[[2015,8,14]],"date-time":"2015-08-14T10:02:45Z","timestamp":1439546565000},"page":"754-762","source":"Crossref","is-referenced-by-count":22,"title":["The role of sacral slope in lumbosacral fusion: a biomechanical study"],"prefix":"10.3171","volume":"23","author":[{"given":"Doniel","family":"Drazin","sequence":"first","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mir","family":"Hussain","sequence":"additional","affiliation":[{"name":"Globus Medical, Inc., Valley Forge Business Center, Audubon, Pennsylvania; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Harris","sequence":"additional","affiliation":[{"name":"Globus Medical, Inc., Valley Forge Business Center, Audubon, Pennsylvania; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Hao","sequence":"additional","affiliation":[{"name":"Globus Medical, Inc., Valley Forge Business Center, Audubon, Pennsylvania; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matt","family":"Phillips","sequence":"additional","affiliation":[{"name":"Globus Medical, Inc., Valley Forge Business Center, Audubon, Pennsylvania; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terrence T.","family":"Kim","sequence":"additional","affiliation":[{"name":"Orthopedics, Cedars-Sinai Medical Center, Los Angeles, California;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Patrick","family":"Johnson","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"},{"name":"Department of Neurosurgery, University of California, Davis, Sacramento, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brandon","family":"Bucklen","sequence":"additional","affiliation":[{"name":"Globus Medical, Inc., Valley Forge Business Center, Audubon, Pennsylvania; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E166","DOI":"10.1097\/BRS.0000000000000073","article-title":"Sagittal balance and spinopelvic parameters after lateral lumbar interbody fusion for degenerative scoliosis: a case-control study","volume":"39","author":"Baghdadi","year":"2014"},{"key":"b2-spine14557","series-title":"ISRN Orthop","first-page":"183702","article-title":"Pedicle-screw-based dynamic systems and degenerative lumbar diseases: biomechanical and clinical experiences of dynamic fusion with isobar TTL","volume":"2013","author":"Barrey","year":"2013"},{"key":"b3-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1097\/BRS.0b013e3181e92458","article-title":"Spinal instrumentation after complete resection of the last lumbar vertebra: an in vitro biomechanical study after L5 spondylectomy","volume":"36","author":"Bartanusz","year":"2011"},{"key":"b4-spine14557","series-title":"J Spinal Disord","first-page":"68","article-title":"The role of lumbar lordosis, vertebral end-plate inclination, disc height, and facet orientation in degenerative spondylolisthesis","volume":"12","author":"Berlemann","year":"1999"},{"key":"b5-spine14557","series-title":"J Spinal Disord","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/00002517-199106000-00002","article-title":"Management of adult spinal deformity with combined anterior-posterior arthrodesis and Luque-Galveston instrumentation","volume":"4","author":"Boachie-Adjei","year":"1991"},{"key":"b6-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/00007632-199002000-00012","article-title":"Discs degenerate before facets","volume":"15","author":"Butler","year":"1990"},{"key":"b7-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2631","DOI":"10.1097\/01.brs.0000187897.25889.54","article-title":"A new stand-alone anterior lumbar interbody fusion device: biomechanical comparison with established fixation techniques","volume":"30","author":"Cain","year":"2005"},{"issue":"6 Suppl","key":"b8-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S196","DOI":"10.1097\/00007632-199206001-00023","article-title":"Screw fixation in the human sacrum. An in vitro study of the biomechanics of fixation","volume":"17","author":"Carlson","year":"1992"},{"key":"b9-spine14557","series-title":"Technol Health Care","doi-asserted-by":"publisher","first-page":"467","DOI":"10.3233\/THC-140805","article-title":"A study on difference and importance of sacral slope and pelvic sacral angle that affect lumbar curvature","volume":"22","author":"Choi","year":"2014"},{"key":"b10-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1996","DOI":"10.1097\/01.brs.0000138272.54896.33","article-title":"Long adult deformity fusions to L5 and the sacrum. A matched cohort analysis","volume":"29","author":"Edwards","year":"2004"},{"key":"b11-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"776","DOI":"10.1097\/00007632-200204010-00017","article-title":"Outcome and complications of long fusions to the sacrum in adult spine deformity: Luque-Galveston, combined iliac and sacral screws, and sacral fixation","volume":"27","author":"Emami","year":"2002"},{"key":"b12-spine14557","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"E20","DOI":"10.1097\/BSD.0b013e31828af6f0","article-title":"Influence of the posterior lumbar interbody fusion on the sagittal spino-pelvic parameters in isthmic L5\u2013S1 spondylolisthesis","volume":"27","author":"Feng","year":"2014"},{"key":"b13-spine14557","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"2181","DOI":"10.1007\/s00586-012-2374-0","article-title":"Comparative study of spinopelvic sagittal alignment between patients with and without degenerative spondylolisthesis","volume":"21","author":"Funao","year":"2012"},{"key":"b14-spine14557","series-title":"J Spinal Disord Tech","article-title":"The correlation between restoration of lumbar lordosis and surgical outcome in the treatment of low-grade lumbar degenerative spondylolisthesis with spinal fusion","author":"Hsu","year":"2013"},{"key":"b15-spine14557","series-title":"J Anat","first-page":"753","article-title":"The compressive strength of lumbar vertebrae","volume":"129","author":"Hutton","year":"1979"},{"key":"b16-spine14557","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"2905","DOI":"10.1016\/j.spinee.2014.04.016","article-title":"Prospective analysis of adverse events in surgical treatment of degenerative spondylolisthesis","volume":"14","author":"Kelly","year":"2014"},{"key":"b17-spine14557","series-title":"J Back Musculoskelet Rehabil","doi-asserted-by":"publisher","first-page":"231","DOI":"10.3233\/BMR-130442","article-title":"Influences of posterior-located center of gravity on lumbar extension strength, balance, and lumbar lordosis in chronic low back pain","volume":"27","author":"Kim","year":"2014"},{"key":"b18-spine14557","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1097\/BSD.0b013e3180577223","article-title":"Anterior lumbar interbody fusion for lumbosacral junction in steep sacral slope","volume":"21","author":"Kim","year":"2008"},{"key":"b19-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1097\/BRS.0b013e318257f12a","article-title":"Risk factors for cage retropulsion after posterior lumbar interbody fusion: analysis of 1070 cases","volume":"37","author":"Kimura","year":"2012"},{"key":"b20-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2596","DOI":"10.1097\/00007632-200112010-00014","article-title":"Lumbar spine disc height and curvature responses to an axial load generated by a compression device compatible with magnetic resonance imaging","volume":"26","author":"Kimura","year":"2001"},{"issue":"6 Suppl","key":"b21-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S27","DOI":"10.1097\/01.brs.0000155560.92580.90","article-title":"The importance of spino-pelvic balance in L5\u2013S1 developmental spondylolisthesis: a review of pertinent radiologic measurements","volume":"30","author":"Labelle","year":"2005"},{"key":"b22-spine14557","series-title":"J Spinal Disord","first-page":"300","article-title":"Functional outcome after partial reduction and 360 degree fusion in grade III-V spondylolisthesis in adolescent and adult patients","volume":"12","author":"Laursen","year":"1999"},{"key":"b23-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2312","DOI":"10.1097\/00007632-200211010-00003","article-title":"Biomechanical comparison of lumbosacral fixation techniques in a calf spine model","volume":"27","author":"Lebwohl","year":"2002"},{"key":"b24-spine14557","series-title":"Clin Orthop Surg","doi-asserted-by":"publisher","first-page":"39","DOI":"10.4055\/cios.2011.3.1.39","article-title":"Fusion rates of instrumented lumbar spinal arthrodesis according to surgical approach: a systematic review of randomized trials","volume":"3","author":"Lee","year":"2011"},{"key":"b25-spine14557","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"E259","DOI":"10.1097\/BSD.0b013e318261f346","article-title":"Analysis of sagittal spinal alignment in 181 asymptomatic children","volume":"25","author":"Lee","year":"2012"},{"key":"b26-spine14557","series-title":"Chin Med J (Engl)","first-page":"1732","article-title":"Comparison of the effect of posterior lumbar interbody fusion with pedicle screw fixation and interspinous fixation on the stiffness of adjacent segments","volume":"126","author":"Li","year":"2013"},{"key":"b27-spine14557","series-title":"J Korean Neurosurg Soc","doi-asserted-by":"publisher","first-page":"96","DOI":"10.3340\/jkns.2013.53.2.96","article-title":"Difference of sagittal spinopelvic alignments between degenerative spondylolisthesis and isthmic spondylolisthesis","volume":"53","author":"Lim","year":"2013"},{"key":"b28-spine14557","series-title":"Osteoporos Int","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1007\/s00198-013-2484-5","article-title":"Inclinometer-based measures of standing posture in older adults with low bone mass are reliable and associated with self-reported, but not performance-based, physical function","volume":"25","author":"MacIntyre","year":"2014"},{"key":"b29-spine14557","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"204","DOI":"10.3171\/2013.11.SPINE13518","article-title":"A novel method of anterior lumbosacral cage reconstruction","volume":"20","author":"Mathios","year":"2014"},{"key":"b30-spine14557","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1227\/NEU.0b013e31823262ea","article-title":"Implications of spinopelvic alignment for the spine surgeon","volume":"70","author":"Mehta","year":"2012"},{"key":"b31-spine14557","series-title":"Iowa Orthop J","first-page":"199","article-title":"Proximal junctional kyphosis in adult reconstructive spine surgery results from incomplete restoration of the lumbar lordosis relative to the magnitude of the thoracic kyphosis","volume":"31","author":"Mendoza-Lattes","year":"2011"},{"key":"b32-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1097\/00007632-200003150-00014","article-title":"Radiographic analysis of lumbar motion in relation to lumbosacral stability. Investigation of moderate and maximum motion","volume":"25","author":"Miyasaka","year":"2000"},{"issue":"3 Suppl","key":"b33-spine14557","series-title":"J Neurosurg","first-page":"277","article-title":"Effect of spinal disease on successful arthrodesis in lumbar pedicle screw fixation","volume":"97","author":"Narayan","year":"2002"},{"key":"b34-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E326","DOI":"10.1097\/BRS.0000000000000141","article-title":"Rate of revision surgery after stand-alone lateral lumbar interbody fusion for lumbar spinal stenosis","volume":"39","author":"Nemani","year":"2014"},{"issue":"19 Suppl","key":"b35-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S179","DOI":"10.1097\/01.brs.0000234761.87368.ee","article-title":"Debate: to fuse or not to fuse to the sacrum, the fate of the L5\u2013S1 disc","volume":"31","author":"Polly","year":"2006"},{"key":"b36-spine14557","series-title":"Indian J Orthop","doi-asserted-by":"publisher","first-page":"340","DOI":"10.4103\/0019-5413.114909","article-title":"Complications in lumbar spine surgery: A retrospective analysis","volume":"47","author":"Proietti","year":"2013"},{"key":"b37-spine14557","series-title":"J Biomech","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/S0021-9290(98)00037-2","article-title":"Axial stiffness of human lumbar motion segments, force dependence","volume":"31","author":"Rostedt","year":"1998"},{"issue":"Suppl 5","key":"b38-spine14557","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1007\/s00586-011-1928-x","article-title":"Biomechanical analysis of the spino-pelvic organization and adaptation in pathology","volume":"20","author":"Roussouly","year":"2011"},{"issue":"1 Suppl","key":"b39-spine14557","series-title":"Orthop Traumatol Surg Res","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1016\/j.otsr.2013.06.018","article-title":"Total disc replacement","volume":"100","author":"Vital","year":"2014"},{"key":"b40-spine14557","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.spinee.2012.02.013","article-title":"A review of methods for evaluating the quantitative parameters of sagittal pelvic alignment","volume":"12","author":"Vrtovec","year":"2012"},{"key":"b41-spine14557","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1636","DOI":"10.1097\/01.BRS.0000132320.39297.6C","article-title":"The flexion-extension profile of lumbar spine in 100 healthy volunteers","volume":"29","author":"Wong","year":"2004"},{"key":"b42-spine14557","series-title":"Orthop Surg","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1111\/j.1757-7861.2011.00164.x","article-title":"Are stand-alone cages sufficient for anterior lumbar interbody fusion?","volume":"4","author":"Zhang","year":"2012"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/23\/6\/article-p754.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/23\/6\/article-p754.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/23\/6\/article-p754.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T17:46:12Z","timestamp":1681580772000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/23\/6\/article-p754.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12]]},"references-count":42,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2015.3.spine14557","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2015,12]]}}}