{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T15:24:29Z","timestamp":1794324269406,"version":"4.9.0"},"reference-count":27,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2016,9]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>A novel technique for monitoring intraspinal pressure and spinal cord perfusion pressure in patients with traumatic spinal cord injury was recently described. This is analogous to monitoring intracranial pressure and cerebral perfusion pressure in patients with traumatic brain injury. Because intraspinal pressure monitoring is a new technique, its safety profile and impact on early patient care and long-term outcome after traumatic spinal cord injury are unknown. The object of this study is to review all patients who had intraspinal pressure monitoring to date at the authors' institution in order to define the accuracy of intraspinal pressure probe placement and the safety of the technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>At the end of surgery to fix spinal fractures, a pressure probe was inserted intradurally to monitor intraspinal pressure at the injury site. Postoperatively, CT scanning was performed within 48 hours and MRI at 2 weeks and 6 months. Neurointensive care management and complications were reviewed. The American Spinal Injury Association Impairment Scale (AIS) grade was determined on admission and at 2 to 4 weeks and 12 to 18 months postoperation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>To date, 42 patients with severe traumatic spinal cord injuries (AIS Grades A\u2013C) had undergone intraspinal pressure monitoring. Monitoring started within 72 hours of injury and continued for up to a week. Based on postoperative CT and MRI, the probe position was acceptable in all patients, i.e., the probe was located at the site of maximum spinal cord swelling. Complications were probe displacement in 1 of 42 patients (2.4%), CSF leakage that required wound resuturing in 3 of 42 patients (7.1%), and asymptomatic pseudomeningocele that was diagnosed in 8 of 42 patients (19.0%). Pseudomeningocele was diagnosed on MRI and resolved within 6 months in all patients. Based on the MRI and neurological examination results, there were no serious probe-related complications such as meningitis, wound infection, hematoma, wound breakdown, or neurological deterioration. Within 2 weeks postoperatively, 75% of patients were extubated and 25% underwent tracheostomy. Norepinephrine was used to support blood pressure without complications. Overall, the mean intraspinal pressure was around 20 mm Hg, and the mean spinal cord perfusion pressure was around 70 mm Hg. In laminectomized patients, the intraspinal pressure was significantly higher in the supine than lateral position by up to 18 mm Hg after thoracic laminectomy and 8 mm Hg after cervical laminectomy. At 12 to 18 months, 11.4% of patients had improved by 1 AIS grade and 14.3% by at least 2 AIS grades.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>These data suggest that after traumatic spinal cord injury intradural placement of the pressure probe is accurate and intraspinal pressure monitoring is safe for up to a week. In patients with spinal cord injury who had laminectomy, the supine position should be avoided in order to prevent rises in intraspinal pressure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2016.1.spine151317","type":"journal-article","created":{"date-parts":[[2016,4,29]],"date-time":"2016-04-29T10:10:29Z","timestamp":1461924629000},"page":"398-405","source":"Crossref","is-referenced-by-count":62,"title":["Safety profile and probe placement accuracy of intraspinal pressure monitoring for traumatic spinal cord injury: Injured Spinal Cord Pressure Evaluation study"],"prefix":"10.3171","volume":"25","author":[{"given":"Isaac","family":"Phang","sequence":"first","affiliation":[{"name":"Academic Neurosurgery Unit, St. George's, University of London; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Argyro","family":"Zoumprouli","sequence":"additional","affiliation":[{"name":"Neurointensive Care Unit, St. George's Hospital, London, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samira","family":"Saadoun","sequence":"additional","affiliation":[{"name":"Academic Neurosurgery Unit, St. George's, University of London; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marios C.","family":"Papadopoulos","sequence":"additional","affiliation":[{"name":"Academic Neurosurgery Unit, St. George's, University of London; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-spine151317","series-title":"Spinal Cord","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1038\/sc.2009.140","article-title":"Using the Spinal Cord Independence Measure III to measure functional recovery in a post-acute spinal cord injury program","volume":"48","author":"Ackerman","year":"2010"},{"key":"b2-spine151317","series-title":"Crit Care Med","doi-asserted-by":"publisher","first-page":"2456","DOI":"10.1097\/CCM.0b013e3182514eb6","article-title":"Continuous determination of optimal cerebral perfusion pressure in traumatic brain injury","volume":"40","author":"Aries","year":"2012"},{"key":"b3-spine151317","series-title":"J Clin Neurosci","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.jocn.2008.02.008","article-title":"Risk factors and complications of intracranial pressure monitoring with a fiberoptic device","volume":"16","author":"Bekar","year":"2009"},{"issue":"Suppl 1","key":"b4-spine151317","series-title":"J Neurotrauma","first-page":"S1","article-title":"Guidelines for the Management of Severe Traumatic Brain Injury, 3rd Edition","volume":"24","author":"Bratton","year":"2007"},{"key":"b5-spine151317","series-title":"J Trauma","first-page":"1673","article-title":"Spinal cord injury: outcomes of ventilatory weaning and extubation","volume":"71","author":"Call","year":"2011"},{"key":"b6-spine151317","series-title":"N Engl J Med","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1056\/NEJMoa1207363","article-title":"A trial of intracranial-pressure monitoring in traumatic brain injury","volume":"367","author":"Chesnut","year":"2012"},{"key":"b7-spine151317","series-title":"J Trauma","first-page":"912","article-title":"Characterizing the need for mechanical ventilation following cervical spinal cord injury with neurologic deficit","volume":"59","author":"Como","year":"2005"},{"key":"b8-spine151317","series-title":"J Neurotrauma","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1089\/neu.2007.0468","article-title":"Recovery from a spinal cord injury: significance of compensation, neural plasticity, and repair","volume":"25","author":"Curt","year":"2008"},{"issue":"5","key":"b9-spine151317","series-title":"Neurosurg Focus","first-page":"E10","article-title":"Intracranial pressure: more than a number","volume":"22","author":"Czosnyka","year":"2007"},{"key":"b10-spine151317","series-title":"Spinal Cord","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1038\/sj.sc.3100993","article-title":"Walking index for spinal cord injury (WISCI): an international multicenter validity and reliability study","volume":"38","author":"Ditunno","year":"2000"},{"key":"b11-spine151317","series-title":"PLoS One","doi-asserted-by":"publisher","first-page":"e32037","DOI":"10.1371\/journal.pone.0032037","article-title":"Early versus delayed decompression for traumatic cervical spinal cord injury: results of the Surgical Timing in Acute Spinal Cord Injury Study (STASCIS)","volume":"7","author":"Fehlings","year":"2012"},{"key":"b12-spine151317","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1007\/s00701-005-0683-3","article-title":"The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases","volume":"148","author":"Gelabert-Gonz\u00e1lez","year":"2006"},{"key":"b13-spine151317","series-title":"BMJ","doi-asserted-by":"publisher","first-page":"e3325","DOI":"10.1136\/bmj.e3325","article-title":"Ventilator associated pneumonia","volume":"344","author":"Hunter","year":"2012"},{"key":"b14-spine151317","series-title":"BMJ","doi-asserted-by":"publisher","first-page":"f1000","DOI":"10.1136\/bmj.f1000","article-title":"Intracranial pressure monitoring in severe traumatic brain injury","volume":"346","author":"Hutchinson","year":"2013"},{"key":"b15-spine151317","series-title":"J Neurotrauma","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1089\/neu.2013.3061","article-title":"Medical and surgical management after spinal cord injury: vasopressor usage, early surgerys, and complications","volume":"31","author":"Inoue","year":"2014"},{"key":"b16-spine151317","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"2141","DOI":"10.1007\/s00701-013-1856-0","article-title":"The complications and the position of the Codman MicroSensor\u2122 ICP device: an analysis of 549 patients and 650 sensors","volume":"155","author":"Koskinen","year":"2013"},{"key":"b17-spine151317","series-title":"Spinal Cord","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1038\/sj.sc.3101887","article-title":"Neurogenic bowel dysfunction score","volume":"44","author":"Krogh","year":"2006"},{"key":"b18-spine151317","series-title":"Neurosurgery","first-page":"E500","article-title":"Intrathecal pressure after spinal cord injury","volume":"77","author":"Papadopoulos","year":"2015"},{"key":"b19-spine151317","series-title":"Neurocrit Care","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1007\/s12028-015-0153-6","article-title":"Intraspinal pressure monitoring in a patient with spinal cord injury reveals different intradural compartments: Injured Spinal Cord Pressure Evaluation (ISCoPE) study","volume":"23","author":"Phang","year":"2015"},{"key":"b20-spine151317","series-title":"J Neurotrauma","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1089\/neu.2014.3668","article-title":"Expansion duroplasty improves intraspinal pressure, spinal cord perfusion pressure, and vascular pressure reactivity index in patients with traumatic spinal cord injury: injured spinal cord pressure evaluation study","volume":"32","author":"Phang","year":"2015"},{"key":"b21-spine151317","series-title":"J Neurol Neurosurg Psychiatry","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1136\/jnnp.69.3.381","article-title":"Infection related to intracranial pressure monitors in adults: analysis of risk factors and antibiotic prophylaxis","volume":"69","author":"Rebuck","year":"2000"},{"key":"b22-spine151317","series-title":"Brain","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1093\/brain\/awn014","article-title":"Greatly improved neurological outcome after spinal cord compression injury in AQP4-deficient mice","volume":"131","author":"Saadoun","year":"2008"},{"key":"b23-spine151317","series-title":"J Neurotrauma","doi-asserted-by":"publisher","first-page":"1781","DOI":"10.1089\/neu.2013.2932","article-title":"The effects of the timing of spinal surgery after traumatic spinal cord injury: a systematic review and meta-analysis","volume":"30","author":"van Middendorp","year":"2013"},{"key":"b24-spine151317","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"763","DOI":"10.3171\/2015.3.SPINE14870","article-title":"Intraspinal pressure and spinal cord perfusion pressure after spinal cord injury: an observational study","volume":"23","author":"Varsos","year":"2015"},{"issue":"Suppl 1","key":"b25-spine151317","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1227\/01.neu.0000430319.32247.7f","article-title":"Guidelines for the management of acute cervical spine and spinal cord injuries: 2013 update","volume":"60","author":"Walters","year":"2013"},{"key":"b26-spine151317","series-title":"Crit Care Med","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1097\/CCM.0000000000000028","article-title":"Monitoring of spinal cord perfusion pressure in acute spinal cord injury: initial findings of the injured spinal cord pressure evaluation study","volume":"42","author":"Werndle","year":"2014"},{"key":"b27-spine151317","series-title":"J Neurotrauma","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1089\/neu.2011.2038","article-title":"Variability in the treatment of acute spinal cord injury in the United Kingdom: results of a national survey","volume":"29","author":"Werndle","year":"2012"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/25\/3\/article-p398.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/25\/3\/article-p398.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/25\/3\/article-p398.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T18:03:59Z","timestamp":1681581839000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/25\/3\/article-p398.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9]]},"references-count":27,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2016.1.spine151317","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2016,9]]}}}