{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T16:29:39Z","timestamp":1787502579699,"version":"build-2736575974"},"reference-count":16,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2016,9]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Lateral lumbar interbody fusion (LLIF) is an increasingly popular technique used to treat degenerative lumbar disease. The technique of using an intraoperative cone-beam CT (iCBCT) and an image-guided navigation system (IGNS) for LLIF cage placement has been previously described. However, other than a small feasibility study, there has been no clinical study evaluating its accuracy or safety. Therefore, the purpose of this study was to evaluate the accuracy and safety of image-guided spinal navigation in LLIF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>An analysis of a prospectively acquired database was performed. Thirty-one consecutive patients were identified. Accuracy was initially determined by comparison of the planned trajectory of the IGNS with post\u2013cage placement intraoperative fluoroscopy. Accuracy was subsequently confirmed by postprocedural CT and\/or radiography. Cage placement was graded based on a previously described system separating the disc space into quarters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>The mean patient age was 63.9 years. A total of 66 spinal levels were treated, with a mean of 2.1 levels (range 1\u20134) treated per patient. Cage placement was noted to be accurate using IGNS in each case, as confirmed with intraoperative fluoroscopy and postoperative imaging. Sixty-four (97%) cages were placed within Quarters 1 to 2 or 2 to 3, indicating placement of the cage in the anterior or middle portions of the disc space. There were no instances of misguidance by IGNS. There was 1 significant approach-related complication (psoas muscle abscess) that required intervention, and 8 patients with transient, mild thigh paresthesias or weakness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>LLIF can be safely and accurately performed utilizing iCBCT and IGNS. Accuracy is acceptable for multilevel procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2016.2.spine151295","type":"journal-article","created":{"date-parts":[[2016,4,22]],"date-time":"2016-04-22T10:02:02Z","timestamp":1461319322000},"page":"339-344","source":"Crossref","is-referenced-by-count":45,"title":["Use of 3D CT-based navigation in minimally invasive lateral lumbar interbody fusion"],"prefix":"10.3171","volume":"25","author":[{"given":"Jacob R.","family":"Joseph","sequence":"first","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brandon W.","family":"Smith","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rakesh D.","family":"Patel","sequence":"additional","affiliation":[{"name":"Orthopedic Surgery, University of Michigan, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Park","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-spine151295","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E1074","DOI":"10.1097\/BRS.0b013e31825786d8","article-title":"Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system","volume":"37","author":"Abdullah","year":"2012"},{"key":"b2-spine151295","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"139","DOI":"10.3171\/2008.10.SPI08479","article-title":"An anatomical study of the lumbosacral plexus as related to the minimally invasive transpsoas approach to the lumbar spine","volume":"10","author":"Benglis","year":"2009"},{"key":"b3-spine151295","series-title":"J Clin Neurosci","doi-asserted-by":"publisher","first-page":"1438","DOI":"10.1016\/j.jocn.2012.12.028","article-title":"CT navigated lateral interbody fusion","volume":"20","author":"Drazin","year":"2013"},{"key":"b4-spine151295","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"Gelalis","year":"2012"},{"key":"b5-spine151295","series-title":"Neurosurg Clin N Am","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.nec.2013.12.002","article-title":"Minimally invasive lateral transpsoas approach to the lumbar spine: pitfalls and complication avoidance","volume":"25","author":"Graham","year":"2014"},{"key":"b6-spine151295","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1097\/BSD.0b013e3181679b8a","article-title":"Direct lateral lumbar interbody fusion for degenerative conditions: early complication profile","volume":"22","author":"Knight","year":"2009"},{"key":"b7-spine151295","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E306","DOI":"10.1097\/BRS.0b013e318281d70b","article-title":"Estimating the effective radiation dose imparted to patients by intraoperative cone-beam computed tomography in thoracolumbar spinal surgery","volume":"38","author":"Lange","year":"2013"},{"issue":"Suppl 3","key":"b8-spine151295","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1007\/s00586-015-3886-1","article-title":"MIS lateral spine surgery: a systematic literature review of complications, outcomes, and economics","volume":"24","author":"Lehmen","year":"2015"},{"key":"b9-spine151295","series-title":"Int J Med Robot","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1002\/rcs.450","article-title":"Surgeon radiation exposure in cone beam computed tomography-based, image-guided spinal surgery","volume":"8","author":"Nottmeier","year":"2012"},{"key":"b10-spine151295","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"226","DOI":"10.3171\/2013.4.SPINE12719","article-title":"Operating room radiation exposure in cone beam computed tomography-based, image-guided spinal surgery: clinical article","volume":"19","author":"Nottmeier","year":"2013"},{"key":"b11-spine151295","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.spinee.2005.08.012","article-title":"Extreme Lateral Interbody Fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion","volume":"6","author":"Ozgur","year":"2006"},{"issue":"Suppl 2","key":"b12-spine151295","series-title":"Neurosurgery","first-page":"259","article-title":"Three-dimensional computed tomography-based spinal navigation in minimally invasive lateral lumbar interbody fusion: feasibility, technique, and initial results","volume":"11","author":"Park","year":"2015"},{"key":"b13-spine151295","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"260","DOI":"10.3171\/2010.3.SPINE09766","article-title":"Defining the safe working zones using the minimally invasive lateral retroperitoneal transpsoas approach: an anatomical study","volume":"13","author":"Uribe","year":"2010"},{"issue":"26 Suppl","key":"b14-spine151295","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S368","DOI":"10.1097\/BRS.0b013e3182027976","article-title":"Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery","volume":"35","author":"Uribe","year":"2010"},{"key":"b15-spine151295","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E1580","DOI":"10.1097\/BRS.0b013e318271b1fa","article-title":"A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation","volume":"37","author":"Van de Kelft","year":"2012"},{"key":"b16-spine151295","series-title":"J XRay Sci Technol","first-page":"305","article-title":"Dosimetric characterization of a cone-beam O-arm imaging system","volume":"17","author":"Zhang","year":"2009"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/25\/3\/article-p339.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/25\/3\/article-p339.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/25\/3\/article-p339.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T18:04:09Z","timestamp":1681581849000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/25\/3\/article-p339.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9]]},"references-count":16,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2016.2.spine151295","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2016,9]]}}}