{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T22:48:26Z","timestamp":1768344506959,"version":"3.49.0"},"reference-count":16,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:p>Recently, treatment of cerebral aneurysms with the Woven EndoBridge (WEB) device has become an established endovascular strategy. However, over time, neurosurgeons and neuroradiologists will be confronted with the challenge of how to treat aneurysm recanalization. The authors report the case of a 49-year-old woman who underwent re-treatment with clipping after the recanalization of a 4 \u00d7 3\u2013mm anterior communicating artery aneurysm that had previously been treated using a 4 \u00d7 3 WEB device. In contrast to the authors\u2019 prior experiences with clipping of previously coiled aneurysms, the WEB device was found to have a responsive softness during clip placement, and the aneurysm was more maneuverable. Moreover, evaluation with indocyanine green angiography was easy to perform because of the transparent mesh of the WEB device. No profound scarring or WEB protrusion was noted during surgery, making the procedure easier and less dangerous with regard to additional complications. The authors suggest that re-treatment via clipping should be considered in select cases of aneurysm recurrence after treatment with an intraaneurysmal flow diverter.<\/jats:p>","DOI":"10.3171\/2017.10.jns171528","type":"journal-article","created":{"date-parts":[[2018,3,23]],"date-time":"2018-03-23T13:59:24Z","timestamp":1521813564000},"page":"891-894","source":"Crossref","is-referenced-by-count":9,"title":["Clipping as re-treatment strategy after treatment of a cerebral aneurysm with the Woven EndoBridge embolization device: case report"],"prefix":"10.3171","volume":"130","author":[{"given":"Gregor","family":"Durner","sequence":"first","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yigit","family":"\u00d6zpeynirci","sequence":"additional","affiliation":[{"name":"Neuroradiology, University of Ulm, G\u00fcnzburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernd","family":"Schmitz","sequence":"additional","affiliation":[{"name":"Neuroradiology, University of Ulm, G\u00fcnzburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian Rainer","family":"Wirtz","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ralph","family":"K\u00f6nig","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrej","family":"Pala","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"868","DOI":"10.3174\/ajnr.A4611","article-title":"Endovascular treatment of intracranial aneurysms with the WEB device: a systematic review of clinical outcomes","volume":"37","author":"Armoiry X","year":"2016","unstructured":"Armoiry X, Turjman F, Hartmann DJ, Sivan-Hoffmann R, Riva R, Labeyrie PE, : Endovascular treatment of intracranial aneurysms with the WEB device: a systematic review of clinical outcomes. AJNR Am J Neuroradiol 37:868\u2013872, 201610.3174\/ajnr.A461126585260"},{"key":"b2","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"1538","DOI":"10.1161\/STROKEAHA.106.466987","article-title":"Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT)","volume":"38","author":"Campi A","year":"2007","unstructured":"Campi A, Ramzi N, Molyneux AJ, Summers PE, Kerr RSC, Sneade M, : Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT). Stroke 38:1538\u20131544, 20071739587010.1161\/STROKEAHA.106.466987"},{"key":"b3","series-title":"Neuroradiology","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1007\/s00234-016-1715-9","article-title":"Occlusion assessment of intracranial aneurysms treated with the WEB device","volume":"58","author":"Caroff J","year":"2016","unstructured":"Caroff J, Mihalea C, Tuilier T, Barreau X, Cognard C, Desal H, : Occlusion assessment of intracranial aneurysms treated with the WEB device. Neuroradiology 58:887\u2013891, 20162731247510.1007\/s00234-016-1715-9"},{"key":"b4","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.3171\/2015.10.JNS151544","article-title":"Clipping of previously coiled cerebral aneurysms: efficacy, safety, and predictors in a cohort of 111 patients","volume":"125","author":"Daou B","year":"2016","unstructured":"Daou B, Chalouhi N, Starke RM, Barros G, Ya\u2019qoub L, Do J, : Clipping of previously coiled cerebral aneurysms: efficacy, safety, and predictors in a cohort of 111 patients. J Neurosurg 125:1337\u20131343, 201610.3171\/2015.10.JNS151544"},{"key":"b5","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"607","DOI":"10.3174\/ajnr.A2399","article-title":"The Woven EndoBridge: a new aneurysm occlusion device","volume":"32","author":"Ding YH","year":"2011","unstructured":"Ding YH, Lewis DA, Kadirvel R, Dai D, Kallmes DF: The Woven EndoBridge: a new aneurysm occlusion device. AJNR Am J Neuroradiol 32:607\u2013611, 20112133039710.3174\/ajnr.A2399"},{"key":"b6","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.3174\/ajnr.A4282","article-title":"Endovascular treatment of wide-neck anterior communicating artery aneurysms using WEB-DL and WEB-SL: short-term results in a multicenter study","volume":"36","author":"Gherasim DN","year":"2015","unstructured":"Gherasim DN, Gory B, Sivan-Hoffmann R, Pierot L, Raoult H, Gauvrit JY, : Endovascular treatment of wide-neck anterior communicating artery aneurysms using WEB-DL and WEB-SL: short-term results in a multicenter study. AJNR Am J Neuroradiol 36:1150\u20131154, 201510.3174\/ajnr.A4282"},{"key":"b7","series-title":"Neuroradiology","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1007\/s00234-011-0891-x","article-title":"The Woven EndoBridge cerebral aneurysm embolization device (WEB II): initial clinical experience","volume":"53","author":"Klisch J","year":"2011","unstructured":"Klisch J, Sychra V, Strasilla C, Liebig T, Fiorella D: The Woven EndoBridge cerebral aneurysm embolization device (WEB II): initial clinical experience. Neuroradiology 53:599\u2013607, 201110.1007\/s00234-011-0891-x21617885"},{"key":"b8","series-title":"Zentralbl Neurochir","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1055\/s-2007-968164","article-title":"Neurosurgical management of previously coiled recurrent intracranial aneurysms","volume":"68","author":"K\u00f6nig RW","year":"2007","unstructured":"K\u00f6nig RW, Kretschmer T, Antoniadis G, Seitz K, Braun V, Richter HP, : Neurosurgical management of previously coiled recurrent intracranial aneurysms. Zentralbl Neurochir 68:8\u201313, 200710.1055\/s-2007-96816417487802"},{"key":"b9","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"432","DOI":"10.3174\/ajnr.A3869","article-title":"WEB-DL endovascular treatment of wide-neck bifurcation aneurysms: short- and midterm results in a European study","volume":"35","author":"Lubicz B","year":"2014","unstructured":"Lubicz B, Klisch J, Gauvrit JY, Szikora I, Leonardi M, Liebig T, : WEB-DL endovascular treatment of wide-neck bifurcation aneurysms: short- and midterm results in a European study. AJNR Am J Neuroradiol 35:432\u2013438, 201410.3174\/ajnr.A3869"},{"key":"b10","series-title":"J NeuroIntervent Surg [epub ahead of print]","article-title":"Endovascular treatment of intracranial aneurysms with the Woven EndoBridge device: mid term and long term results","author":"Mine B","year":"2017","unstructured":"Mine B, Goutte A, Brisbois D, Lubicz B: Endovascular treatment of intracranial aneurysms with the Woven EndoBridge device: mid term and long term results. J NeuroIntervent Surg [epub ahead of print], 2017"},{"key":"b11","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.3171\/2015.2.JNS142634","article-title":"Safety and efficacy of aneurysm treatment with WEB: results of the WEBCAST study","volume":"124","author":"Pierot L","year":"2016","unstructured":"Pierot L, Costalat V, Moret J, Szikora I, Klisch J, Herbreteau D, : Safety and efficacy of aneurysm treatment with WEB: results of the WEBCAST study. J Neurosurg 124:1250\u20131256, 20162638125310.3171\/2015.2.JNS142634"},{"key":"b12","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"2314","DOI":"10.3174\/ajnr.A4445","article-title":"WEB-DL endovascular treatment of wide-neck bifurcation aneurysms: long-term results in a European series","volume":"36","author":"Pierot L","year":"2015","unstructured":"Pierot L, Klisch J, Liebig T, Gauvrit JY, Leonardi M, Nuzzi NP, : WEB-DL endovascular treatment of wide-neck bifurcation aneurysms: long-term results in a European series. AJNR Am J Neuroradiol 36:2314\u20132319, 201510.3174\/ajnr.A4445"},{"key":"b13","series-title":"AJNR Am J Neuroradiol","doi-asserted-by":"publisher","first-page":"922","DOI":"10.3174\/ajnr.A4230","article-title":"WEB treatment of intracranial aneurysms: feasibility, complications, and 1-month safety results with the WEB DL and WEB SL\/SLS in the French Observatory","volume":"36","author":"Pierot L","year":"2015","unstructured":"Pierot L, Moret J, Turjman F, Herbreteau D, Raoult H, Barreau X, : WEB treatment of intracranial aneurysms: feasibility, complications, and 1-month safety results with the WEB DL and WEB SL\/SLS in the French Observatory. AJNR Am J Neuroradiol 36:922\u2013927, 20152565587610.3174\/ajnr.A4230"},{"key":"b14","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1227\/01.neu.0000333291.67362.0b","article-title":"Microsurgical clipping and endovascular coiling of intracranial aneurysms: a critical review of the literature","volume":"62","author":"Raja PV","year":"2008","unstructured":"Raja PV, Huang J, Germanwala AV, Gailloud P, Murphy KPJ, Tamargo RJ: Microsurgical clipping and endovascular coiling of intracranial aneurysms: a critical review of the literature. Neurosurgery 62:1187\u20131203, 200810.1227\/01.neu.0000333291.67362.0b18824986"},{"key":"b15","series-title":"Scott Med J","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1177\/003693305700200401","article-title":"Cerebral vascular accidents in patients over the age of 60. I. General considerations","volume":"2","author":"Rankin J","year":"1957","unstructured":"Rankin J: Cerebral vascular accidents in patients over the age of 60. I. General considerations. Scott Med J 2:127\u2013136, 195710.1177\/00369330570020040113432825"},{"key":"b16","series-title":"A case report. Interv Neuroradiol","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1177\/159101991201800214","article-title":"Coiling after treatment with the woven EndoBridge cerebral aneurysm embolization device","volume":"18","author":"Wallner AK","year":"2012","unstructured":"Wallner AK, Broussalis E, Hauser T, Trinka E, Killer-Oberpfalzer M: Coiling after treatment with the woven EndoBridge cerebral aneurysm embolization device. A case report. Interv Neuroradiol 18:208\u2013212, 201210.1177\/159101991201800214"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/130\/3\/article-p891.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/130\/3\/article-p891.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/130\/3\/article-p891.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T06:52:19Z","timestamp":1679813539000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/130\/3\/article-p891.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":16,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2017.10.jns171528","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}