{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T14:20:42Z","timestamp":1785853242413,"version":"3.56.0"},"reference-count":50,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,5]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Flow diversion has emerged as a viable treatment option for selected intracranial aneurysms and recently has been gaining traction. The aim of this study was to evaluate the safety and effectiveness of flow-diverter devices (FDDs) over a long-term follow-up period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>The authors retrospectively reviewed all cerebral aneurysm cases that had been admitted to the Division of Neurosurgery of the Universit\u00e0 degli Studi di Napoli between November 2008 and November 2015 and treated with an FDD. The records of 60 patients (48 females and 12 males) harboring 69 cerebral aneurysms were analyzed. The study end points were angiographic evidence of complete aneurysm occlusion, recanalization rate, occlusion of the parent artery, and clinical and radiological evidence of brain ischemia. The occlusion rate was evaluated according to the O\u2019Kelly-Marotta (OKM) Scale for flow diversion, based on the degree of filling (A, total filling; B, subtotal filling; C, entry remnant; D, no filling). Postprocedural, midterm, and long-term results were strictly analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>Complete occlusion (OKM D) was achieved in 63 (91%) of 69 aneurysms, partial occlusion (OKM C) in 4 (6%), occlusion of the parent artery in 2 (3%). Intraprocedural technical complications occurred in 3 patients (5%). Postprocedural complications occurred in 6 patients (10%), without neurological deficits. At the 12-month follow-up, 3 patients (5%) experienced asymptomatic cerebral infarction. No further complications were observed at later follow-up evaluations (&gt; 24 months). There were no reports of any delayed aneurysm rupture, subarachnoid or intraparenchymal hemorrhage, ischemic complications, or procedure- or device-related deaths.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>Endovascular treatment with an FDD is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. In the present study, the authors observed effective and stable aneurysm occlusion, even at the long-term follow-up. Data in this study also suggest that ischemic complications can occur at a later stage, particularly at 12\u201318 months. On the other hand, no other ischemic or hemorrhagic complications occurred beyond 24 months.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2017.3.focus1732","type":"journal-article","created":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T03:36:47Z","timestamp":1496288207000},"page":"E3","source":"Crossref","is-referenced-by-count":53,"title":["Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center"],"prefix":"10.3171","volume":"42","author":[{"given":"Francesco","family":"Briganti","sequence":"first","affiliation":[{"name":"Unit of Interventional Neuroradiology, Department of Advanced Biomedical Sciences;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Leone","sequence":"additional","affiliation":[{"name":"Department of Advanced Biomedical Sciences;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luigi","family":"Cirillo","sequence":"additional","affiliation":[{"name":"Neuroradiology Department, IRCCS Institute of Neurological Sciences of Bologna, Bellaria Hospital, Bologna, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oreste","family":"de Divitiis","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Universit\u00e0 degli Studi di Napoli Federico II, Napoli; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico","family":"Solari","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Universit\u00e0 degli Studi di Napoli Federico II, Napoli; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Cappabianca","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Universit\u00e0 degli Studi di Napoli Federico II, Napoli; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Neurosurgery","first-page":"193","article-title":"Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis","volume":"73","author":"Arrese I","year":"2013","unstructured":"Arrese I, Sarabia R, Pintado R, Delgado-Rodriguez M: Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis. Neurosurgery 73:193\u2013200, 2013"},{"key":"b2","series-title":"AJNR Am J Neuroradiol","first-page":"1150","article-title":"Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study","volume":"33","author":"Berge J","year":"2012","unstructured":"Berge J, Biondi A, Machi P, Brunel H, Pierot L, Gabrillargues J, : Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study. AJNR Am J Neuroradiol 33:1150\u20131155, 2012"},{"key":"b3","series-title":"J Neurointerv Surg","first-page":"287","article-title":"Flow diverter device for the treatment of small middle cerebral artery aneurysms","volume":"8","author":"Briganti F","year":"2016","unstructured":"Briganti F, Delehaye L, Leone G, Sicignano C, Buono G, Marseglia M, : Flow diverter device for the treatment of small middle cerebral artery aneurysms. J Neurointerv Surg 8:287\u2013294, 2016"},{"key":"b4","series-title":"Neuroradiol J","first-page":"365","article-title":"Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review","volume":"28","author":"Briganti F","year":"2015","unstructured":"Briganti F, Leone G, Marseglia M, Mariniello G, Caranci F, Brunetti A, : Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review. Neuroradiol J 28:365\u2013375, 2015"},{"key":"b5","series-title":"J Neurointerv Surg","first-page":"70","article-title":"Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience","volume":"9","author":"Briganti F","year":"2017","unstructured":"Briganti F, Leone G, Ugga L, Marseglia M, Macera A, Manto A, : Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience. J Neurointerv Surg 9:70\u201376, 2017"},{"key":"b6","series-title":"Acta Neurochir (Wien)","first-page":"1745","article-title":"Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience","volume":"158","author":"Briganti F","year":"2016","unstructured":"Briganti F, Leone G, Ugga L, Marseglia M, Solari D, Caranci F, : Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience. Acta Neurochir (Wien) 158:1745\u20131755, 2016"},{"key":"b7","series-title":"Eur J Radiol","first-page":"1683","article-title":"Treatment of intracranial aneurysms by flow diverter devices: long-term results from a single center","volume":"83","author":"Briganti F","year":"2014","unstructured":"Briganti F, Napoli M, Leone G, Marseglia M, Mariniello G, Caranci F, : Treatment of intracranial aneurysms by flow diverter devices: long-term results from a single center. Eur J Radiol 83:1683\u20131690, 2014"},{"key":"b8","series-title":"Neuroradiology","first-page":"1145","article-title":"Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications\u2014a retrospective data analysis","volume":"54","author":"Briganti F","year":"2012","unstructured":"Briganti F, Napoli M, Tortora F, Solari D, Bergui M, Boccardi E, : Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications\u2014a retrospective data analysis. Neuroradiology 54:1145\u20131152, 2012"},{"key":"b9","series-title":"AJNR Am J Neuroradiol","first-page":"1673","article-title":"Risk factors for ischemic complications following pipeline embolization device treatment of intracranial aneurysms: results from the IntrePED Study","volume":"37","author":"Brinjikji W","year":"2016","unstructured":"Brinjikji W, Lanzino G, Cloft HJ, Siddiqui AH, Boccardi E, Cekirge S, : Risk factors for ischemic complications following pipeline embolization device treatment of intracranial aneurysms: results from the IntrePED Study. AJNR Am J Neuroradiol 37:1673\u20131678, 2016"},{"key":"b10","series-title":"Stroke","first-page":"442","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji W","year":"2013","unstructured":"Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF: Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke 44:442\u2013447, 2013"},{"key":"b11","series-title":"Neurosurgery","first-page":"944","article-title":"Cost comparison of endovascular treatment of anterior circulation aneurysms with the pipeline embolization device and stent-assisted coiling","volume":"71","author":"Colby GP","year":"2012","unstructured":"Colby GP, Lin LM, Paul AR, Huang J, Tamargo RJ, Coon AL: Cost comparison of endovascular treatment of anterior circulation aneurysms with the pipeline embolization device and stent-assisted coiling. Neurosurgery 71:944\u2013950, 2012"},{"key":"b12","series-title":"J Neurointerv Surg","first-page":"919","article-title":"Endovascular treatment of ophthalmic artery aneurysms: ophthalmic artery patency following flow diversion versus coil embolization","volume":"8","author":"Durst CR","year":"2016","unstructured":"Durst CR, Starke RM, Clopton D, Hixson HR, Schmitt PJ, Gingras JM, : Endovascular treatment of ophthalmic artery aneurysms: ophthalmic artery patency following flow diversion versus coil embolization. J Neurointerv Surg 8:919\u2013922, 2016"},{"key":"b13","series-title":"Neuroradiology","first-page":"369","article-title":"Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections","volume":"54","author":"Fischer S","year":"2012","unstructured":"Fischer S, Vajda Z, Aguilar Perez M, Schmid E, Hopf N, B\u00e4zner H, : Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections. Neuroradiology 54:369\u2013382, 2012"},{"key":"b14","series-title":"J Neurointerv Surg","first-page":"481","article-title":"Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: a single-center series with special emphasis on covered cortical branches and perforating arteries","volume":"8","author":"Gawlitza M","year":"2016","unstructured":"Gawlitza M, Januel AC, Tall P, Bonneville F, Cognard C: Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: a single-center series with special emphasis on covered cortical branches and perforating arteries. J Neurointerv Surg 8:481\u2013487, 2016"},{"key":"b15","series-title":"Stroke","first-page":"2346","article-title":"A new endoluminal, flow-disrupting device for treatment of saccular aneurysms","volume":"38","author":"Kallmes DF","year":"2007","unstructured":"Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA, Cloft HJ: A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 38:2346\u20132352, 2007"},{"key":"b16","series-title":"AJNR Am J Neuroradiol","first-page":"2158","article-title":"Efficacy and safety of flow diversion for paraclinoid aneurysms: a matched-pair analysis compared with standard endovascular approaches","volume":"33","author":"Lanzino G","year":"2012","unstructured":"Lanzino G, Crobeddu E, Cloft HJ, Hanel R, Kallmes DF: Efficacy and safety of flow diversion for paraclinoid aneurysms: a matched-pair analysis compared with standard endovascular approaches. AJNR Am J Neuroradiol 33:2158\u20132161, 2012"},{"key":"b17","series-title":"AJNR Am J Neuroradiol","first-page":"542","article-title":"Silk flow-diverter stent for the treatment of intracranial aneurysms: a series of 58 patients with emphasis on long-term results","volume":"36","author":"Lubicz B","year":"2015","unstructured":"Lubicz B, Van der Elst O, Collignon L, Mine B, Alghamdi F: Silk flow-diverter stent for the treatment of intracranial aneurysms: a series of 58 patients with emphasis on long-term results. AJNR Am J Neuroradiol 36:542\u2013546, 2015"},{"key":"b18","series-title":"Acta Neurochir (Wien)","first-page":"979","article-title":"Treatment of intra-cranial aneurysms with the SILK flow diverter: 2 years\u2019 experience with 28 patients at a single center","volume":"154","author":"Maimon S","year":"2012","unstructured":"Maimon S, Gonen L, Nossek E, Strauss I, Levite R, Ram Z: Treatment of intra-cranial aneurysms with the SILK flow diverter: 2 years\u2019 experience with 28 patients at a single center. Acta Neurochir (Wien) 154:979\u2013987, 2012"},{"key":"b19","series-title":"J Neurointerv Surg","first-page":"396","article-title":"Endovascular treatment of intracranial aneurysms using the Pipeline Flex embolization device: a case series of 30 consecutive patients","volume":"8","author":"Mart\u00ednez-Gald\u00e1mez M","year":"2016","unstructured":"Mart\u00ednez-Gald\u00e1mez M, P\u00e9rez S, Vega A, Ruiz P, Caniego JL, B\u00e1rcena E, : Endovascular treatment of intracranial aneurysms using the Pipeline Flex embolization device: a case series of 30 consecutive patients. J Neurointerv Surg 8:396\u2013401, 2016"},{"key":"b20","series-title":"Interv Neuroradiol","first-page":"133","article-title":"A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents","volume":"16","author":"O\u2019Kelly CJ","year":"2010","unstructured":"O\u2019Kelly CJ, Krings T, Fiorella D, Marotta TR: A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol 16:133\u2013137, 2010"},{"key":"b21","series-title":"AJNR Am J Neuroradiol","first-page":"948","article-title":"Treatment of cavernous sinus aneurysms with flow diversion: results in 44 patients","volume":"35","author":"Puffer RC","year":"2014","unstructured":"Puffer RC, Piano M, Lanzino G, Valvassori L, Kallmes DF, Quilici L, : Treatment of cavernous sinus aneurysms with flow diversion: results in 44 patients. AJNR Am J Neuroradiol 35:948\u2013951, 2014"},{"key":"b22","series-title":"AJNR Am J Neuroradiol","first-page":"1436","article-title":"Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results","volume":"33","author":"Saatci I","year":"2012","unstructured":"Saatci I, Yavuz K, Ozer C, Geyik S, Cekirge HS: Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results. AJNR Am J Neuroradiol 33:1436\u20131446, 2012"},{"key":"b23","series-title":"J Neurointerv Surg","first-page":"273","article-title":"SILK flow diverter for complex intracranial aneurysms: a Canadian registry","volume":"8","author":"Shankar JJ","year":"2016","unstructured":"Shankar JJ, Tampieri D, Iancu D, Cortes M, Agid R, Krings T, : SILK flow diverter for complex intracranial aneurysms: a Canadian registry. J Neurointerv Surg 8:273\u2013278, 2016"},{"key":"b24","series-title":"Neuroradiology","first-page":"709","article-title":"Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent","volume":"54","author":"Wagner A","year":"2012","unstructured":"Wagner A, Cortsen M, Hauerberg J, Romner B, Wagner MP: Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent. Neuroradiology 54:709\u2013718, 2012"},{"key":"b25","series-title":"Radiology","first-page":"893","article-title":"Intracranial aneurysms: midterm outcome of pipeline embolization device\u2014a prospective study in 143 patients with 178 aneurysms","volume":"265","author":"Yu SC","year":"2012","unstructured":"Yu SC, Kwok CK, Cheng PW, Chan KY, Lau SS, Lui WM, : Intracranial aneurysms: midterm outcome of pipeline embolization device\u2014a prospective study in 143 patients with 178 aneurysms. Radiology 265:893\u2013901, 2012"},{"key":"b1","series-title":"Neurosurgery","first-page":"193","article-title":"Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis","volume":"73","author":"Arrese I","year":"2013","unstructured":"Arrese I, Sarabia R, Pintado R, Delgado-Rodriguez M: Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis. Neurosurgery 73:193\u2013200, 2013"},{"key":"b2","series-title":"AJNR Am J Neuroradiol","first-page":"1150","article-title":"Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study","volume":"33","author":"Berge J","year":"2012","unstructured":"Berge J, Biondi A, Machi P, Brunel H, Pierot L, Gabrillargues J, : Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study. AJNR Am J Neuroradiol 33:1150\u20131155, 2012"},{"key":"b3","series-title":"J Neurointerv Surg","first-page":"287","article-title":"Flow diverter device for the treatment of small middle cerebral artery aneurysms","volume":"8","author":"Briganti F","year":"2016","unstructured":"Briganti F, Delehaye L, Leone G, Sicignano C, Buono G, Marseglia M, : Flow diverter device for the treatment of small middle cerebral artery aneurysms. J Neurointerv Surg 8:287\u2013294, 2016"},{"key":"b4","series-title":"Neuroradiol J","first-page":"365","article-title":"Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review","volume":"28","author":"Briganti F","year":"2015","unstructured":"Briganti F, Leone G, Marseglia M, Mariniello G, Caranci F, Brunetti A, : Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review. Neuroradiol J 28:365\u2013375, 2015"},{"key":"b5","series-title":"J Neurointerv Surg","first-page":"70","article-title":"Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience","volume":"9","author":"Briganti F","year":"2017","unstructured":"Briganti F, Leone G, Ugga L, Marseglia M, Macera A, Manto A, : Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience. J Neurointerv Surg 9:70\u201376, 2017"},{"key":"b6","series-title":"Acta Neurochir (Wien)","first-page":"1745","article-title":"Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience","volume":"158","author":"Briganti F","year":"2016","unstructured":"Briganti F, Leone G, Ugga L, Marseglia M, Solari D, Caranci F, : Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience. Acta Neurochir (Wien) 158:1745\u20131755, 2016"},{"key":"b7","series-title":"Eur J Radiol","first-page":"1683","article-title":"Treatment of intracranial aneurysms by flow diverter devices: long-term results from a single center","volume":"83","author":"Briganti F","year":"2014","unstructured":"Briganti F, Napoli M, Leone G, Marseglia M, Mariniello G, Caranci F, : Treatment of intracranial aneurysms by flow diverter devices: long-term results from a single center. Eur J Radiol 83:1683\u20131690, 2014"},{"key":"b8","series-title":"Neuroradiology","first-page":"1145","article-title":"Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications\u2014a retrospective data analysis","volume":"54","author":"Briganti F","year":"2012","unstructured":"Briganti F, Napoli M, Tortora F, Solari D, Bergui M, Boccardi E, : Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications\u2014a retrospective data analysis. Neuroradiology 54:1145\u20131152, 2012"},{"key":"b9","series-title":"AJNR Am J Neuroradiol","first-page":"1673","article-title":"Risk factors for ischemic complications following pipeline embolization device treatment of intracranial aneurysms: results from the IntrePED Study","volume":"37","author":"Brinjikji W","year":"2016","unstructured":"Brinjikji W, Lanzino G, Cloft HJ, Siddiqui AH, Boccardi E, Cekirge S, : Risk factors for ischemic complications following pipeline embolization device treatment of intracranial aneurysms: results from the IntrePED Study. AJNR Am J Neuroradiol 37:1673\u20131678, 2016"},{"key":"b10","series-title":"Stroke","first-page":"442","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji W","year":"2013","unstructured":"Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF: Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke 44:442\u2013447, 2013"},{"key":"b11","series-title":"Neurosurgery","first-page":"944","article-title":"Cost comparison of endovascular treatment of anterior circulation aneurysms with the pipeline embolization device and stent-assisted coiling","volume":"71","author":"Colby GP","year":"2012","unstructured":"Colby GP, Lin LM, Paul AR, Huang J, Tamargo RJ, Coon AL: Cost comparison of endovascular treatment of anterior circulation aneurysms with the pipeline embolization device and stent-assisted coiling. Neurosurgery 71:944\u2013950, 2012"},{"key":"b12","series-title":"J Neurointerv Surg","first-page":"919","article-title":"Endovascular treatment of ophthalmic artery aneurysms: ophthalmic artery patency following flow diversion versus coil embolization","volume":"8","author":"Durst CR","year":"2016","unstructured":"Durst CR, Starke RM, Clopton D, Hixson HR, Schmitt PJ, Gingras JM, : Endovascular treatment of ophthalmic artery aneurysms: ophthalmic artery patency following flow diversion versus coil embolization. J Neurointerv Surg 8:919\u2013922, 2016"},{"key":"b13","series-title":"Neuroradiology","first-page":"369","article-title":"Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections","volume":"54","author":"Fischer S","year":"2012","unstructured":"Fischer S, Vajda Z, Aguilar Perez M, Schmid E, Hopf N, B\u00e4zner H, : Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections. Neuroradiology 54:369\u2013382, 2012"},{"key":"b14","series-title":"J Neurointerv Surg","first-page":"481","article-title":"Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: a single-center series with special emphasis on covered cortical branches and perforating arteries","volume":"8","author":"Gawlitza M","year":"2016","unstructured":"Gawlitza M, Januel AC, Tall P, Bonneville F, Cognard C: Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: a single-center series with special emphasis on covered cortical branches and perforating arteries. J Neurointerv Surg 8:481\u2013487, 2016"},{"key":"b15","series-title":"Stroke","first-page":"2346","article-title":"A new endoluminal, flow-disrupting device for treatment of saccular aneurysms","volume":"38","author":"Kallmes DF","year":"2007","unstructured":"Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA, Cloft HJ: A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 38:2346\u20132352, 2007"},{"key":"b16","series-title":"AJNR Am J Neuroradiol","first-page":"2158","article-title":"Efficacy and safety of flow diversion for paraclinoid aneurysms: a matched-pair analysis compared with standard endovascular approaches","volume":"33","author":"Lanzino G","year":"2012","unstructured":"Lanzino G, Crobeddu E, Cloft HJ, Hanel R, Kallmes DF: Efficacy and safety of flow diversion for paraclinoid aneurysms: a matched-pair analysis compared with standard endovascular approaches. AJNR Am J Neuroradiol 33:2158\u20132161, 2012"},{"key":"b17","series-title":"AJNR Am J Neuroradiol","first-page":"542","article-title":"Silk flow-diverter stent for the treatment of intracranial aneurysms: a series of 58 patients with emphasis on long-term results","volume":"36","author":"Lubicz B","year":"2015","unstructured":"Lubicz B, Van der Elst O, Collignon L, Mine B, Alghamdi F: Silk flow-diverter stent for the treatment of intracranial aneurysms: a series of 58 patients with emphasis on long-term results. AJNR Am J Neuroradiol 36:542\u2013546, 2015"},{"key":"b18","series-title":"Acta Neurochir (Wien)","first-page":"979","article-title":"Treatment of intra-cranial aneurysms with the SILK flow diverter: 2 years\u2019 experience with 28 patients at a single center","volume":"154","author":"Maimon S","year":"2012","unstructured":"Maimon S, Gonen L, Nossek E, Strauss I, Levite R, Ram Z: Treatment of intra-cranial aneurysms with the SILK flow diverter: 2 years\u2019 experience with 28 patients at a single center. Acta Neurochir (Wien) 154:979\u2013987, 2012"},{"key":"b19","series-title":"J Neurointerv Surg","first-page":"396","article-title":"Endovascular treatment of intracranial aneurysms using the Pipeline Flex embolization device: a case series of 30 consecutive patients","volume":"8","author":"Mart\u00ednez-Gald\u00e1mez M","year":"2016","unstructured":"Mart\u00ednez-Gald\u00e1mez M, P\u00e9rez S, Vega A, Ruiz P, Caniego JL, B\u00e1rcena E, : Endovascular treatment of intracranial aneurysms using the Pipeline Flex embolization device: a case series of 30 consecutive patients. J Neurointerv Surg 8:396\u2013401, 2016"},{"key":"b20","series-title":"Interv Neuroradiol","first-page":"133","article-title":"A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents","volume":"16","author":"O\u2019Kelly CJ","year":"2010","unstructured":"O\u2019Kelly CJ, Krings T, Fiorella D, Marotta TR: A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol 16:133\u2013137, 2010"},{"key":"b21","series-title":"AJNR Am J Neuroradiol","first-page":"948","article-title":"Treatment of cavernous sinus aneurysms with flow diversion: results in 44 patients","volume":"35","author":"Puffer RC","year":"2014","unstructured":"Puffer RC, Piano M, Lanzino G, Valvassori L, Kallmes DF, Quilici L, : Treatment of cavernous sinus aneurysms with flow diversion: results in 44 patients. AJNR Am J Neuroradiol 35:948\u2013951, 2014"},{"key":"b22","series-title":"AJNR Am J Neuroradiol","first-page":"1436","article-title":"Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results","volume":"33","author":"Saatci I","year":"2012","unstructured":"Saatci I, Yavuz K, Ozer C, Geyik S, Cekirge HS: Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results. AJNR Am J Neuroradiol 33:1436\u20131446, 2012"},{"key":"b23","series-title":"J Neurointerv Surg","first-page":"273","article-title":"SILK flow diverter for complex intracranial aneurysms: a Canadian registry","volume":"8","author":"Shankar JJ","year":"2016","unstructured":"Shankar JJ, Tampieri D, Iancu D, Cortes M, Agid R, Krings T, : SILK flow diverter for complex intracranial aneurysms: a Canadian registry. J Neurointerv Surg 8:273\u2013278, 2016"},{"key":"b24","series-title":"Neuroradiology","first-page":"709","article-title":"Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent","volume":"54","author":"Wagner A","year":"2012","unstructured":"Wagner A, Cortsen M, Hauerberg J, Romner B, Wagner MP: Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent. Neuroradiology 54:709\u2013718, 2012"},{"key":"b25","series-title":"Radiology","first-page":"893","article-title":"Intracranial aneurysms: midterm outcome of pipeline embolization device\u2014a prospective study in 143 patients with 178 aneurysms","volume":"265","author":"Yu SC","year":"2012","unstructured":"Yu SC, Kwok CK, Cheng PW, Chan KY, Lau SS, Lui WM, : Intracranial aneurysms: midterm outcome of pipeline embolization device\u2014a prospective study in 143 patients with 178 aneurysms. Radiology 265:893\u2013901, 2012"}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/42\/6\/article-pE3.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/42\/6\/article-pE3.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/42\/6\/article-pE3.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T08:19:29Z","timestamp":1780733969000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/42\/6\/article-pE3.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5]]},"references-count":50,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2017.3.focus1732","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5]]}}}