{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T00:32:42Z","timestamp":1768264362921,"version":"3.49.0"},"reference-count":37,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:p>Pedicle and lateral mass screws are the most common means of rigid fixation in posterior cervical spine fusions. Various other techniques such as translaminar screw placement, paravertebral foramen screw fixation, sublaminar and spinous process wiring, cement augmentation, and others have been developed for primary fixation or as salvage methods. Use of these techniques can be limited by a prior history of osteotomies, poor bone density, destruction of the bone-screw interface, and unfavorable vascular and osseous anatomy.<\/jats:p><jats:p>Here, the authors report on the novel application of cervical sublaminar polyester bands as an adjunct salvage method or additional fixation point used with traditional methods in the revision of prior constructs. While sublaminar polyester bands have been used for decades in pediatric scoliosis surgery in the thoracolumbar spine, they have yet to be utilized as a method of fixation in the cervical spine. In both cases described here, sublaminar banding proved crucial for fixation points where traditional fixation techniques would have been less than ideal. Further study is required to determine the full application of sublaminar polyester bands in the cervical spine as well as its outcomes.<\/jats:p>","DOI":"10.3171\/2018.12.spine181147","type":"journal-article","created":{"date-parts":[[2019,4,9]],"date-time":"2019-04-09T20:02:51Z","timestamp":1554840171000},"page":"772-776","source":"Crossref","is-referenced-by-count":2,"title":["Sublaminar polyester bands as a salvage fixation method in the cervical spine: novel application in two patients"],"prefix":"10.3171","volume":"30","author":[{"given":"Luke G. F.","family":"Smith","sequence":"first","affiliation":[{"name":"Department of Neurological Surgery, Ohio State University, Wexner Medical Center; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nguyen","family":"Hoang","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Ohio State University, Wexner Medical Center; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ammar","family":"Shaikhouni","sequence":"additional","affiliation":[{"name":"Division of Neurological Surgery, Nationwide Children\u2019s Hospital, Columbus, Ohio"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanus","family":"Viljoen","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Ohio State University, Wexner Medical Center; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1","series-title":"J Spinal Disord","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1097\/00002517-199407010-00003","article-title":"Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report","volume":"7","author":"Abumi K","year":"1994","unstructured":"Abumi K, Itoh H, Taneichi H, Kaneda K: Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7:19\u201328, 1994818658510.1097\/00002517-199407010-00003"},{"key":"b2","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1732","DOI":"10.1007\/s00586-016-4838-0","article-title":"Titanium vs cobalt chromium: what is the best rod material to enhance adolescent idiopathic scoliosis correction with sublaminar bands?","volume":"26","author":"Angelliaume A","year":"2017","unstructured":"Angelliaume A, Ferrero E, Mazda K, Le Hanneur M, Accabled F, de Gauzy JS, : Titanium vs cobalt chromium: what is the best rod material to enhance adolescent idiopathic scoliosis correction with sublaminar bands? Eur Spine J 26:1732\u20131738, 20172781713710.1007\/s00586-016-4838-0"},{"key":"b3","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"893","DOI":"10.3171\/jns.1989.70.6.0893","article-title":"Posterior cervical interspinous compression wiring and fusion for mid to low cervical spinal injuries","volume":"70","author":"Benzel EC","year":"1989","unstructured":"Benzel EC, Kesterson L: Posterior cervical interspinous compression wiring and fusion for mid to low cervical spinal injuries. J Neurosurg 70:893\u2013899, 198910.3171\/jns.1989.70.6.08932715817"},{"key":"b4","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"125","DOI":"10.3171\/2016.6.SPINE151477","article-title":"The effect of posterior polyester tethers on the biomechanics of proximal junctional kyphosis: a finite element analysis","volume":"26","author":"Bess S","year":"2017","unstructured":"Bess S, Harris JE, Turner AW, LaFage V, Smith JS, Shaffrey CI, : The effect of posterior polyester tethers on the biomechanics of proximal junctional kyphosis: a finite element analysis. J Neurosurg Spine 26:125\u2013133, 201710.3171\/2016.6.SPINE15147727611508"},{"key":"b5","series-title":"J Bone Joint Surg Am","doi-asserted-by":"publisher","first-page":"2136","DOI":"10.2106\/JBJS.L.01522","article-title":"Lateral mass screw fixation in the cervical spine: a systematic literature review","volume":"95","author":"Coe JD","year":"2013","unstructured":"Coe JD, Vaccaro AR, Dailey AT, Skolasky RL Jr, Sasso RC, Ludwig SC, : Lateral mass screw fixation in the cervical spine: a systematic literature review. J Bone Joint Surg Am 95:2136\u20132143, 201310.2106\/JBJS.L.0152224306701"},{"key":"b6","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1016\/j.spinee.2005.08.015","article-title":"Biomechanical evaluation of pedicle screws versus pedicle and laminar hooks in the thoracic spine","volume":"6","author":"Cordista A","year":"2006","unstructured":"Cordista A, Conrad B, Horodyski M, Walters S, Rechtine G: Biomechanical evaluation of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Spine J 6:444\u2013449, 20061682505310.1016\/j.spinee.2005.08.015"},{"key":"b7","series-title":"J Neurosurg Pediatr","doi-asserted-by":"publisher","first-page":"328","DOI":"10.3171\/2014.9.PEDS1468","article-title":"The feasibility and safety of using sublaminar polyester bands in hybrid spinal constructs in children and transitional adults for neuromuscular scoliosis","volume":"15","author":"Desai SK","year":"2015","unstructured":"Desai SK, Sayama C, Vener D, Brayton A, Brice\u00f1o V, Luerssen TG, : The feasibility and safety of using sublaminar polyester bands in hybrid spinal constructs in children and transitional adults for neuromuscular scoliosis. J Neurosurg Pediatr 15:328\u2013337, 201510.3171\/2014.9.PEDS146825555118"},{"key":"b8","series-title":"Orthop Clin North Am","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.ocl.2013.01.008","article-title":"Surgical stabilization of the spine in the osteoporotic patient","volume":"44","author":"Dodwad SM","year":"2013","unstructured":"Dodwad SM, Khan SN: Surgical stabilization of the spine in the osteoporotic patient. Orthop Clin North Am 44:243\u2013249, 20132354482710.1016\/j.ocl.2013.01.008"},{"key":"b9","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1007\/s00701-009-0495-y","article-title":"Universal Clamp system in thoracolumbar spinal fixation: technical note","volume":"151","author":"Gazzeri R","year":"2009","unstructured":"Gazzeri R, Faiola A, Galarza M, Tamorri M: Universal Clamp system in thoracolumbar spinal fixation: technical note. Acta Neurochir (Wien) 151:1673\u20131680, 20091972754510.1007\/s00701-009-0495-y"},{"key":"b10","series-title":"Surg Neurol","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1016\/0090-3019(85)90017-5","article-title":"Complications of sublaminar wiring","volume":"23","author":"Geremia GK","year":"1985","unstructured":"Geremia GK, Kim KS, Cerullo L, Calenoff L: Complications of sublaminar wiring. Surg Neurol 23:629\u2013635, 198510.1016\/0090-3019(85)90017-53992467"},{"key":"b11","series-title":"Cureus","first-page":"e338","article-title":"Posterior fixation techniques in the subaxial cervical spine","volume":"7","author":"Ghori A","year":"2015","unstructured":"Ghori A, Le HV, Makanji H, Cha T: Posterior fixation techniques in the subaxial cervical spine. Cureus 7:e338, 201526594602"},{"key":"b12","series-title":"J Bone Joint Surg Br","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1302\/0301-620X.49B1.33","article-title":"Occipito-cervical fusion. Indications, technique and results","volume":"49","author":"Hamblen DL","year":"1967","unstructured":"Hamblen DL: Occipito-cervical fusion. Indications, technique and results. J Bone Joint Surg Br 49:33\u201345, 1967496001010.1302\/0301-620X.49B1.33"},{"key":"b13","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2427","DOI":"10.1097\/00007632-200111150-00006","article-title":"A comparison of three screw types for unicortical fixation in the lateral mass of the cervical spine","volume":"26","author":"Harris BM","year":"2001","unstructured":"Harris BM, Hilibrand AS, Nien YH, Nachwalter R, Vaccaro A, Albert TJ, : A comparison of three screw types for unicortical fixation in the lateral mass of the cervical spine. Spine (Phila Pa 1976) 26:2427\u20132431, 200110.1097\/00007632-200111150-0000611707704"},{"key":"b14","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1739","DOI":"10.1097\/BRS.0b013e31817d2aa2","article-title":"Significance of laminar screw fixation in the subaxial cervical spine","volume":"33","author":"Hong JT","year":"2008","unstructured":"Hong JT, Sung JH, Son BC, Lee SW, Park CK: Significance of laminar screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976) 33:1739\u20131743, 200810.1097\/BRS.0b013e31817d2aa218628706"},{"key":"b15","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.1007\/s00586-009-0999-4","article-title":"Biomechanical evaluation of a new fixation device for the thoracic spine","volume":"18","author":"Hongo M","year":"2009","unstructured":"Hongo M, Ilharreborde B, Gay RE, Zhao C, Zhao KD, Berglund LJ, : Biomechanical evaluation of a new fixation device for the thoracic spine. Eur Spine J 18:1213\u20131219, 20091940468710.1007\/s00586-009-0999-4"},{"key":"b16","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1097\/BRS.0b013e3181b7c7c4","article-title":"Hybrid constructs for tridimensional correction of the thoracic spine in adolescent idiopathic scoliosis: a comparative analysis of universal clamps versus hooks","volume":"35","author":"Ilharreborde B","year":"2010","unstructured":"Ilharreborde B, Even J, Lefevre Y, Fitoussi F, Presedo A, Penne\u00e7ot GF, : Hybrid constructs for tridimensional correction of the thoracic spine in adolescent idiopathic scoliosis: a comparative analysis of universal clamps versus hooks. Spine (Phila Pa 1976) 35:306\u2013314, 201010.1097\/BRS.0b013e3181b7c7c420075778"},{"key":"b17","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"E1203","DOI":"10.1227\/01.NEU.0000369198.70959.E1","article-title":"Intracranial hemorrhage and spinal cord injury from a fractured C1-C2 sublaminar cable: case report","volume":"66","author":"Kakarla UK","year":"2010","unstructured":"Kakarla UK, Valdivia JV, Sonntag VK, Bambakidis NC: Intracranial hemorrhage and spinal cord injury from a fractured C1-C2 sublaminar cable: case report. Neurosurgery 66:E1203\u2013E1204, 201010.1227\/01.NEU.0000369198.70959.E1"},{"key":"b18","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"631","DOI":"10.3171\/jns.1995.83.4.0631","article-title":"Posterior cervical spine fusion with tension-band wiring","volume":"83","author":"Lovely TJ","year":"1995","unstructured":"Lovely TJ, Carl A: Posterior cervical spine fusion with tension-band wiring. J Neurosurg 83:631\u2013635, 1995767401210.3171\/jns.1995.83.4.0631"},{"key":"b19","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2675","DOI":"10.1097\/00007632-200010150-00022","article-title":"Cervical pedicle screws: comparative accuracy of two insertion techniques","volume":"25","author":"Ludwig SC","year":"2000","unstructured":"Ludwig SC, Kowalski JM, Edwards CC II, Heller JG: Cervical pedicle screws: comparative accuracy of two insertion techniques. Spine (Phila Pa 1976) 25:2675\u20132681, 20001103465610.1097\/00007632-200010150-00022"},{"key":"b20","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1097\/00007632-200007010-00009","article-title":"Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques","volume":"25","author":"Ludwig SC","year":"2000","unstructured":"Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ: Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine (Phila Pa 1976) 25:1655\u20131667, 20001087014110.1097\/00007632-200007010-00009"},{"key":"b21","series-title":"Clin Orthop Relat Res","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1097\/00003086-199902000-00009","article-title":"Transpedicle screw fixation of the cervical spine","volume":"359","author":"Ludwig SC","year":"1999","unstructured":"Ludwig SC, Kramer DL, Vaccaro AR, Albert TJ: Transpedicle screw fixation of the cervical spine. Clin Orthop Relat Res (359):77\u201388, 199910.1097\/00003086-199902000-00009"},{"key":"b22","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1227\/00006123-199001000-00004","article-title":"Craniocervical stabilization using Luque\/Hartshill rectangles","volume":"26","author":"MacKenzie AI","year":"1990","unstructured":"MacKenzie AI, Uttley D, Marsh HT, Bell BA: Craniocervical stabilization using Luque\/Hartshill rectangles. Neurosurgery 26:32\u201336, 199010.1227\/00006123-199001000-000042294476"},{"key":"b23","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2240","DOI":"10.1097\/00007632-199311000-00016","article-title":"Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability","volume":"18","author":"Okuyama K","year":"1993","unstructured":"Okuyama K, Sato K, Abe E, Inaba H, Shimada Y, Murai H: Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability. Spine (Phila Pa 1976) 18:2240\u20132245, 199310.1097\/00007632-199311000-00016"},{"issue":"1","key":"b24","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.3171\/foc.2004.16.1.11","article-title":"History of instrumentation for stabilization of the subaxial cervical spine","volume":"16","author":"Omeis I","year":"2004","unstructured":"Omeis I, DeMattia JA, Hillard VH, Murali R, Das K: History of instrumentation for stabilization of the subaxial cervical spine. Neurosurg Focus 16(1):E10, 200410.3171\/foc.2004.16.1.1115264788"},{"key":"b25","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1097\/00007632-199702010-00007","article-title":"The biomechanical analysis of sublaminar wires and cables using luque segmental spinal instrumentation","volume":"22","author":"Parsons JR","year":"1997","unstructured":"Parsons JR, Chokshi BV, Lee CK, Gundlapalli RV, Stamer D: The biomechanical analysis of sublaminar wires and cables using luque segmental spinal instrumentation. Spine (Phila Pa 1976) 22:267\u2013273, 199710.1097\/00007632-199702010-000079051888"},{"key":"b26","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1007\/s00586-014-3594-2","article-title":"Sublaminar bands: are they safe?","volume":"24","author":"Polirsztok E","year":"2015","unstructured":"Polirsztok E, Gavaret M, Gsell T, Suprano I, Choufani E, Bollini G, : Sublaminar bands: are they safe? Eur Spine J 24:1441\u20131449, 201510.1007\/s00586-014-3594-225291975"},{"key":"b27","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"324","DOI":"10.3171\/jns.1995.83.2.0324","article-title":"Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws","volume":"83","author":"Ryken TC","year":"1995","unstructured":"Ryken TC, Clausen JD, Traynelis VC, Goel VK: Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws. J Neurosurg 83:324\u2013329, 19952830638110.3171\/jns.1995.83.2.0324"},{"key":"b28","series-title":"Br J Neurosurg","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1080\/0268869021000030302","article-title":"Craniocervical fusion for rheumatoid arthritis: comparison of sublaminar wires and the lateral mass screw craniocervical fusion","volume":"16","author":"Shad A","year":"2002","unstructured":"Shad A, Shariff SS, Teddy PJ, Cadoux-Hudson TA: Craniocervical fusion for rheumatoid arthritis: comparison of sublaminar wires and the lateral mass screw craniocervical fusion. Br J Neurosurg 16:483\u2013486, 200210.1080\/026886902100003030212498493"},{"key":"b29","series-title":"Clin Neurosurg","first-page":"243","article-title":"Craniocervical stabilization","volume":"40","author":"Sonntag VK","year":"1993","unstructured":"Sonntag VK, Dickman CA: Craniocervical stabilization. Clin Neurosurg 40:243\u2013272, 19938111986"},{"key":"b30","series-title":"World J Orthop","doi-asserted-by":"publisher","first-page":"695","DOI":"10.5312\/wjo.v7.i10.695","article-title":"Laminar screw fixation in the subaxial cervical spine: a report on three cases","volume":"7","author":"Tanabe H","year":"2016","unstructured":"Tanabe H, Aota Y, Saito T: Laminar screw fixation in the subaxial cervical spine: a report on three cases. World J Orthop 7:695\u2013699, 201610.5312\/wjo.v7.i10.69527795952"},{"key":"b31","series-title":"Cureus","first-page":"e2191","article-title":"Myelopathy improvement following removal of cervical sublaminar wiring","volume":"10","author":"Tullos HJ","year":"2018","unstructured":"Tullos HJ, Briggs RG, Conner AK, Williams AE, Maxwell JB, Martin MD: Myelopathy improvement following removal of cervical sublaminar wiring. Cureus 10:e2191, 201829662730"},{"key":"b32","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1227\/01.NEU.0000368106.34969.FA","article-title":"Hybrid spinal constructs using sublaminar polyester bands in posterior instrumented fusions in children: a series of 5 cases","volume":"66","author":"Viswanathan A","year":"2010","unstructured":"Viswanathan A, Johnson KK, Whitehead WE, Curry DJ, Luerssen TG, Jea A: Hybrid spinal constructs using sublaminar polyester bands in posterior instrumented fusions in children: a series of 5 cases. Neurosurgery 66:862\u2013867, 201010.1227\/01.NEU.0000368106.34969.FA20404689"},{"key":"b33","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"184","DOI":"10.3171\/2018.7.SPINE18136","article-title":"Biomechanical assessment of proximal junctional semi-rigid fixation in long-segment thoracolumbar constructs","volume":"30","author":"Viswanathan VK","year":"2019","unstructured":"Viswanathan VK, Ganguly R, Minnema AJ, DeVries Watson NA, Grosland NM, Fredericks DC, : Biomechanical assessment of proximal junctional semi-rigid fixation in long-segment thoracolumbar constructs. J Neurosurg Spine 30:184\u2013192, 201910.3171\/2018.7.SPINE18136"},{"key":"b34","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"520","DOI":"10.3171\/2017.8.SPINE17672","article-title":"Prospective assessment of the safety and early outcomes of sublaminar band placement for the prevention of proximal junctional kyphosis","volume":"28","author":"Viswanathan VK","year":"2018","unstructured":"Viswanathan VK, Kukreja S, Minnema AJ, Farhadi HF: Prospective assessment of the safety and early outcomes of sublaminar band placement for the prevention of proximal junctional kyphosis. J Neurosurg Spine 28:520\u2013531, 20182942467710.3171\/2017.8.SPINE17672"},{"key":"b35","series-title":"Surg Neurol","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1016\/0090-3019(93)90047-5","article-title":"Risks and cost-effectiveness of sublaminar wiring in posterior fusion of cervical spine trauma","volume":"40","author":"Watts C","year":"1993","unstructured":"Watts C, Smith H, Knoller N: Risks and cost-effectiveness of sublaminar wiring in posterior fusion of cervical spine trauma. Surg Neurol 40:457\u2013460, 1993823596710.1016\/0090-3019(93)90047-5"},{"key":"b36","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"614","DOI":"10.3171\/2013.8.SPINE13136","article-title":"Screw-related complications in the subaxial cervical spine with the use of lateral mass versus cervical pedicle screws: a systematic review","volume":"19","author":"Yoshihara H","year":"2013","unstructured":"Yoshihara H, Passias PG, Errico TJ: Screw-related complications in the subaxial cervical spine with the use of lateral mass versus cervical pedicle screws: a systematic review. J Neurosurg Spine 19:614\u2013623, 201310.3171\/2013.8.SPINE1313624033303"},{"key":"b37","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1007\/s00586-009-1032-7","article-title":"Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope","volume":"18","author":"Yukawa Y","year":"2009","unstructured":"Yukawa Y, Kato F, Ito K, Horie Y, Hida T, Nakashima H, : Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J 18:1293\u20131299, 20091948879410.1007\/s00586-009-1032-7"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/30\/6\/article-p772.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/30\/6\/article-p772.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/30\/6\/article-p772.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T22:33:38Z","timestamp":1681598018000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/30\/6\/article-p772.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6]]},"references-count":37,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2018.12.spine181147","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2019,6]]}}}