{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T23:03:07Z","timestamp":1790204587243,"version":"4.1.0"},"reference-count":116,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,8]]},"abstract":"<jats:p>Neuromodulation and deep brain stimulation (DBS) have been increasingly used in many neurological ailments, including essential tremor, Parkinson\u2019s disease, epilepsy, and more. Yet for many patients and practitioners the desire to utilize these therapies is met with caution, given the need for craniotomy, lead insertion through brain parenchyma, and, at many times, bilateral invasive procedures. Currently endovascular therapy is a standard of care for emergency thrombectomy, aneurysm treatment, and other vascular malformation\/occlusive disease of the cerebrum. Endovascular techniques and delivery catheters have advanced greatly in both their ability to safely reach remote brain locations and deliver devices. In this review the authors discuss minimally invasive endovascular delivery of devices and neural stimulating and recording from cortical and DBS targets via the neurovascular network.<\/jats:p>","DOI":"10.3171\/2018.4.focus18130","type":"journal-article","created":{"date-parts":[[2018,8,1]],"date-time":"2018-08-01T03:37:05Z","timestamp":1533094625000},"page":"E19","source":"Crossref","is-referenced-by-count":24,"title":["Endovascular delivery of leads and stentrodes and their applications to deep brain stimulation and neuromodulation: a review"],"prefix":"10.3171","volume":"45","author":[{"given":"Gary","family":"Rajah","sequence":"first","affiliation":[{"name":"Departments of Neurosurgery and"},{"name":"Wayne State University School of Medicine, Detroit, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hamidreza","family":"Saber","sequence":"additional","affiliation":[{"name":"Neurology, Wayne State University, and"},{"name":"Wayne State University School of Medicine, Detroit, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rasanjeet","family":"Singh","sequence":"additional","affiliation":[{"name":"Wayne State University School of Medicine, Detroit, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonardo","family":"Rangel-Castilla","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Mayo Clinic, Rochester, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Cardiology","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1159\/000007018","article-title":"Transvenous pacing lead-induced thrombosis: a series of cases with a review of the literature","volume":"93","author":"Barakat K","year":"2000","unstructured":"Barakat K, Robinson NM, Spurrell RA: Transvenous pacing lead-induced thrombosis: a series of cases with a review of the literature. Cardiology 93:142\u2013148, 200010.1159\/00000701810965084"},{"key":"b2","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1227\/01.NEU.0000156473.57196.7E","article-title":"Risk factors for hemorrhage during microelectrode-guided deep brain stimulator implantation for movement disorders","volume":"56","author":"Binder DK","year":"2005","unstructured":"Binder DK, Rau GM, Starr PA: Risk factors for hemorrhage during microelectrode-guided deep brain stimulator implantation for movement disorders. Neurosurgery 56:722\u2013732, 200510.1227\/01.NEU.0000156473.57196.7E15792511"},{"key":"b3","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1227\/01.NEU.0000290890.62201.A9","article-title":"Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up","volume":"61","author":"Biondi A","year":"2007","unstructured":"Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP: Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460\u2013469, 20071788195610.1227\/01.NEU.0000290890.62201.A9"},{"key":"b4","series-title":"US patent 8,412,350B2","doi-asserted-by":"publisher","DOI":"10.1016\/S1353-8020(13)70045-2","article-title":"Cardiac Pacemakers, Inc., assignee: Neurostimulating lead having a stent-like anchor","author":"Bly MJ","year":"April 2, 2013","unstructured":"Bly MJ, inventor; Cardiac Pacemakers, Inc., assignee: Neurostimulating lead having a stent-like anchor. US patent 8,412,350B2. April 2, 201310.1016\/S1353-8020(13)70045-2"},{"key":"b5","series-title":"J Neurosci Methods","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.jneumeth.2012.12.027","article-title":"Intravenous recording of intracranial, broadband EEG","volume":"214","author":"Bower MR","year":"2013","unstructured":"Bower MR, Stead M, Van Gompel JJ, Bower RS, Sulc V, Asirvatham SJ, : Intravenous recording of intracranial, broadband EEG. J Neurosci Methods 214:21\u201326, 20132331385010.1016\/j.jneumeth.2012.12.027"},{"key":"b6","series-title":"Micromachines","doi-asserted-by":"publisher","first-page":"135","DOI":"10.3390\/mi7080135","article-title":"An implantable intravascular pressure sensor for a ventricular assist device","volume":"7","author":"Brancato L","year":"2016","unstructured":"Brancato L, Keulemans G, Verbelen T, Meyns B, Puers R: An implantable intravascular pressure sensor for a ventricular assist device. Micromachines 7:135, 201610.3390\/mi7080135"},{"key":"b7","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1161\/STROKEAHA.112.678151","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji W","year":"2013","unstructured":"Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF: Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke 44:442\u2013447, 20132332143810.1161\/STROKEAHA.112.678151"},{"key":"b8","series-title":"US patent 6,445,953B1","article-title":"Kenergy, Inc., assignee: Wireless cardiac pacing system with vascular electrode-stents","author":"Bulkes C","unstructured":"Bulkes C, Beutler AJ, Denker S, inventors; Kenergy, Inc., assignee: Wireless cardiac pacing system with vascular electrode-stents. US patent 6,445,953B1. September 3, 2002"},{"key":"b9","series-title":"J Neurointerv Surg","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1136\/neurintsurg-2012-010612","article-title":"Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device","volume":"6","author":"Chalouhi N","year":"2014","unstructured":"Chalouhi N, Chitale R, Starke RM, Jabbour P, Tjoumakaris S, Dumont AS, : Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device. J Neurointerv Surg 6:19\u201323, 201410.1136\/neurintsurg-2012-01061223345630"},{"key":"b10","series-title":"IEEE Trans Biomed Eng","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1109\/TBME.2005.862572","article-title":"Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes","volume":"53","author":"Cogan SF","year":"2006","unstructured":"Cogan SF, Troyk PR, Ehrlich J, Plante TD, Detlefsen DE: Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes. IEEE Trans Biomed Eng 53:327\u2013332, 200610.1109\/TBME.2005.86257216485762"},{"key":"b11","series-title":"N Engl J Med","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1056\/NEJMoa060281","article-title":"A randomized trial of deep-brain stimulation for Parkinson\u2019s disease","volume":"355","author":"Deuschl G","year":"2006","unstructured":"Deuschl G, Schade-Brittinger C, Krack P, Volkmann J, Sch\u00e4fer H, B\u00f6tzel K, : A randomized trial of deep-brain stimulation for Parkinson\u2019s disease. N Engl J Med 355:896\u2013908, 200610.1056\/NEJMoa06028116943402"},{"key":"b12","series-title":"Nat Commun","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1038\/s41467-017-02753-0","article-title":"Closed-loop stimulation of temporal cortex rescues functional networks and improves memory","volume":"9","author":"Ezzyat Y","year":"2018","unstructured":"Ezzyat Y, Wanda PA, Levy DF, Kadel A, Aka A, Pedisich I, : Closed-loop stimulation of temporal cortex rescues functional networks and improves memory. Nat Commun 9:365, 20182941041410.1038\/s41467-017-02753-0"},{"key":"b13","series-title":"Neuromodulation","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1111\/ner.12335","article-title":"Long-term evaluation of changes in operative technique and hardware-related complications with deep brain stimulation","volume":"18","author":"Falowski SM","year":"2015","unstructured":"Falowski SM, Ooi YC, Bakay RA: Long-term evaluation of changes in operative technique and hardware-related complications with deep brain stimulation. Neuromodulation 18:670\u2013677, 201510.1111\/ner.1233526245633"},{"key":"b14","series-title":"Sci Transl Med","article-title":"First-in-human testing of a wirelessly controlled drug delivery microchip","volume":"4","author":"Farra R","unstructured":"Farra R, Sheppard NF, McCabe L, Neer RM, Anderson JM, Santini JT, : First-in-human testing of a wirelessly controlled drug delivery microchip. Sci Transl Med 4:122ra121, 201222344516"},{"key":"b15","series-title":"Brain Stimul","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.brs.2012.08.001","article-title":"Memory modulation by weak synchronous deep brain stimulation: a pilot study","volume":"6","author":"Fell J","year":"2013","unstructured":"Fell J, Staresina BP, Do Lam AT, Widman G, Helmstaedter C, Elger CE, : Memory modulation by weak synchronous deep brain stimulation: a pilot study. Brain Stimul 6:270\u2013273, 201310.1016\/j.brs.2012.08.00122939277"},{"key":"b16","series-title":"Catheter Cardiovasc Interv","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1002\/ccd.20692","article-title":"Very late thrombosis after drug-eluting stents","volume":"68","author":"Feres F","year":"2006","unstructured":"Feres F, Costa JR Jr, Abizaid A: Very late thrombosis after drug-eluting stents. Catheter Cardiovasc Interv 68:83\u201388, 200610.1002\/ccd.2069216763989"},{"key":"b17","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1161\/01.STR.0000257963.65728.e8","article-title":"US multicenter experience with the wingspan stent system for the treatment of intracranial atheromatous disease: periprocedural results","volume":"38","author":"Fiorella D","year":"2007","unstructured":"Fiorella D, Levy EI, Turk AS, Albuquerque FC, Niemann DB, Aagaard-Kienitz B, : US multicenter experience with the wingspan stent system for the treatment of intracranial atheromatous disease: periprocedural results. Stroke 38:881\u2013887, 200710.1161\/01.STR.0000257963.65728.e817290030"},{"key":"b18","series-title":"Neurol Res","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1179\/1743132811Y.0000000012","article-title":"Complications and adverse events associated with Neuroform stent-assisted coiling of wide-neck intracranial aneurysms","volume":"33","author":"Gao X","year":"2011","unstructured":"Gao X, Liang G, Li Z, Wei X, Hong Q: Complications and adverse events associated with Neuroform stent-assisted coiling of wide-neck intracranial aneurysms. Neurol Res 33:841\u2013852, 20112200470810.1179\/1743132811Y.0000000012"},{"key":"b19","series-title":"Neuropsychopharmacology","doi-asserted-by":"publisher","first-page":"2384","DOI":"10.1038\/sj.npp.1301165","article-title":"Three-year outcomes in deep brain stimulation for highly resistant obsessive-compulsive disorder","volume":"31","author":"Greenberg BD","year":"2006","unstructured":"Greenberg BD, Malone DA, Friehs GM, Rezai AR, Kubu CS, Malloy PF, : Three-year outcomes in deep brain stimulation for highly resistant obsessive-compulsive disorder. Neuropsychopharmacology 31:2384\u20132393, 200610.1038\/sj.npp.130116516855529"},{"issue":"Suppl 1","key":"b20","series-title":"Parkinsonism Relat Disord","first-page":"S192","article-title":"Deep brain stimulation: new techniques","volume":"20","author":"Hariz M","year":"2014","unstructured":"Hariz M: Deep brain stimulation: new techniques. Parkinsonism Relat Disord 20 (Suppl 1):S192\u2013S196, 2014"},{"key":"b21","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1111\/epi.12534","article-title":"Two-year seizure reduction in adults with medically intractable partial onset epilepsy treated with responsive neurostimulation: final results of the RNS System Pivotal trial","volume":"55","author":"Heck CN","year":"2014","unstructured":"Heck CN, King-Stephens D, Massey AD, Nair DR, Jobst BC, Barkley GL, : Two-year seizure reduction in adults with medically intractable partial onset epilepsy treated with responsive neurostimulation: final results of the RNS System Pivotal trial. Epilepsia 55:432\u2013441, 201410.1111\/epi.1253424621228"},{"key":"b22","series-title":"US patent","article-title":"The University of Iowa Research Foundation, assignee: Wireless prosthetic electrode for the brain","author":"Howard MA III","unstructured":"Howard MA III, inventor; The University of Iowa Research Foundation, assignee: Wireless prosthetic electrode for the brain. US patent 5,800,535. September 1, 1998"},{"key":"b23","series-title":"Neurology","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1212\/WNL.46.4.1150","article-title":"Deep brain stimulation for essential tremor","volume":"46","author":"Hubble JP","year":"1996","unstructured":"Hubble JP, Busenbark KL, Wilkinson S, Penn RD, Lyons K, Koller WC: Deep brain stimulation for essential tremor. Neurology 46:1150\u20131153, 1996878010910.1212\/WNL.46.4.1150"},{"key":"b24","series-title":"J Neurointerv Surg","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1136\/neurintsurg-2017-013375","article-title":"Safety and effectiveness of the Low Profile Visualized Intraluminal Support (LVIS and LVIS Jr) devices in the endovascular treatment of intracranial aneurysms: results of the TRAIL multicenter observational study","volume":"10","author":"Iosif C","year":"2018","unstructured":"Iosif C, Piotin M, Saleme S, Barreau X, Sedat J, Chau Y, : Safety and effectiveness of the Low Profile Visualized Intraluminal Support (LVIS and LVIS Jr) devices in the endovascular treatment of intracranial aneurysms: results of the TRAIL multicenter observational study. J Neurointerv Surg 10:675\u2013681, 20182917582910.1136\/neurintsurg-2017-013375"},{"issue":"Suppl 5","key":"b25","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1111\/j.1528-1157.1998.tb01965.x","article-title":"Intracranial EEG recording from intravascular electrodes in patients with temporal lobe epilepsy","volume":"39","author":"Ishida S","year":"1998","unstructured":"Ishida S, Shimamoto H, Abe T, Motooka H, Sakurai S, Takayama K, : Intracranial EEG recording from intravascular electrodes in patients with temporal lobe epilepsy. Epilepsia 39 (Suppl 5):77, 1998 (Abstract)10.1111\/j.1528-1157.1998.tb01965.x"},{"key":"b26","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"111","DOI":"10.3171\/JNS\/2008\/108\/01\/0111","article-title":"Gamma Knife thalamotomy for essential tremor","volume":"108","author":"Kondziolka D","year":"2008","unstructured":"Kondziolka D, Ong JG, Lee JY, Moore RY, Flickinger JC, Lunsford LD: Gamma Knife thalamotomy for essential tremor. J Neurosurg 108:111\u2013117, 2008 (Erratum in J Neurosurg 108:635, 2008)10.3171\/JNS\/2008\/108\/01\/011118173319"},{"key":"b27","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1111\/j.1528-1157.2000.tb00116.x","article-title":"Use of cavernous sinus EEG in the detection of seizure onset and spread in mesial temporal lobe epilepsy","volume":"41","author":"Kunieda T","year":"2000","unstructured":"Kunieda T, Ikeda A, Mikuni N, Ohara S, Sadato A, Taki W, : Use of cavernous sinus EEG in the detection of seizure onset and spread in mesial temporal lobe epilepsy. Epilepsia 41:1411\u20131419, 20001107745410.1111\/j.1528-1157.2000.tb00116.x"},{"key":"b28","series-title":"IEEE J Solid State Circuits","doi-asserted-by":"publisher","first-page":"2203","DOI":"10.1109\/JSSC.2013.2266862","article-title":"A power-efficient wireless system with adaptive supply control for deep brain stimulation","volume":"48","author":"Lee HM","year":"2013","unstructured":"Lee HM, Park H, Ghovanloo M: A power-efficient wireless system with adaptive supply control for deep brain stimulation. IEEE J Solid State Circuits 48:2203\u20132216, 20132467812610.1109\/JSSC.2013.2266862"},{"key":"b29","series-title":"J Am Coll Cardiol","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1016\/j.jacc.2007.04.081","article-title":"First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices","volume":"50","author":"Lee KL","year":"2007","unstructured":"Lee KL, Lau CP, Tse HF, Echt DS, Heaven D, Smith W, : First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices. J Am Coll Cardiol 50:877\u2013883, 20071771947510.1016\/j.jacc.2007.04.081"},{"key":"b30","series-title":"Lancet Neurol","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1016\/S1474-4422(13)70048-6","article-title":"MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study","volume":"12","author":"Lipsman N","year":"2013","unstructured":"Lipsman N, Schwartz ML, Huang Y, Lee L, Sankar T, Chapman M, : MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study. Lancet Neurol 12:462\u2013468, 201310.1016\/S1474-4422(13)70048-623523144"},{"key":"b31","series-title":"Ann Neurol","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1002\/ana.23951","article-title":"Adaptive deep brain stimulation in advanced Parkinson disease","volume":"74","author":"Little S","year":"2013","unstructured":"Little S, Pogosyan A, Neal S, Zavala B, Zrinzo L, Hariz M, : Adaptive deep brain stimulation in advanced Parkinson disease. Ann Neurol 74:449\u2013457, 201310.1002\/ana.2395123852650"},{"key":"b32","series-title":"J Nanopart Res","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/s11051-005-3134-4","article-title":"Neuro-vascular central nervous recording\/stimulating system: using nanotechnology probes","volume":"7","author":"Llin\u00e1s RR","year":"2005","unstructured":"Llin\u00e1s RR, Walton KD, Nakao M, Hunter I, Anquetil PA: Neuro-vascular central nervous recording\/stimulating system: using nanotechnology probes. J Nanopart Res 7:111\u2013127, 200510.1007\/s11051-005-3134-4"},{"key":"b33","series-title":"Mayo Clin Proc","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.mayocp.2014.02.003","article-title":"Brain machine interface and limb reanimation technologies: restoring function after spinal cord injury through development of a bypass system","volume":"89","author":"Lobel DA","year":"2014","unstructured":"Lobel DA, Lee KH: Brain machine interface and limb reanimation technologies: restoring function after spinal cord injury through development of a bypass system. Mayo Clin Proc 89:708\u2013714, 20142479764910.1016\/j.mayocp.2014.02.003"},{"key":"b34","series-title":"Neuron","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1016\/j.neuron.2005.02.014","article-title":"Deep brain stimulation for treatment-resistant depression","volume":"45","author":"Mayberg HS","year":"2005","unstructured":"Mayberg HS, Lozano AM, Voon V, McNeely HE, Seminowicz D, Hamani C, : Deep brain stimulation for treatment-resistant depression. Neuron 45:651\u2013660, 20051574884110.1016\/j.neuron.2005.02.014"},{"key":"b35","series-title":"Brain","doi-asserted-by":"publisher","first-page":"1833","DOI":"10.1093\/brain\/awv095","article-title":"Visual-spatial memory may be enhanced with theta burst deep brain stimulation of the fornix: a preliminary investigation with four cases","volume":"138","author":"Miller JP","year":"2015","unstructured":"Miller JP, Sweet JA, Bailey CM, Munyon CN, Luders HO, Fastenau PS: Visual-spatial memory may be enhanced with theta burst deep brain stimulation of the fornix: a preliminary investigation with four cases. Brain 138:1833\u20131842, 201510.1093\/brain\/awv09526106097"},{"key":"b36","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"414","DOI":"10.3171\/2016.9.JNS16452","article-title":"Alternating electric tumor treating fields for treatment of glioblastoma: rationale, preclinical, and clinical studies","volume":"128","author":"Mittal S","year":"2018","unstructured":"Mittal S, Klinger NV, Michelhaugh SK, Barger GR, Pannullo SC, Juh\u00e1sz C: Alternating electric tumor treating fields for treatment of glioblastoma: rationale, preclinical, and clinical studies. J Neurosurg 128:414\u2013421, 20182829802310.3171\/2016.9.JNS16452"},{"key":"b37","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.3171\/2010.2.JNS091528","article-title":"Simulation and assessment of cerebrovascular damage in deep brain stimulation using a stereotactic atlas of vasculature and structure derived from multiple 3- and 7-tesla scans","volume":"113","author":"Nowinski WL","year":"2010","unstructured":"Nowinski WL, Chua BC, Volkau I, Puspitasari F, Marchenko Y, Runge VM, : Simulation and assessment of cerebrovascular damage in deep brain stimulation using a stereotactic atlas of vasculature and structure derived from multiple 3- and 7-tesla scans. J Neurosurg 113:1234\u20131241, 20102034522610.3171\/2010.2.JNS091528"},{"key":"b38","series-title":"Piscataway, NJ: IEEE","first-page":"3476","article-title":"RFID STENTag for passive vascular monitoring, in Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP)","author":"Occhiuzzi C","year":"2011","unstructured":"Occhiuzzi C, Contri G, Marrocco G: RFID STENTag for passive vascular monitoring, in Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP). Piscataway, NJ: IEEE, 2011, pp 3476\u20133478 (https:\/\/ieeexplore.ieee.org\/document\/5782311\/) [Accessed June 14, 2018]"},{"key":"b39","series-title":"Neurosurgery","first-page":"1268","article-title":"Long-term hardware-related complications of deep brain stimulation","volume":"50","author":"Oh MY","year":"2002","unstructured":"Oh MY, Abosch A, Kim SH, Lang AE, Lozano AM: Long-term hardware-related complications of deep brain stimulation. Neurosurgery 50:1268\u20131276, 200212015845"},{"key":"b40","series-title":"IEEE Trans Biomed Eng","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1109\/TBME.2016.2552226","article-title":"Micro-CT and histological evaluation of an neural interface implanted within a blood vessel","volume":"64","author":"Opie NL","year":"2017","unstructured":"Opie NL, van der Nagel NR, John SE, Vessey K, Rind GS, Ronayne SM, : Micro-CT and histological evaluation of an neural interface implanted within a blood vessel. IEEE Trans Biomed Eng 64:928\u2013934, 201710.1109\/TBME.2016.255222627337706"},{"key":"b41","series-title":"Interv Neuroradiol","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1177\/1591019917753824","article-title":"Experience using pipeline embolization device with Shield Technology in a patient lacking a full postoperative dual antiplatelet therapy regimen","volume":"24","author":"Orlov K","year":"2018","unstructured":"Orlov K, Kislitsin D, Strelnikov N, Berestov V, Gorbatykh A, Shayakhmetov T, : Experience using pipeline embolization device with Shield Technology in a patient lacking a full postoperative dual antiplatelet therapy regimen. Interv Neuroradiol 24:270\u2013273, 201810.1177\/1591019917753824"},{"key":"b42","series-title":"Nat Biotechnol","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1038\/nbt.3428","article-title":"Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity","volume":"34","author":"Oxley TJ","year":"2016","unstructured":"Oxley TJ, Opie NL, John SE, Rind GS, Ronayne SM, Wheeler TL, : Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity. Nat Biotechnol 34:320\u2013327, 20162685447610.1038\/nbt.3428"},{"key":"b43","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"239","DOI":"10.3171\/jns.1973.38.2.0239","article-title":"Intravascular intracranial EEG recording. Technical note","volume":"38","author":"Penn RD","year":"1973","unstructured":"Penn RD, Hilal SK, Michelsen WJ, Goldensohn ES, Driller J: Intravascular intracranial EEG recording. Technical note. J Neurosurg 38:239\u2013243, 1973463283110.3171\/jns.1973.38.2.0239"},{"issue":"Suppl 3","key":"b44","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1227\/NEU.0000000000000864","article-title":"Feasibility, safety, and periprocedural complications of pipeline embolization for intracranial aneurysm treatment under conscious sedation: University at Buffalo Neurosurgery Experience","volume":"11","author":"Rangel-Castilla L","year":"2015","unstructured":"Rangel-Castilla L, Cress MC, Munich SA, Sonig A, Krishna C, Gu EY, : Feasibility, safety, and periprocedural complications of pipeline embolization for intracranial aneurysm treatment under conscious sedation: University at Buffalo Neurosurgery Experience. Neurosurgery 11 (Suppl 3):426\u2013430, 20152628435110.1227\/NEU.0000000000000864"},{"issue":"5","key":"b45","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2016.3.FOCUS15635","article-title":"The evolution of endovascular electroencephalography: historical perspective and future applications","volume":"40","author":"Sefcik RK","year":"2016","unstructured":"Sefcik RK, Opie NL, John SE, Kellner CP, Mocco J, Oxley TJ: The evolution of endovascular electroencephalography: historical perspective and future applications. Neurosurg Focus 40(5):E7, 20162713252810.3171\/2016.3.FOCUS15635"},{"key":"b46","series-title":"AJNR Am J Neuroradiol","first-page":"1214","article-title":"Intracranial electroencephalographic and evoked-potential recording from intravascular guide wires","volume":"16","author":"Stoeter P","year":"1995","unstructured":"Stoeter P, Dieterle L, Meyer A, Prey N: Intracranial electroencephalographic and evoked-potential recording from intravascular guide wires. AJNR Am J Neuroradiol 16:1214\u20131217, 19957677012"},{"key":"b47","series-title":"Piscataway NJ: IEEE","first-page":"1242","article-title":"Wirelessly powered implantable pacemaker with on-chip antenna, in 2017 IEEE MTT-S International Microwave Symposium (IMS)","author":"Sun Y","year":"2017","unstructured":"Sun Y, Greet B, Burkland D, John M, Razavi M, Babakhani A: Wirelessly powered implantable pacemaker with on-chip antenna, in 2017 IEEE MTT-S International Microwave Symposium (IMS). Piscataway NJ: IEEE, 2017, pp 1242\u20131244 (https:\/\/ieeexplore.ieee.org\/document\/8058831\/) [Accessed June 14, 2018]"},{"key":"b48","series-title":"N Engl J Med","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1056\/NEJMoa1107212","article-title":"Memory enhancement and deep-brain stimulation of the entorhinal area","volume":"366","author":"Suthana N","year":"2012","unstructured":"Suthana N, Haneef Z, Stern J, Mukamel R, Behnke E, Knowlton B, : Memory enhancement and deep-brain stimulation of the entorhinal area. N Engl J Med 366:502\u2013510, 20122231644410.1056\/NEJMoa1107212"},{"key":"b49","series-title":"J Neural Eng","doi-asserted-by":"publisher","first-page":"026011","DOI":"10.1088\/1741-2560\/11\/2\/026011","article-title":"Computational modeling of an endovascular approach to deep brain stimulation","volume":"11","author":"Teplitzky BA","year":"2014","unstructured":"Teplitzky BA, Connolly AT, Bajwa JA, Johnson MD: Computational modeling of an endovascular approach to deep brain stimulation. J Neural Eng 11:026011, 201410.1088\/1741-2560\/11\/2\/02601124608363"},{"key":"b50","series-title":"Ann Thorac Surg","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/S0003-4975(97)01351-9","article-title":"Bradycardia induced by intravascular versus direct stimulation of the vagus nerve","volume":"65","author":"Thompson GW","year":"1998","unstructured":"Thompson GW, Levett JM, Miller SM, Hill MR, Meffert WG, Kolata RJ, : Bradycardia induced by intravascular versus direct stimulation of the vagus nerve. Ann Thorac Surg 65:637\u2013642, 199810.1016\/S0003-4975(97)01351-99527187"},{"key":"b51","series-title":"eLife","doi-asserted-by":"publisher","first-page":"6","DOI":"10.7554\/eLife.29515","article-title":"Theta-burst microstimulation in the human entorhinal area improves memory specificity","volume":"6","author":"Titiz AS","year":"2017","unstructured":"Titiz AS, Hill MRH, Mankin EA, M Aghajan Z, Eliashiv D, Tchemodanov N, : Theta-burst microstimulation in the human entorhinal area improves memory specificity. eLife 6:6, 201710.7554\/eLife.29515"},{"key":"b52","series-title":"US patent application 2005\/0137646A1","article-title":"Scimed Life Systems, Inc., assignee: Method of intravascularly delivering stimulation leads into brain","author":"Wallace MP","unstructured":"Wallace MP, Garabedian RJ, Abrams RM, inventors; Scimed Life Systems, Inc., assignee: Method of intravascularly delivering stimulation leads into brain. US patent application 2005\/0137646A1. June 23, 2005"},{"key":"b53","series-title":"US patent 7,818,063B2","article-title":"Method of intravascularly delivering stimulation leads into brain to stimulate the SPG","author":"Wallace MP","unstructured":"Wallace MP, Garabedian RJ, Abrams RM, inventors; Boston Scientific Scimed, Inc., assignee: Method of intravascularly delivering stimulation leads into brain to stimulate the SPG. US patent 7,818,063B2. October 19, 2010"},{"key":"b54","series-title":"Electron Commun Jpn","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1002\/ecj.10058","article-title":"Intravascular neural interface with nanowire electrode","volume":"92","author":"Watanabe H","year":"2009","unstructured":"Watanabe H, Takahashi H, Nakao M, Walton K, Llin\u00e1s RR: Intravascular neural interface with nanowire electrode. Electron Commun Jpn 92:29\u201337, 20092157294010.1002\/ecj.10058"},{"key":"b55","series-title":"Neurosurgery","first-page":"N22","article-title":"Endovascular access for cortical mapping","volume":"79","author":"Weiner GM","year":"2016","unstructured":"Weiner GM, Ozpinar A, Ducruet A: Endovascular access for cortical mapping. Neurosurgery 79:N22\u2013N23, 2016"},{"key":"b56","series-title":"Conf Proc IEEE Eng Med Biol Soc","first-page":"2016","article-title":"Suitability of nitinol electrodes in neural prostheses such as endovascular neural interfaces","volume":"4463\u20134466","author":"Wong YT","year":"2016","unstructured":"Wong YT, Opie NL, John SE, Gerboni G, Rind GS, Ronayne SM, : Suitability of nitinol electrodes in neural prostheses such as endovascular neural interfaces. Conf Proc IEEE Eng Med Biol Soc 2016:4463\u20134466, 2016"},{"key":"b57","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1715","DOI":"10.3171\/2011.1.JNS101421","article-title":"Real-time control of a prosthetic hand using human electrocorticography signals","volume":"114","author":"Yanagisawa T","year":"2011","unstructured":"Yanagisawa T, Hirata M, Saitoh Y, Goto T, Kishima H, Fukuma R, : Real-time control of a prosthetic hand using human electrocorticography signals. J Neurosurg 114:1715\u20131722, 201110.3171\/2011.1.JNS10142121314273"},{"key":"b58","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.3171\/2009.10.JNS09332","article-title":"Gamma Knife thalamotomy for treatment of essential tremor: long-term results","volume":"112","author":"Young RF","year":"2010","unstructured":"Young RF, Li F, Vermeulen S, Meier R: Gamma Knife thalamotomy for treatment of essential tremor: long-term results. J Neurosurg 112:1311\u20131317, 201010.3171\/2009.10.JNS0933219895197"},{"key":"b1","series-title":"Cardiology","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1159\/000007018","article-title":"Transvenous pacing lead-induced thrombosis: a series of cases with a review of the literature","volume":"93","author":"Barakat K","year":"2000","unstructured":"Barakat K, Robinson NM, Spurrell RA: Transvenous pacing lead-induced thrombosis: a series of cases with a review of the literature. Cardiology 93:142\u2013148, 200010.1159\/00000701810965084"},{"key":"b2","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1227\/01.NEU.0000156473.57196.7E","article-title":"Risk factors for hemorrhage during microelectrode-guided deep brain stimulator implantation for movement disorders","volume":"56","author":"Binder DK","year":"2005","unstructured":"Binder DK, Rau GM, Starr PA: Risk factors for hemorrhage during microelectrode-guided deep brain stimulator implantation for movement disorders. Neurosurgery 56:722\u2013732, 200510.1227\/01.NEU.0000156473.57196.7E15792511"},{"key":"b3","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1227\/01.NEU.0000290890.62201.A9","article-title":"Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up","volume":"61","author":"Biondi A","year":"2007","unstructured":"Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP: Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460\u2013469, 20071788195610.1227\/01.NEU.0000290890.62201.A9"},{"key":"b4","series-title":"US patent 8,412,350B2","article-title":"Cardiac Pacemakers, Inc., assignee: Neurostimulating lead having a stent-like anchor","author":"Bly MJ","year":"April 2, 2013","unstructured":"Bly MJ, inventor; Cardiac Pacemakers, Inc., assignee: Neurostimulating lead having a stent-like anchor. US patent 8,412,350B2. April 2, 2013"},{"key":"b5","series-title":"J Neurosci Methods","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.jneumeth.2012.12.027","article-title":"Intravenous recording of intracranial, broadband EEG","volume":"214","author":"Bower MR","year":"2013","unstructured":"Bower MR, Stead M, Van Gompel JJ, Bower RS, Sulc V, Asirvatham SJ, : Intravenous recording of intracranial, broadband EEG. J Neurosci Methods 214:21\u201326, 20132331385010.1016\/j.jneumeth.2012.12.027"},{"key":"b6","series-title":"Micromachines","doi-asserted-by":"publisher","first-page":"135","DOI":"10.3390\/mi7080135","article-title":"An implantable intravascular pressure sensor for a ventricular assist device","volume":"7","author":"Brancato L","year":"2016","unstructured":"Brancato L, Keulemans G, Verbelen T, Meyns B, Puers R: An implantable intravascular pressure sensor for a ventricular assist device. Micromachines 7:135, 201610.3390\/mi7080135"},{"key":"b7","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1161\/STROKEAHA.112.678151","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji W","year":"2013","unstructured":"Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF: Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke 44:442\u2013447, 20132332143810.1161\/STROKEAHA.112.678151"},{"key":"b8","series-title":"US patent 6,445,953B1","article-title":"Kenergy, Inc., assignee: Wireless cardiac pacing system with vascular electrode-stents","author":"Bulkes C","unstructured":"Bulkes C, Beutler AJ, Denker S, inventors; Kenergy, Inc., assignee: Wireless cardiac pacing system with vascular electrode-stents. US patent 6,445,953B1. September 3, 2002"},{"key":"b9","series-title":"J Neurointerv Surg","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1136\/neurintsurg-2012-010612","article-title":"Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device","volume":"6","author":"Chalouhi N","year":"2014","unstructured":"Chalouhi N, Chitale R, Starke RM, Jabbour P, Tjoumakaris S, Dumont AS, : Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device. J Neurointerv Surg 6:19\u201323, 201410.1136\/neurintsurg-2012-01061223345630"},{"key":"b10","series-title":"IEEE Trans Biomed Eng","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1109\/TBME.2005.862572","article-title":"Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes","volume":"53","author":"Cogan SF","year":"2006","unstructured":"Cogan SF, Troyk PR, Ehrlich J, Plante TD, Detlefsen DE: Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes. IEEE Trans Biomed Eng 53:327\u2013332, 200610.1109\/TBME.2005.86257216485762"},{"key":"b11","series-title":"N Engl J Med","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1056\/NEJMoa060281","article-title":"A randomized trial of deep-brain stimulation for Parkinson\u2019s disease","volume":"355","author":"Deuschl G","year":"2006","unstructured":"Deuschl G, Schade-Brittinger C, Krack P, Volkmann J, Sch\u00e4fer H, B\u00f6tzel K, : A randomized trial of deep-brain stimulation for Parkinson\u2019s disease. N Engl J Med 355:896\u2013908, 200610.1056\/NEJMoa06028116943402"},{"key":"b12","series-title":"Nat Commun","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1038\/s41467-017-02753-0","article-title":"Closed-loop stimulation of temporal cortex rescues functional networks and improves memory","volume":"9","author":"Ezzyat Y","year":"2018","unstructured":"Ezzyat Y, Wanda PA, Levy DF, Kadel A, Aka A, Pedisich I, : Closed-loop stimulation of temporal cortex rescues functional networks and improves memory. Nat Commun 9:365, 20182941041410.1038\/s41467-017-02753-0"},{"key":"b13","series-title":"Neuromodulation","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1111\/ner.12335","article-title":"Long-term evaluation of changes in operative technique and hardware-related complications with deep brain stimulation","volume":"18","author":"Falowski SM","year":"2015","unstructured":"Falowski SM, Ooi YC, Bakay RA: Long-term evaluation of changes in operative technique and hardware-related complications with deep brain stimulation. Neuromodulation 18:670\u2013677, 201510.1111\/ner.1233526245633"},{"key":"b14","series-title":"Sci Transl Med","article-title":"First-in-human testing of a wirelessly controlled drug delivery microchip","volume":"4","author":"Farra R","unstructured":"Farra R, Sheppard NF, McCabe L, Neer RM, Anderson JM, Santini JT, : First-in-human testing of a wirelessly controlled drug delivery microchip. Sci Transl Med 4:122ra121, 201222344516"},{"key":"b15","series-title":"Brain Stimul","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.brs.2012.08.001","article-title":"Memory modulation by weak synchronous deep brain stimulation: a pilot study","volume":"6","author":"Fell J","year":"2013","unstructured":"Fell J, Staresina BP, Do Lam AT, Widman G, Helmstaedter C, Elger CE, : Memory modulation by weak synchronous deep brain stimulation: a pilot study. Brain Stimul 6:270\u2013273, 201310.1016\/j.brs.2012.08.00122939277"},{"key":"b16","series-title":"Catheter Cardiovasc Interv","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1002\/ccd.20692","article-title":"Very late thrombosis after drug-eluting stents","volume":"68","author":"Feres F","year":"2006","unstructured":"Feres F, Costa JR Jr, Abizaid A: Very late thrombosis after drug-eluting stents. Catheter Cardiovasc Interv 68:83\u201388, 200610.1002\/ccd.2069216763989"},{"key":"b17","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1161\/01.STR.0000257963.65728.e8","article-title":"US multicenter experience with the wingspan stent system for the treatment of intracranial atheromatous disease: periprocedural results","volume":"38","author":"Fiorella D","year":"2007","unstructured":"Fiorella D, Levy EI, Turk AS, Albuquerque FC, Niemann DB, Aagaard-Kienitz B, : US multicenter experience with the wingspan stent system for the treatment of intracranial atheromatous disease: periprocedural results. Stroke 38:881\u2013887, 200710.1161\/01.STR.0000257963.65728.e817290030"},{"key":"b18","series-title":"Neurol Res","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1179\/1743132811Y.0000000012","article-title":"Complications and adverse events associated with Neuroform stent-assisted coiling of wide-neck intracranial aneurysms","volume":"33","author":"Gao X","year":"2011","unstructured":"Gao X, Liang G, Li Z, Wei X, Hong Q: Complications and adverse events associated with Neuroform stent-assisted coiling of wide-neck intracranial aneurysms. Neurol Res 33:841\u2013852, 20112200470810.1179\/1743132811Y.0000000012"},{"key":"b19","series-title":"Neuropsychopharmacology","doi-asserted-by":"publisher","first-page":"2384","DOI":"10.1038\/sj.npp.1301165","article-title":"Three-year outcomes in deep brain stimulation for highly resistant obsessive-compulsive disorder","volume":"31","author":"Greenberg BD","year":"2006","unstructured":"Greenberg BD, Malone DA, Friehs GM, Rezai AR, Kubu CS, Malloy PF, : Three-year outcomes in deep brain stimulation for highly resistant obsessive-compulsive disorder. Neuropsychopharmacology 31:2384\u20132393, 200610.1038\/sj.npp.130116516855529"},{"issue":"Suppl 1","key":"b20","series-title":"Parkinsonism Relat Disord","first-page":"S192","article-title":"Deep brain stimulation: new techniques","volume":"20","author":"Hariz M","year":"2014","unstructured":"Hariz M: Deep brain stimulation: new techniques. Parkinsonism Relat Disord 20 (Suppl 1):S192\u2013S196, 2014"},{"key":"b21","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1111\/epi.12534","article-title":"Two-year seizure reduction in adults with medically intractable partial onset epilepsy treated with responsive neurostimulation: final results of the RNS System Pivotal trial","volume":"55","author":"Heck CN","year":"2014","unstructured":"Heck CN, King-Stephens D, Massey AD, Nair DR, Jobst BC, Barkley GL, : Two-year seizure reduction in adults with medically intractable partial onset epilepsy treated with responsive neurostimulation: final results of the RNS System Pivotal trial. Epilepsia 55:432\u2013441, 201410.1111\/epi.1253424621228"},{"key":"b22","series-title":"US patent","article-title":"The University of Iowa Research Foundation, assignee: Wireless prosthetic electrode for the brain","author":"Howard MA III","unstructured":"Howard MA III, inventor; The University of Iowa Research Foundation, assignee: Wireless prosthetic electrode for the brain. US patent 5,800,535. September 1, 1998"},{"key":"b23","series-title":"Neurology","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1212\/WNL.46.4.1150","article-title":"Deep brain stimulation for essential tremor","volume":"46","author":"Hubble JP","year":"1996","unstructured":"Hubble JP, Busenbark KL, Wilkinson S, Penn RD, Lyons K, Koller WC: Deep brain stimulation for essential tremor. Neurology 46:1150\u20131153, 1996878010910.1212\/WNL.46.4.1150"},{"key":"b24","series-title":"J Neurointerv Surg","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1136\/neurintsurg-2017-013375","article-title":"Safety and effectiveness of the Low Profile Visualized Intraluminal Support (LVIS and LVIS Jr) devices in the endovascular treatment of intracranial aneurysms: results of the TRAIL multicenter observational study","volume":"10","author":"Iosif C","year":"2018","unstructured":"Iosif C, Piotin M, Saleme S, Barreau X, Sedat J, Chau Y, : Safety and effectiveness of the Low Profile Visualized Intraluminal Support (LVIS and LVIS Jr) devices in the endovascular treatment of intracranial aneurysms: results of the TRAIL multicenter observational study. J Neurointerv Surg 10:675\u2013681, 20182917582910.1136\/neurintsurg-2017-013375"},{"issue":"Suppl 5","key":"b25","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1111\/j.1528-1157.1998.tb01965.x","article-title":"Intracranial EEG recording from intravascular electrodes in patients with temporal lobe epilepsy","volume":"39","author":"Ishida S","year":"1998","unstructured":"Ishida S, Shimamoto H, Abe T, Motooka H, Sakurai S, Takayama K, : Intracranial EEG recording from intravascular electrodes in patients with temporal lobe epilepsy. Epilepsia 39 (Suppl 5):77, 1998 (Abstract)10.1111\/j.1528-1157.1998.tb01965.x"},{"key":"b26","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"111","DOI":"10.3171\/JNS\/2008\/108\/01\/0111","article-title":"Gamma Knife thalamotomy for essential tremor","volume":"108","author":"Kondziolka D","year":"2008","unstructured":"Kondziolka D, Ong JG, Lee JY, Moore RY, Flickinger JC, Lunsford LD: Gamma Knife thalamotomy for essential tremor. J Neurosurg 108:111\u2013117, 2008 (Erratum in J Neurosurg 108:635, 2008)10.3171\/JNS\/2008\/108\/01\/011118173319"},{"key":"b27","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1111\/j.1528-1157.2000.tb00116.x","article-title":"Use of cavernous sinus EEG in the detection of seizure onset and spread in mesial temporal lobe epilepsy","volume":"41","author":"Kunieda T","year":"2000","unstructured":"Kunieda T, Ikeda A, Mikuni N, Ohara S, Sadato A, Taki W, : Use of cavernous sinus EEG in the detection of seizure onset and spread in mesial temporal lobe epilepsy. Epilepsia 41:1411\u20131419, 20001107745410.1111\/j.1528-1157.2000.tb00116.x"},{"key":"b28","series-title":"IEEE J Solid State Circuits","doi-asserted-by":"publisher","first-page":"2203","DOI":"10.1109\/JSSC.2013.2266862","article-title":"A power-efficient wireless system with adaptive supply control for deep brain stimulation","volume":"48","author":"Lee HM","year":"2013","unstructured":"Lee HM, Park H, Ghovanloo M: A power-efficient wireless system with adaptive supply control for deep brain stimulation. IEEE J Solid State Circuits 48:2203\u20132216, 20132467812610.1109\/JSSC.2013.2266862"},{"key":"b29","series-title":"J Am Coll Cardiol","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1016\/j.jacc.2007.04.081","article-title":"First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices","volume":"50","author":"Lee KL","year":"2007","unstructured":"Lee KL, Lau CP, Tse HF, Echt DS, Heaven D, Smith W, : First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices. J Am Coll Cardiol 50:877\u2013883, 20071771947510.1016\/j.jacc.2007.04.081"},{"key":"b30","series-title":"Lancet Neurol","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1016\/S1474-4422(13)70048-6","article-title":"MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study","volume":"12","author":"Lipsman N","year":"2013","unstructured":"Lipsman N, Schwartz ML, Huang Y, Lee L, Sankar T, Chapman M, : MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study. Lancet Neurol 12:462\u2013468, 201310.1016\/S1474-4422(13)70048-623523144"},{"key":"b31","series-title":"Ann Neurol","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1002\/ana.23951","article-title":"Adaptive deep brain stimulation in advanced Parkinson disease","volume":"74","author":"Little S","year":"2013","unstructured":"Little S, Pogosyan A, Neal S, Zavala B, Zrinzo L, Hariz M, : Adaptive deep brain stimulation in advanced Parkinson disease. Ann Neurol 74:449\u2013457, 201310.1002\/ana.2395123852650"},{"key":"b32","series-title":"J Nanopart Res","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/s11051-005-3134-4","article-title":"Neuro-vascular central nervous recording\/stimulating system: using nanotechnology probes","volume":"7","author":"Llin\u00e1s RR","year":"2005","unstructured":"Llin\u00e1s RR, Walton KD, Nakao M, Hunter I, Anquetil PA: Neuro-vascular central nervous recording\/stimulating system: using nanotechnology probes. J Nanopart Res 7:111\u2013127, 200510.1007\/s11051-005-3134-4"},{"key":"b33","series-title":"Mayo Clin Proc","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.mayocp.2014.02.003","article-title":"Brain machine interface and limb reanimation technologies: restoring function after spinal cord injury through development of a bypass system","volume":"89","author":"Lobel DA","year":"2014","unstructured":"Lobel DA, Lee KH: Brain machine interface and limb reanimation technologies: restoring function after spinal cord injury through development of a bypass system. Mayo Clin Proc 89:708\u2013714, 20142479764910.1016\/j.mayocp.2014.02.003"},{"key":"b34","series-title":"Neuron","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1016\/j.neuron.2005.02.014","article-title":"Deep brain stimulation for treatment-resistant depression","volume":"45","author":"Mayberg HS","year":"2005","unstructured":"Mayberg HS, Lozano AM, Voon V, McNeely HE, Seminowicz D, Hamani C, : Deep brain stimulation for treatment-resistant depression. Neuron 45:651\u2013660, 20051574884110.1016\/j.neuron.2005.02.014"},{"key":"b35","series-title":"Brain","doi-asserted-by":"publisher","first-page":"1833","DOI":"10.1093\/brain\/awv095","article-title":"Visual-spatial memory may be enhanced with theta burst deep brain stimulation of the fornix: a preliminary investigation with four cases","volume":"138","author":"Miller JP","year":"2015","unstructured":"Miller JP, Sweet JA, Bailey CM, Munyon CN, Luders HO, Fastenau PS: Visual-spatial memory may be enhanced with theta burst deep brain stimulation of the fornix: a preliminary investigation with four cases. Brain 138:1833\u20131842, 201510.1093\/brain\/awv09526106097"},{"key":"b36","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"414","DOI":"10.3171\/2016.9.JNS16452","article-title":"Alternating electric tumor treating fields for treatment of glioblastoma: rationale, preclinical, and clinical studies","volume":"128","author":"Mittal S","year":"2018","unstructured":"Mittal S, Klinger NV, Michelhaugh SK, Barger GR, Pannullo SC, Juh\u00e1sz C: Alternating electric tumor treating fields for treatment of glioblastoma: rationale, preclinical, and clinical studies. J Neurosurg 128:414\u2013421, 20182829802310.3171\/2016.9.JNS16452"},{"key":"b37","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.3171\/2010.2.JNS091528","article-title":"Simulation and assessment of cerebrovascular damage in deep brain stimulation using a stereotactic atlas of vasculature and structure derived from multiple 3- and 7-tesla scans","volume":"113","author":"Nowinski WL","year":"2010","unstructured":"Nowinski WL, Chua BC, Volkau I, Puspitasari F, Marchenko Y, Runge VM, : Simulation and assessment of cerebrovascular damage in deep brain stimulation using a stereotactic atlas of vasculature and structure derived from multiple 3- and 7-tesla scans. J Neurosurg 113:1234\u20131241, 20102034522610.3171\/2010.2.JNS091528"},{"key":"b38","series-title":"Piscataway, NJ: IEEE","first-page":"3476","article-title":"RFID STENTag for passive vascular monitoring, in Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP)","author":"Occhiuzzi C","year":"2011","unstructured":"Occhiuzzi C, Contri G, Marrocco G: RFID STENTag for passive vascular monitoring, in Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP). Piscataway, NJ: IEEE, 2011, pp 3476\u20133478 (https:\/\/ieeexplore.ieee.org\/document\/5782311\/) [Accessed June 14, 2018]"},{"key":"b39","series-title":"Neurosurgery","first-page":"1268","article-title":"Long-term hardware-related complications of deep brain stimulation","volume":"50","author":"Oh MY","year":"2002","unstructured":"Oh MY, Abosch A, Kim SH, Lang AE, Lozano AM: Long-term hardware-related complications of deep brain stimulation. Neurosurgery 50:1268\u20131276, 200212015845"},{"key":"b40","series-title":"IEEE Trans Biomed Eng","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1109\/TBME.2016.2552226","article-title":"Micro-CT and histological evaluation of an neural interface implanted within a blood vessel","volume":"64","author":"Opie NL","year":"2017","unstructured":"Opie NL, van der Nagel NR, John SE, Vessey K, Rind GS, Ronayne SM, : Micro-CT and histological evaluation of an neural interface implanted within a blood vessel. IEEE Trans Biomed Eng 64:928\u2013934, 201710.1109\/TBME.2016.255222627337706"},{"key":"b41","series-title":"Interv Neuroradiol","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1177\/1591019917753824","article-title":"Experience using pipeline embolization device with Shield Technology in a patient lacking a full postoperative dual antiplatelet therapy regimen","volume":"24","author":"Orlov K","year":"2018","unstructured":"Orlov K, Kislitsin D, Strelnikov N, Berestov V, Gorbatykh A, Shayakhmetov T, : Experience using pipeline embolization device with Shield Technology in a patient lacking a full postoperative dual antiplatelet therapy regimen. Interv Neuroradiol 24:270\u2013273, 201810.1177\/1591019917753824"},{"key":"b42","series-title":"Nat Biotechnol","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1038\/nbt.3428","article-title":"Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity","volume":"34","author":"Oxley TJ","year":"2016","unstructured":"Oxley TJ, Opie NL, John SE, Rind GS, Ronayne SM, Wheeler TL, : Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity. Nat Biotechnol 34:320\u2013327, 20162685447610.1038\/nbt.3428"},{"key":"b43","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"239","DOI":"10.3171\/jns.1973.38.2.0239","article-title":"Intravascular intracranial EEG recording. Technical note","volume":"38","author":"Penn RD","year":"1973","unstructured":"Penn RD, Hilal SK, Michelsen WJ, Goldensohn ES, Driller J: Intravascular intracranial EEG recording. Technical note. J Neurosurg 38:239\u2013243, 1973463283110.3171\/jns.1973.38.2.0239"},{"issue":"Suppl 3","key":"b44","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1227\/NEU.0000000000000864","article-title":"Feasibility, safety, and periprocedural complications of pipeline embolization for intracranial aneurysm treatment under conscious sedation: University at Buffalo Neurosurgery Experience","volume":"11","author":"Rangel-Castilla L","year":"2015","unstructured":"Rangel-Castilla L, Cress MC, Munich SA, Sonig A, Krishna C, Gu EY, : Feasibility, safety, and periprocedural complications of pipeline embolization for intracranial aneurysm treatment under conscious sedation: University at Buffalo Neurosurgery Experience. Neurosurgery 11 (Suppl 3):426\u2013430, 20152628435110.1227\/NEU.0000000000000864"},{"issue":"5","key":"b45","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2016.3.FOCUS15635","article-title":"The evolution of endovascular electroencephalography: historical perspective and future applications","volume":"40","author":"Sefcik RK","year":"2016","unstructured":"Sefcik RK, Opie NL, John SE, Kellner CP, Mocco J, Oxley TJ: The evolution of endovascular electroencephalography: historical perspective and future applications. Neurosurg Focus 40(5):E7, 20162713252810.3171\/2016.3.FOCUS15635"},{"key":"b46","series-title":"AJNR Am J Neuroradiol","first-page":"1214","article-title":"Intracranial electroencephalographic and evoked-potential recording from intravascular guide wires","volume":"16","author":"Stoeter P","year":"1995","unstructured":"Stoeter P, Dieterle L, Meyer A, Prey N: Intracranial electroencephalographic and evoked-potential recording from intravascular guide wires. AJNR Am J Neuroradiol 16:1214\u20131217, 19957677012"},{"key":"b47","series-title":"Piscataway NJ: IEEE","first-page":"1242","article-title":"Wirelessly powered implantable pacemaker with on-chip antenna, in 2017 IEEE MTT-S International Microwave Symposium (IMS)","author":"Sun Y","year":"2017","unstructured":"Sun Y, Greet B, Burkland D, John M, Razavi M, Babakhani A: Wirelessly powered implantable pacemaker with on-chip antenna, in 2017 IEEE MTT-S International Microwave Symposium (IMS). Piscataway NJ: IEEE, 2017, pp 1242\u20131244 (https:\/\/ieeexplore.ieee.org\/document\/8058831\/) [Accessed June 14, 2018]"},{"key":"b48","series-title":"N Engl J Med","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1056\/NEJMoa1107212","article-title":"Memory enhancement and deep-brain stimulation of the entorhinal area","volume":"366","author":"Suthana N","year":"2012","unstructured":"Suthana N, Haneef Z, Stern J, Mukamel R, Behnke E, Knowlton B, : Memory enhancement and deep-brain stimulation of the entorhinal area. N Engl J Med 366:502\u2013510, 20122231644410.1056\/NEJMoa1107212"},{"key":"b49","series-title":"J Neural Eng","doi-asserted-by":"publisher","first-page":"026011","DOI":"10.1088\/1741-2560\/11\/2\/026011","article-title":"Computational modeling of an endovascular approach to deep brain stimulation","volume":"11","author":"Teplitzky BA","year":"2014","unstructured":"Teplitzky BA, Connolly AT, Bajwa JA, Johnson MD: Computational modeling of an endovascular approach to deep brain stimulation. J Neural Eng 11:026011, 201410.1088\/1741-2560\/11\/2\/02601124608363"},{"key":"b50","series-title":"Ann Thorac Surg","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/S0003-4975(97)01351-9","article-title":"Bradycardia induced by intravascular versus direct stimulation of the vagus nerve","volume":"65","author":"Thompson GW","year":"1998","unstructured":"Thompson GW, Levett JM, Miller SM, Hill MR, Meffert WG, Kolata RJ, : Bradycardia induced by intravascular versus direct stimulation of the vagus nerve. Ann Thorac Surg 65:637\u2013642, 199810.1016\/S0003-4975(97)01351-99527187"},{"key":"b51","series-title":"eLife","doi-asserted-by":"publisher","first-page":"6","DOI":"10.7554\/eLife.29515","article-title":"Theta-burst microstimulation in the human entorhinal area improves memory specificity","volume":"6","author":"Titiz AS","year":"2017","unstructured":"Titiz AS, Hill MRH, Mankin EA, M Aghajan Z, Eliashiv D, Tchemodanov N, : Theta-burst microstimulation in the human entorhinal area improves memory specificity. eLife 6:6, 201710.7554\/eLife.29515"},{"key":"b52","series-title":"US patent application 2005\/0137646A1","article-title":"Scimed Life Systems, Inc., assignee: Method of intravascularly delivering stimulation leads into brain","author":"Wallace MP","unstructured":"Wallace MP, Garabedian RJ, Abrams RM, inventors; Scimed Life Systems, Inc., assignee: Method of intravascularly delivering stimulation leads into brain. US patent application 2005\/0137646A1. June 23, 2005"},{"key":"b53","series-title":"US patent 7,818,063B2","article-title":"Method of intravascularly delivering stimulation leads into brain to stimulate the SPG","author":"Wallace MP","unstructured":"Wallace MP, Garabedian RJ, Abrams RM, inventors; Boston Scientific Scimed, Inc., assignee: Method of intravascularly delivering stimulation leads into brain to stimulate the SPG. US patent 7,818,063B2. October 19, 2010"},{"key":"b54","series-title":"Electron Commun Jpn","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1002\/ecj.10058","article-title":"Intravascular neural interface with nanowire electrode","volume":"92","author":"Watanabe H","year":"2009","unstructured":"Watanabe H, Takahashi H, Nakao M, Walton K, Llin\u00e1s RR: Intravascular neural interface with nanowire electrode. Electron Commun Jpn 92:29\u201337, 20092157294010.1002\/ecj.10058"},{"key":"b55","series-title":"Neurosurgery","first-page":"N22","article-title":"Endovascular access for cortical mapping","volume":"79","author":"Weiner GM","year":"2016","unstructured":"Weiner GM, Ozpinar A, Ducruet A: Endovascular access for cortical mapping. Neurosurgery 79:N22\u2013N23, 2016"},{"key":"b56","series-title":"Conf Proc IEEE Eng Med Biol Soc","first-page":"2016","article-title":"Suitability of nitinol electrodes in neural prostheses such as endovascular neural interfaces","volume":"4463\u20134466","author":"Wong YT","year":"2016","unstructured":"Wong YT, Opie NL, John SE, Gerboni G, Rind GS, Ronayne SM, : Suitability of nitinol electrodes in neural prostheses such as endovascular neural interfaces. Conf Proc IEEE Eng Med Biol Soc 2016:4463\u20134466, 2016"},{"key":"b57","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1715","DOI":"10.3171\/2011.1.JNS101421","article-title":"Real-time control of a prosthetic hand using human electrocorticography signals","volume":"114","author":"Yanagisawa T","year":"2011","unstructured":"Yanagisawa T, Hirata M, Saitoh Y, Goto T, Kishima H, Fukuma R, : Real-time control of a prosthetic hand using human electrocorticography signals. J Neurosurg 114:1715\u20131722, 201110.3171\/2011.1.JNS10142121314273"},{"key":"b58","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.3171\/2009.10.JNS09332","article-title":"Gamma Knife thalamotomy for treatment of essential tremor: long-term results","volume":"112","author":"Young RF","year":"2010","unstructured":"Young RF, Li F, Vermeulen S, Meier R: Gamma Knife thalamotomy for treatment of essential tremor: long-term results. J Neurosurg 112:1311\u20131317, 201010.3171\/2009.10.JNS0933219895197"}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/45\/2\/article-pE19.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/45\/2\/article-pE19.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/45\/2\/article-pE19.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T08:54:48Z","timestamp":1780131288000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/45\/2\/article-pE19.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8]]},"references-count":116,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3171\/2018.4.focus18130","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8]]}}}