{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T19:48:13Z","timestamp":1792180093460,"version":"4.4.0"},"reference-count":16,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:p>Intracranial pressure (ICP) measurements are imperative for the proper diagnosis and treatment of several neurological disorders. Telemetric sensors have shown their utility for ICP estimation in short-term monitoring in humans. However, their long-term reliability is uncertain. The authors present the case of a 37-year-old woman diagnosed with benign intracranial hypertension and obesity. The patient underwent gastric bypass surgery for ICP control. In order to monitor ICP before and after bariatric surgery, a Neurovent-P-tel sensor was implanted in the left frontal lobe. After gastric bypass, normal ICP values were recorded, and the patient\u2019s visual fields improved. However, the patient experienced incapacitating daily headaches. The authors decided to implant a Codman Microsensor ICP transducer in the right frontal lobe to assess the long-term reliability of the Neurovent-P-tel measurements. A comparison of the recordings at 24 and 48 hours showed good correlation and reliability during long-term monitoring with the Neurovent-P-tel, with minimal zero drift after 11 months of implantation.<\/jats:p>","DOI":"10.3171\/2018.4.jns172988","type":"journal-article","created":{"date-parts":[[2018,8,31]],"date-time":"2018-08-31T13:59:46Z","timestamp":1535723986000},"page":"578-581","source":"Crossref","is-referenced-by-count":6,"title":["Long-term reliability of the telemetric Neurovent-P-tel sensor: in vivo case report"],"prefix":"10.3171","volume":"131","author":[{"given":"Jorge","family":"Tirado-Caballero","sequence":"first","affiliation":[{"name":"Neurosurgery Service, Virgen del Roc\u00edo University Hospital, Seville;"},{"name":"Group of Applied Neuroscience, Biomedicine Institute of Seville, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andres","family":"Mu\u00f1oz-Nu\u00f1ez","sequence":"additional","affiliation":[{"name":"Neurosurgery Service, Virgen del Roc\u00edo University Hospital, Seville;"},{"name":"Group of Applied Neuroscience, Biomedicine Institute of Seville, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Santiago","family":"Rocha-Romero","sequence":"additional","affiliation":[{"name":"Neurosurgery Service, Virgen del Roc\u00edo University Hospital, Seville;"},{"name":"Group of Applied Neuroscience, Biomedicine Institute of Seville, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M\u00f3nica","family":"Rivero-Garv\u00eda","sequence":"additional","affiliation":[{"name":"Neurosurgery Service, Virgen del Roc\u00edo University Hospital, Seville;"},{"name":"Group of Applied Neuroscience, Biomedicine Institute of Seville, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emilio","family":"Gomez-Gonz\u00e1lez","sequence":"additional","affiliation":[{"name":"Group of Interdisciplinary Physics, University of Seville; and"},{"name":"Group of Applied Neuroscience, Biomedicine Institute of Seville, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier","family":"Marquez-Rivas","sequence":"additional","affiliation":[{"name":"Neurosurgery Service, Virgen del Roc\u00edo University Hospital, Seville;"},{"name":"Group of Applied Neuroscience, Biomedicine Institute of Seville, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1227\/01.NEU.0000328392.98602.5A","article-title":"Assessment of zero drift in the Codman intracranial pressure monitor: a study from 2 neurointensive care units","volume":"64","author":"Al-Tamimi YZ","year":"2009","unstructured":"Al-Tamimi YZ, Helmy A, Bavetta S, Price SJ: Assessment of zero drift in the Codman intracranial pressure monitor: a study from 2 neurointensive care units. Neurosurgery 64:94\u201399, 200910.1227\/01.NEU.0000328392.98602.5A"},{"key":"b2","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.wneu.2016.03.096","article-title":"Telemetric intracranial pressure monitoring with the Raumedic Neurovent P-tel","volume":"91","author":"Antes S","year":"2016","unstructured":"Antes S, Tschan CA, Heckelmann M, Breuskin D, Oertel J: Telemetric intracranial pressure monitoring with the Raumedic Neurovent P-tel. World Neurosurg 91:133\u2013148, 20162706051510.1016\/j.wneu.2016.03.096"},{"key":"b3","series-title":"Chin J Traumatol","first-page":"99","article-title":"Zero drift of intraventricular and subdural intracranial pressure monitoring systems","volume":"16","author":"Chen L","year":"2013","unstructured":"Chen L, Du HG, Yin LC, He M, Zhang GJ, Tian Y, : Zero drift of intraventricular and subdural intracranial pressure monitoring systems. Chin J Traumatol 16:99\u2013102, 201323540898"},{"key":"b4","series-title":"Surg Neurol","first-page":"287","article-title":"A telemetric pressure sensor for ventricular shunt systems","volume":"11","author":"Cosman ER","year":"1979","unstructured":"Cosman ER, Zervas NT, Chapman PH, Cosman BJ, Arnold MA: A telemetric pressure sensor for ventricular shunt systems. Surg Neurol 11:287\u2013294, 1979441915"},{"key":"b5","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1007\/BF01769143","article-title":"Epidural pressure monitoring with the so-called Rotterdam transducer. Further in vivo results","volume":"45","author":"de Jong DA","year":"1979","unstructured":"de Jong DA, Berfelo MW, de Lange SA, Maas AI: Epidural pressure monitoring with the so-called Rotterdam transducer. Further in vivo results. Acta Neurochir (Wien) 45:301\u2013309, 197910.1007\/BF01769143"},{"key":"b6","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1007\/s00701-005-0683-3","article-title":"The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases","volume":"148","author":"Gelabert-Gonz\u00e1lez M","year":"2006","unstructured":"Gelabert-Gonz\u00e1lez M, Ginesta-Galan V, Sernamito-Garc\u00eda R, Allut AG, Bandin-Di\u00e9guez J, Rumbo RM: The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases. Acta Neurochir (Wien) 148:435\u2013441, 200610.1007\/s00701-005-0683-3"},{"key":"b7","series-title":"Surg Obes Relat Dis","doi-asserted-by":"publisher","first-page":"1396","DOI":"10.1016\/j.soard.2015.08.497","article-title":"Bariatric surgery as a treatment for idiopathic intracranial hypertension: a systematic review","volume":"11","author":"Handley JD","year":"2015","unstructured":"Handley JD, Baruah BP, Williams DM, Horner M, Barry J, Stephens JW: Bariatric surgery as a treatment for idiopathic intracranial hypertension: a systematic review. Surg Obes Relat Dis 11:1396\u20131403, 20152649935010.1016\/j.soard.2015.08.497"},{"key":"b8","series-title":"Acta Neurochir Suppl (Wien)","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/978-3-7091-0956-4_20","article-title":"Telemetric ICP measurement with the first CE-approved device: data from animal experiments and initial clinical experiences","volume":"114","author":"Kiefer M","year":"2012","unstructured":"Kiefer M, Antes S, Leonhardt S, Schmitt M, Orakcioglu B, Sakowitz OW, : Telemetric ICP measurement with the first CE-approved device: data from animal experiments and initial clinical experiences. Acta Neurochir Suppl (Wien) 114:111\u2013116, 201210.1007\/978-3-7091-0956-4_20"},{"key":"b9","series-title":"Clin Neurol Neurosurg","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.clineuro.2014.02.010","article-title":"Clinical experience with telemetric intracranial pressure monitoring in a Danish neurosurgical center","volume":"120","author":"Lilja A","year":"2014","unstructured":"Lilja A, Andresen M, Hadi A, Christoffersen D, Juhler M: Clinical experience with telemetric intracranial pressure monitoring in a Danish neurosurgical center. Clin Neurol Neurosurg 120:36\u201340, 201410.1016\/j.clineuro.2014.02.010"},{"key":"b10","series-title":"Childs Nerv Syst","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1007\/s00381-016-3023-4","article-title":"Telemetric intracranial pressure monitoring: a noninvasive method to follow up children with complex craniosynostoses. A case report","volume":"32","author":"Magn\u00e9li S","year":"2016","unstructured":"Magn\u00e9li S, Howells T, Saiepour D, Nowinski D, Enblad P, Nilsson P: Telemetric intracranial pressure monitoring: a noninvasive method to follow up children with complex craniosynostoses. A case report. Childs Nerv Syst 32:1311\u20131315, 201610.1007\/s00381-016-3023-426861131"},{"key":"b11","series-title":"Neurologia","first-page":"303","article-title":"[Intracranial pressure monitoring and CSF dynamics in patients with neurological disorders: indications and practical considerations.]","volume":"16","author":"Poca M","year":"2001","unstructured":"Poca M, Sahuquillo J: [Intracranial pressure monitoring and CSF dynamics in patients with neurological disorders: indications and practical considerations.] Neurologia 16:303\u2013320, 2001 (Span)11485723"},{"key":"b12","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1007\/s00701-010-0905-1","article-title":"Reduction in external ventricular drain infection rate. Impact of a minimal handling protocol and antibiotic-impregnated catheters","volume":"153","author":"Rivero-Garv\u00eda M","year":"2011","unstructured":"Rivero-Garv\u00eda M, M\u00e1rquez-Rivas J, Jim\u00e9nez-Mej\u00edas ME, Neth O, Rueda-Torres AB: Reduction in external ventricular drain infection rate. Impact of a minimal handling protocol and antibiotic-impregnated catheters. Acta Neurochir (Wien) 153:647\u2013651, 201110.1007\/s00701-010-0905-1"},{"key":"b13","series-title":"Neurologia","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.nrl.2012.09.002","article-title":"Basic concepts about brain pathophysiology and intracranial pressure monitoring","volume":"30","author":"Rodr\u00edguez-Boto G","year":"2015","unstructured":"Rodr\u00edguez-Boto G, Rivero-Garv\u00eda M, Guti\u00e9rrez-Gonz\u00e1lez R, M\u00e1rquez-Rivas J: Basic concepts about brain pathophysiology and intracranial pressure monitoring. Neurologia 30:16\u201322, 20152324621210.1016\/j.nrl.2012.09.002"},{"key":"b14","series-title":"Acta Neurochir Suppl","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/978-3-7091-0923-6_22","article-title":"Subdural or intraparenchymal placement of long-term telemetric intracranial pressure measurement devices?","volume":"113","author":"Schmitt M","year":"2012","unstructured":"Schmitt M, Eymann R, Antes S, Kiefer M: Subdural or intraparenchymal placement of long-term telemetric intracranial pressure measurement devices? Acta Neurochir Suppl 113:109\u2013113, 20122211643410.1007\/978-3-7091-0923-6_22"},{"key":"b15","series-title":"Ann Surg","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1097\/00000658-199905000-00005","article-title":"Gastric surgery for pseudotumor cerebri associated with severe obesity","volume":"229","author":"Sugerman HJ","year":"1999","unstructured":"Sugerman HJ, Felton WL III, Sismanis A, Kellum JM, DeMaria EJ, Sugerman EL: Gastric surgery for pseudotumor cerebri associated with severe obesity. Ann Surg 229:634\u2013642, 199910.1097\/00000658-199905000-0000510235521"},{"key":"b16","series-title":"Crit Care","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1186\/s13054-015-1137-9","article-title":"Accuracy of intracranial pressure monitoring: systematic review and meta-analysis","volume":"19","author":"Zacchetti L","year":"2015","unstructured":"Zacchetti L, Magnoni S, Di Corte F, Zanier ER, Stocchetti N: Accuracy of intracranial pressure monitoring: systematic review and meta-analysis. Crit Care 19:420, 201510.1186\/s13054-015-1137-926627204"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/131\/2\/article-p578.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/131\/2\/article-p578.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/131\/2\/article-p578.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,23]],"date-time":"2025-03-23T04:05:57Z","timestamp":1742702757000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/131\/2\/article-p578.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":16,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3171\/2018.4.jns172988","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8]]}}}