{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:02:43Z","timestamp":1787025763355,"version":"build-2736575974"},"reference-count":23,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Lateral mass fixation stabilizes the cervical spine while causing minimal morbidity and resulting in high fusion rates. Still, with 2 years of follow-up, approximately 6% of patients who have undergone posterior cervical fusion have worsening kyphosis or symptomatic adjacent-segment disease. Based on the length of the construct, the question of whether to extend the fixation system to undisrupted levels has not been answered for the cervical spine. The authors conducted a study to quantify the role of construct length and the terminal dorsal ligamentous complex in the adjacent-segment kinematics of the subaxial cervical spine.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>In vitro flexibility testing was performed using 6 human cadaveric specimens (C2\u2013T8), with the upper thoracic rib cage and osseous and ligamentous integrity intact. An industrial robot was used to apply pure moments and to measure segmental motion at each level. The authors tested the intact state, followed by 9 postsurgical permutations of laminectomy and lateral mass fixation spanning C2 to C7.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>Constructs spanning a single level exerted no significant effects on immediate adjacent-segment motion. The addition of a second immobilized segment, however, created significant changes in flexion-extension range of motion at the supradjacent level (+164%). Regardless of construct length, resection of the terminal dorsal ligaments did not greatly affect adjacent-level motion except at C2\u20133 and C7\u2013T1 (increasing by +794% and +607%, respectively).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>Dorsal ligamentous support was found to contribute significant stability to the C2\u20133 and C7\u2013T1 segments only. Construct length was found to play a significant role when fixating two or more segments. The addition of a fused segment to support an undisrupted cervical level is not suggested by the present data, except potentially at C2\u20133 and C7\u2013T1. The study findings emphasize the importance of the C2\u20133 segment and its dorsal support.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2019.7.spine19279","type":"journal-article","created":{"date-parts":[[2019,10,19]],"date-time":"2019-10-19T04:29:06Z","timestamp":1571459346000},"page":"15-22","source":"Crossref","is-referenced-by-count":6,"title":["Analysis of adjacent-segment cervical kinematics: the role of construct length and the dorsal ligamentous complex"],"prefix":"10.3171","volume":"32","author":[{"given":"Daniel","family":"Lubelski","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew T.","family":"Healy","sequence":"additional","affiliation":[{"name":"Carolina Neurosurgery and Spine Associates, Greensboro, North Carolina;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prasath","family":"Mageswaran","sequence":"additional","affiliation":[{"name":"Spine Research Institute, Ohio State University, Columbus;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robb","family":"Colbrunn","sequence":"additional","affiliation":[{"name":"Cleveland Clinic Lerner Research Institute; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard P.","family":"Schlenk","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cleveland Clinic, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"22 Suppl","key":"b1","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S85","DOI":"10.1097\/BRS.0b013e31826d6628","article-title":"Kinematics of the cervical adjacent segments after disc arthroplasty compared with anterior discectomy and fusion: a systematic review and meta-analysis","volume":"37","author":"Anderson PA","year":"2012","unstructured":"Anderson PA, Sasso RC, Hipp J, Norvell DC, Raich A, Hashimoto R: Kinematics of the cervical adjacent segments after disc arthroplasty compared with anterior discectomy and fusion: a systematic review and meta-analysis. Spine (Phila Pa 1976) 37 (22 Suppl):S85\u2013S95, 201210.1097\/BRS.0b013e31826d6628"},{"key":"b2","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.1097\/00007632-199311000-00004","article-title":"Late radiographic findings after anterior cervical fusion for spondylotic myeloradiculopathy","volume":"18","author":"Baba H","year":"1993","unstructured":"Baba H, Furusawa N, Imura S, Kawahara N, Tsuchiya H, Tomita K: Late radiographic findings after anterior cervical fusion for spondylotic myeloradiculopathy. Spine (Phila Pa 1976) 18:2167\u20132173, 199310.1097\/00007632-199311000-00004"},{"key":"b3","series-title":"Biomechanics of Spine Stabilization","year":"2001","unstructured":"Benzel EC (ed): Biomechanics of Spine Stabilization, ed 1. Stuttgart: Thieme\/AANS, 2001"},{"key":"b4","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E500","DOI":"10.1097\/BRS.0000000000000222","article-title":"Biomechanical risk factors for proximal junctional kyphosis: a detailed numerical analysis of surgical instrumentation variables","volume":"39","author":"Cammarata M","year":"2014","unstructured":"Cammarata M, Aubin C\u00c9, Wang X, Mac-Thiong JM: Biomechanical risk factors for proximal junctional kyphosis: a detailed numerical analysis of surgical instrumentation variables. Spine (Phila Pa 1976) 39:E500\u2013E507, 201410.1097\/BRS.0000000000000222"},{"issue":"19 Suppl","key":"b5","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S144","DOI":"10.1097\/01.brs.0000236893.65878.39","article-title":"Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65: surgical considerations and treatment options in patients with poor bone quality","volume":"31","author":"DeWald CJ","year":"2006","unstructured":"DeWald CJ, Stanley T: Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65: surgical considerations and treatment options in patients with poor bone quality. Spine (Phila Pa 1976) 31 (19 Suppl):S144\u2013S151, 200610.1097\/01.brs.0000236893.65878.39"},{"key":"b6","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E188","DOI":"10.1097\/01.brs.0000257577.70576.07","article-title":"Stabilizing potential of anterior, posterior, and circumferential fixation for multilevel cervical arthrodesis: an in vitro human cadaveric study of the operative and adjacent segment kinematics","volume":"32","author":"Dmitriev AE","year":"2007","unstructured":"Dmitriev AE, Kuklo TR, Lehman RA Jr, Rosner MK: Stabilizing potential of anterior, posterior, and circumferential fixation for multilevel cervical arthrodesis: an in vitro human cadaveric study of the operative and adjacent segment kinematics. Spine (Phila Pa 1976) 32:E188\u2013E196, 200710.1097\/01.brs.0000257577.70576.07"},{"key":"b7","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1097\/00007632-199808010-00006","article-title":"A kinematic study of the cervical spine before and after segmental arthrodesis","volume":"23","author":"Fuller DA","year":"1998","unstructured":"Fuller DA, Kirkpatrick JS, Emery SE, Wilber RG, Davy DT: A kinematic study of the cervical spine before and after segmental arthrodesis. Spine (Phila Pa 1976) 23:1649\u20131656, 199810.1097\/00007632-199808010-00006"},{"issue":"Suppl 2","key":"b8","series-title":"J Bone Joint Surg Am","first-page":"103","article-title":"Test protocols for evaluation of spinal implants","volume":"88","author":"Goel VK","year":"2006","unstructured":"Goel VK, Panjabi MM, Patwardhan AG, Dooris AP, Serhan H: Test protocols for evaluation of spinal implants. J Bone Joint Surg Am 88 (Suppl 2):103\u2013109, 200616595454"},{"key":"b9","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"619","DOI":"10.3171\/2011.1.SPINE10206","article-title":"Treatment of cervical stenotic myelopathy: a cost and outcome comparison of laminoplasty versus laminectomy and lateral mass fusion","volume":"14","author":"Highsmith JM","year":"2011","unstructured":"Highsmith JM, Dhall SS, Haid RW Jr, Rodts GE Jr, Mummaneni PV: Treatment of cervical stenotic myelopathy: a cost and outcome comparison of laminoplasty versus laminectomy and lateral mass fusion. J Neurosurg Spine 14:619\u2013625, 201110.3171\/2011.1.SPINE1020621388285"},{"key":"b10","series-title":"J Bone Joint Surg Am","doi-asserted-by":"publisher","first-page":"519","DOI":"10.2106\/00004623-199904000-00009","article-title":"Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis","volume":"81","author":"Hilibrand AS","year":"1999","unstructured":"Hilibrand AS, Carlson GD, Palumbo MA, Jones PK, Bohlman HH: Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis. J Bone Joint Surg Am 81:519\u2013528, 199910.2106\/00004623-199904000-00009"},{"key":"b11","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/j.spinee.2013.02.062","article-title":"Biomechanics of adjacent segments after a multilevel cervical corpectomy using anterior, posterior, and combined anterior-posterior instrumentation techniques: a finite element model study","volume":"13","author":"Hussain M","year":"2013","unstructured":"Hussain M, Nassr A, Natarajan RN, An HS, Andersson GBJ: Biomechanics of adjacent segments after a multilevel cervical corpectomy using anterior, posterior, and combined anterior-posterior instrumentation techniques: a finite element model study. Spine J 13:689\u2013696, 20132357898910.1016\/j.spinee.2013.02.062"},{"issue":"2 Suppl","key":"b12","series-title":"J Neurosurg","first-page":"199","article-title":"Incidence and outcome of kyphotic deformity following laminectomy for cervical spondylotic myelopathy","volume":"93","author":"Kaptain GJ","year":"2000","unstructured":"Kaptain GJ, Simmons NE, Replogle RE, Pobereskin L: Incidence and outcome of kyphotic deformity following laminectomy for cervical spondylotic myelopathy. J Neurosurg 93 (2 Suppl):199\u2013204, 200011012049"},{"issue":"6 Suppl","key":"b13","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"252S","DOI":"10.1016\/j.spinee.2006.04.029","article-title":"Surgical management of cervical myelopathy: indications and techniques for laminectomy and fusion","volume":"6","author":"Komotar RJ","year":"2006","unstructured":"Komotar RJ, Mocco J, Kaiser MG: Surgical management of cervical myelopathy: indications and techniques for laminectomy and fusion. Spine J 6 (6 Suppl):252S\u2013267S, 200610.1016\/j.spinee.2006.04.02917097545"},{"key":"b14","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E778","DOI":"10.1097\/BRS.0b013e31824780b8","article-title":"Adjacent-level range of motion and intradiscal pressure after posterior cervical decompression and fixation: an in vitro human cadaveric model","volume":"37","author":"Kretzer RM","year":"2012","unstructured":"Kretzer RM, Hsu W, Hu N, Umekoji H, Jallo GI, McAfee PC, : Adjacent-level range of motion and intradiscal pressure after posterior cervical decompression and fixation: an in vitro human cadaveric model. Spine (Phila Pa 1976) 37:E778\u2013E785, 201210.1097\/BRS.0b013e31824780b8"},{"key":"b15","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"435","DOI":"10.3171\/2010.4.SPINE09995","article-title":"The effect of spinal instrumentation on kinematics at the cervicothoracic junction: emphasis on soft-tissue response in an in vitro human cadaveric model","volume":"13","author":"Kretzer RM","year":"2010","unstructured":"Kretzer RM, Hu N, Umekoji H, Sciubba DM, Jallo GI, McAfee PC, : The effect of spinal instrumentation on kinematics at the cervicothoracic junction: emphasis on soft-tissue response in an in vitro human cadaveric model. J Neurosurg Spine 13:435\u2013442, 201010.3171\/2010.4.SPINE09995"},{"key":"b16","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"771","DOI":"10.1097\/00006123-199904000-00046","article-title":"Cervical spondylotic myelopathy: functional and radiographic long-term outcome after laminectomy and posterior fusion","volume":"44","author":"Kumar VG","year":"1999","unstructured":"Kumar VG, Rea GL, Mervis LJ, McGregor JM: Cervical spondylotic myelopathy: functional and radiographic long-term outcome after laminectomy and posterior fusion. Neurosurgery 44:771\u2013778, 19991020130210.1097\/00006123-199904000-00046"},{"key":"b17","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"172","DOI":"10.3171\/2011.10.SPINE11116","article-title":"Adjacent-level biomechanics after single versus multilevel cervical spine fusion","volume":"16","author":"Prasarn ML","year":"2012","unstructured":"Prasarn ML, Baria D, Milne E, Latta L, Sukovich W: Adjacent-level biomechanics after single versus multilevel cervical spine fusion. J Neurosurg Spine 16:172\u2013177, 201210.3171\/2011.10.SPINE1111622136389"},{"key":"b18","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1097\/00024720-200608000-00006","article-title":"A quantitative analysis of strain at adjacent segments after segmental immobilization of the cervical spine","volume":"19","author":"Ragab AA","year":"2006","unstructured":"Ragab AA, Escarcega AJ, Zdeblick TA: A quantitative analysis of strain at adjacent segments after segmental immobilization of the cervical spine. J Spinal Disord Tech 19:407\u2013410, 200610.1097\/00024720-200608000-0000616891975"},{"key":"b19","series-title":"J Clin Neurosci","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.jocn.2005.02.006","article-title":"Posterior cervical decompression and fusion for circumferential spondylotic cervical stenosis: review of 50 consecutive cases","volume":"13","author":"Sekhon LHS","year":"2006","unstructured":"Sekhon LHS: Posterior cervical decompression and fusion for circumferential spondylotic cervical stenosis: review of 50 consecutive cases. J Clin Neurosci 13:23\u201330, 200610.1016\/j.jocn.2005.02.00616410194"},{"key":"b20","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1227\/NEU.0b013e31826100c9","article-title":"The impact of standing regional cervical sagittal alignment on outcomes in posterior cervical fusion surgery","volume":"71","author":"Tang JA","year":"2012","unstructured":"Tang JA, Scheer JK, Smith JS, Deviren V, Bess S, Hart RA, : The impact of standing regional cervical sagittal alignment on outcomes in posterior cervical fusion surgery. Neurosurgery 71:662\u2013669, 20122265339510.1227\/NEU.0b013e31826100c9"},{"key":"b21","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"E520","DOI":"10.1093\/neuros\/nyz019","article-title":"Reoperation for proximal adjacent segment pathology in posterior cervical fusion constructs that fuse to C2 vs C3","volume":"85","author":"Xia Y","year":"2019","unstructured":"Xia Y, Xu R, Kosztowski TA, Ramhmdani S, Ahmed AK, Lo SL, : Reoperation for proximal adjacent segment pathology in posterior cervical fusion constructs that fuse to C2 vs C3. Neurosurgery 85:E520\u2013E526, 201910.1093\/neuros\/nyz01930860261"},{"key":"b22","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"2719","DOI":"10.1007\/s00586-013-2992-1","article-title":"Biomechanical comparison of laminectomy, hemilaminectomy and a new minimally invasive approach in the surgical treatment of multilevel cervical intradural tumour: a finite element analysis","volume":"22","author":"Xie T","year":"2013","unstructured":"Xie T, Qian J, Lu Y, Chen B, Jiang Y, Luo C: Biomechanical comparison of laminectomy, hemilaminectomy and a new minimally invasive approach in the surgical treatment of multilevel cervical intradural tumour: a finite element analysis. Eur Spine J 22:2719\u20132730, 201310.1007\/s00586-013-2992-1"},{"key":"b23","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1007\/s00586-013-2817-2","article-title":"Anterior approach versus posterior approach for the treatment of multilevel cervical spondylotic myelopathy: a systemic review and meta-analysis","volume":"22","author":"Zhu B","year":"2013","unstructured":"Zhu B, Xu Y, Liu X, Liu Z, Dang G: Anterior approach versus posterior approach for the treatment of multilevel cervical spondylotic myelopathy: a systemic review and meta-analysis. Eur Spine J 22:1583\u20131593, 20132365762410.1007\/s00586-013-2817-2"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/32\/1\/article-p15.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/32\/1\/article-p15.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/32\/1\/article-p15.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T18:49:08Z","timestamp":1681584548000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/32\/1\/article-p15.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":23,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3171\/2019.7.spine19279","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}