{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T23:56:27Z","timestamp":1784937387741,"version":"3.55.0"},"reference-count":20,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,8]]},"abstract":"<jats:sec><jats:title>OBJECTIVE<\/jats:title><jats:p>The objective of the current study was to quantify and compare the multidirectional flexibility properties of occipital anchor fixation with conventional methods of occipitocervical screw fixation using nondestructive and destructive investigative methods.<\/jats:p><\/jats:sec><jats:sec><jats:title>METHODS<\/jats:title><jats:p>Fourteen cadaveric occipitocervical specimens (Oc\u2013T2) were randomized to reconstruction with occipital anchors or an occipital plate and screws. Using a 6-degree-of-freedom spine simulator with moments of \u00b1 2.0 Nm, initial multidirectional flexibility analysis of the intact and reconstructed conditions was performed followed by fatigue loading of 25,000 cycles of flexion-extension (x-axis, \u00b1 2.0 Nm), 15,000 cycles of lateral bending (z-axis, \u00b1 2.0 Nm), and 10,000 cycles of axial rotation (y-axis, \u00b1 2.0 Nm). Fluoroscopic images of the implantation sites were obtained before and after fatigue testing and placed on an x-y coordinate system to quantify positional stability of the anchors and screws used for reconstruction and effect, if any, of the fatigue component. Destructive testing included an anterior flexural load to construct failure. Quantification of implant, occipitocervical, and atlantoaxial junction range of motion is reported as absolute values, and peak flexural failure moment in Newton-meters (Nm).<\/jats:p><\/jats:sec><jats:sec><jats:title>RESULTS<\/jats:title><jats:p>Absolute value comparisons between the intact condition and 2 reconstruction groups demonstrated significant reductions in segmental flexion-extension, lateral bending, and axial rotation motion at the Oc\u2013C1 and C1\u20132 junctions (p &lt; 0.05). The average bone mineral density at the midline keel (1.422 g\/cm<jats:sup>3<\/jats:sup>) was significantly higher compared with the lateral occipital region at 0.671 g\/cm<jats:sup>3<\/jats:sup> (p &lt; 0.05). There were no significant differences between the occipital anchor and plate treatments in terms of angular rotation (degrees; p = 0.150) or x-axis displacement (mm; p = 0.572), but there was a statistically significant difference in y-axis displacement (p = 0.031) based on quantitative analysis of the pre- and postfatigue fluoroscopic images (p &gt; 0.05). Under destructive anterior flexural loading, the occipital anchor group failed at 90 \u00b1 31 Nm, and the occipital plate group failed at 79 \u00b1 25 Nm (p &gt; 0.05).<\/jats:p><\/jats:sec><jats:sec><jats:title>CONCLUSIONS<\/jats:title><jats:p>Both reconstructions reduced flexion-extension, lateral bending, and axial rotation at the occipitocervical and atlantoaxial junctions, as expected. Flexural load to failure did not differ significantly between the 2 treatment groups despite occipital anchors using a compression-fit mechanism to provide fixation in less dense bone. These data suggest that an occipital anchor technique serves as a biomechanically viable clinical alternative to occipital plate fixation.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2020.1.spine191331","type":"journal-article","created":{"date-parts":[[2020,4,10]],"date-time":"2020-04-10T13:09:12Z","timestamp":1586524152000},"page":"138-147","source":"Crossref","is-referenced-by-count":5,"title":["Biomechanical analysis of occipitocervical stabilization techniques: emphasis on integrity of osseous structures at the occipital implantation sites"],"prefix":"10.3171","volume":"33","author":[{"given":"Bryan W.","family":"Cunningham","sequence":"first","affiliation":[{"name":"Musculoskeletal Education Center, Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, Maryland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyle B.","family":"Mueller","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Georgetown University Medical Center, Washington, DC; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth P.","family":"Mullinix","sequence":"additional","affiliation":[{"name":"Musculoskeletal Education Center, Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, Maryland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaolei","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Tianjin Hospital, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Faheem A.","family":"Sandhu","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Georgetown University Medical Center, Washington, DC; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"4","key":"b1","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E2","DOI":"10.3171\/2015.1.FOCUS14807","article-title":"Anatomy and biomechanics of the craniovertebral junction","volume":"38","author":"Lopez AJ","year":"2015","unstructured":"Lopez AJ, Scheer JK, Leibl KE,  Anatomy and biomechanics of the craniovertebral junction. Neurosurg Focus. 2015;38(4):E2.10.3171\/2015.1.FOCUS1480725828496"},{"issue":"4","key":"b2","series-title":"Orthop Clin North Am","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1016\/S0030-5898(20)32199-4","article-title":"The clinical biomechanics of the occipitoatlantoaxial complex","volume":"9","author":"White AA III","year":"1978","unstructured":"White AA III, Panjabi MM. The clinical biomechanics of the occipitoatlantoaxial complex. Orthop Clin North Am. 1978;9(4):867\u2013878.10.1016\/S0030-5898(20)32199-4740380"},{"issue":"3","key":"b3","series-title":"J Bone Joint Surg Br","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1302\/0301-620X.51B3.423","article-title":"Occipito-cervical fusion. An operative technique and its indications","volume":"51","author":"Newman P","year":"1969","unstructured":"Newman P, Sweetnam R. Occipito-cervical fusion. An operative technique and its indications. J Bone Joint Surg Br. 1969;51(3):423\u2013431.10.1302\/0301-620X.51B3.4235820784"},{"issue":"1","key":"b4","series-title":"J Bone Joint Surg Am","doi-asserted-by":"publisher","first-page":"37","DOI":"10.2106\/00004623-195941010-00006","article-title":"Total cervical-spine fusion for neck paralysis","volume":"41-A","author":"Perry J","year":"1959","unstructured":"Perry J, Nickel VL. Total cervical-spine fusion for neck paralysis. J Bone Joint Surg Am. 1959;41-A(1):37\u201360.10.2106\/00004623-195941010-00006"},{"issue":"14","key":"b5","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.1097\/00007632-199607150-00004","article-title":"Threaded Steinmann pin fusion of the craniovertebral junction","volume":"21","author":"Apostolides PJ","year":"1996","unstructured":"Apostolides PJ, Dickman CA, Golfinos JG,  Threaded Steinmann pin fusion of the craniovertebral junction. Spine (Phila Pa 1976). 1996;21(14):1630\u20131637.10.1097\/00007632-199607150-00004"},{"issue":"7","key":"b6","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1097\/00007632-200104010-00026","article-title":"A technique of occipitocervical arthrodesis in children using autologous rib grafts","volume":"26","author":"Cohen MW","year":"2001","unstructured":"Cohen MW, Drummond DS, Flynn JM,  A technique of occipitocervical arthrodesis in children using autologous rib grafts. Spine (Phila Pa 1976). 2001;26(7):825\u2013829.10.1097\/00007632-200104010-00026"},{"issue":"14","key":"b7","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1425","DOI":"10.1097\/00007632-199907150-00007","article-title":"Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems","volume":"24","author":"Abumi K","year":"1999","unstructured":"Abumi K, Takada T, Shono Y,  Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine (Phila Pa 1976). 1999;24(14):1425\u20131434.10.1097\/00007632-199907150-00007"},{"issue":"4","key":"b8","series-title":"Turk Neurosurg","first-page":"558","article-title":"Occipitocervical fixation using occipital bone hooks and cervical lateral mass screws: analysis of 16 cases","volume":"24","author":"Akbay A","year":"2014","unstructured":"Akbay A, Isikay I, Orunoglu M. Occipitocervical fixation using occipital bone hooks and cervical lateral mass screws: analysis of 16 cases. Turk Neurosurg. 2014;24(4):558\u2013564.25050682"},{"issue":"7","key":"b9","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1097\/01.brs.0000206366.20414.87","article-title":"Biomechanics of occipitocervical fixation","volume":"31","author":"Anderson PA","year":"2006","unstructured":"Anderson PA, Oza AL, Puschak TJ, Sasso R. Biomechanics of occipitocervical fixation. Spine (Phila Pa 1976). 2006;31(7):755\u2013761.10.1097\/01.brs.0000206366.20414.87"},{"issue":"8","key":"b10","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199108001-00001","article-title":"The effect of the three columns of the spine on the instantaneous axis of rotation in flexion and extension","volume":"16","author":"Haher TR","year":"1991","unstructured":"Haher TR, Bergman M, O\u2019Brien M,  The effect of the three columns of the spine on the instantaneous axis of rotation in flexion and extension. Spine (Phila Pa 1976). 1991;16(8)(suppl):S312\u2013S318.10.1097\/00007632-199108001-00001"},{"issue":"1","key":"b11","series-title":"J Neurosurg","article-title":"A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation","volume":"90","author":"Hurlbert RJ","year":"1999","unstructured":"Hurlbert RJ, Crawford NR, Choi WG, Dickman CA. A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation. J Neurosurg. 1999;90(1)(suppl):84\u201390.10413131"},{"issue":"22","key":"b12","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2377","DOI":"10.1097\/00007632-199911150-00015","article-title":"Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques","volume":"24","author":"Oda I","year":"1999","unstructured":"Oda I, Abumi K, Sell LC,  Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques. Spine (Phila Pa 1976). 1999;24(22):2377\u20132382.10.1097\/00007632-199911150-00015"},{"issue":"18","key":"b13","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"2303","DOI":"10.1097\/00007632-200009150-00007","article-title":"Biomechanical properties of anterior thoracolumbar multisegmental fixation: an analysis of construct stiffness and screw-rod strain","volume":"25","author":"Oda I","year":"2000","unstructured":"Oda I, Cunningham BW, Lee GA,  Biomechanical properties of anterior thoracolumbar multisegmental fixation: an analysis of construct stiffness and screw-rod strain. Spine (Phila Pa 1976). 2000;25(18):2303\u20132311.10.1097\/00007632-200009150-00007"},{"issue":"1","key":"b14","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E9","DOI":"10.3171\/foc.2004.16.1.10","article-title":"The evolution of posterior cervical and occipitocervical fusion and instrumentation","volume":"16","author":"Vender JR","year":"2004","unstructured":"Vender JR, Rekito AJ, Harrison SJ, McDonnell DE. The evolution of posterior cervical and occipitocervical fusion and instrumentation. Neurosurg Focus. 2004;16(1):E9.1526478710.3171\/foc.2004.16.1.10"},{"issue":"1","key":"b15","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"8","DOI":"10.3171\/2014.11.SPINE14484","article-title":"Correction of clivoaxial angle deformity in the setting of suboccipital craniectomy: technical note","volume":"23","author":"Felbaum D","year":"2015","unstructured":"Felbaum D, Spitz S, Sandhu FA. Correction of clivoaxial angle deformity in the setting of suboccipital craniectomy: technical note. J Neurosurg Spine. 2015;23(1):8\u201315.10.3171\/2014.11.SPINE1448425860518"},{"issue":"1","key":"b16","series-title":"J Neurosurg","article-title":"Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results","volume":"90","author":"Pait TG","year":"1999","unstructured":"Pait TG, Al-Mefty O, Boop FA,  Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results. J Neurosurg. 1999;90(1)(suppl):1\u20137.10413118"},{"issue":"4","key":"b17","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1097\/01.BRS.0000048460.58471.DB","article-title":"Occipitocervical fusion for rheumatoid arthritis using the inside-outside stabilization technique","volume":"28","author":"Sandhu FA","year":"2003","unstructured":"Sandhu FA, Pait TG, Benzel E, Henderson FC. Occipitocervical fusion for rheumatoid arthritis using the inside-outside stabilization technique. Spine (Phila Pa 1976). 2003;28(4):414\u2013419.10.1097\/01.BRS.0000048460.58471.DB"},{"issue":"10","key":"b18","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1097\/00007632-198810000-00013","article-title":"Biomechanical evaluation of spinal fixation devices: I. A conceptual framework","volume":"13","author":"Panjabi MM","year":"1988","unstructured":"Panjabi MM. Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine (Phila Pa 1976). 1988;13(10):1129\u20131134.10.1097\/00007632-198810000-00013"},{"issue":"15","key":"b19","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1719","DOI":"10.1097\/00007632-199608010-00001","article-title":"Occipital morphology. An anatomic guide to internal fixation","volume":"21","author":"Zipnick RI","year":"1996","unstructured":"Zipnick RI, Merola AA, Gorup J,  Occipital morphology. An anatomic guide to internal fixation. Spine (Phila Pa 1976). 1996;21(15):1719\u20131724, 1729\u20131730.10.1097\/00007632-199608010-00001"},{"issue":"15","key":"b20","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"1725","DOI":"10.1097\/00007632-199608010-00002","article-title":"An anatomic study of the thickness of the occipital bone. Implications for occipitocervical instrumentation","volume":"21","author":"Ebraheim NA","year":"1996","unstructured":"Ebraheim NA, Lu J, Biyani A,  An anatomic study of the thickness of the occipital bone. Implications for occipitocervical instrumentation. Spine (Phila Pa 1976). 1996;21(15):1725\u20131730.10.1097\/00007632-199608010-00002"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/33\/2\/article-p138.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/33\/2\/article-p138.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/33\/2\/article-p138.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,1]],"date-time":"2023-04-01T21:10:54Z","timestamp":1680383454000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/33\/2\/article-p138.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8]]},"references-count":20,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3171\/2020.1.spine191331","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8]]}}}