{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T12:53:37Z","timestamp":1783947217625,"version":"3.55.0"},"reference-count":44,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Providing new tools to improve surgical planning is considered a main goal in meningioma treatment. In this context, two factors are crucial in determining operating strategy: meningioma-brain interface and meningioma consistency. The use of intraoperative ultrasound (ioUS) elastosonography, a real-time imaging technique, has been introduced in general surgery to evaluate similar features in other pathological settings such as thyroid and prostate cancer. The aim of the present study was to evaluate ioUS elastosonography in the intraoperative prediction of key intracranial meningioma features and to evaluate its application in guiding surgical strategy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>An institutional series of 36 meningiomas studied with ioUS elastosonography is reported. Elastographic data, intraoperative surgical findings, and corresponding preoperative MRI features were classified, applying a score from 0 to 2 to both meningioma consistency and meningioma-brain interface. Statistical analysis was performed to determine the degree of agreement between meningioma elastosonographic features and surgical findings, and whether intraoperative elastosonography was a better predictor than preoperative MRI in assessing meningioma consistency and slip-brain interface, using intraoperative findings as the gold standard.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>A significantly high degree of reliability and agreement between ioUS elastographic scores and surgical finding scores was reported (intraclass correlation coefficient = 0.848, F = 12.147, p &lt; 0.001). When analyzing both consistency and brain-tumor interface, ioUS elastography proved to have a rather elevated sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and positive (LR+) and negative likelihood ratio (LR\u2212). This consideration was true especially for meningiomas with a hard consistency (sensitivity = 0.92, specificity = 0.96, PPV = 0.92, NPV = 0.96, LR+ = 22.00, LR\u2212 = 0.09) and for those presenting with an adherent slip-brain interface (sensitivity = 0.76, specificity = 0.95, PPV = 0.93, NPV = 0.82, LR+ = 14.3, LR\u2212 = 0.25). Furthermore, predictions derived from ioUS elastography were found to be more accurate than MRI-derived predictions, as demonstrated by McNemar\u2019s test results in both consistency (p &lt; 0.001) and interface (p &lt; 0.001).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>While external validation of the data is needed to transform ioUS elastography into a fully deployable clinical tool, this experience confirmed that it may be integrated into meningioma surgical planning, especially because of its rapidity and cost-effectiveness.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2020.10.focus20797","type":"journal-article","created":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T11:31:25Z","timestamp":1609500685000},"page":"E15","source":"Crossref","is-referenced-by-count":30,"title":["Predicting meningioma consistency and brain-meningioma interface with intraoperative strain ultrasound elastography: a novel application to guide surgical strategy"],"prefix":"10.3171","volume":"50","author":[{"given":"Giuseppe Maria","family":"Della Pepa","sequence":"first","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grazia","family":"Menna","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vito","family":"Stifano","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angelo Maria","family":"Pezzullo","sequence":"additional","affiliation":[{"name":"Public Health Department, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University, Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Maria","family":"Auricchio","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Rapisarda","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valerio Maria","family":"Caccavella","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"La Rocca","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Sabatino","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enrico","family":"Marchese","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Olivi","sequence":"additional","affiliation":[{"name":"Institute of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"2","key":"b1","series-title":"Neurosurg Clin N Am","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.nec.2015.11.007","article-title":"Predicting meningioma consistency on preoperative neuroimaging studies","volume":"27","author":"Shiroishi MS","year":"2016","unstructured":"Shiroishi MS, Cen SY, Tamrazi B,  Predicting meningioma consistency on preoperative neuroimaging studies. Neurosurg Clin N Am. 2016;27(2):145\u2013154.2701237910.1016\/j.nec.2015.11.007"},{"issue":"4","key":"b2","series-title":"J Magn Reson Imaging","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1002\/jmri.25623","article-title":"Slip interface imaging based on MR-elastography preoperatively predicts meningioma-brain adhesion","volume":"46","author":"Yin Z","year":"2017","unstructured":"Yin Z, Hughes JD, Trzasko JD,  Slip interface imaging based on MR-elastography preoperatively predicts meningioma-brain adhesion. J Magn Reson Imaging. 2017;46(4):1007\u20131016.10.1002\/jmri.2562328194925"},{"issue":"1","key":"b3","series-title":"Neurosurg Rev","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10143-017-0862-8","article-title":"Utility of preoperative meningioma consistency measurement with magnetic resonance elastography (MRE): a review","volume":"42","author":"Chartrain AG","year":"2019","unstructured":"Chartrain AG, Kurt M, Yao A,  Utility of preoperative meningioma consistency measurement with magnetic resonance elastography (MRE): a review. Neurosurg Rev. 2019;42(1):1\u20137.10.1007\/s10143-017-0862-828560608"},{"key":"b4","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e258","DOI":"10.1016\/j.wneu.2019.11.133","article-title":"Intraoperative ultrasonographic elastography: a semi-quantitative analysis of brain tumor elasticity patterns and peritumoral region","volume":"135","author":"Cepeda S","year":"2020","unstructured":"Cepeda S, Barrena C, Arrese I,  Intraoperative ultrasonographic elastography: a semi-quantitative analysis of brain tumor elasticity patterns and peritumoral region. World Neurosurg. 2020;135:e258\u2013e270.3179084310.1016\/j.wneu.2019.11.133"},{"key":"b5","series-title":"J Ultrasound Med","doi-asserted-by":"publisher","first-page":"985","DOI":"10.7863\/jum.2005.24.7.985","article-title":"Vibrography during tumor neurosurgery","author":"Scholz M","year":"2005","unstructured":"Scholz M, Noack V, Pechlivanis I,  Vibrography during tumor neurosurgery. J Ultrasound Med. 2005:985\u2013992.10.7863\/jum.2005.24.7.98515972713"},{"issue":"4","key":"b6","series-title":"Ultrasound Int Open","doi-asserted-by":"publisher","first-page":"E137","DOI":"10.1055\/s-0043-119412","article-title":"Strain elastography\u2014How to do it?","volume":"3","author":"Dietrich CF","year":"2017","unstructured":"Dietrich CF, Barr RG, Farrokh A,  Strain elastography\u2014How to do it? Ultrasound Int Open. 2017;3(4):E137\u2013E149.10.1055\/s-0043-119412"},{"key":"b7","series-title":"Neuroimage","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/j.neuroimage.2017.10.008","article-title":"MR elastography of the brain and its application in neurological diseases","volume":"187","author":"Murphy MC","year":"2019","unstructured":"Murphy MC, Huston J III, Ehman RL. MR elastography of the brain and its application in neurological diseases. Neuroimage. 2019;187:176\u2013183.2899323210.1016\/j.neuroimage.2017.10.008"},{"issue":"5","key":"b8","series-title":"Top Magn Reson Imaging","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1097\/RMR.0000000000000178","article-title":"Stiffness and beyond: what MR elastography can tell us about brain structure and function under physiologic and pathologic conditions","volume":"27","author":"Yin Z","year":"2018","unstructured":"Yin Z, Romano AJ, Manduca A,  Stiffness and beyond: what MR elastography can tell us about brain structure and function under physiologic and pathologic conditions. Top Magn Reson Imaging. 2018;27(5):305\u2013318.10.1097\/RMR.000000000000017830289827"},{"issue":"2","key":"b9","series-title":"Eur Radiol","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1007\/s00330-019-06436-w","article-title":"Automated multiparametric localization of prostate cancer based on B-mode, shear-wave elastography, and contrast-enhanced ultrasound radiomics","volume":"30","author":"Wildeboer RR","year":"2020","unstructured":"Wildeboer RR, Mannaerts CK, van Sloun RJG,  Automated multiparametric localization of prostate cancer based on B-mode, shear-wave elastography, and contrast-enhanced ultrasound radiomics. Eur Radiol. 2020;30(2):806\u2013815.3160251210.1007\/s00330-019-06436-w"},{"issue":"2","key":"b10","series-title":"Ultrasonography","doi-asserted-by":"publisher","first-page":"106","DOI":"10.14366\/usg.18037","article-title":"Ultrasound elastography of the thyroid: principles and current status","volume":"38","author":"Zhao C-K","year":"2019","unstructured":"Zhao C-K, Xu H-X. Ultrasound elastography of the thyroid: principles and current status. Ultrasonography. 2019;38(2):106\u2013124.3069096010.14366\/usg.18037"},{"issue":"10","key":"b11","series-title":"Ultrasound Med Biol","doi-asserted-by":"publisher","first-page":"2612","DOI":"10.1016\/j.ultrasmedbio.2019.06.421","article-title":"Conventional US and 2-D shear wave elastography of virtual touch tissue imaging quantification: correlation with immunohistochemical subtypes of breast cancer","volume":"45","author":"Liu H","year":"2019","unstructured":"Liu H, Wan J, Xu G,  Conventional US and 2-D shear wave elastography of virtual touch tissue imaging quantification: correlation with immunohistochemical subtypes of breast cancer. Ultrasound Med Biol. 2019;45(10):2612\u20132622.10.1016\/j.ultrasmedbio.2019.06.42131371128"},{"issue":"2","key":"b12","series-title":"J Ultrasound Med","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1002\/jum.14920","article-title":"Bowel ultrasound state of the art: grayscale and Doppler ultrasound, contrast enhancement, and elastography in Crohn disease","volume":"38","author":"Lu C","year":"2019","unstructured":"Lu C, Merrill C, Medellin A,  Bowel ultrasound state of the art: grayscale and Doppler ultrasound, contrast enhancement, and elastography in Crohn disease. J Ultrasound Med. 2019;38(2):271\u2013288.10.1002\/jum.1492030604884"},{"issue":"14","key":"b13","series-title":"World J Gastroenterol","doi-asserted-by":"publisher","first-page":"3712","DOI":"10.3748\/wjg.v22.i14.3712","article-title":"Elastography for the pancreas: current status and future perspective","volume":"22","author":"Kawada N","year":"2016","unstructured":"Kawada N, Tanaka S. Elastography for the pancreas: current status and future perspective. World J Gastroenterol. 2016;22(14):3712\u20133724.2707675610.3748\/wjg.v22.i14.3712"},{"issue":"6","key":"b14","series-title":"Ultraschall Med","first-page":"584","article-title":"In vivo measurement of brain tumor elasticity using intraoperative shear wave elastography","volume":"37","author":"Chauvet D","year":"2016","unstructured":"Chauvet D, Imbault M, Capelle L,  In vivo measurement of brain tumor elasticity using intraoperative shear wave elastography. Ultraschall Med. 2016;37(6):584\u2013590.25876221"},{"issue":"2","key":"b15","series-title":"Oper Neurosurg (Hagerstown)","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1093\/ons\/opy323","article-title":"Intraoperative strain elastosonography in brain tumor surgery","volume":"17","author":"Prada F","year":"2019","unstructured":"Prada F, Del Bene M, Rampini A,  Intraoperative strain elastosonography in brain tumor surgery. Oper Neurosurg (Hagerstown). 2019;17(2):227\u2013236.10.1093\/ons\/opy323"},{"issue":"3","key":"b16","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E2","DOI":"10.3171\/2015.12.FOCUS15582","article-title":"Ultrasound-guided neurosurgery: experiences from 20 years of cross-disciplinary research in Trondheim, Norway","volume":"40","author":"Selbekk T","year":"2016","unstructured":"Selbekk T, Solheim O, Unsg\u00e5rd G. Ultrasound-guided neurosurgery: experiences from 20 years of cross-disciplinary research in Trondheim, Norway. Neurosurg Focus. 2016;40(3):E2.2692606010.3171\/2015.12.FOCUS15582"},{"issue":"1","key":"b17","series-title":"Ultrasound Med Biol","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.ultrasmedbio.2009.05.007","article-title":"Tissue motion and strain in the human brain assessed by intraoperative ultrasound in glioma patients","volume":"36","author":"Selbekk T","year":"2010","unstructured":"Selbekk T, Brekken R, Solheim O,  Tissue motion and strain in the human brain assessed by intraoperative ultrasound in glioma patients. Ultrasound Med Biol. 2010;36(1):2\u201310.10.1016\/j.ultrasmedbio.2009.05.00719854562"},{"key":"b18","series-title":"Presented at the 2009 IEEE International Ultrasonics Symposium; September 20\u201323, 2009","article-title":"Real-time ultrasound elastography in neurosurgery","author":"Uff CE","unstructured":"Uff CE, Garcia L, Fromageau J,  Real-time ultrasound elastography in neurosurgery. Presented at the 2009 IEEE International Ultrasonics Symposium; September 20\u201323, 2009; Rome, Italy."},{"key":"b19","series-title":"BioMed Res Int","doi-asserted-by":"publisher","first-page":"925729","DOI":"10.1155\/2015\/925729","article-title":"From grey scale B-mode to elastosonography: multimodal ultrasound imaging in meningioma surgery\u2014pictorial essay and literature review","volume":"2015","author":"Prada F","year":"2015","unstructured":"Prada F, Del Bene M, Moiraghi A,  From grey scale B-mode to elastosonography: multimodal ultrasound imaging in meningioma surgery\u2014pictorial essay and literature review. BioMed Res Int. 2015;2015:925729.2610177910.1155\/2015\/925729"},{"key":"b20","series-title":"Clin Neurol Neurosurg","doi-asserted-by":"publisher","first-page":"106105","DOI":"10.1016\/j.clineuro.2020.106105","article-title":"Contrast enhanced ultrasound (CEUS) applications in neurosurgical and neurological settings\u2014New scenarios for brain and spinal cord ultrasonography. A systematic review","volume":"198","author":"Della Pepa GM","year":"2020","unstructured":"Della Pepa GM, Menna G, Ius T,  Contrast enhanced ultrasound (CEUS) applications in neurosurgical and neurological settings\u2014New scenarios for brain and spinal cord ultrasonography. A systematic review. Clin Neurol Neurosurg. 2020;198:106105.10.1016\/j.clineuro.2020.106105"},{"issue":"6","key":"b21","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"E529","DOI":"10.1093\/neuros\/nyaa037","article-title":"5-Aminolevulinic acid and contrast-enhanced ultrasound: the combination of the two techniques to optimize the extent of resection in glioblastoma surgery","volume":"86","author":"Della Pepa GM","year":"2020","unstructured":"Della Pepa GM, Ius T, La Rocca G,  5-Aminolevulinic acid and contrast-enhanced ultrasound: the combination of the two techniques to optimize the extent of resection in glioblastoma surgery. Neurosurgery. 2020;86(6):E529\u2013E540.10.1093\/neuros\/nyaa03732186345"},{"key":"b22","series-title":"Optimising the Use and Assessing the Value of Intraoperative Shear Wave Elastography in Neurosurgery [doctoral thesis]","author":"Chan HW","year":"2016","unstructured":"Chan HW. Optimising the Use and Assessing the Value of Intraoperative Shear Wave Elastography in Neurosurgery [doctoral thesis]. London: University College London; 2016."},{"issue":"2","key":"b1","series-title":"Neurosurg Clin N Am","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.nec.2015.11.007","article-title":"Predicting meningioma consistency on preoperative neuroimaging studies","volume":"27","author":"Shiroishi MS","year":"2016","unstructured":"Shiroishi MS, Cen SY, Tamrazi B,  Predicting meningioma consistency on preoperative neuroimaging studies. Neurosurg Clin N Am. 2016;27(2):145\u2013154.2701237910.1016\/j.nec.2015.11.007"},{"issue":"4","key":"b2","series-title":"J Magn Reson Imaging","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1002\/jmri.25623","article-title":"Slip interface imaging based on MR-elastography preoperatively predicts meningioma-brain adhesion","volume":"46","author":"Yin Z","year":"2017","unstructured":"Yin Z, Hughes JD, Trzasko JD,  Slip interface imaging based on MR-elastography preoperatively predicts meningioma-brain adhesion. J Magn Reson Imaging. 2017;46(4):1007\u20131016.10.1002\/jmri.2562328194925"},{"issue":"1","key":"b3","series-title":"Neurosurg Rev","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10143-017-0862-8","article-title":"Utility of preoperative meningioma consistency measurement with magnetic resonance elastography (MRE): a review","volume":"42","author":"Chartrain AG","year":"2019","unstructured":"Chartrain AG, Kurt M, Yao A,  Utility of preoperative meningioma consistency measurement with magnetic resonance elastography (MRE): a review. Neurosurg Rev. 2019;42(1):1\u20137.10.1007\/s10143-017-0862-828560608"},{"key":"b4","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e258","DOI":"10.1016\/j.wneu.2019.11.133","article-title":"Intraoperative ultrasonographic elastography: a semi-quantitative analysis of brain tumor elasticity patterns and peritumoral region","volume":"135","author":"Cepeda S","year":"2020","unstructured":"Cepeda S, Barrena C, Arrese I,  Intraoperative ultrasonographic elastography: a semi-quantitative analysis of brain tumor elasticity patterns and peritumoral region. World Neurosurg. 2020;135:e258\u2013e270.3179084310.1016\/j.wneu.2019.11.133"},{"key":"b5","series-title":"J Ultrasound Med","doi-asserted-by":"publisher","first-page":"985","DOI":"10.7863\/jum.2005.24.7.985","article-title":"Vibrography during tumor neurosurgery","author":"Scholz M","year":"2005","unstructured":"Scholz M, Noack V, Pechlivanis I,  Vibrography during tumor neurosurgery. J Ultrasound Med. 2005:985\u2013992.10.7863\/jum.2005.24.7.98515972713"},{"issue":"4","key":"b6","series-title":"Ultrasound Int Open","doi-asserted-by":"publisher","first-page":"E137","DOI":"10.1055\/s-0043-119412","article-title":"Strain elastography\u2014How to do it?","volume":"3","author":"Dietrich CF","year":"2017","unstructured":"Dietrich CF, Barr RG, Farrokh A,  Strain elastography\u2014How to do it? Ultrasound Int Open. 2017;3(4):E137\u2013E149.10.1055\/s-0043-119412"},{"key":"b7","series-title":"Neuroimage","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/j.neuroimage.2017.10.008","article-title":"MR elastography of the brain and its application in neurological diseases","volume":"187","author":"Murphy MC","year":"2019","unstructured":"Murphy MC, Huston J III, Ehman RL. MR elastography of the brain and its application in neurological diseases. Neuroimage. 2019;187:176\u2013183.2899323210.1016\/j.neuroimage.2017.10.008"},{"issue":"5","key":"b8","series-title":"Top Magn Reson Imaging","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1097\/RMR.0000000000000178","article-title":"Stiffness and beyond: what MR elastography can tell us about brain structure and function under physiologic and pathologic conditions","volume":"27","author":"Yin Z","year":"2018","unstructured":"Yin Z, Romano AJ, Manduca A,  Stiffness and beyond: what MR elastography can tell us about brain structure and function under physiologic and pathologic conditions. Top Magn Reson Imaging. 2018;27(5):305\u2013318.10.1097\/RMR.000000000000017830289827"},{"issue":"2","key":"b9","series-title":"Eur Radiol","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1007\/s00330-019-06436-w","article-title":"Automated multiparametric localization of prostate cancer based on B-mode, shear-wave elastography, and contrast-enhanced ultrasound radiomics","volume":"30","author":"Wildeboer RR","year":"2020","unstructured":"Wildeboer RR, Mannaerts CK, van Sloun RJG,  Automated multiparametric localization of prostate cancer based on B-mode, shear-wave elastography, and contrast-enhanced ultrasound radiomics. Eur Radiol. 2020;30(2):806\u2013815.3160251210.1007\/s00330-019-06436-w"},{"issue":"2","key":"b10","series-title":"Ultrasonography","doi-asserted-by":"publisher","first-page":"106","DOI":"10.14366\/usg.18037","article-title":"Ultrasound elastography of the thyroid: principles and current status","volume":"38","author":"Zhao C-K","year":"2019","unstructured":"Zhao C-K, Xu H-X. Ultrasound elastography of the thyroid: principles and current status. Ultrasonography. 2019;38(2):106\u2013124.3069096010.14366\/usg.18037"},{"issue":"10","key":"b11","series-title":"Ultrasound Med Biol","doi-asserted-by":"publisher","first-page":"2612","DOI":"10.1016\/j.ultrasmedbio.2019.06.421","article-title":"Conventional US and 2-D shear wave elastography of virtual touch tissue imaging quantification: correlation with immunohistochemical subtypes of breast cancer","volume":"45","author":"Liu H","year":"2019","unstructured":"Liu H, Wan J, Xu G,  Conventional US and 2-D shear wave elastography of virtual touch tissue imaging quantification: correlation with immunohistochemical subtypes of breast cancer. Ultrasound Med Biol. 2019;45(10):2612\u20132622.10.1016\/j.ultrasmedbio.2019.06.42131371128"},{"issue":"2","key":"b12","series-title":"J Ultrasound Med","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1002\/jum.14920","article-title":"Bowel ultrasound state of the art: grayscale and Doppler ultrasound, contrast enhancement, and elastography in Crohn disease","volume":"38","author":"Lu C","year":"2019","unstructured":"Lu C, Merrill C, Medellin A,  Bowel ultrasound state of the art: grayscale and Doppler ultrasound, contrast enhancement, and elastography in Crohn disease. J Ultrasound Med. 2019;38(2):271\u2013288.10.1002\/jum.1492030604884"},{"issue":"14","key":"b13","series-title":"World J Gastroenterol","doi-asserted-by":"publisher","first-page":"3712","DOI":"10.3748\/wjg.v22.i14.3712","article-title":"Elastography for the pancreas: current status and future perspective","volume":"22","author":"Kawada N","year":"2016","unstructured":"Kawada N, Tanaka S. Elastography for the pancreas: current status and future perspective. World J Gastroenterol. 2016;22(14):3712\u20133724.2707675610.3748\/wjg.v22.i14.3712"},{"issue":"6","key":"b14","series-title":"Ultraschall Med","first-page":"584","article-title":"In vivo measurement of brain tumor elasticity using intraoperative shear wave elastography","volume":"37","author":"Chauvet D","year":"2016","unstructured":"Chauvet D, Imbault M, Capelle L,  In vivo measurement of brain tumor elasticity using intraoperative shear wave elastography. Ultraschall Med. 2016;37(6):584\u2013590.25876221"},{"issue":"2","key":"b15","series-title":"Oper Neurosurg (Hagerstown)","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1093\/ons\/opy323","article-title":"Intraoperative strain elastosonography in brain tumor surgery","volume":"17","author":"Prada F","year":"2019","unstructured":"Prada F, Del Bene M, Rampini A,  Intraoperative strain elastosonography in brain tumor surgery. Oper Neurosurg (Hagerstown). 2019;17(2):227\u2013236.10.1093\/ons\/opy323"},{"issue":"3","key":"b16","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E2","DOI":"10.3171\/2015.12.FOCUS15582","article-title":"Ultrasound-guided neurosurgery: experiences from 20 years of cross-disciplinary research in Trondheim, Norway","volume":"40","author":"Selbekk T","year":"2016","unstructured":"Selbekk T, Solheim O, Unsg\u00e5rd G. Ultrasound-guided neurosurgery: experiences from 20 years of cross-disciplinary research in Trondheim, Norway. Neurosurg Focus. 2016;40(3):E2.2692606010.3171\/2015.12.FOCUS15582"},{"issue":"1","key":"b17","series-title":"Ultrasound Med Biol","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.ultrasmedbio.2009.05.007","article-title":"Tissue motion and strain in the human brain assessed by intraoperative ultrasound in glioma patients","volume":"36","author":"Selbekk T","year":"2010","unstructured":"Selbekk T, Brekken R, Solheim O,  Tissue motion and strain in the human brain assessed by intraoperative ultrasound in glioma patients. Ultrasound Med Biol. 2010;36(1):2\u201310.10.1016\/j.ultrasmedbio.2009.05.00719854562"},{"key":"b18","series-title":"Presented at the 2009 IEEE International Ultrasonics Symposium; September 20\u201323, 2009","article-title":"Real-time ultrasound elastography in neurosurgery","author":"Uff CE","unstructured":"Uff CE, Garcia L, Fromageau J,  Real-time ultrasound elastography in neurosurgery. Presented at the 2009 IEEE International Ultrasonics Symposium; September 20\u201323, 2009; Rome, Italy."},{"key":"b19","series-title":"BioMed Res Int","doi-asserted-by":"publisher","first-page":"925729","DOI":"10.1155\/2015\/925729","article-title":"From grey scale B-mode to elastosonography: multimodal ultrasound imaging in meningioma surgery\u2014pictorial essay and literature review","volume":"2015","author":"Prada F","year":"2015","unstructured":"Prada F, Del Bene M, Moiraghi A,  From grey scale B-mode to elastosonography: multimodal ultrasound imaging in meningioma surgery\u2014pictorial essay and literature review. BioMed Res Int. 2015;2015:925729.2610177910.1155\/2015\/925729"},{"key":"b20","series-title":"Clin Neurol Neurosurg","doi-asserted-by":"publisher","first-page":"106105","DOI":"10.1016\/j.clineuro.2020.106105","article-title":"Contrast enhanced ultrasound (CEUS) applications in neurosurgical and neurological settings\u2014New scenarios for brain and spinal cord ultrasonography. A systematic review","volume":"198","author":"Della Pepa GM","year":"2020","unstructured":"Della Pepa GM, Menna G, Ius T,  Contrast enhanced ultrasound (CEUS) applications in neurosurgical and neurological settings\u2014New scenarios for brain and spinal cord ultrasonography. A systematic review. Clin Neurol Neurosurg. 2020;198:106105.10.1016\/j.clineuro.2020.106105"},{"issue":"6","key":"b21","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"E529","DOI":"10.1093\/neuros\/nyaa037","article-title":"5-Aminolevulinic acid and contrast-enhanced ultrasound: the combination of the two techniques to optimize the extent of resection in glioblastoma surgery","volume":"86","author":"Della Pepa GM","year":"2020","unstructured":"Della Pepa GM, Ius T, La Rocca G,  5-Aminolevulinic acid and contrast-enhanced ultrasound: the combination of the two techniques to optimize the extent of resection in glioblastoma surgery. Neurosurgery. 2020;86(6):E529\u2013E540.10.1093\/neuros\/nyaa03732186345"},{"key":"b22","series-title":"Optimising the Use and Assessing the Value of Intraoperative Shear Wave Elastography in Neurosurgery [doctoral thesis]","author":"Chan HW","year":"2016","unstructured":"Chan HW. Optimising the Use and Assessing the Value of Intraoperative Shear Wave Elastography in Neurosurgery [doctoral thesis]. London: University College London; 2016."}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/50\/1\/article-pE15.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/50\/1\/article-pE15.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/50\/1\/article-pE15.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T08:22:21Z","timestamp":1779524541000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/50\/1\/article-pE15.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":44,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3171\/2020.10.focus20797","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}