{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T11:13:32Z","timestamp":1787829212627,"version":"build-2784847793"},"reference-count":40,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Lateral lumbar interbody fusion (LLIF) is a useful minimally invasive technique for achieving anterior interbody fusion and preserving or restoring lumbar lordosis. However, achieving circumferential fusion via posterior instrumentation after an LLIF can be challenging, requiring either repositioning the patient or placing pedicle screws in the lateral position. Here, the authors explore an alternative single-position approach: LLIF in the prone lateral (PL) position.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>A cadaveric feasibility study was performed using 2 human cadaveric specimens. A retrospective 2-center early clinical series was performed for patients who had undergone a minimally invasive lateral procedure in the prone position between August 2019 and March 2020. Case duration, retractor time, electrophysiological thresholds, implant size, screw accuracy, and complications were recorded. Early postoperative radiographic outcomes were reported.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>A PL LLIF was successfully performed in 2 cadavers without causing injury to a vessel or the bowel. No intraoperative subsidence was observed. In the clinical series, 12 patients underwent attempted PL surgery, although 1 case was converted to standard lateral positioning. Thus, 11 patients successfully underwent PL LLIF (89%) across 14 levels: L2\u20133 (2 of 14 [14%]), L3\u20134 (6 of 14 [43%]), and L4\u20135 (6 of 14 [43%]). For the 11 PL patients, the mean (\u00b1 SD) age was 61 \u00b1 16 years, mean BMI was 25.8 \u00b1 4.8, and mean retractor time per level was 15 \u00b1 6 minutes with the longest retractor time at L2\u20133 and the shortest at L4\u20135. No intraoperative subsidence was noted on routine postoperative imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>Performing single-position lateral transpsoas interbody fusion with the patient prone is anatomically feasible, and in an early clinical experience, it appeared safe and reproducible. Prone positioning for a lateral approach presents an exciting opportunity for streamlining surgical access to the lumbar spine and facilitating more efficient surgical solutions with potential clinical and economic advantages.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2020.6.focus20359","type":"journal-article","created":{"date-parts":[[2020,9,1]],"date-time":"2020-09-01T06:32:03Z","timestamp":1598941923000},"page":"E15","source":"Crossref","is-referenced-by-count":56,"title":["Single-position prone lateral approach: cadaveric feasibility study and early clinical experience"],"prefix":"10.3171","volume":"49","author":[{"given":"Jakub","family":"Godzik","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ifije E.","family":"Ohiorhenuan","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David S.","family":"Xu","sequence":"additional","affiliation":[{"name":"Neurosurgery Department, Houston Methodist Hospital, Houston, Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernardo","family":"de Andrada Pereira","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Corey T.","family":"Walker","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander C.","family":"Whiting","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay D.","family":"Turner","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan S.","family":"Uribe","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Barrow Neurological Institute, St. Joseph\u2019s Hospital and Medical Center, Phoenix, Arizona; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"24","key":"b1","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E1461","DOI":"10.1097\/BRS.0000000000003191","article-title":"Comparison of stand-alone lateral lumbar interbody fusion versus open laminectomy and posterolateral instrumented fusion in the treatment of adjacent segment disease following previous lumbar fusion surgery","volume":"44","author":"Louie PK","year":"2019","unstructured":"Louie PK, Haws BE, Khan JM,  Comparison of stand-alone lateral lumbar interbody fusion versus open laminectomy and posterolateral instrumented fusion in the treatment of adjacent segment disease following previous lumbar fusion surgery. Spine (Phila Pa 1976). 2019;44(24):E1461\u2013E1469.10.1097\/BRS.0000000000003191"},{"issue":"6","key":"b2","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"994","DOI":"10.3171\/2014.9.SPINE131176","article-title":"Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity","volume":"21","author":"Smith JS","year":"2014","unstructured":"Smith JS, Shaffrey E, Klineberg E,  Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity. J Neurosurg Spine. 2014;21(6):994\u20131003.2532517510.3171\/2014.9.SPINE131176"},{"key":"b3","series-title":"ScientificWorldJournal","doi-asserted-by":"publisher","first-page":"381814","DOI":"10.1100\/2012\/381814","article-title":"Biomechanics of lateral interbody spacers: going wider for going stiffer","volume":"2012","author":"Pimenta L","year":"2012","unstructured":"Pimenta L, Turner AW, Dooley ZA,  Biomechanics of lateral interbody spacers: going wider for going stiffer. ScientificWorldJournal. 2012;2012:381814.10.1100\/2012\/38181423213284"},{"key":"b4","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e439","DOI":"10.1016\/j.wneu.2018.02.053","article-title":"Biomechanical stability afforded by unilateral versus bilateral pedicle screw fixation with and without interbody support using lateral lumbar interbody fusion","volume":"113","author":"Godzik J","year":"2018","unstructured":"Godzik J, Martinez-Del-Campo E, Newcomb AGUS,  Biomechanical stability afforded by unilateral versus bilateral pedicle screw fixation with and without interbody support using lateral lumbar interbody fusion. World Neurosurg. 2018;113:e439\u2013e445.10.1016\/j.wneu.2018.02.05329462730"},{"issue":"1","key":"b5","series-title":"J Orthop Surg Res","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-019-1354-z","article-title":"The analysis of percutaneous pedicle screw technique with guide wire-less in lateral decubitus position following extreme lateral interbody fusion","volume":"14","author":"Hiyama A","year":"2019","unstructured":"Hiyama A, Sakai D, Sato M, Watanabe M. The analysis of percutaneous pedicle screw technique with guide wire-less in lateral decubitus position following extreme lateral interbody fusion. J Orthop Surg Res. 2019;14(1):304.3148818110.1186\/s13018-019-1354-z"},{"key":"b6","series-title":"J Clin Neurosci","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.jocn.2019.03.016","article-title":"Single position spinal surgery for the treatment of grade II spondylolisthesis: a technical note","volume":"65","author":"Quiceno E","year":"2019","unstructured":"Quiceno E, Hartman C, Godzik J,  Single position spinal surgery for the treatment of grade II spondylolisthesis: a technical note. J Clin Neurosci. 2019;65:145\u2013147.3104003410.1016\/j.jocn.2019.03.016"},{"issue":"6","key":"b7","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1097\/BRS.0000000000002330","article-title":"MIS single-position lateral and oblique lateral lumbar interbody fusion and bilateral pedicle screw fixation: feasibility and perioperative results","volume":"43","author":"Blizzard DJ","year":"2018","unstructured":"Blizzard DJ, Thomas JA. MIS single-position lateral and oblique lateral lumbar interbody fusion and bilateral pedicle screw fixation: feasibility and perioperative results. Spine (Phila Pa 1976). 2018;43(6):440\u2013446.10.1097\/BRS.0000000000002330"},{"key":"b8","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e647","DOI":"10.1016\/j.wneu.2018.09.180","article-title":"Lateral lumbar interbody fusion revisited: complication avoidance and outcomes with the mini-open approach","volume":"121","author":"Sellin JN","year":"2019","unstructured":"Sellin JN, Brusko GD, Levi AD. Lateral lumbar interbody fusion revisited: complication avoidance and outcomes with the mini-open approach. World Neurosurg. 2019;121:e647\u2013e653.3029203010.1016\/j.wneu.2018.09.180"},{"issue":"1","key":"b9","series-title":"BMC Musculoskelet Disord","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1186\/s12891-019-2992-3","article-title":"Comparison of radiological changes after single- position versus dual- position for lateral interbody fusion and pedicle screw fixation","volume":"20","author":"Hiyama A","year":"2019","unstructured":"Hiyama A, Katoh H, Sakai D,  Comparison of radiological changes after single- position versus dual- position for lateral interbody fusion and pedicle screw fixation. BMC Musculoskelet Disord. 2019;20(1):601.10.1186\/s12891-019-2992-331830959"},{"issue":"2","key":"b10","series-title":"J Spine Surg","doi-asserted-by":"publisher","first-page":"201","DOI":"10.21037\/jss.2019.05.09","article-title":"Analysis of single-position for revision surgery using lateral interbody fusion and pedicle screw fixation: feasibility and perioperative results","volume":"5","author":"Ziino C","year":"2019","unstructured":"Ziino C, Arzeno A, Cheng I. Analysis of single-position for revision surgery using lateral interbody fusion and pedicle screw fixation: feasibility and perioperative results. J Spine Surg. 2019;5(2):201\u2013206.3138047310.21037\/jss.2019.05.09"},{"issue":"6","key":"b11","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1007\/s00586-020-06388-6","article-title":"Simultaneous single-position lateral interbody fusion and percutaneous pedicle screw fixation using O-arm-based navigation reduces the occupancy time of the operating room","volume":"29","author":"Ouchida J","year":"2020","unstructured":"Ouchida J, Kanemura T, Satake K,  Simultaneous single-position lateral interbody fusion and percutaneous pedicle screw fixation using O-arm-based navigation reduces the occupancy time of the operating room. Eur Spine J. 2020;29(6):1277\u20131286.3223935510.1007\/s00586-020-06388-6"},{"issue":"suppl 8","key":"b12","series-title":"Spine (Phila Pa 1976)","first-page":"S152","article-title":"Procedural checklist for retroperitoneal transpsoas minimally invasive lateral interbody fusion","volume":"41","author":"Yen CP","year":"2016","unstructured":"Yen CP, Uribe JS. Procedural checklist for retroperitoneal transpsoas minimally invasive lateral interbody fusion. Spine (Phila Pa 1976). 2016;41(suppl 8):S152\u2013S158."},{"issue":"4","key":"b13","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.spinee.2005.08.012","article-title":"Extreme Lateral Interbody Fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion","volume":"6","author":"Ozgur BM","year":"2006","unstructured":"Ozgur BM, Aryan HE, Pimenta L, Taylor WR. Extreme Lateral Interbody Fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion. Spine J. 2006;6(4):435\u2013443.1682505210.1016\/j.spinee.2005.08.012"},{"issue":"suppl 2","key":"b14","series-title":"Neurosurgery","first-page":"259","article-title":"Three-dimensional computed tomography-based spinal navigation in minimally invasive lateral lumbar interbody fusion: feasibility, technique, and initial results","volume":"11","author":"Park P","year":"2015","unstructured":"Park P. Three-dimensional computed tomography-based spinal navigation in minimally invasive lateral lumbar interbody fusion: feasibility, technique, and initial results. Neurosurgery. 2015;11(suppl 2):259\u2013267.25812070"},{"issue":"2","key":"b15","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"260","DOI":"10.3171\/2010.3.SPINE09766","article-title":"Defining the safe working zones using the minimally invasive lateral retroperitoneal transpsoas approach: an anatomical study","volume":"13","author":"Uribe JS","year":"2010","unstructured":"Uribe JS, Arredondo N, Dakwar E, Vale FL. Defining the safe working zones using the minimally invasive lateral retroperitoneal transpsoas approach: an anatomical study. J Neurosurg Spine. 2010;13(2):260\u2013266.2067296410.3171\/2010.3.SPINE09766"},{"issue":"26","key":"b16","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S368","DOI":"10.1097\/BRS.0b013e3182027976","article-title":"Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery","volume":"35","author":"Uribe JS","year":"2010","unstructured":"Uribe JS, Vale FL, Dakwar E. Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery. Spine (Phila Pa 1976). 2010;35(26)(suppl):S368\u2013S374.10.1097\/BRS.0b013e3182027976"},{"key":"b17","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e208","DOI":"10.1016\/j.wneu.2020.01.134","article-title":"Timing of lateral lumbar interbody subsidence: a review of exclusive intraoperative subsidence","volume":"137","author":"Wewel JT","year":"2020","unstructured":"Wewel JT, Hartman C, Uribe JS. Timing of lateral lumbar interbody subsidence: a review of exclusive intraoperative subsidence. World Neurosurg. 2020;137:e208\u2013e212.10.1016\/j.wneu.2020.01.13431996333"},{"issue":"3","key":"b18","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","DOI":"10.3171\/2014.1.FOCUS13531","article-title":"Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation","volume":"36","author":"Kim TT","year":"2014","unstructured":"Kim TT, Drazin D, Shweikeh F,  Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation. Neurosurg Focus. 2014;36(3):E10.10.3171\/2014.1.FOCUS1353124580001"},{"issue":"4","key":"b19","series-title":"J Spine Surg","doi-asserted-by":"publisher","first-page":"717","DOI":"10.21037\/jss.2018.12.03","article-title":"Single position versus lateral-then-prone positioning for lateral interbody fusion and pedicle screw fixation","volume":"4","author":"Ziino C","year":"2018","unstructured":"Ziino C, Konopka JA, Ajiboye RM,  Single position versus lateral-then-prone positioning for lateral interbody fusion and pedicle screw fixation. J Spine Surg. 2018;4(4):717\u2013724.3071400310.21037\/jss.2018.12.03"},{"issue":"1","key":"b20","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1007\/s00586-020-06303-z","article-title":"Prone single-position extreme lateral interbody fusion (Pro-XLIF): preliminary results","volume":"29","author":"Lamartina C","year":"2020","unstructured":"Lamartina C, Berjano P. Prone single-position extreme lateral interbody fusion (Pro-XLIF): preliminary results. Eur Spine J. 2020;29(1)(suppl 1):6\u201313.3199378910.1007\/s00586-020-06303-z"},{"issue":"24","key":"b1","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E1461","DOI":"10.1097\/BRS.0000000000003191","article-title":"Comparison of stand-alone lateral lumbar interbody fusion versus open laminectomy and posterolateral instrumented fusion in the treatment of adjacent segment disease following previous lumbar fusion surgery","volume":"44","author":"Louie PK","year":"2019","unstructured":"Louie PK, Haws BE, Khan JM,  Comparison of stand-alone lateral lumbar interbody fusion versus open laminectomy and posterolateral instrumented fusion in the treatment of adjacent segment disease following previous lumbar fusion surgery. Spine (Phila Pa 1976). 2019;44(24):E1461\u2013E1469.10.1097\/BRS.0000000000003191"},{"issue":"6","key":"b2","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"994","DOI":"10.3171\/2014.9.SPINE131176","article-title":"Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity","volume":"21","author":"Smith JS","year":"2014","unstructured":"Smith JS, Shaffrey E, Klineberg E,  Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity. J Neurosurg Spine. 2014;21(6):994\u20131003.2532517510.3171\/2014.9.SPINE131176"},{"key":"b3","series-title":"ScientificWorldJournal","doi-asserted-by":"publisher","first-page":"381814","DOI":"10.1100\/2012\/381814","article-title":"Biomechanics of lateral interbody spacers: going wider for going stiffer","volume":"2012","author":"Pimenta L","year":"2012","unstructured":"Pimenta L, Turner AW, Dooley ZA,  Biomechanics of lateral interbody spacers: going wider for going stiffer. ScientificWorldJournal. 2012;2012:381814.10.1100\/2012\/38181423213284"},{"key":"b4","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e439","DOI":"10.1016\/j.wneu.2018.02.053","article-title":"Biomechanical stability afforded by unilateral versus bilateral pedicle screw fixation with and without interbody support using lateral lumbar interbody fusion","volume":"113","author":"Godzik J","year":"2018","unstructured":"Godzik J, Martinez-Del-Campo E, Newcomb AGUS,  Biomechanical stability afforded by unilateral versus bilateral pedicle screw fixation with and without interbody support using lateral lumbar interbody fusion. World Neurosurg. 2018;113:e439\u2013e445.10.1016\/j.wneu.2018.02.05329462730"},{"issue":"1","key":"b5","series-title":"J Orthop Surg Res","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-019-1354-z","article-title":"The analysis of percutaneous pedicle screw technique with guide wire-less in lateral decubitus position following extreme lateral interbody fusion","volume":"14","author":"Hiyama A","year":"2019","unstructured":"Hiyama A, Sakai D, Sato M, Watanabe M. The analysis of percutaneous pedicle screw technique with guide wire-less in lateral decubitus position following extreme lateral interbody fusion. J Orthop Surg Res. 2019;14(1):304.3148818110.1186\/s13018-019-1354-z"},{"key":"b6","series-title":"J Clin Neurosci","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.jocn.2019.03.016","article-title":"Single position spinal surgery for the treatment of grade II spondylolisthesis: a technical note","volume":"65","author":"Quiceno E","year":"2019","unstructured":"Quiceno E, Hartman C, Godzik J,  Single position spinal surgery for the treatment of grade II spondylolisthesis: a technical note. J Clin Neurosci. 2019;65:145\u2013147.3104003410.1016\/j.jocn.2019.03.016"},{"issue":"6","key":"b7","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1097\/BRS.0000000000002330","article-title":"MIS single-position lateral and oblique lateral lumbar interbody fusion and bilateral pedicle screw fixation: feasibility and perioperative results","volume":"43","author":"Blizzard DJ","year":"2018","unstructured":"Blizzard DJ, Thomas JA. MIS single-position lateral and oblique lateral lumbar interbody fusion and bilateral pedicle screw fixation: feasibility and perioperative results. Spine (Phila Pa 1976). 2018;43(6):440\u2013446.10.1097\/BRS.0000000000002330"},{"key":"b8","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e647","DOI":"10.1016\/j.wneu.2018.09.180","article-title":"Lateral lumbar interbody fusion revisited: complication avoidance and outcomes with the mini-open approach","volume":"121","author":"Sellin JN","year":"2019","unstructured":"Sellin JN, Brusko GD, Levi AD. Lateral lumbar interbody fusion revisited: complication avoidance and outcomes with the mini-open approach. World Neurosurg. 2019;121:e647\u2013e653.3029203010.1016\/j.wneu.2018.09.180"},{"issue":"1","key":"b9","series-title":"BMC Musculoskelet Disord","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1186\/s12891-019-2992-3","article-title":"Comparison of radiological changes after single- position versus dual- position for lateral interbody fusion and pedicle screw fixation","volume":"20","author":"Hiyama A","year":"2019","unstructured":"Hiyama A, Katoh H, Sakai D,  Comparison of radiological changes after single- position versus dual- position for lateral interbody fusion and pedicle screw fixation. BMC Musculoskelet Disord. 2019;20(1):601.10.1186\/s12891-019-2992-331830959"},{"issue":"2","key":"b10","series-title":"J Spine Surg","doi-asserted-by":"publisher","first-page":"201","DOI":"10.21037\/jss.2019.05.09","article-title":"Analysis of single-position for revision surgery using lateral interbody fusion and pedicle screw fixation: feasibility and perioperative results","volume":"5","author":"Ziino C","year":"2019","unstructured":"Ziino C, Arzeno A, Cheng I. Analysis of single-position for revision surgery using lateral interbody fusion and pedicle screw fixation: feasibility and perioperative results. J Spine Surg. 2019;5(2):201\u2013206.3138047310.21037\/jss.2019.05.09"},{"issue":"6","key":"b11","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1007\/s00586-020-06388-6","article-title":"Simultaneous single-position lateral interbody fusion and percutaneous pedicle screw fixation using O-arm-based navigation reduces the occupancy time of the operating room","volume":"29","author":"Ouchida J","year":"2020","unstructured":"Ouchida J, Kanemura T, Satake K,  Simultaneous single-position lateral interbody fusion and percutaneous pedicle screw fixation using O-arm-based navigation reduces the occupancy time of the operating room. Eur Spine J. 2020;29(6):1277\u20131286.3223935510.1007\/s00586-020-06388-6"},{"issue":"suppl 8","key":"b12","series-title":"Spine (Phila Pa 1976)","first-page":"S152","article-title":"Procedural checklist for retroperitoneal transpsoas minimally invasive lateral interbody fusion","volume":"41","author":"Yen CP","year":"2016","unstructured":"Yen CP, Uribe JS. Procedural checklist for retroperitoneal transpsoas minimally invasive lateral interbody fusion. Spine (Phila Pa 1976). 2016;41(suppl 8):S152\u2013S158."},{"issue":"4","key":"b13","series-title":"Spine J","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.spinee.2005.08.012","article-title":"Extreme Lateral Interbody Fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion","volume":"6","author":"Ozgur BM","year":"2006","unstructured":"Ozgur BM, Aryan HE, Pimenta L, Taylor WR. Extreme Lateral Interbody Fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion. Spine J. 2006;6(4):435\u2013443.1682505210.1016\/j.spinee.2005.08.012"},{"issue":"suppl 2","key":"b14","series-title":"Neurosurgery","first-page":"259","article-title":"Three-dimensional computed tomography-based spinal navigation in minimally invasive lateral lumbar interbody fusion: feasibility, technique, and initial results","volume":"11","author":"Park P","year":"2015","unstructured":"Park P. Three-dimensional computed tomography-based spinal navigation in minimally invasive lateral lumbar interbody fusion: feasibility, technique, and initial results. Neurosurgery. 2015;11(suppl 2):259\u2013267.25812070"},{"issue":"2","key":"b15","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"260","DOI":"10.3171\/2010.3.SPINE09766","article-title":"Defining the safe working zones using the minimally invasive lateral retroperitoneal transpsoas approach: an anatomical study","volume":"13","author":"Uribe JS","year":"2010","unstructured":"Uribe JS, Arredondo N, Dakwar E, Vale FL. Defining the safe working zones using the minimally invasive lateral retroperitoneal transpsoas approach: an anatomical study. J Neurosurg Spine. 2010;13(2):260\u2013266.2067296410.3171\/2010.3.SPINE09766"},{"issue":"26","key":"b16","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"S368","DOI":"10.1097\/BRS.0b013e3182027976","article-title":"Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery","volume":"35","author":"Uribe JS","year":"2010","unstructured":"Uribe JS, Vale FL, Dakwar E. Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery. Spine (Phila Pa 1976). 2010;35(26)(suppl):S368\u2013S374.10.1097\/BRS.0b013e3182027976"},{"key":"b17","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"e208","DOI":"10.1016\/j.wneu.2020.01.134","article-title":"Timing of lateral lumbar interbody subsidence: a review of exclusive intraoperative subsidence","volume":"137","author":"Wewel JT","year":"2020","unstructured":"Wewel JT, Hartman C, Uribe JS. Timing of lateral lumbar interbody subsidence: a review of exclusive intraoperative subsidence. World Neurosurg. 2020;137:e208\u2013e212.10.1016\/j.wneu.2020.01.13431996333"},{"issue":"3","key":"b18","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","DOI":"10.3171\/2014.1.FOCUS13531","article-title":"Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation","volume":"36","author":"Kim TT","year":"2014","unstructured":"Kim TT, Drazin D, Shweikeh F,  Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation. Neurosurg Focus. 2014;36(3):E10.10.3171\/2014.1.FOCUS1353124580001"},{"issue":"4","key":"b19","series-title":"J Spine Surg","doi-asserted-by":"publisher","first-page":"717","DOI":"10.21037\/jss.2018.12.03","article-title":"Single position versus lateral-then-prone positioning for lateral interbody fusion and pedicle screw fixation","volume":"4","author":"Ziino C","year":"2018","unstructured":"Ziino C, Konopka JA, Ajiboye RM,  Single position versus lateral-then-prone positioning for lateral interbody fusion and pedicle screw fixation. J Spine Surg. 2018;4(4):717\u2013724.3071400310.21037\/jss.2018.12.03"},{"issue":"1","key":"b20","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1007\/s00586-020-06303-z","article-title":"Prone single-position extreme lateral interbody fusion (Pro-XLIF): preliminary results","volume":"29","author":"Lamartina C","year":"2020","unstructured":"Lamartina C, Berjano P. Prone single-position extreme lateral interbody fusion (Pro-XLIF): preliminary results. Eur Spine J. 2020;29(1)(suppl 1):6\u201313.3199378910.1007\/s00586-020-06303-z"}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/49\/3\/article-pE15.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/49\/3\/article-pE15.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/49\/3\/article-pE15.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T08:35:07Z","timestamp":1780130107000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/49\/3\/article-pE15.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9]]},"references-count":40,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2020.6.focus20359","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9]]}}}