{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T02:26:20Z","timestamp":1794018380837,"version":"4.8.0"},"reference-count":51,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>The safety of stereo-electroencephalography (SEEG) has been investigated; however, most studies have not differentiated pediatric and adult populations, which have different anatomy and physiology. The purpose of this study was to assess SEEG safety in the pediatric setting, focusing on surgical complications and the identification of patient and surgical risk factors, if any. The authors also aimed to determine whether robot assistance in SEEG was associated with a change in practice, surgical parameters, and clinical outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>The authors retrospectively studied all SEEG cases performed in their department from December 2014 to March 2020. They analyzed both demographic and surgical variables and noted the types of surgery-related complications and their management. They also studied the clinical outcomes of a subset of the patients in relation to robot-assisted and non\u2013robot-assisted SEEG.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>\n                      Sixty-three children had undergone 64 SEEG procedures. Girls were on average 3 years younger than the boys (mean age 11.1 vs 14.1 years, p &lt; 0.01). The overall complication rate was 6.3%, and the complication rate for patients with left-sided electrodes was higher than that for patients with right-sided electrodes (11.1% vs 3.3%), although the difference between the two groups was not statistically significant. The duration of recording was positively correlated to the number of implanted electrodes (r = 0.296, p &lt; 0.05). Robot assistance was associated with a higher number of implanted electrodes (mean 12.6 vs 7.6 electrodes, p &lt; 0.0001). Robot-assisted implantations were more accurate, with a mean error of 1.51 mm at the target compared to 2.98 mm in nonrobot implantations (p &lt; 0.001). Clinical outcomes were assessed in the first 32 patients treated (16 in the nonrobot group and 16 in the robot group), 23 of whom proceeded to further resective surgery. The children who had undergone robot-assisted SEEG had better eventual seizure control following subsequent epilepsy surgery. Of the children who had undergone resective epilepsy surgery, 42% (5\/12) in the nonrobot group and 82% (9\/11) in the robot group obtained an Engel class IA outcome at 1 year (\u03c7\n                      <jats:sup>2<\/jats:sup>\n                      = 3.885, p = 0.049). Based on Kaplan-Meier survival analysis, the robot group had a higher seizure-free rate than the nonrobot group at 30 months postoperation (7\/11 vs 2\/12, p = 0.063). Two complications, whose causes were attributed to the implantation and head-bandaging steps, required surgical intervention. All complications were either transient or reversible.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>This is the largest single-center, exclusively pediatric SEEG series that includes robot assistance so far. SEEG complications are uncommon and usually transient or treatable. Robot assistance enabled implantation of more electrodes and improved epilepsy surgery outcomes, as compared to those in the non\u2013robot-assisted cases.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2021.2.peds20810","type":"journal-article","created":{"date-parts":[[2021,8,5]],"date-time":"2021-08-05T16:21:23Z","timestamp":1628180483000},"page":"404-415","source":"Crossref","is-referenced-by-count":9,"title":["Pediatric stereo-electroencephalography: effects of robot assistance and other variables on seizure outcome and complications"],"prefix":"10.3171","volume":"28","author":[{"given":"Ioannis N.","family":"Mavridis","sequence":"first","affiliation":[{"name":"Departments of Neurosurgery,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William B.","family":"Lo","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Welege Samantha Buddhika","family":"Wimalachandra","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunny","family":"Philip","sequence":"additional","affiliation":[{"name":"Neurology, and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shakti","family":"Agrawal","sequence":"additional","affiliation":[{"name":"Neurology, and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caroline","family":"Scott","sequence":"additional","affiliation":[{"name":"Neurophysiology, Birmingham Children\u2019s Hospital, Birmingham, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Darren","family":"Martin-Lamb","sequence":"additional","affiliation":[{"name":"Neurophysiology, Birmingham Children\u2019s Hospital, Birmingham, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryony","family":"Carr","sequence":"additional","affiliation":[{"name":"Neurophysiology, Birmingham Children\u2019s Hospital, Birmingham, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Bill","sequence":"additional","affiliation":[{"name":"Neurophysiology, Birmingham Children\u2019s Hospital, Birmingham, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Lawley","sequence":"additional","affiliation":[{"name":"Neurophysiology, Birmingham Children\u2019s Hospital, Birmingham, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Seri","sequence":"additional","affiliation":[{"name":"Neurophysiology, Birmingham Children\u2019s Hospital, Birmingham, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. Richard","family":"Walsh","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery,"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"6","key":"b1","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1938","DOI":"10.3171\/2018.7.JNS181164","article-title":"Effective accuracy of stereoelectroencephalography: robotic 3D versus Talairach orthogonal approaches","volume":"131","author":"Bourdillon P","year":"2018","unstructured":"Bourdillon P, Ch\u00e2tillon CE, Moles A,  Effective accuracy of stereoelectroencephalography: robotic 3D versus Talairach orthogonal approaches. J Neurosurg. 2018;131(6):1938\u20131946.10.3171\/2018.7.JNS18116430544338"},{"issue":"11","key":"b2","series-title":"Childs Nerv Syst","doi-asserted-by":"publisher","first-page":"1853","DOI":"10.1007\/s00381-014-2499-z","article-title":"Stereoelectroencephalography in children with cortical dysplasia: technique and results","volume":"30","author":"Gonzalez-Martinez J","year":"2014","unstructured":"Gonzalez-Martinez J, Lachhwani D. Stereoelectroencephalography in children with cortical dysplasia: technique and results. Childs Nerv Syst. 2014;30(11):1853\u20131857.2529654610.1007\/s00381-014-2499-z"},{"issue":"1","key":"b3","series-title":"J Neurosurg Pediatr","doi-asserted-by":"publisher","first-page":"37","DOI":"10.3171\/2018.1.PEDS17435","article-title":"Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique","volume":"22","author":"Abel TJ","year":"2018","unstructured":"Abel TJ, Varela Osorio R, Amorim-Leite R,  Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique. J Neurosurg Pediatr. 2018;22(1):37\u201346.10.3171\/2018.1.PEDS1743529676681"},{"issue":"9","key":"b4","series-title":"Brain","doi-asserted-by":"publisher","first-page":"2688","DOI":"10.1093\/brain\/awz196","article-title":"Stereoelectroencephalography: retrospective analysis of 742 procedures in a single centre","volume":"142","author":"Cardinale F","year":"2019","unstructured":"Cardinale F, Rizzi M, Vignati E,  Stereoelectroencephalography: retrospective analysis of 742 procedures in a single centre. Brain. 2019;142(9):2688\u20132704.10.1093\/brain\/awz196"},{"issue":"4)(suppl","key":"b5","series-title":"J Neurosurg","first-page":"333","article-title":"Stereoelectroencephalography in the presurgical evaluation of children with drug-resistant focal epilepsy","volume":"103","author":"Cossu M","year":"2005","unstructured":"Cossu M, Cardinale F, Colombo N,  Stereoelectroencephalography in the presurgical evaluation of children with drug-resistant focal epilepsy. J Neurosurg. 2005;103(4)(suppl):333\u2013343.16270685"},{"issue":"2","key":"b6","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1227\/NEU.0000000000001034","article-title":"Technique, results, and complications related to robot-assisted stereoelectroencephalography","volume":"78","author":"Gonz\u00e1lez-Mart\u00ednez J","year":"2016","unstructured":"Gonz\u00e1lez-Mart\u00ednez J, Bulacio J, Thompson S,  Technique, results, and complications related to robot-assisted stereoelectroencephalography. Neurosurgery. 2016;78(2):169\u2013180.10.1227\/NEU.000000000000103426418870"},{"issue":"5","key":"b7","series-title":"J Neurosurg Pediatr","doi-asserted-by":"publisher","first-page":"489","DOI":"10.3171\/2018.5.PEDS17718","article-title":"Robot-guided pediatric stereoelectroencephalography: single-institution experience","volume":"22","author":"Ho AL","year":"2018","unstructured":"Ho AL, Muftuoglu Y, Pendharkar AV,  Robot-guided pediatric stereoelectroencephalography: single-institution experience. J Neurosurg Pediatr. 2018;22(5):489\u2013496.10.3171\/2018.5.PEDS17718"},{"issue":"3","key":"b8","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1111\/epi.13298","article-title":"Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications","volume":"57","author":"Mullin JP","year":"2016","unstructured":"Mullin JP, Shriver M, Alomar S,  Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications. Epilepsia. 2016;57(3):386\u2013401.10.1111\/epi.13298"},{"issue":"4","key":"b9","series-title":"Neurochirurgie","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.neuchi.2017.03.002","article-title":"Efficacy and safety in frameless robot-assisted stereo-electroencephalography (SEEG) for drug-resistant epilepsy","volume":"63","author":"Ollivier I","year":"2017","unstructured":"Ollivier I, Behr C, Cebula H,  Efficacy and safety in frameless robot-assisted stereo-electroencephalography (SEEG) for drug-resistant epilepsy. Neurochirurgie. 2017;63(4):286\u2013290.2888260710.1016\/j.neuchi.2017.03.002"},{"issue":"10","key":"b10","series-title":"Int J CARS","doi-asserted-by":"publisher","first-page":"1727","DOI":"10.1007\/s11548-017-1641-2","article-title":"Retrospective evaluation and SEEG trajectory analysis for interactive multi-trajectory planner assistant","volume":"12","author":"Scorza D","year":"2017","unstructured":"Scorza D, De Momi E, Plaino L,  Retrospective evaluation and SEEG trajectory analysis for interactive multi-trajectory planner assistant. Int J CARS. 2017;12(10):1727\u20131738.10.1007\/s11548-017-1641-2"},{"issue":"9","key":"b11","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"1733","DOI":"10.1007\/s00701-017-3242-9","article-title":"Methodology, outcome, safety and in vivo accuracy in traditional frame-based stereoelectroencephalography","volume":"159","author":"van der Loo LE","year":"2017","unstructured":"van der Loo LE, Schijns OEMG, Hoogland G,  Methodology, outcome, safety and in vivo accuracy in traditional frame-based stereoelectroencephalography. Acta Neurochir (Wien). 2017;159(9):1733\u20131746.10.1007\/s00701-017-3242-9"},{"key":"b12","series-title":"Epilepsy Behav","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.yebeh.2018.05.012","article-title":"Invasive EEG-electrodes in presurgical evaluation of epilepsies: Systematic analysis of implantation-, video-EEG-monitoring- and explantation-related complications, and review of literature","volume":"91","author":"Willems LM","year":"2019","unstructured":"Willems LM, Reif PS, Spyrantis A,  Invasive EEG-electrodes in presurgical evaluation of epilepsies: Systematic analysis of implantation-, video-EEG-monitoring- and explantation-related complications, and review of literature. Epilepsy Behav. 2019;91:30\u201337.2990752610.1016\/j.yebeh.2018.05.012"},{"issue":"4","key":"b13","series-title":"J Neurosurg Pediatr","doi-asserted-by":"publisher","first-page":"444","DOI":"10.3171\/2018.5.PEDS1856","article-title":"Safety and efficacy of stereoelectroencephalography in pediatric focal epilepsy: a single-center experience","volume":"22","author":"Goldstein HE","year":"2018","unstructured":"Goldstein HE, Youngerman BE, Shao B,  Safety and efficacy of stereoelectroencephalography in pediatric focal epilepsy: a single-center experience. J Neurosurg Pediatr. 2018;22(4):444\u2013452.3002827010.3171\/2018.5.PEDS1856"},{"issue":"3","key":"b14","series-title":"Oper Neurosurg (Hagerstown)","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1093\/ons\/opz154","article-title":"Robot-assisted insular depth electrode implantation through oblique trajectories: 3-dimensional anatomical nuances, technique, accuracy, and safety","volume":"18","author":"Bottan JS","year":"2020","unstructured":"Bottan JS, Rubino PA, Lau JC,  Robot-assisted insular depth electrode implantation through oblique trajectories: 3-dimensional anatomical nuances, technique, accuracy, and safety. Oper Neurosurg (Hagerstown). 2020;18(3):278\u2013283.10.1093\/ons\/opz15431245818"},{"issue":"4","key":"b15","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.3171\/2017.1.JNS161070","article-title":"Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy","volume":"128","author":"Alomar S","year":"2018","unstructured":"Alomar S, Mullin JP, Smithason S, Gonzalez-Martinez J. Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy. J Neurosurg. 2018;128(4):1147\u20131157.2862162110.3171\/2017.1.JNS161070"},{"key":"b16","series-title":"World Neurosurg","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1016\/j.wneu.2016.12.025","article-title":"Stereotactic electroencephalography is a safe procedure, including for insular implantations","volume":"99","author":"Bourdillon P","year":"2017","unstructured":"Bourdillon P, Ryvlin P, Isnard J,  Stereotactic electroencephalography is a safe procedure, including for insular implantations. World Neurosurg.2017;99:353\u2013361.2800316310.1016\/j.wneu.2016.12.025"},{"issue":"4","key":"b17","series-title":"Seizure","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1016\/j.seizure.2014.01.008","article-title":"Insular and insulo-opercular epilepsy in childhood: an SEEG study","volume":"23","author":"Dylgjeri S","year":"2014","unstructured":"Dylgjeri S, Taussig D, Chipaux M,  Insular and insulo-opercular epilepsy in childhood: an SEEG study. Seizure. 2014;23(4):300\u2013308.2450840210.1016\/j.seizure.2014.01.008"},{"key":"b18","series-title":"Seizure","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.seizure.2020.02.011","article-title":"Stereo-EEG exploration in the insula\/operculum in paediatric patients with refractory epilepsy","volume":"78","author":"Kappen P","year":"2020","unstructured":"Kappen P, Eltze C, Tisdall M,  Stereo-EEG exploration in the insula\/operculum in paediatric patients with refractory epilepsy. Seizure. 2020;78:63\u201370.3220388210.1016\/j.seizure.2020.02.011"},{"issue":"1","key":"b19","series-title":"Oper Neurosurg (Hagerstown)","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/ons\/opx106","article-title":"sEEG is a safe procedure for a comprehensive anatomic exploration of the insula: a retrospective study of 108 procedures representing 254 transopercular insular electrodes","volume":"14","author":"Salado AL","year":"2018","unstructured":"Salado AL, Koessler L, De Mijolla G,  sEEG is a safe procedure for a comprehensive anatomic exploration of the insula: a retrospective study of 108 procedures representing 254 transopercular insular electrodes. Oper Neurosurg (Hagerstown). 2018;14(1):1\u20138.10.1093\/ons\/opx10629117337"},{"issue":"3","key":"b20","series-title":"Neurochirurgie","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.neuchi.2019.12.014","article-title":"Practice of stereoelectroencephalography (sEEG) in drug-resistant epilepsy: Retrospective series with surgery and thermocoagulation outcomes","volume":"66","author":"M\u00e9reaux JL","year":"2020","unstructured":"M\u00e9reaux JL, Gilard V, Le Goff F,  Practice of stereoelectroencephalography (sEEG) in drug-resistant epilepsy: Retrospective series with surgery and thermocoagulation outcomes. Neurochirurgie. 2020;66(3):139\u2013143.10.1016\/j.neuchi.2019.12.01432278000"},{"issue":"3","key":"b21","series-title":"Epileptic Disord","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1684\/epd.2014.0679","article-title":"Stereo-electroencephalography (SEEG) in 65 children: an effective and safe diagnostic method for pre-surgical diagnosis, independent of age","volume":"16","author":"Taussig D","year":"2014","unstructured":"Taussig D, Chipaux M, Lebas A,  Stereo-electroencephalography (SEEG) in 65 children: an effective and safe diagnostic method for pre-surgical diagnosis, independent of age. Epileptic Disord. 2014;16(3):280\u2013295.2525665510.1684\/epd.2014.0679"},{"issue":"3","key":"b22","series-title":"J Neurosurg Pediatr","doi-asserted-by":"publisher","first-page":"288","DOI":"10.3171\/2018.7.PEDS18305","article-title":"Robot-assisted stereoelectroencephalography in children","volume":"23","author":"McGovern RA","year":"2018","unstructured":"McGovern RA, Knight EP, Gupta A,  Robot-assisted stereoelectroencephalography in children. J Neurosurg Pediatr. 2018;23(3):288\u2013296.3054434210.3171\/2018.7.PEDS18305"},{"issue":"7612","key":"b23","series-title":"Lancet","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1016\/S0140-6736(69)92445-3","article-title":"Differential rates of cerebral maturation between sexes and between hemispheres. Evidence from epilepsy","volume":"2","author":"Taylor DC","year":"1969","unstructured":"Taylor DC. Differential rates of cerebral maturation between sexes and between hemispheres. Evidence from epilepsy. Lancet. 1969;2(7612):140\u2013142.10.1016\/S0140-6736(69)92445-34183249"},{"issue":"3","key":"b24","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1111\/epi.14668","article-title":"Risk analysis of hemorrhage in stereo-electroencephalography procedures","volume":"60","author":"McGovern RA","year":"2019","unstructured":"McGovern RA, Ruggieri P, Bulacio J,  Risk analysis of hemorrhage in stereo-electroencephalography procedures. Epilepsia. 2019;60(3):571\u2013580.10.1111\/epi.1466830746685"},{"issue":"3","key":"b25","series-title":"Oper Neurosurg (Hagerstown)","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1093\/ons\/opx192","article-title":"Implantation of depth electrodes in children using VarioGuide\u00ae frameless navigation system: technical note","volume":"15","author":"Budke M","year":"2018","unstructured":"Budke M, Avecillas-Chasin JM, Villarejo F. Implantation of depth electrodes in children using VarioGuide\u00ae frameless navigation system: technical note. Oper Neurosurg (Hagerstown). 2018;15(3):302\u2013309.10.1093\/ons\/opx19228961938"},{"issue":"pt A","key":"b26","series-title":"Epilepsy Behav","doi-asserted-by":"publisher","first-page":"106905","DOI":"10.1016\/j.yebeh.2020.106905","article-title":"Postoperative outcomes following pediatric intracranial electrode monitoring: a case for stereoelectroencephalography (SEEG)","volume":"104","author":"Kim LH","year":"2020","unstructured":"Kim LH, Parker JJ, Ho AL,  Postoperative outcomes following pediatric intracranial electrode monitoring: a case for stereoelectroencephalography (SEEG). Epilepsy Behav. 2020;104(pt A):106905.3202812710.1016\/j.yebeh.2020.106905"},{"issue":"3","key":"b27","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E8","DOI":"10.3171\/2018.6.FOCUS18209","article-title":"Early outcomes of stereoelectroencephalography followed by MR-guided laser interstitial thermal therapy: a paradigm for minimally invasive epilepsy surgery","volume":"45","author":"Cobourn K","year":"2018","unstructured":"Cobourn K, Fayed I, Keating RF, Oluigbo CO. Early outcomes of stereoelectroencephalography followed by MR-guided laser interstitial thermal therapy: a paradigm for minimally invasive epilepsy surgery. Neurosurg Focus. 2018;45(3):E8.3017361010.3171\/2018.6.FOCUS18209"},{"issue":"5","key":"b28","series-title":"Neurosurg Focus","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2017.2.FOCUS16579","article-title":"Robot-assisted procedures in pediatric neurosurgery","volume":"42","author":"De Benedictis A","year":"2017","unstructured":"De Benedictis A, Trezza A, Carai A,  Robot-assisted procedures in pediatric neurosurgery. Neurosurg Focus. 2017;42(5):E7.2846361710.3171\/2017.2.FOCUS16579"},{"issue":"12","key":"b29","series-title":"Acta Neurochir (Wien)","doi-asserted-by":"publisher","first-page":"2489","DOI":"10.1007\/s00701-018-3720-8","article-title":"Frameless robot-assisted stereoelectroencephalography for refractory epilepsy in pediatric patients: accuracy, usefulness, and technical issues","volume":"160","author":"Candela-Cant\u00f3 S","year":"2018","unstructured":"Candela-Cant\u00f3 S, Aparicio J, L\u00f3pez JM,  Frameless robot-assisted stereoelectroencephalography for refractory epilepsy in pediatric patients: accuracy, usefulness, and technical issues. Acta Neurochir (Wien). 2018;160(12):2489\u20132500.10.1007\/s00701-018-3720-830413938"},{"issue":"3","key":"b30","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1227\/NEU.0b013e31827d1161","article-title":"Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures","volume":"72","author":"Cardinale F","year":"2013","unstructured":"Cardinale F, Cossu M, Castana L,  Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery. 2013;72(3):353\u2013366.10.1227\/NEU.0b013e31827d116123168681"},{"issue":"11","key":"b31","series-title":"Childs Nerv Syst","doi-asserted-by":"publisher","first-page":"1875","DOI":"10.1007\/s00381-014-2464-x","article-title":"Outcome of surgery in children with focal cortical dysplasia younger than 5 years explored by stereo-electroencephalography","volume":"30","author":"Dorfm\u00fcller G","year":"2014","unstructured":"Dorfm\u00fcller G, Ferrand-Sorbets S, Fohlen M,  Outcome of surgery in children with focal cortical dysplasia younger than 5 years explored by stereo-electroencephalography. Childs Nerv Syst. 2014;30(11):1875\u20131883.10.1007\/s00381-014-2464-x25296549"},{"issue":"2","key":"b32","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1111\/j.1528-1167.2012.03672.x","article-title":"Stereoelectroencephalography in the \u201cdifficult to localize\u201d refractory focal epilepsy: early experience from a North American epilepsy center","volume":"54","author":"Gonzalez-Martinez J","year":"2013","unstructured":"Gonzalez-Martinez J, Bulacio J, Alexopoulos A,  Stereoelectroencephalography in the \u201cdifficult to localize\u201d refractory focal epilepsy: early experience from a North American epilepsy center. Epilepsia. 2013;54(2):323\u2013330.2301657610.1111\/j.1528-1167.2012.03672.x"},{"issue":"12","key":"b33","series-title":"J Neurol","doi-asserted-by":"publisher","first-page":"2699","DOI":"10.1007\/s00415-015-7901-6","article-title":"Safety profile of intracranial electrode implantation for video-EEG recordings in drug-resistant focal epilepsy","volume":"262","author":"Mathon B","year":"2015","unstructured":"Mathon B, Clemenceau S, Hasboun D,  Safety profile of intracranial electrode implantation for video-EEG recordings in drug-resistant focal epilepsy. J Neurol. 2015;262(12):2699\u20132712.10.1007\/s00415-015-7901-626410749"},{"issue":"3","key":"b34","series-title":"J Neurosurg Pediatr","doi-asserted-by":"publisher","first-page":"290","DOI":"10.3171\/2011.12.PEDS11216","article-title":"Stereoelectroencephalography in the presurgical evaluation of focal epilepsy in infancy and early childhood","volume":"9","author":"Cossu M","year":"2012","unstructured":"Cossu M, Schiariti M, Francione S,  Stereoelectroencephalography in the presurgical evaluation of focal epilepsy in infancy and early childhood. J Neurosurg Pediatr. 2012;9(3):290\u2013300.2238095810.3171\/2011.12.PEDS11216"},{"issue":"4","key":"b35","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1227\/01.NEU.0000176656.33523.1e","article-title":"Stereoelectroencephalography in the presurgical evaluation of focal epilepsy: a retrospective analysis of 215 procedures","volume":"57","author":"Cossu M","year":"2005","unstructured":"Cossu M, Cardinale F, Castana L,  Stereoelectroencephalography in the presurgical evaluation of focal epilepsy: a retrospective analysis of 215 procedures. Neurosurgery. 2005;57(4):706\u2013718.1623988310.1227\/01.NEU.0000176656.33523.1e"},{"issue":"3","key":"b36","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"639","DOI":"10.3171\/2013.11.JNS13635","article-title":"Stereotactic placement of depth electrodes in medically intractable epilepsy","volume":"120","author":"Gonzalez-Martinez J","year":"2014","unstructured":"Gonzalez-Martinez J, Mullin J, Vadera S,  Stereotactic placement of depth electrodes in medically intractable epilepsy. J Neurosurg. 2014;120(3):639\u2013644.10.3171\/2013.11.JNS1363524405074"},{"issue":"2","key":"b37","series-title":"Epileptic Disord","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1684\/epd.2014.0648","article-title":"Paediatric epilepsy surgery in the posterior cortex: a study of 62 cases","volume":"16","author":"Liava A","year":"2014","unstructured":"Liava A, Mai R, Tassi L,  Paediatric epilepsy surgery in the posterior cortex: a study of 62 cases. Epileptic Disord. 2014;16(2):141\u2013164.10.1684\/epd.2014.064824853765"},{"issue":"5","key":"b38","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.3171\/2014.7.JNS132306","article-title":"The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients","volume":"121","author":"Serletis D","year":"2014","unstructured":"Serletis D, Bulacio J, Bingaman W,  The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. J Neurosurg. 2014;121(5):1239\u20131246.2514800710.3171\/2014.7.JNS132306"},{"issue":"1","key":"b39","series-title":"Stereotact Funct Neurosurg","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1159\/000453275","article-title":"A retrospective analysis of stereoelectroencephalography and subdural electroencephalography for preoperative evaluation of intractable epilepsy","volume":"95","author":"Yang M","year":"2017","unstructured":"Yang M, Ma Y, Li W,  A retrospective analysis of stereoelectroencephalography and subdural electroencephalography for preoperative evaluation of intractable epilepsy. Stereotact Funct Neurosurg. 2017;95(1):13\u201320.2808880510.1159\/000453275"},{"key":"b40","series-title":"Neurologia","article-title":"Stereoelectroencephalography in the preoperative assessment of patients with refractory focal epilepsy: experience at an epilepsy centre. Article in Spanish","author":"Toledano R","unstructured":"Toledano R, Mart\u00ednez-\u00c1lvarez R, Jim\u00e9nez-Huete A,  Stereoelectroencephalography in the preoperative assessment of patients with refractory focal epilepsy: experience at an epilepsy centre. Article in Spanish. Neurologia. Published online July 20, 2019. doi:10.1016\/j.nrl.2019.05.00231337558"},{"key":"b41","series-title":"Acta Neurol Scand Suppl","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1111\/j.1600-0404.1994.tb05188.x","article-title":"Stereo-electroencephalography methodology: advantages and limits","volume":"152","author":"Munari C","year":"1994","unstructured":"Munari C, Hoffmann D, Francione S,  Stereo-electroencephalography methodology: advantages and limits. Acta Neurol Scand Suppl. 1994;152:56\u201369.10.1111\/j.1600-0404.1994.tb05188.x8209659"},{"issue":"1-4","key":"b42","series-title":"Stereotact Funct Neurosurg","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1159\/000064595","article-title":"Neurophysiological monitoring for epilepsy surgery: the Talairach SEEG method. StereoElectroEncephaloGraphy. Indications, results, complications and therapeutic applications in a series of 100 consecutive cases","volume":"77","author":"Guenot M","year":"2001","unstructured":"Guenot M, Isnard J, Ryvlin P,  Neurophysiological monitoring for epilepsy surgery: the Talairach SEEG method. StereoElectroEncephaloGraphy. Indications, results, complications and therapeutic applications in a series of 100 consecutive cases. Stereotact Funct Neurosurg. 2001;77(1-4):29\u201332.10.1159\/000064595"},{"issue":"23","key":"b43","series-title":"Medicine (Baltimore)","doi-asserted-by":"publisher","first-page":"e7106","DOI":"10.1097\/MD.0000000000007106","article-title":"Stereoelectroencephalography based on the Leksell stereotactic frame and Neurotech operation planning software","volume":"96","author":"Zhang G","year":"2017","unstructured":"Zhang G, Chen G, Meng D,  Stereoelectroencephalography based on the Leksell stereotactic frame and Neurotech operation planning software. Medicine (Baltimore). 2017;96(23):e7106.10.1097\/MD.000000000000710628591055"},{"issue":"5","key":"b44","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.3171\/2017.6.JNS17881","article-title":"Stereotactic EEG via multiple single-path omnidirectional trajectories within a single platform: institutional experience with a novel technique","volume":"129","author":"Dewan MC","year":"2018","unstructured":"Dewan MC, Shults R, Hale AT,  Stereotactic EEG via multiple single-path omnidirectional trajectories within a single platform: institutional experience with a novel technique. J Neurosurg. 2018;129(5):1173\u20131181.10.3171\/2017.6.JNS1788129243976"},{"issue":"6","key":"b45","series-title":"JAMA Neurol","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1001\/jamaneurol.2019.0098","article-title":"Analysis of morbidity and outcomes associated with use of subdural grids vs stereoelectroencephalography in patients with intractable epilepsy","volume":"76","author":"Tandon N","year":"2019","unstructured":"Tandon N, Tong BA, Friedman ER,  Analysis of morbidity and outcomes associated with use of subdural grids vs stereoelectroencephalography in patients with intractable epilepsy. JAMA Neurol. 2019;76(6):672\u2013681.10.1001\/jamaneurol.2019.009830830149"},{"issue":"6","key":"b46","series-title":"Oper Neurosurg (Hagerstown)","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1093\/ons\/opz247","article-title":"Rigid cranial fixation for robot-assisted stereoelectroencephalography in toddlers: technical considerations","volume":"18","author":"Alexander H","year":"2020","unstructured":"Alexander H, Fayed I, Oluigbo CO. Rigid cranial fixation for robot-assisted stereoelectroencephalography in toddlers: technical considerations. Oper Neurosurg (Hagerstown). 2020;18(6):614\u2013620.10.1093\/ons\/opz24731504837"},{"issue":"1","key":"b47","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"E23","DOI":"10.1093\/neuros\/nyaa112","article-title":"Stereoelectroencephalography versus subdural strip electrode implantations: feasibility, complications, and outcomes in 500 intracranial monitoring cases for drug-resistant epilepsy","volume":"87","author":"Joswig H","year":"2020","unstructured":"Joswig H, Lau JC, Abdallat M,  Stereoelectroencephalography versus subdural strip electrode implantations: feasibility, complications, and outcomes in 500 intracranial monitoring cases for drug-resistant epilepsy. Neurosurgery. 2020;87(1):E23\u2013E30.3235721710.1093\/neuros\/nyaa112"},{"issue":"6","key":"b48","series-title":"Neurocirugia (Astur)","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.neucir.2016.05.002","article-title":"Stereoelectroencephalography by using O-Arm\u00ae and Vertek\u00ae passive articulated arm: technical note and experience of an epilepsy referral centre. Article in Spanish","volume":"27","author":"Narv\u00e1ez-Mart\u00ednez Y","year":"2016","unstructured":"Narv\u00e1ez-Mart\u00ednez Y, Garc\u00eda S, Rold\u00e1n P,  Stereoelectroencephalography by using O-Arm\u00ae and Vertek\u00ae passive articulated arm: technical note and experience of an epilepsy referral centre. Article in Spanish. Neurocirugia (Astur). 2016;27(6):277\u2013284.10.1016\/j.neucir.2016.05.00227345416"},{"issue":"6","key":"b49","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1190","DOI":"10.1093\/neuros\/nyy466","article-title":"Is the use of stereotactic electroencephalography safe and effective in children? A meta-analysis of the use of stereotactic electroencephalography in comparison to subdural grids for invasive epilepsy monitoring in pediatric subjects","volume":"84","author":"Sacino MF","year":"2019","unstructured":"Sacino MF, Huang SS, Schreiber J,  Is the use of stereotactic electroencephalography safe and effective in children? A meta-analysis of the use of stereotactic electroencephalography in comparison to subdural grids for invasive epilepsy monitoring in pediatric subjects. Neurosurgery. 2019;84(6):1190\u20131200.10.1093\/neuros\/nyy46630351382"},{"issue":"5","key":"b50","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1227\/NEU.0b013e318285b4ae","article-title":"Stereoelectroencephalography following subdural grid placement for difficult to localize epilepsy","volume":"72","author":"Vadera S","year":"2013","unstructured":"Vadera S, Mullin J, Bulacio J,  Stereoelectroencephalography following subdural grid placement for difficult to localize epilepsy. Neurosurgery. 2013;72(5):723\u2013729.2331397910.1227\/NEU.0b013e318285b4ae"},{"key":"b51","series-title":"Surgical Treatment of the Epilepsies","first-page":"609","article-title":"Outcome with respect to epileptic seizures","author":"Engel J Jr","year":"1993","unstructured":"Engel J Jr, Van Ness PC, Rasmussen TB, Ojemann LM. Outcome with respect to epileptic seizures. In: Engel J Jr, ed.Surgical Treatment of the Epilepsies.2nd ed. Raven Press;1993:609\u2013621."}],"container-title":["Journal of Neurosurgery: Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/28\/4\/article-p404.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/28\/4\/article-p404.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/28\/4\/article-p404.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T02:07:54Z","timestamp":1794017274000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/28\/4\/article-p404.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":51,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3171\/2021.2.peds20810","relation":{},"ISSN":["1933-0707","1933-0715"],"issn-type":[{"value":"1933-0707","type":"print"},{"value":"1933-0715","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10]]}}}