{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T22:43:52Z","timestamp":1782168232992,"version":"3.54.5"},"reference-count":26,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Sacroiliac joint (SIJ) fusion utilizing intraoperative navigation requires a standard reference frame, which is often placed using a percutaneous pin. Proper placement ensures the correct positioning of SIJ fusion implants. There is currently no grading scheme for evaluation of pin placement into the pelvis. The purpose of this study was to evaluate the occurrence of ideal percutaneous pin placement into the posterior ilium during navigated SIJ fusion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>After IRB approval was obtained, electronic medical records and intraoperative computed tomography images of patients who underwent navigated SIJ fusion by the senior author between October 2013 and January 2020 were reviewed. A pin placement grading scheme and the definition of \"ideal\" placement were developed by the authors and deemed acceptable by fellow attending surgeons. Six attending surgeons completed two rounds of pin placement grading, and statistical analysis was conducted.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>Of 90 eligible patients, 73.3% had ideal pin placement, 17.8% medial\/lateral breach, and 8.9% complete miss. Male patients were 3.7 times more likely to have ideal placement than females (p &lt; 0.05). There was no relationship between BMI, SIJ fusion laterality, or pin placement laterality and ideal placement. Interobserver reliability was 0.72 and 0.70 in the first and second rounds, respectively, and defined as \"substantial agreement.\" Intraobserver reliability ranged from 0.74 (substantial agreement) to 0.92 (almost perfect agreement).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>Nonideal pin placement occurred in 26.7% of cases, but a true \"miss\" into the sacrum was rare. Ideal pin placement was more likely in males and was not associated with BMI, SIJ fusion laterality, or pin placement laterality. The grading scheme developed has high intraobserver and interobserver reliability, indicating that it is reproducible and can be used for future studies. When placing percutaneous pins, surgeons must be aware of factors that can decrease placement accuracy, regardless of location.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2022.10.focus22608","type":"journal-article","created":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T08:58:57Z","timestamp":1672563537000},"page":"E9","source":"Crossref","is-referenced-by-count":5,"title":["Sacroiliac joint fusion navigation: how accurate is pin placement?"],"prefix":"10.3171","volume":"54","author":[{"given":"Shea M.","family":"Comadoll","sequence":"first","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason J.","family":"Haselhuhn","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan N.","family":"Sembrano","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian M.","family":"Ogilvie","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward Y.","family":"Cheng","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristen E.","family":"Jones","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"},{"name":"Neurosurgery, University of Minnesota, Minneapolis, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher T.","family":"Martin","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David W.","family":"Polly","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"},{"name":"Neurosurgery, University of Minnesota, Minneapolis, Minnesota"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"4","key":"b1","series-title":"JBJS Essent Surg Tech","doi-asserted-by":"publisher","first-page":"e19.00067","DOI":"10.2106\/JBJS.ST.19.00067","article-title":"Minimally invasive sacroiliac joint fusion: a lateral approach using triangular titanium implants and navigation","volume":"10","author":"Polly DW Jr","year":"2020","unstructured":"Polly DW Jr, Holton KJ. Minimally invasive sacroiliac joint fusion: a lateral approach using triangular titanium implants and navigation. JBJS Essent Surg Tech. 2020;10(4):e19.00067.10.2106\/JBJS.ST.19.0006728270652"},{"issue":"2","key":"b2","series-title":"J Biomed Res","first-page":"162","article-title":"Stereotactic guidance for navigated percutaneous sacroiliac joint fusion","volume":"30","author":"Lee DJ","year":"2016","unstructured":"Lee DJ, Kim SB, Rosenthal P, Panchal RR, Kim KD. Stereotactic guidance for navigated percutaneous sacroiliac joint fusion. J Biomed Res. 2016;30(2):162\u2013167.35175374"},{"issue":"25","key":"b3","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E1580","DOI":"10.1097\/BRS.0b013e318271b1fa","article-title":"A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation","volume":"37","author":"Van de Kelft E","year":"2012","unstructured":"Van de Kelft E, Costa F, Van der Planken D, Schils F. A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation. Spine (Phila Pa 1976). 2012;37(25):E1580\u2013E1587.10.1097\/BRS.0b013e318271b1fa17487662"},{"issue":"3","key":"b4","series-title":"Bone Joint J","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1302\/0301-620X.102B3.BJJ-2019-1499.R1","article-title":"Ten techniques for improving navigated spinal surgery","volume":"102-B","author":"Cawley D","year":"2020","unstructured":"Cawley D, Dhokia R, Sales J, Darwish N, Molloy S. Ten techniques for improving navigated spinal surgery. Bone Joint J. 2020;102-B(3):371-375.10.1302\/0301-620X.102B3.BJJ-2019-1499.R128270652"},{"issue":"2","key":"b5","series-title":"Arch Orthop Trauma Surg","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1007\/s00402-018-3055-1","article-title":"Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation","volume":"139","author":"Takao M","year":"2019","unstructured":"Takao M, Hamada H, Sakai T, Sugano N. Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation. Arch Orthop Trauma Surg. 2019;139(2):189\u2013195.10.1007\/s00402-018-3055-135175374"},{"issue":"9","key":"b6","series-title":"Int Orthop","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1007\/s00264-010-1092-7","article-title":"Factors influencing the accuracy of iliosacral screw placement in trauma patients","volume":"35","author":"Grossterlinden L","year":"2011","unstructured":"Grossterlinden L, Rueger J, Catala-Lehnen P,  Factors influencing the accuracy of iliosacral screw placement in trauma patients. Int Orthop. 2011;35(9):1391\u20131396.10.1007\/s00264-010-1092-717487662"},{"issue":"2","key":"b7","series-title":"J Spine Surg","doi-asserted-by":"publisher","first-page":"141","DOI":"10.21037\/jss-20-687","article-title":"Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes","volume":"7","author":"Avrumova F","year":"2021","unstructured":"Avrumova F, Morse KW, Heath M, Widmann RF, Lebl DR. Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes. J Spine Surg. 2021;7(2):141\u2013154.10.21037\/jss-20-687"},{"issue":"1","key":"b8","series-title":"Biometrics","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis JR","year":"1977","unstructured":"Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159\u2013174.10.2307\/2529310"},{"issue":"2","key":"b9","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"208","DOI":"10.3171\/2022.1.SPINE211496","article-title":"The impact of misplaced percutaneous iliac dynamic reference frame pins used during navigated spine surgery: incidence and outcomes","volume":"37","author":"Holste KG","year":"2022","unstructured":"Holste KG, Zaki MM, Wieland CM, Saadeh YS, Park P. The impact of misplaced percutaneous iliac dynamic reference frame pins used during navigated spine surgery: incidence and outcomes. J Neurosurg Spine. 2022;37(2):208\u2013212.10.3171\/2022.1.SPINE211496"},{"key":"b10","article-title":"Iliac dysmorphism: defining radiographic characteristics and association with pelvic osseous corridor size. Arch Orthop Trauma Surg","author":"Wang M","unstructured":"Wang M, Jacobs RC, Bartlett CS, Schottel PC. Iliac dysmorphism: defining radiographic characteristics and association with pelvic osseous corridor size. Arch Orthop Trauma Surg. Published online February 17, 2022. doi:10.1007\/s00402-022-04376-7"},{"issue":"1","key":"b11","series-title":"Comput Assist Surg (Abingdon)","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1080\/24699322.2018.1542028","article-title":"Is bony attachment necessary for dynamic reference frame in navigation-assisted minimally invasive lumbar spine fusion surgery?","volume":"24","author":"Lin HH","year":"2019","unstructured":"Lin HH, Lu YH, Chou PH, Chang MC, Wang ST, Liu CL. Is bony attachment necessary for dynamic reference frame in navigation-assisted minimally invasive lumbar spine fusion surgery?. Comput Assist Surg (Abingdon). 2019;24(1):7\u201312.10.1080\/24699322.2018.1542028"},{"issue":"6","key":"b12","series-title":"Comput Aided Surg","doi-asserted-by":"publisher","first-page":"300","DOI":"10.3109\/10929088.2012.728625","article-title":"The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion","volume":"17","author":"Cho JY","year":"2012","unstructured":"Cho JY, Chan CK, Lee SH, Lee HY. The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion. Comput Aided Surg. 2012;17(6):300\u2013309.10.3109\/10929088.2012.728625"},{"issue":"2","key":"b13","series-title":"Comput Aided Surg","first-page":"125","article-title":"Fracture-table-mounted versus bone-mounted dynamic reference frame tracking accuracy using computer-assisted orthopaedic surgery\u2014a comparative study","volume":"12","author":"Ilsar I","year":"2007","unstructured":"Ilsar I, Weil YA, Joskowicz L, Mosheiff R, Liebergall M. Fracture-table-mounted versus bone-mounted dynamic reference frame tracking accuracy using computer-assisted orthopaedic surgery\u2014a comparative study. Comput Aided Surg. 2007;12(2):125\u2013130."},{"issue":"4","key":"b1","series-title":"JBJS Essent Surg Tech","doi-asserted-by":"publisher","first-page":"e19.00067","DOI":"10.2106\/JBJS.ST.19.00067","article-title":"Minimally invasive sacroiliac joint fusion: a lateral approach using triangular titanium implants and navigation","volume":"10","author":"Polly DW Jr","year":"2020","unstructured":"Polly DW Jr, Holton KJ. Minimally invasive sacroiliac joint fusion: a lateral approach using triangular titanium implants and navigation. JBJS Essent Surg Tech. 2020;10(4):e19.00067.10.2106\/JBJS.ST.19.00067"},{"issue":"2","key":"b2","series-title":"J Biomed Res","first-page":"162","article-title":"Stereotactic guidance for navigated percutaneous sacroiliac joint fusion","volume":"30","author":"Lee DJ","year":"2016","unstructured":"Lee DJ, Kim SB, Rosenthal P, Panchal RR, Kim KD. Stereotactic guidance for navigated percutaneous sacroiliac joint fusion. J Biomed Res. 2016;30(2):162\u2013167."},{"issue":"25","key":"b3","series-title":"Spine (Phila Pa 1976)","doi-asserted-by":"publisher","first-page":"E1580","DOI":"10.1097\/BRS.0b013e318271b1fa","article-title":"A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation","volume":"37","author":"Van de Kelft E","year":"2012","unstructured":"Van de Kelft E, Costa F, Van der Planken D, Schils F. A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation. Spine (Phila Pa 1976). 2012;37(25):E1580\u2013E1587.10.1097\/BRS.0b013e318271b1fa"},{"issue":"3","key":"b4","series-title":"Bone Joint J","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1302\/0301-620X.102B3.BJJ-2019-1499.R1","article-title":"Ten techniques for improving navigated spinal surgery","volume":"102-B","author":"Cawley D","year":"2020","unstructured":"Cawley D, Dhokia R, Sales J, Darwish N, Molloy S. Ten techniques for improving navigated spinal surgery. Bone Joint J. 2020;102-B(3):371-375.10.1302\/0301-620X.102B3.BJJ-2019-1499.R1"},{"issue":"2","key":"b5","series-title":"Arch Orthop Trauma Surg","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1007\/s00402-018-3055-1","article-title":"Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation","volume":"139","author":"Takao M","year":"2019","unstructured":"Takao M, Hamada H, Sakai T, Sugano N. Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation. Arch Orthop Trauma Surg. 2019;139(2):189\u2013195.10.1007\/s00402-018-3055-1"},{"issue":"9","key":"b6","series-title":"Int Orthop","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1007\/s00264-010-1092-7","article-title":"Factors influencing the accuracy of iliosacral screw placement in trauma patients","volume":"35","author":"Grossterlinden L","year":"2011","unstructured":"Grossterlinden L, Rueger J, Catala-Lehnen P,  Factors influencing the accuracy of iliosacral screw placement in trauma patients. Int Orthop. 2011;35(9):1391\u20131396.10.1007\/s00264-010-1092-7"},{"issue":"2","key":"b7","series-title":"J Spine Surg","doi-asserted-by":"publisher","first-page":"141","DOI":"10.21037\/jss-20-687","article-title":"Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes","volume":"7","author":"Avrumova F","year":"2021","unstructured":"Avrumova F, Morse KW, Heath M, Widmann RF, Lebl DR. Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes. J Spine Surg. 2021;7(2):141\u2013154.10.21037\/jss-20-687"},{"issue":"1","key":"b8","series-title":"Biometrics","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis JR","year":"1977","unstructured":"Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159\u2013174.10.2307\/2529310"},{"issue":"2","key":"b9","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"208","DOI":"10.3171\/2022.1.SPINE211496","article-title":"The impact of misplaced percutaneous iliac dynamic reference frame pins used during navigated spine surgery: incidence and outcomes","volume":"37","author":"Holste KG","year":"2022","unstructured":"Holste KG, Zaki MM, Wieland CM, Saadeh YS, Park P. The impact of misplaced percutaneous iliac dynamic reference frame pins used during navigated spine surgery: incidence and outcomes. J Neurosurg Spine. 2022;37(2):208\u2013212.10.3171\/2022.1.SPINE211496"},{"key":"b10","article-title":"Iliac dysmorphism: defining radiographic characteristics and association with pelvic osseous corridor size. Arch Orthop Trauma Surg","author":"Wang M","unstructured":"Wang M, Jacobs RC, Bartlett CS, Schottel PC. Iliac dysmorphism: defining radiographic characteristics and association with pelvic osseous corridor size. Arch Orthop Trauma Surg. Published online February 17, 2022. doi:10.1007\/s00402-022-04376-7"},{"issue":"1","key":"b11","series-title":"Comput Assist Surg (Abingdon)","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1080\/24699322.2018.1542028","article-title":"Is bony attachment necessary for dynamic reference frame in navigation-assisted minimally invasive lumbar spine fusion surgery?","volume":"24","author":"Lin HH","year":"2019","unstructured":"Lin HH, Lu YH, Chou PH, Chang MC, Wang ST, Liu CL. Is bony attachment necessary for dynamic reference frame in navigation-assisted minimally invasive lumbar spine fusion surgery?. Comput Assist Surg (Abingdon). 2019;24(1):7\u201312.10.1080\/24699322.2018.1542028"},{"issue":"6","key":"b12","series-title":"Comput Aided Surg","doi-asserted-by":"publisher","first-page":"300","DOI":"10.3109\/10929088.2012.728625","article-title":"The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion","volume":"17","author":"Cho JY","year":"2012","unstructured":"Cho JY, Chan CK, Lee SH, Lee HY. The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion. Comput Aided Surg. 2012;17(6):300\u2013309.10.3109\/10929088.2012.728625"},{"issue":"2","key":"b13","series-title":"Comput Aided Surg","first-page":"125","article-title":"Fracture-table-mounted versus bone-mounted dynamic reference frame tracking accuracy using computer-assisted orthopaedic surgery\u2014a comparative study","volume":"12","author":"Ilsar I","year":"2007","unstructured":"Ilsar I, Weil YA, Joskowicz L, Mosheiff R, Liebergall M. Fracture-table-mounted versus bone-mounted dynamic reference frame tracking accuracy using computer-assisted orthopaedic surgery\u2014a comparative study. Comput Aided Surg. 2007;12(2):125\u2013130."}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/54\/1\/article-pE9.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/54\/1\/article-pE9.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/54\/1\/article-pE9.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T08:12:52Z","timestamp":1780733572000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/54\/1\/article-pE9.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":26,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3171\/2022.10.focus22608","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]}}}