{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T02:12:36Z","timestamp":1790734356654,"version":"4.1.0"},"reference-count":28,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,3,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Recent trends have moved from subdural grid electrocorticography (ECoG) recordings toward stereo-electroencephalography (SEEG) depth electrodes for intracranial localization of seizures, in part because of perceived morbidity from subdural grid and strip electrodes. For invasive epilepsy monitoring, the authors describe the outcomes of a hybrid approach, whereby patients receive a combination of subdural grids, strips, and frameless stereotactic depth electrode implantations through a craniotomy. Evolution of surgical techniques was employed to reduce complications. In this study, the authors review the surgical hemorrhage and functional outcomes of this hybrid approach.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>A retrospective review was performed of consecutive patients who underwent hybrid implantation from July 2012 to May 2022 at an academic epilepsy center by a single surgeon. Outcomes included hemorrhagic and nonhemorrhagic complications, neurological deficits, length of monitoring, and number of electrodes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>A total of 137 consecutive procedures were performed; 113 procedures included both subdural and depth electrodes. The number of depth electrodes and electrode contacts did not increase the risk of hemorrhage. A mean of 1.9 \u00b1 0.8 grid, 4.9 \u00b1 2.1 strip, and 3.0 \u00b1 1.9 depth electrodes were implanted, for a mean of 125.1 \u00b1 32 electrode contacts per patient. The overall incidence of hematomas over the study period was 5.1% (7 patients) and decreased significantly with experience and the introduction of new surgical techniques. The incidence of hematomas in the last 4 years of the study period was 0% (55 patients). Symptomatic hematomas were all delayed and extra-axial. These patients required surgical evacuation, and there were no cases of hematoma recurrence. All neurological deficits related to hematomas were temporary and were resolved at hospital discharge. There were 2 nonhemorrhagic complications. The mean duration of monitoring was 7.3 \u00b1 3.2 days. Seizures were localized in 95% of patients, with 77% of patients eventually undergoing resection and 17% undergoing responsive neurostimulation device implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>In the authors\u2019 institutional experience, craniotomy-based subdural and depth electrode implantation was associated with low hemorrhage rates and no permanent morbidity. The rate of hemorrhage can be nearly eliminated with surgical experience and specific techniques. The decision to use subdural electrodes or SEEG should be tailored to the patient\u2019s unique pathology and surgeon experience.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2022.5.jns221118","type":"journal-article","created":{"date-parts":[[2022,7,22]],"date-time":"2022-07-22T08:32:42Z","timestamp":1658478762000},"page":"821-827","source":"Crossref","is-referenced-by-count":15,"title":["Modern intracranial electroencephalography for epilepsy localization with combined subdural grid and depth electrodes with low and improved hemorrhagic complication rates"],"prefix":"10.3171","volume":"138","author":[{"given":"Anthony T.","family":"Lee","sequence":"first","affiliation":[{"name":"Departments of Neurological Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noah M.","family":"Nichols","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin A.","family":"Speidel","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joline M.","family":"Fan","sequence":"additional","affiliation":[{"name":"Neurology, University of California, San Francisco, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iahn","family":"Cajigas","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert C.","family":"Knowlton","sequence":"additional","affiliation":[{"name":"Neurology, University of California, San Francisco, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward F.","family":"Chang","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"7","key":"b1","series-title":"Neurology","first-page":"1358","article-title":"Preoperative MRI predicts outcome of temporal lobectomy: an actuarial analysis","volume":"45","author":"Berkovic SF","year":"1995","unstructured":"Berkovic SF, McIntosh AM, Kalnins RM,  Preoperative MRI predicts outcome of temporal lobectomy: an actuarial analysis. Neurology. 1995;45(7):1358\u20131363.7617198"},{"issue":"6","key":"b2","series-title":"Neurology","first-page":"912","article-title":"Predicting long-term seizure outcome after resective epilepsy surgery: the multicenter study","volume":"65","author":"Spencer SS","year":"2005","unstructured":"Spencer SS, Berg AT, Vickrey BG,  Predicting long-term seizure outcome after resective epilepsy surgery: the multicenter study. Neurology. 2005;65(6):912\u2013918.16186534"},{"issue":"5","key":"b3","series-title":"J Neurosurg","first-page":"1042","article-title":"Rates and predictors of long-term seizure freedom after frontal lobe epilepsy surgery: a systematic review and meta-analysis","volume":"116","author":"Englot DJ","year":"2012","unstructured":"Englot DJ, Wang DD, Rolston JD, Shih TT, Chang EF. Rates and predictors of long-term seizure freedom after frontal lobe epilepsy surgery: a systematic review and meta-analysis. J Neurosurg. 2012;116(5):1042\u20131048.22304450"},{"issue":"2-3","key":"b4","series-title":"Epilepsy Res","first-page":"310","article-title":"Surgical outcomes in lesional and non-lesional epilepsy: a systematic review and meta-analysis","volume":"89","author":"T\u00e9llez-Zenteno JF","year":"2010","unstructured":"T\u00e9llez-Zenteno JF, Hern\u00e1ndez Ronquillo L, Moien-Afshari F, Wiebe S. Surgical outcomes in lesional and non-lesional epilepsy: a systematic review and meta-analysis. Epilepsy Res. 2010;89(2-3):310\u2013318.20227852"},{"issue":"7","key":"b5","series-title":"Cochrane Database Syst Rev","first-page":"CD010541","article-title":"Surgery for epilepsy","author":"West S","year":"2015","unstructured":"West S, Nolan SJ, Cotton J,  Surgery for epilepsy. Cochrane Database Syst Rev. 2015;(7):CD010541.26130264"},{"issue":"1","key":"b6","series-title":"Ann Neurol","first-page":"35","article-title":"Functional imaging: II. Prediction of epilepsy surgery outcome","volume":"64","author":"Knowlton RC","year":"2008","unstructured":"Knowlton RC, Elgavish RA, Bartolucci A,  Functional imaging: II. Prediction of epilepsy surgery outcome. Ann Neurol. 2008;64(1):35\u201341.18570291"},{"issue":"2","key":"b7","series-title":"Curr Opin Neurol","first-page":"192","article-title":"The current place of epilepsy surgery","volume":"31","author":"Engel J Jr","year":"2018","unstructured":"Engel J Jr. The current place of epilepsy surgery. Curr Opin Neurol. 2018;31(2):192\u2013197.29278548"},{"issue":"1","key":"b8","series-title":"Electroencephalogr Clin Neurophysiol","first-page":"85","article-title":"Functional stereotaxic exploration (SEEG) of epilepsy","volume":"28","author":"Bancaud J","year":"1970","unstructured":"Bancaud J, Angelergues R, Bernouilli C,  Functional stereotaxic exploration (SEEG) of epilepsy. Electroencephalogr Clin Neurophysiol. 1970;28(1):85\u201386.4188481"},{"key":"b9","series-title":"J Clin Neurosci","first-page":"132","article-title":"Increased nationwide use of stereoencephalography for intracranial epilepsy electroencephalography recordings","volume":"53","author":"Abou-Al-Shaar H","year":"2018","unstructured":"Abou-Al-Shaar H, Brock AA, Kundu B, Englot DJ, Rolston JD. Increased nationwide use of stereoencephalography for intracranial epilepsy electroencephalography recordings. J Clin Neurosci. 2018;53:132\u2013134.29724650"},{"issue":"2","key":"b10","series-title":"Neurosurgery","first-page":"169","article-title":"Technique, results, and complications related to robot-assisted stereoelectroencephalography","volume":"78","author":"Gonz\u00e1lez-Mart\u00ednez J","year":"2016","unstructured":"Gonz\u00e1lez-Mart\u00ednez J, Bulacio J, Thompson S,  Technique, results, and complications related to robot-assisted stereoelectroencephalography. Neurosurgery. 2016;78(2):169\u2013180.26418870"},{"issue":"4","key":"b11","series-title":"J Neurosurg","first-page":"1180","article-title":"Intracranial EEG for seizure focus localization: evolving techniques, outcomes, complications, and utility of combining surface and depth electrodes","volume":"130","author":"Nagahama Y","year":"2019","unstructured":"Nagahama Y, Schmitt AJ, Nakagawa D,  Intracranial EEG for seizure focus localization: evolving techniques, outcomes, complications, and utility of combining surface and depth electrodes. J Neurosurg. 2019;130(4):1180\u20131192."},{"issue":"6","key":"b12","series-title":"JAMA Neurol","first-page":"672","article-title":"Analysis of morbidity and outcomes associated with use of subdural grids vs stereoelectroencephalography in patients with intractable epilepsy","volume":"76","author":"Tandon N","year":"2019","unstructured":"Tandon N, Tong BA, Friedman ER,  Analysis of morbidity and outcomes associated with use of subdural grids vs stereoelectroencephalography in patients with intractable epilepsy. JAMA Neurol. 2019;76(6):672\u2013681.30830149"},{"issue":"38","key":"b13","series-title":"J Neurosci","first-page":"12662","article-title":"Control of spoken vowel acoustics and the influence of phonetic context in human speech sensorimotor cortex","volume":"34","author":"Bouchard KE","year":"2014","unstructured":"Bouchard KE, Chang EF. Control of spoken vowel acoustics and the influence of phonetic context in human speech sensorimotor cortex. J Neurosci. 2014;34(38):12662\u201312677.25232105"},{"issue":"6174","key":"b14","series-title":"Science","first-page":"1006","article-title":"Phonetic feature encoding in human superior temporal gyrus","volume":"343","author":"Mesgarani N","year":"2014","unstructured":"Mesgarani N, Cheung C, Johnson K, Chang EF. Phonetic feature encoding in human superior temporal gyrus. Science. 2014;343(6174):1006\u20131010.24482117"},{"issue":"2","key":"b15","series-title":"Neuroimage","first-page":"179","article-title":"Cortical surface-based analysis. I. Segmentation and surface reconstruction","volume":"9","author":"Dale AM","year":"1999","unstructured":"Dale AM, Fischl B, Sereno MI. Cortical surface-based analysis. I. Segmentation and surface reconstruction. Neuroimage. 1999;9(2):179\u2013194.9931268"},{"issue":"3","key":"b16","series-title":"Neuroimage","first-page":"968","article-title":"An automated labeling system for subdividing the human cerebral cortex on MRI scans into gyral based regions of interest","volume":"31","author":"Desikan RS","year":"2006","unstructured":"Desikan RS, S\u00e9gonne F, Fischl B,  An automated labeling system for subdividing the human cerebral cortex on MRI scans into gyral based regions of interest. Neuroimage. 2006;31(3):968\u2013980.16530430"},{"issue":"1","key":"b17","series-title":"Neuroimage","first-page":"1","article-title":"Automatic parcellation of human cortical gyri and sulci using standard anatomical nomenclature","volume":"53","author":"Destrieux C","year":"2010","unstructured":"Destrieux C, Fischl B, Dale A, Halgren E. Automatic parcellation of human cortical gyri and sulci using standard anatomical nomenclature. Neuroimage. 2010;53(1):1\u201315.20547229"},{"issue":"1","key":"b18","series-title":"Neurology","first-page":"97","article-title":"Complications of invasive video-EEG monitoring with subdural grid electrodes","volume":"58","author":"Hamer HM","year":"2002","unstructured":"Hamer HM, Morris HH, Mascha EJ,  Complications of invasive video-EEG monitoring with subdural grid electrodes. Neurology. 2002;58(1):97\u2013103.11781412"},{"issue":"3","key":"b19","series-title":"Neurosurgery","first-page":"498","article-title":"Intracranial electroencephalography with subdural grid electrodes: techniques, complications, and outcomes","volume":"63","author":"Van Gompel JJ","year":"2008","unstructured":"Van Gompel JJ, Worrell GA, Bell ML,  Intracranial electroencephalography with subdural grid electrodes: techniques, complications, and outcomes. Neurosurgery. 2008;63(3):498\u2013506.18812961"},{"issue":"8","key":"b20","series-title":"Epilepsia","first-page":"1322","article-title":"Risks and benefits of invasive epilepsy surgery workup with implanted subdural and depth electrodes","volume":"53","author":"Wellmer J","year":"2012","unstructured":"Wellmer J, von der Groeben F, Klarmann U,  Risks and benefits of invasive epilepsy surgery workup with implanted subdural and depth electrodes. Epilepsia. 2012;53(8):1322\u20131332.22708979"},{"issue":"7","key":"b21","series-title":"J Neurol Neurosurg Psychiatry","first-page":"716","article-title":"Complications to invasive epilepsy surgery workup with subdural and depth electrodes: a prospective population-based observational study","volume":"85","author":"Hedeg\u00e4rd E","year":"2014","unstructured":"Hedeg\u00e4rd E, Bjellvi J, Edelvik A, Rydenhag B, Flink R, Malmgren K. Complications to invasive epilepsy surgery workup with subdural and depth electrodes: a prospective population-based observational study. J Neurol Neurosurg Psychiatry. 2014;85(7):716\u2013720.24293000"},{"issue":"10","key":"b22","series-title":"Epilepsia","first-page":"1697","article-title":"Complications of subdural and depth electrodes in 269 patients undergoing 317 procedures for invasive monitoring in epilepsy","volume":"57","author":"Schmidt RF","year":"2016","unstructured":"Schmidt RF, Wu C, Lang MJ,  Complications of subdural and depth electrodes in 269 patients undergoing 317 procedures for invasive monitoring in epilepsy. Epilepsia. 2016;57(10):1697\u20131708.27549686"},{"issue":"6","key":"b23","series-title":"J Neurosurg","first-page":"1415","article-title":"Evolution of cranial epilepsy surgery complication rates: a 32-year systematic review and meta-analysis","volume":"120","author":"Tebo CC","year":"2014","unstructured":"Tebo CC, Evins AI, Christos PJ, Kwon J, Schwartz TH. Evolution of cranial epilepsy surgery complication rates: a 32-year systematic review and meta-analysis. J Neurosurg. 2014;120(6):1415\u20131427."},{"issue":"5","key":"b24","series-title":"Epilepsia","first-page":"828","article-title":"Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: a systematic review and meta-analysis","volume":"54","author":"Arya R","year":"2013","unstructured":"Arya R, Mangano FT, Horn PS, Holland KD, Rose DF, Glauser TA. Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: a systematic review and meta-analysis. Epilepsia. 2013;54(5):828\u2013839.23294329"},{"issue":"4","key":"b25","series-title":"Neurosurg Clin N Am","first-page":"519","article-title":"Implanted subdural electrodes: safety issues and complication avoidance","volume":"22","author":"Fountas KN","year":"2011","unstructured":"Fountas KN. Implanted subdural electrodes: safety issues and complication avoidance. Neurosurg Clin N Am. 2011;22(4):519\u2013531, vii.21939850"},{"issue":"3","key":"b26","series-title":"Epilepsia","first-page":"571","article-title":"Risk analysis of hemorrhage in stereo-electroencephalography procedures","volume":"60","author":"McGovern RA","year":"2019","unstructured":"McGovern RA, Ruggieri P, Bulacio J, Najm I, Bingaman WE, Gonzalez-Martinez JA. Risk analysis of hemorrhage in stereo-electroencephalography procedures. Epilepsia. 2019;60(3):571\u2013580.30746685"},{"issue":"5 suppl","key":"b27","series-title":"Louis Children\u2019s Hospital, 1994-2005. J Neurosurg","first-page":"343","article-title":"Complications of invasive subdural electrode monitoring at St","volume":"105","author":"Johnston JM Jr","year":"2006","unstructured":"Johnston JM Jr, Mangano FT, Ojemann JG, Park TS, Trevathan E, Smyth MD. Complications of invasive subdural electrode monitoring at St. Louis Children\u2019s Hospital, 1994-2005. J Neurosurg. 2006;105(5 suppl):343\u2013347.17328255"},{"issue":"8","key":"b28","series-title":"J Clin Neurosci","first-page":"1441","article-title":"Combining stereo-electroencephalography and subdural electrodes in the diagnosis and treatment of medically intractable epilepsy","volume":"21","author":"Enatsu R","year":"2014","unstructured":"Enatsu R, Bulacio J, Najm I,  Combining stereo-electroencephalography and subdural electrodes in the diagnosis and treatment of medically intractable epilepsy. J Clin Neurosci. 2014;21(8):1441\u20131445.24650680"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/138\/3\/article-p821.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/138\/3\/article-p821.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/138\/3\/article-p821.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T08:12:57Z","timestamp":1732176777000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/138\/3\/article-p821.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,1]]},"references-count":28,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2022.5.jns221118","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,1]]}}}