{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T22:00:57Z","timestamp":1770328857462,"version":"3.49.0"},"reference-count":17,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"4","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,4,1]]},"abstract":"<jats:sec>\n<jats:title>OBJECTIVE<\/jats:title>\n<jats:p>Neuronavigation is a useful adjunct for catheter placement during neurosurgical procedures for hydrocephalus or ventricular access. MRI protocols for navigation are lengthy and require sedation for young children. CT involves ionizing radiation. In this study, the authors introduce the clinical application of a 1-minute rapid MRI sequence that does not require sedation in young children and report their preliminary clinical experience using this technique in their pediatric population.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>METHODS<\/jats:title>\n<jats:p>All patients who underwent ventricular catheter placement at a children\u2019s hospital using a rapid noncontrast MRI protocol, standard MRI, or head CT from July 2021 to August 2023 were included. Type of procedure, etiology of hydrocephalus, ventricle configuration and size, morphology of ventricles, need for adjunctive intraoperative ultrasound, duration of procedure, accuracy of catheter placement, and need for proximal revision within 90 days were retrospectively recorded and compared across imaging modalities.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>RESULTS<\/jats:title>\n<jats:p>Sixty-eight patients underwent 83 procedures: 21 underwent CT navigation, 29 standard MRI, and 33 rapid MRI. Patients who received standard MRI more often had tumor etiology, while those who underwent CT and rapid MRI had posthemorrhagic etiology (\u03c7<jats:sup>2<\/jats:sup> = 13.04, p = 0.042). Intraoperative ultrasound was required for 1 patient in the standard MRI group and 1 patient in the CT group. There was no difference in procedure time across groups (p = 0.831). On multivariable analysis, procedure time differed by procedure type, where external ventricular drain placement and proximal revision were faster (p &lt; 0.001 and p &lt; 0.028, respectively). Proximal revision due to obstruction within 90 days occurred in 3 cases (in the same patient with complex loculated hydrocephalus) in the rapid MRI group and 2 cases in the CT group.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>CONCLUSIONS<\/jats:title>\n<jats:p>Although this study was not powered for statistical inference, the authors report on the clinical use of a 1-minute rapid MRI sequence for neuronavigation in hydrocephalus or ventricular access surgery. There were no instances in which intraoperative ultrasound was required as an adjunct for procedures navigated with rapid MRI, and intraoperative time did not differ from that of standard navigation protocols.<\/jats:p>\n<\/jats:sec>","DOI":"10.3171\/2023.11.peds23412","type":"journal-article","created":{"date-parts":[[2024,1,27]],"date-time":"2024-01-27T02:04:34Z","timestamp":1706321074000},"page":"343-348","source":"Crossref","is-referenced-by-count":5,"title":["Rapid brain MRI for image-guided ventricular catheter placement in pediatric patients: protocol and preliminary clinical outcomes"],"prefix":"10.3171","volume":"33","author":[{"given":"Grace Y.","family":"Lai","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Division of Pediatric Neurosurgery, University of Nebraska Medical Center and Children\u2019s Hospital and Medical Center, Omaha, Nebraska;"},{"name":"Department of Neurological Surgery, Division of Pediatric Neurosurgery, UCSF Benioff Children\u2019s Hospitals, University of California, San Francisco, California;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andria","family":"Powers","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Nebraska Medical Center and Children\u2019s Hospital and Medical Center, Omaha, Nebraska; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taylor","family":"Chung","sequence":"additional","affiliation":[{"name":"Department of Radiology and Diagnostic Imaging, Section of Oakland Pediatric Radiology, UCSF Benioff Children\u2019s Hospital, Oakland, California"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter P.","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Division of Pediatric Neurosurgery, UCSF Benioff Children\u2019s Hospitals, University of California, San Francisco, California;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"issue":"1","key":"b1","series-title":"J Neurosurg","first-page":"66","article-title":"Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation","volume":"119","author":"Wilson TJ","year":"2013","unstructured":"Wilson TJ, Stetler WR Jr, Al-Holou WN, Sullivan SE. Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation. J Neurosurg. 2013;119(1):66\u201370."},{"issue":"8","key":"b2","series-title":"Acta Neurochir (Wien)","first-page":"1399","article-title":"Placement accuracy of external ventricular drain when comparing freehand insertion to neuronavigation guidance in severe traumatic brain injury","volume":"159","author":"AlAzri A","year":"2017","unstructured":"AlAzri A, Mok K, Chankowsky J, Mullah M, Marcoux J. Placement accuracy of external ventricular drain when comparing freehand insertion to neuronavigation guidance in severe traumatic brain injury. Acta Neurochir (Wien). 2017;159(8):1399\u20131411."},{"issue":"2","key":"b3","series-title":"J Neurosurg Pediatr","first-page":"112","article-title":"Image-guided cerebrospinal fluid shunting in children: catheter accuracy and shunt survival","volume":"10","author":"Levitt MR","year":"2012","unstructured":"Levitt MR, O\u2019Neill BR, Ishak GE,  Image-guided cerebrospinal fluid shunting in children: catheter accuracy and shunt survival. J Neurosurg Pediatr. 2012;10(2):112\u2013117."},{"issue":"4","key":"b4","series-title":"J Neurosurg Pediatr","first-page":"327","article-title":"Electromagnetic-guided neuronavigation for safe placement of intraventricular catheters in pediatric neurosurgery","volume":"10","author":"Hermann EJ","year":"2012","unstructured":"Hermann EJ, Capelle HH, Tschan CA, Krauss JK. Electromagnetic-guided neuronavigation for safe placement of intraventricular catheters in pediatric neurosurgery. J Neurosurg Pediatr. 2012;10(4):327\u2013333."},{"issue":"2","key":"b5","series-title":"Stereotact Funct Neurosurg","first-page":"75","article-title":"CT-based, fiducial-free frameless stereotaxy for difficult ventriculoperitoneal shunt insertion: experience in 26 consecutive patients","volume":"88","author":"Reig AS","year":"2010","unstructured":"Reig AS, Stevenson CB, Tulipan NB. CT-based, fiducial-free frameless stereotaxy for difficult ventriculoperitoneal shunt insertion: experience in 26 consecutive patients. Stereotact Funct Neurosurg. 2010;88(2):75\u201380."},{"issue":"2","key":"b6","series-title":"J Neurosurg","first-page":"367","article-title":"Development of an ultrafast brain MR neuronavigation protocol for ventricular shunt placement","volume":"138","author":"Vanstrum EB","year":"2022","unstructured":"Vanstrum EB, Borzage MT, Ha J,  Development of an ultrafast brain MR neuronavigation protocol for ventricular shunt placement. J Neurosurg. 2022;138(2):367\u2013373."},{"issue":"9840","key":"b7","series-title":"Lancet","first-page":"499","article-title":"Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study","volume":"380","author":"Pearce MS","year":"2012","unstructured":"Pearce MS, Salotti JA, Little MP,  Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet. 2012;380(9840):499\u2013505."},{"issue":"22","key":"b8","series-title":"N Engl J Med","first-page":"2277","article-title":"Computed tomography\u2014an increasing source of radiation exposure","volume":"357","author":"Brenner DJ","year":"2007","unstructured":"Brenner DJ, Hall EJ. Computed tomography\u2014an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277\u20132284."},{"issue":"4","key":"b9","series-title":"Semin Ultrasound CT MR","first-page":"365","article-title":"Techniques that decrease or eliminate ionizing radiation for evaluation of ventricular shunts in children with hydrocephalus","volume":"35","author":"DeFlorio RM","year":"2014","unstructured":"DeFlorio RM, Shah CC. Techniques that decrease or eliminate ionizing radiation for evaluation of ventricular shunts in children with hydrocephalus. Semin Ultrasound CT MR. 2014;35(4):365\u2013373."},{"issue":"1","key":"b10","series-title":"BMC Pediatr","first-page":"14","article-title":"Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department","volume":"20","author":"Ramgopal S","year":"2020","unstructured":"Ramgopal S, Karim SA, Subramanian S, Furtado AD, Marin JR. Rapid brain MRI protocols reduce head computerized tomography use in the pediatric emergency department. BMC Pediatr. 2020;20(1):14."},{"issue":"4","key":"b11","series-title":"J Neurosurg Pediatr","first-page":"440","article-title":"Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalus","volume":"13","author":"Patel DM","year":"2014","unstructured":"Patel DM, Tubbs RS, Pate G, Johnston JM Jr, Blount JP. Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalus. J Neurosurg Pediatr. 2014;13(4):440\u2013447."},{"issue":"6","key":"b12","series-title":"Pediatr Emerg Care","first-page":"435","article-title":"Radiographic evaluation of pediatric cerebrospinal fluid shunt malfunction in the emergency setting","volume":"31","author":"Boyle TP","year":"2015","unstructured":"Boyle TP, Nigrovic LE. Radiographic evaluation of pediatric cerebrospinal fluid shunt malfunction in the emergency setting. Pediatr Emerg Care. 2015;31(6):435\u2013443."},{"issue":"5","key":"b13","series-title":"Pediatr Radiol","first-page":"724","article-title":"Safety challenges related to the use of sedation and general anesthesia in pediatric patients undergoing magnetic resonance imaging examinations","volume":"51","author":"Artunduaga M","year":"2021","unstructured":"Artunduaga M, Liu CA, Morin CE,  Safety challenges related to the use of sedation and general anesthesia in pediatric patients undergoing magnetic resonance imaging examinations. Pediatr Radiol. 2021;51(5):724\u2013735."},{"issue":"6","key":"b14","series-title":"Radiographics","first-page":"e220147","article-title":"Focused abbreviated survey MRI protocols for brain and spine imaging","volume":"43","author":"Eisenmenger LB","year":"2023","unstructured":"Eisenmenger LB, Peret A, Roberts GS,  Focused abbreviated survey MRI protocols for brain and spine imaging. Radiographics. 2023;43(6):e220147."},{"issue":"8","key":"b15","series-title":"AJNR Am J Neuroradiol","first-page":"E93","article-title":"Rapid-sequence MRI of the brain: a distinct imaging study","volume":"39","author":"Pfeifer CM","year":"2018","unstructured":"Pfeifer CM. Rapid-sequence MRI of the brain: a distinct imaging study. AJNR Am J Neuroradiol. 2018;39(8):E93\u2013E94."},{"issue":"6","key":"b16","series-title":"World Neurosurg","first-page":"e307","article-title":"Rapid sequence magnetic resonance imaging in the assessment of children with hydrocephalus","volume":"80","author":"O\u2019Neill BR","year":"2013","unstructured":"O\u2019Neill BR, Pruthi S, Bains H,  Rapid sequence magnetic resonance imaging in the assessment of children with hydrocephalus. World Neurosurg. 2013;80(6):e307\u2013e312."},{"issue":"4","key":"b17","series-title":"Stereotact Funct Neurosurg","first-page":"188","article-title":"Factors influencing the application accuracy of neuronavigation systems","volume":"75","author":"Steinmeier R","year":"2000","unstructured":"Steinmeier R, Rachinger J, Kaus M, Ganslandt O, Huk W, Fahlbusch R. Factors influencing the application accuracy of neuronavigation systems. Stereotact Funct Neurosurg. 2000;75(4):188\u2013202."}],"container-title":["Journal of Neurosurgery: Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/33\/4\/article-p343.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/33\/4\/article-p343.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/33\/4\/article-p343.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,6]],"date-time":"2024-12-06T13:04:58Z","timestamp":1733490298000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/33\/4\/article-p343.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,1]]},"references-count":17,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3171\/2023.11.peds23412","relation":{},"ISSN":["1933-0707","1933-0715"],"issn-type":[{"value":"1933-0707","type":"print"},{"value":"1933-0715","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,1]]}}}