{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T06:20:55Z","timestamp":1785824455105,"version":"3.56.0"},"reference-count":25,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,9,1]]},"abstract":"<jats:sec>\n<jats:title>OBJECTIVE<\/jats:title>\n<jats:p>Multiple solutions for navigation-guided pedicle screw placement are currently available. Intraoperative imaging techniques are invaluable for spinal surgery, but often there is little attention paid to patient radiation exposure. This study aimed to compare the applied radiation doses of sliding gantry CT (SGCT)\u2013 and mobile cone-beam CT (CBCT)\u2013based pedicle screw placement for spinal instrumentation.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>METHODS<\/jats:title>\n<jats:p>The authors retrospectively analyzed 183 and 54 patients who underwent SGCT- or standard CBCT-based pedicle screw placement, respectively, for spinal instrumentation at their department between June 2019 and January 2020. SGCT uses an automated radiation dose adjustment.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>RESULTS<\/jats:title>\n<jats:p>Baseline characteristics, including the number of screws per patient and the number of instrumented levels, did not significantly differ between the two groups. Although the accuracy of screw placement according to Gertzbein-Robbins classification did not differ between the two groups, more screws had to be revised intraoperatively in the CBCT group (SGCT 2.7% vs CBCT 6.0%, p = 0.0036). Mean (\u00b1 SD) radiation doses for the first (SGCT 484.0 \u00b1 201.1 vs CBCT 687.4 \u00b1 188.5 mGy*cm, p &lt; 0.0001), second (SGCT 515.8 \u00b1 216.3 vs CBCT 658.3 \u00b1 220.1 mGy*cm, p &lt; 0.0001), third (SGCT 531.3 \u00b1 237.5 vs CBCT 641.6 \u00b1 177.3 mGy*cm, p = 0.0140), and total (SGCT 1216.9 \u00b1 699.3 vs CBCT 2000.3 \u00b1 921.0 mGy*cm, p &lt; 0.0001) scans were significantly lower for SGCT. This was also true for radiation doses per scanned level (SGCT 461.9 \u00b1 429.3 vs CBCT 1004.1 \u00b1 905.1 mGy*cm, p &lt; 0.0001) and radiation doses per screw (SGCT 172.6 \u00b1 110.1 vs CBCT 349.6 \u00b1 273.4 mGy*cm, p &lt; 0.0001).<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>CONCLUSIONS<\/jats:title>\n<jats:p>The applied radiation doses were significantly lower using SGCT for navigated pedicle screw placement in spinal instrumentation. A modern CT scanner on a sliding gantry leads to lower radiation doses, especially through automated 3D radiation dose adjustment.<\/jats:p>\n<\/jats:sec>","DOI":"10.3171\/2023.4.spine23174","type":"journal-article","created":{"date-parts":[[2023,6,3]],"date-time":"2023-06-03T16:54:25Z","timestamp":1685811265000},"page":"363-369","source":"Crossref","is-referenced-by-count":6,"title":["Radiation doses and accuracy of navigated pedicle screw placement in cervical and thoracic spine surgery: a comparison of sliding gantry CT and mobile cone-beam CT in a homogeneous cohort"],"prefix":"10.3171","volume":"39","author":[{"given":"Lea","family":"Baumgart","sequence":"first","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Ille","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"},{"name":"TUM Neuroimaging Center, Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan S.","family":"Kirschke","sequence":"additional","affiliation":[{"name":"Neuroradiology, and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Meyer","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandro M.","family":"Krieg","sequence":"additional","affiliation":[{"name":"Departments of Neurosurgery and"},{"name":"TUM Neuroimaging Center, Technical University of Munich, School of Medicine, Klinikum rechts der Isar, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"1","key":"b1","series-title":"J Spine Surg","first-page":"155","article-title":"What should my hospital buy next? Guidelines for the acquisition and application of imaging, navigation, and robotics for spine surgery","volume":"5","author":"Malham GM","year":"2019","unstructured":"Malham GM, Wells-Quinn T. What should my hospital buy next? Guidelines for the acquisition and application of imaging, navigation, and robotics for spine surgery. J Spine Surg. 2019;5(1):155\u2013165."},{"issue":"2","key":"b2","series-title":"Eur Spine J","first-page":"247","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"Gelalis ID","year":"2012","unstructured":"Gelalis ID, Paschos NK, Pakos EE,  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J. 2012;21(2):247\u2013255."},{"key":"b3","series-title":"World Neurosurg","first-page":"e169","article-title":"Pedicle screw placement using intraoperative computed tomography and computer-aided spinal navigation improves screw accuracy and avoids postoperative revisions: single-center analysis of 1400 pedicle screws","volume":"160","author":"Hagan MJ","year":"2022","unstructured":"Hagan MJ, Syed S, Leary OP,  Pedicle screw placement using intraoperative computed tomography and computer-aided spinal navigation improves screw accuracy and avoids postoperative revisions: single-center analysis of 1400 pedicle screws. World Neurosurg. 2022;160:e169\u2013e179."},{"key":"b4","series-title":"World Neurosurg","first-page":"e175","article-title":"Prospective comparative study in spine surgery between O-arm and Airo systems: efficacy and radiation exposure","volume":"118","author":"Farah K","year":"2018","unstructured":"Farah K, Coudert P, Graillon T,  Prospective comparative study in spine surgery between O-arm and Airo systems: efficacy and radiation exposure. World Neurosurg. 2018;118:e175\u2013e184."},{"issue":"12","key":"b5","series-title":"Eur Spine J","first-page":"3720","article-title":"Clinical efficiency of operating room-based sliding gantry CT as compared to mobile cone-beam CT-based navigated pedicle screw placement in 853 patients and 6733 screws","volume":"30","author":"Ille S","year":"2021","unstructured":"Ille S, Baumgart L, Obermueller T, Meyer B, Krieg SM. Clinical efficiency of operating room-based sliding gantry CT as compared to mobile cone-beam CT-based navigated pedicle screw placement in 853 patients and 6733 screws. Eur Spine J. 2021;30(12):3720\u20133730."},{"issue":"3","key":"b6","series-title":"Neurosurg Rev","first-page":"385","article-title":"Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis","volume":"39","author":"Meng XT","year":"2016","unstructured":"Meng XT, Guan XF, Zhang HL, He SS. Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis. Neurosurg Rev. 2016;39(3):385\u2013391."},{"issue":"2","key":"b7","series-title":"Int J CARS","first-page":"397","article-title":"Dual-room CT with a sliding gantry for intraoperative imaging: feasibility and workflow analysis of an interdisciplinary concept","volume":"14","author":"Lenski M","year":"2019","unstructured":"Lenski M, Hofereiter J, Terpolilli N,  Dual-room CT with a sliding gantry for intraoperative imaging: feasibility and workflow analysis of an interdisciplinary concept. Int J CARS. 2019;14(2):397\u2013407."},{"issue":"1","key":"b8","series-title":"Eur Spine J","first-page":"50","article-title":"Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine","volume":"13","author":"Richter M","year":"2004","unstructured":"Richter M, Mattes T, Cakir B. Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine. Eur Spine J. 2004;13(1):50\u201359."},{"issue":"20","key":"b9","series-title":"Spine (Phila Pa 1976)","first-page":"2280","article-title":"Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws","volume":"30","author":"Richter M","year":"2005","unstructured":"Richter M, Cakir B, Schmidt R. Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976). 2005;30(20):2280\u20132287."},{"issue":"3","key":"b10","series-title":"Neurosurg Focus","first-page":"E7","article-title":"Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned","volume":"36","author":"Rivkin MA","year":"2014","unstructured":"Rivkin MA, Yocom SS. Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned. Neurosurg Focus. 2014;36(3):E7."},{"issue":"3","key":"b11","series-title":"Eur Spine J","first-page":"654","article-title":"CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws","volume":"22","author":"Waschke A","year":"2013","unstructured":"Waschke A, Walter J, Duenisch P, Reichart R, Kalff R, Ewald C. CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws. Eur Spine J. 2013;22(3):654\u2013660."},{"issue":"26","key":"b12","series-title":"Spine (Phila Pa 1976)","first-page":"2919","article-title":"Intraoperative computed tomography with integrated navigation system in spinal stabilizations","volume":"34","author":"Zausinger S","year":"2009","unstructured":"Zausinger S, Scheder B, Uhl E, Heigl T, Morhard D, Tonn JC. Intraoperative computed tomography with integrated navigation system in spinal stabilizations. Spine (Phila Pa 1976). 2009;34(26):2919\u20132926."},{"issue":"3","key":"b13","series-title":"Eur Spine J","first-page":"235","article-title":"Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients","volume":"9","author":"Laine T","year":"2000","unstructured":"Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J. 2000;9(3):235\u2013240."},{"issue":"5","key":"b14","series-title":"Spine (Phila Pa 1976)","first-page":"370","article-title":"Intraoperative computed tomography versus 3D C-arm imaging for navigated spinal instrumentation","volume":"43","author":"Hecht N","year":"2018","unstructured":"Hecht N, Yassin H, Czabanka M,  Intraoperative computed tomography versus 3D C-arm imaging for navigated spinal instrumentation. Spine (Phila Pa 1976). 2018;43(5):370\u2013377."},{"issue":"3","key":"b15","series-title":"Spine (Phila Pa 1976)","first-page":"E111","article-title":"Pedicle screw placement accuracy: a meta-analysis","volume":"32","author":"Kosmopoulos V","year":"2007","unstructured":"Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976). 2007;32(3):E111\u2013E120."},{"issue":"1-2","key":"b16","series-title":"ANZ J Surg","first-page":"51","article-title":"What we know about intra-operative radiation exposure and hazards to operating theatre staff: a systematic review","volume":"92","author":"Gogos S","year":"2022","unstructured":"Gogos S, Touzell A, Lerner LB. What we know about intra-operative radiation exposure and hazards to operating theatre staff: a systematic review. ANZ J Surg. 2022;92(1-2):51\u201356."},{"issue":"2","key":"b17","series-title":"World Neurosurg","first-page":"390","article-title":"Use of CT-based intraoperative spinal navigation: management of radiation exposure to operator, staff, and patients","volume":"79","author":"Bandela JR","year":"2013","unstructured":"Bandela JR, Jacob RP, Arreola M, Griglock TM, Bova F, Yang M. Use of CT-based intraoperative spinal navigation: management of radiation exposure to operator, staff, and patients. World Neurosurg. 2013;79(2):390\u2013394."},{"issue":"4","key":"b18","series-title":"J Neurosurg Spine","first-page":"397","article-title":"Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients","volume":"29","author":"Scarone P","year":"2018","unstructured":"Scarone P, Vincenzo G, Distefano D,  Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients. J Neurosurg Spine. 2018;29(4):397\u2013406."},{"issue":"8","key":"b19","series-title":"Spine J","first-page":"1243","article-title":"Radiation protection measures to reduce the eye lens dose in spinal surgery","volume":"21","author":"Klingler JH","year":"2021","unstructured":"Klingler JH, Hoedlmoser H, Naseri Y. Radiation protection measures to reduce the eye lens dose in spinal surgery. Spine J. 2021;21(8):1243\u20131245."},{"issue":"1","key":"b20","series-title":"Spine (Phila Pa 1976)","first-page":"11","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein SDRS","year":"1990","unstructured":"Gertzbein SDRS, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976). 1990;15(1):11\u201314."},{"issue":"13","key":"b21","series-title":"Spine (Phila Pa 1976)","first-page":"1004","article-title":"Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques","volume":"39","author":"Villard J","year":"2014","unstructured":"Villard J, Ryang YM, Demetriades AK,  Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques. Spine (Phila Pa 1976). 2014;39(13):1004\u20131009."},{"issue":"7","key":"b22","series-title":"Orthop Traumatol Surg Res","first-page":"102795","article-title":"Minimising radiation exposure to the surgeon in minimally invasive spine surgeries: a systematic review of 15 studies","volume":"107","author":"Arif S","year":"2021","unstructured":"Arif S, Brady Z, Enchev Y, Peev N, Encheva E. Minimising radiation exposure to the surgeon in minimally invasive spine surgeries: a systematic review of 15 studies. Orthop Traumatol Surg Res. 2021;107(7):102795."},{"issue":"5 suppl 2","key":"b23","series-title":"Neurosurgery","first-page":"231","article-title":"Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite","volume":"64","author":"Uhl E","year":"2009","unstructured":"Uhl E, Zausinger S, Morhard D,  Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite. Neurosurgery. 2009;64(5 suppl 2):231\u2013240."},{"issue":"3","key":"b24","series-title":"Neurosurg Focus","first-page":"E11","article-title":"Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery","volume":"28","author":"Tormenti MJ","year":"2010","unstructured":"Tormenti MJ, Kostov DB, Gardner PA, Kanter AS, Spiro RM, Okonkwo DO. Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery. Neurosurg Focus. 2010;28(3):E11."},{"issue":"5","key":"b25","series-title":"Int J Spine Surg","first-page":"909","article-title":"Computed tomography intraoperative navigation in spinal surgery: assessment of patient radiation exposure in current practices","volume":"16","author":"Bourret S","year":"2022","unstructured":"Bourret S, Cloche T, Boue L, Thompson W, Dubois T, Le Huec JC. Computed tomography intraoperative navigation in spinal surgery: assessment of patient radiation exposure in current practices. Int J Spine Surg. 2022;16(5):909\u2013915."}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/39\/3\/article-p363.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/39\/3\/article-p363.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/39\/3\/article-p363.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,6]],"date-time":"2024-12-06T13:13:27Z","timestamp":1733490807000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/39\/3\/article-p363.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,1]]},"references-count":25,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/2023.4.spine23174","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2023,9,1]]}}}