{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T06:44:31Z","timestamp":1780469071809,"version":"3.54.1"},"reference-count":19,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,11,1]]},"abstract":"<jats:sec>\n<jats:title>OBJECTIVE<\/jats:title>\n<jats:p>One consideration in pediatric stereoencephalography (SEEG) is decreased skull thicknesses compared with adults, which may limit traditional bolt-based anchoring of electrodes. The authors aimed to investigate the safety profile, complication rates, and technical adaptations of placing SEEG electrodes in pediatric patients.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>METHODS<\/jats:title>\n<jats:p>The authors retrospectively reviewed all patients aged 12 years or younger at the time of SEEG implantation at their institution. Postimplantation CT scans were used to measure skull thickness at the entry point of each SEEG lead. Postimplantation lead accuracy was also assessed.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>RESULTS<\/jats:title>\n<jats:p>Fifty-three patients were reviewed. The median skull thickness was 4.1 (interquartile range [IQR] 3.15\u20135.2) mm. There were 5 total complications: 1 retained bolt fragment, 3 asymptomatic subdural hematomas, and 1 asymptomatic intracranial hemorrhage. Median radial error from the lead target was 3.5 (IQR 2.24\u20135.25) mm. Linear regression analysis revealed that increasing skull thickness decreased the deviation from the intended target, implying an improved accuracy to target at thicker skull entry points; this trended towards improved accuracy, but did not achieve statistical significance (p = 0.54).<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>CONCLUSIONS<\/jats:title>\n<jats:p>This study found a 1.9% hardware complication rate and a 9.4% asymptomatic hemorrhage rate. Suturing electrodes to the scalp may represent a reasonable option if there are concerns of young age or a thin skull. These data indicate that invasive SEEG evaluation is safe among patients 12 years old or younger.<\/jats:p>\n<\/jats:sec>","DOI":"10.3171\/2023.6.peds2351","type":"journal-article","created":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T05:17:54Z","timestamp":1691817474000},"page":"562-568","source":"Crossref","is-referenced-by-count":6,"title":["The impact of skull thickness on pediatric stereoencephalography electrode implantation and technical considerations"],"prefix":"10.3171","volume":"32","author":[{"given":"Ansh","family":"Desai","sequence":"first","affiliation":[{"name":"Case Western Reserve University School of Medicine, Cleveland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akshay","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cleveland Clinic, Cleveland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Swetha J.","family":"Sundar","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cleveland Clinic, Cleveland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason K.","family":"Hsieh","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cleveland Clinic, Cleveland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Efstathios","family":"Kondylis","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cleveland Clinic, Cleveland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arpan","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cleveland Clinic, Cleveland; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Bulacio","sequence":"additional","affiliation":[{"name":"Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajay","family":"Gupta","sequence":"additional","affiliation":[{"name":"Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lara","family":"Jehi","sequence":"additional","affiliation":[{"name":"Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Bingaman","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Cleveland Clinic, Cleveland; and"},{"name":"Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"7","key":"b1","series-title":"Epilepsia","first-page":"1131","article-title":"Defining epileptogenic networks: contribution of SEEG and signal analysis","volume":"58","author":"Bartolomei F","year":"2017","unstructured":"Bartolomei F, Lagarde S, Wendling F,  Defining epileptogenic networks: contribution of SEEG and signal analysis. Epilepsia. 2017;58(7):1131\u20131147."},{"issue":"11","key":"b2","series-title":"Epilepsia","first-page":"1735","article-title":"Diagnostic utility of invasive EEG for epilepsy surgery: indications, modalities, and techniques","volume":"57","author":"Jayakar P","year":"2016","unstructured":"Jayakar P, Gotman J, Harvey AS,  Diagnostic utility of invasive EEG for epilepsy surgery: indications, modalities, and techniques. Epilepsia. 2016;57(11):1735\u20131747."},{"issue":"3","key":"b3","series-title":"Epilepsia","first-page":"386","article-title":"Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications","volume":"57","author":"Mullin JP","year":"2016","unstructured":"Mullin JP, Shriver M, Alomar S,  Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications. Epilepsia. 2016;57(3):386\u2013401."},{"issue":"13","key":"b4","series-title":"Spine (Phila Pa 1976)","first-page":"1451","article-title":"Osteology of the pediatric skull. Considerations of halo pin placement","volume":"19","author":"Wong WB","year":"1994","unstructured":"Wong WB, Haynes RJ. Osteology of the pediatric skull. Considerations of halo pin placement. Spine (Phila Pa 1976). 1994;19(13):1451\u20131454."},{"key":"b5","series-title":"Epilepsy Res","first-page":"106765","article-title":"Stereo-electroencephalography (SEEG) in pediatric epilepsy: utility in children with and without prior epilepsy surgery failure","volume":"177","author":"Hyslop A","year":"2021","unstructured":"Hyslop A, Wang S, Bryant JP,  Stereo-electroencephalography (SEEG) in pediatric epilepsy: utility in children with and without prior epilepsy surgery failure. Epilepsy Res. 2021;177:106765."},{"issue":"9","key":"b6","series-title":"Laryngoscope","first-page":"1730","article-title":"Anatomical considerations for endoscopic endonasal skull base surgery in pediatric patients","volume":"120","author":"Tatreau JR","year":"2010","unstructured":"Tatreau JR, Patel MR, Shah RN,  Anatomical considerations for endoscopic endonasal skull base surgery in pediatric patients. Laryngoscope. 2010;120(9):1730\u20131737."},{"issue":"6","key":"b7","series-title":"Am J Otolaryngol","first-page":"690","article-title":"Safety of cranial fixation in endoscopic brow lifts","volume":"34","author":"Harirchian S","year":"2013","unstructured":"Harirchian S, Kuperan AB, Shah AR. Safety of cranial fixation in endoscopic brow lifts. Am J Otolaryngol. 2013;34(6):690\u2013694."},{"issue":"2","key":"b8","series-title":"Eur Spine J","first-page":"410","article-title":"Analysis of skull bone thickness during growth: an anatomical guide for safe pin placement in halo fixation","volume":"30","author":"Domenech-Fernandez P","year":"2021","unstructured":"Domenech-Fernandez P, Yamane J, Domenech J,  Analysis of skull bone thickness during growth: an anatomical guide for safe pin placement in halo fixation. Eur Spine J. 2021;30(2):410\u2013415."},{"issue":"5","key":"b9","series-title":"J Dermatolog Treat","first-page":"2702","article-title":"DISCERN scores of morphea information on YouTube","volume":"33","author":"Rao EM","year":"2022","unstructured":"Rao EM, Smith GP. DISCERN scores of morphea information on YouTube. J Dermatolog Treat. 2022;33(5):2702\u20132704."},{"issue":"2","key":"b10","series-title":"J Chiropr Med","first-page":"155","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo TK","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u2013163."},{"issue":"3","key":"b11","series-title":"Neurosurgery","first-page":"E281","article-title":"Incorporating new technology into a surgical technique: the learning curve of a single surgeon\u2019s stereo-electroencephalography experience","volume":"86","author":"McGovern RA","year":"2020","unstructured":"McGovern RA, Butler RS, Bena J, Gonzalez-Martinez J. Incorporating new technology into a surgical technique: the learning curve of a single surgeon\u2019s stereo-electroencephalography experience. Neurosurgery. 2020;86(3):E281\u2013E289."},{"issue":"3","key":"b12","series-title":"Epilepsia","first-page":"571","article-title":"Risk analysis of hemorrhage in stereo-electroencephalography procedures","volume":"60","author":"McGovern RA","year":"2019","unstructured":"McGovern RA, Ruggieri P, Bulacio J, Najm I, Bingaman WE, Gonzalez-Martinez JA. Risk analysis of hemorrhage in stereo-electroencephalography procedures. Epilepsia. 2019;60(3):571\u2013580."},{"issue":"1","key":"b13","series-title":"J Neurosurg Pediatr","first-page":"37","article-title":"Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique","volume":"22","author":"Abel TJ","year":"2018","unstructured":"Abel TJ, Varela Osorio R, Amorim-Leite R,  Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique. J Neurosurg Pediatr. 2018;22(1):37\u201346."},{"key":"b14","series-title":"Epilepsy Res","first-page":"106758","article-title":"Comparison of subdural grid and stereoelectroencephalography in a cohort of pediatric patients","volume":"177","author":"Talai A","year":"2021","unstructured":"Talai A, Eschbach K, Stence NV,  Comparison of subdural grid and stereoelectroencephalography in a cohort of pediatric patients. Epilepsy Res. 2021;177:106758."},{"issue":"Pt A","key":"b15","series-title":"Epilepsy Behav","first-page":"106905","article-title":"Postoperative outcomes following pediatric intracranial electrode monitoring: a case for stereoelectroencephalography (SEEG)","volume":"104","author":"Kim LH","year":"2020","unstructured":"Kim LH, Parker JJ, Ho AL,  Postoperative outcomes following pediatric intracranial electrode monitoring: a case for stereoelectroencephalography (SEEG). Epilepsy Behav. 2020;104(Pt A):106905."},{"issue":"2","key":"b16","series-title":"J Neuroimaging","first-page":"139","article-title":"The thickness of the temporal squama and its implication for transcranial sonography","volume":"14","author":"Jarquin-Valdivia AA","year":"2004","unstructured":"Jarquin-Valdivia AA, McCartney J, Palestrant D, Johnston SC, Gress D. The thickness of the temporal squama and its implication for transcranial sonography. J Neuroimaging. 2004;14(2):139\u2013142."},{"key":"b17","series-title":"Epilepsy Behav Rep","first-page":"100394","article-title":"Feasibility of stereo electroencephalogram (SEEG) with little to no scalp bone; a case report","volume":"15","author":"Wabulya A","year":"2020","unstructured":"Wabulya A, Nacionales D, Shin HW, Abumoussa A, Hadar E. Feasibility of stereo electroencephalogram (SEEG) with little to no scalp bone; a case report. Epilepsy Behav Rep. 2020;15:100394."},{"issue":"3","key":"b18","series-title":"J Neurosurg Pediatr","first-page":"253","article-title":"Placement of leads for stereotactic electroencephalography without the use of anchor bolts: technical note","volume":"27","author":"Karsonovich T","year":"2020","unstructured":"Karsonovich T, Alexander A, Graber S, O\u2019Neill BR. Placement of leads for stereotactic electroencephalography without the use of anchor bolts: technical note. J Neurosurg Pediatr. 2020;27(3):253\u2013258."},{"key":"b19","series-title":"Proc SPIE Int Soc Opt Eng","first-page":"105720O","article-title":"Cranial thickness changes in early childhood","volume":"10572","author":"Gajawelli N","year":"2017","unstructured":"Gajawelli N, Deoni S, Shi J,  Cranial thickness changes in early childhood. Proc SPIE Int Soc Opt Eng. 2017;10572:105720O."}],"container-title":["Journal of Neurosurgery: Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/32\/5\/article-p562.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/32\/5\/article-p562.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/32\/5\/article-p562.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,6]],"date-time":"2024-12-06T13:00:05Z","timestamp":1733490005000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/32\/5\/article-p562.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,1]]},"references-count":19,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.3171\/2023.6.peds2351","relation":{},"ISSN":["1933-0707","1933-0715"],"issn-type":[{"value":"1933-0707","type":"print"},{"value":"1933-0715","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,1]]}}}