{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T00:08:07Z","timestamp":1793232487521,"version":"4.5.0"},"reference-count":75,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,1]]},"abstract":"<jats:sec>\n<jats:title>OBJECTIVE<\/jats:title>\n<jats:p>Deep brain stimulation (DBS) is an effective treatment for medically refractory movement disorders and other neurological conditions. To comprehensively characterize the prevalence, locations, timing of detection, clinical effects, and risk factors of DBS-related intracranial hemorrhage (ICH), the authors performed a systematic review of the published literature.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>METHODS<\/jats:title>\n<jats:p>PubMed, EMBASE, and Web of Science were searched using 2 concepts: cerebral hemorrhage and brain stimulation, with filters for English, human studies, and publication dates 1980\u20132023. The inclusion criteria were the use of DBS intervention for any human neurological condition, with documentation of hemorrhagic complications by location and clinical effect. Studies with non-DBS interventions, no documentation of hemorrhage outcome, patient cohorts of \u2264 10, and pediatric patients were excluded. The risk of bias was assessed using Centre for Evidence-Based Medicine Levels of Evidence. The authors performed proportional meta-analysis for ICH prevalence.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>RESULTS<\/jats:title>\n<jats:p>A total of 63 studies, with 13,056 patients, met the inclusion criteria. The prevalence of ICH was 2.9% (fixed-effects model, 95% CI 2.62%\u20133.2%) per patient and 1.6% (random-effects model, 95% CI 1.34%\u20131.87%) per DBS lead, with 49.6% being symptomatic. The ICH rates did not change with time. ICH most commonly occurred around the DBS lead, with 16% at the entry point, 31% along the track, and 7% at the target. Microelectrode recording (MER) during DBS was associated with increased ICH rate compared to DBS without MER (3.5 \u00b1 2.2 vs 2.1 \u00b1 1.4; p[T \u2264 t] 1-tail = 0.038). Other reported ICH risk factors include intraoperative systolic blood pressure &gt; 140 mm Hg, sulcal DBS trajectories, and multiple microelectrode insertions. Sixty percent of ICH was detected at 24 hours postoperatively and 27% intraoperatively. The all-cause mortality rate of DBS was 0.4%, with ICH accounting for 22% of deaths. Single-surgeon DBS experience showed a weak inverse correlation (r = \u22120.27, p = 0.2189) between the rate of ICH per lead and the number of leads implanted per year.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>CONCLUSIONS<\/jats:title>\n<jats:p>This study provides level III evidence that MER during DBS is a risk factor for ICH. Other risk factors include intraoperative systolic blood pressure &gt; 140 mm Hg, sulcal trajectories, and multiple microelectrode insertions. Avoidance of these risk factors may decrease the rate of ICH.<\/jats:p>\n<\/jats:sec>","DOI":"10.3171\/2024.1.jns232385","type":"journal-article","created":{"date-parts":[[2024,3,23]],"date-time":"2024-03-23T01:30:51Z","timestamp":1711157451000},"page":"381-393","source":"Crossref","is-referenced-by-count":26,"title":["Comprehensive characterization of intracranial hemorrhage in deep brain stimulation: a systematic review of literature from 1987 to 2023"],"prefix":"10.3171","volume":"141","author":[{"given":"Cletus","family":"Cheyuo","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Lahey Hospital and Medical Center, Burlington, Massachusetts;"},{"name":"Division of Neurosurgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Artur","family":"Vetkas","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada;"},{"name":"Department of Neurosurgery, Neurology Clinic, Tartu University Hospital, University of Tartu, Estonia; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Can","family":"Sarica","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suneil K.","family":"Kalia","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada;"},{"name":"Krembil Research Institute, Toronto, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mojgan","family":"Hodaie","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada;"},{"name":"Krembil Research Institute, Toronto, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andres M.","family":"Lozano","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada;"},{"name":"Krembil Research Institute, Toronto, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"3","key":"b1","series-title":"Mov Disord","first-page":"343","article-title":"Deep brain stimulation for Parkinson\u2019s disease: prevalence of adverse events and need for standardized reporting","volume":"23","author":"Videnovic A","year":"2008","unstructured":"Videnovic A, Metman LV. Deep brain stimulation for Parkinson\u2019s disease: prevalence of adverse events and need for standardized reporting. Mov Disord. 2008;23(3):343\u2013349."},{"issue":"5","key":"b2","series-title":"Oper Neurosurg (Hagerstown)","first-page":"277","article-title":"Estimating the risk of deep brain stimulation in the modern era: 2008 to 2020","volume":"21","author":"Koh EJ","year":"2021","unstructured":"Koh EJ, Golubovsky JL, Rammo R,  Estimating the risk of deep brain stimulation in the modern era: 2008 to 2020. Oper Neurosurg (Hagerstown). 2021;21(5):277\u2013290."},{"issue":"1","key":"b3","series-title":"J Neurosurg","first-page":"84","article-title":"Reducing hemorrhagic complications in functional neurosurgery: a large case series and systematic literature review","volume":"116","author":"Zrinzo L","year":"2012","unstructured":"Zrinzo L, Foltynie T, Limousin P, Hariz MI. Reducing hemorrhagic complications in functional neurosurgery: a large case series and systematic literature review. J Neurosurg. 2012;116(1):84\u201394."},{"issue":"2","key":"b4","series-title":"Oper Neurosurg (Hagerstown)","first-page":"e108","article-title":"Are transventricular approaches associated with increased hemorrhage? A comparative study in a series of 624 deep brain stimulation surgeries","volume":"23","author":"Runge J","year":"2022","unstructured":"Runge J, Nagel JM, Cassini Ascencao L,  Are transventricular approaches associated with increased hemorrhage? A comparative study in a series of 624 deep brain stimulation surgeries. Oper Neurosurg (Hagerstown). 2022;23(2):e108\u2013e113."},{"issue":"2","key":"b5","series-title":"J Neurosurg","first-page":"201","article-title":"Sulcal and ventricular trajectories in stereotactic surgery","volume":"110","author":"Elias WJ","year":"2009","unstructured":"Elias WJ, Sansur CA, Frysinger RC. Sulcal and ventricular trajectories in stereotactic surgery. J Neurosurg. 2009;110(2):201\u2013207."},{"issue":"7","key":"b6","series-title":"PLoS Med","first-page":"e1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"6","author":"Moher D","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097."},{"issue":"3","key":"b7","series-title":"J Neurosurg","first-page":"699","article-title":"Asleep deep brain stimulation with intraoperative magnetic resonance guidance: a single-institution experience","volume":"136","author":"Segar DJ","year":"2022","unstructured":"Segar DJ, Tata N, Harary M, Hayes MT, Cosgrove GR. Asleep deep brain stimulation with intraoperative magnetic resonance guidance: a single-institution experience. J Neurosurg. 2022;136(3):699\u2013708."},{"issue":"2","key":"b8","series-title":"Acta Neurochir (Wien)","first-page":"587","article-title":"The risk factors of intracerebral hemorrhage in deep brain stimulation: does target matter?","volume":"164","author":"Shin HK","year":"2022","unstructured":"Shin HK, Kim MS, Yoon HH, Chung SJ, Jeon SR. The risk factors of intracerebral hemorrhage in deep brain stimulation: does target matter? Acta Neurochir (Wien). 2022;164(2):587\u2013598."},{"issue":"4","key":"b9","series-title":"Turk Neurosurg","first-page":"578","article-title":"Surgical-related and hardware-related adverse effects of deep brain stimulation: a retrospective single-center analysis","volume":"32","author":"Erdem NS","year":"2022","unstructured":"Erdem NS, Ozkaynak SS, Cakin H, Ucar T. Surgical-related and hardware-related adverse effects of deep brain stimulation: a retrospective single-center analysis. Turk Neurosurg. 2022;32(4):578\u2013586."},{"key":"b10","series-title":"Front Aging Neurosci","first-page":"819730","article-title":"Complications after deep brain stimulation: a 21-year experience in 426 patients","volume":"14","author":"Jung IH","year":"2022","unstructured":"Jung IH, Chang KW, Park SH, Chang WS, Jung HH, Chang JW. Complications after deep brain stimulation: a 21-year experience in 426 patients. Front Aging Neurosci. 2022;14:819730."},{"key":"b11","series-title":"World Neurosurg","first-page":"e320","article-title":"Safety of deep brain stimulation lead placement on patients requiring anticlotting therapies","volume":"145","author":"Topp G","year":"2021","unstructured":"Topp G, Ghulam-Jelani Z, Chockalingam A,  Safety of deep brain stimulation lead placement on patients requiring anticlotting therapies. World Neurosurg. 2021;145:e320\u2013e325."},{"issue":"6","key":"b12","series-title":"Neuromodulation","first-page":"895","article-title":"Surgical and hardware complications of deep brain stimulation-a single surgeon experience of 519 cases over 20 years","volume":"25","author":"Doshi PK","year":"2022","unstructured":"Doshi PK, Rai N, Das D. Surgical and hardware complications of deep brain stimulation-a single surgeon experience of 519 cases over 20 years. Neuromodulation. 2022;25(6):895\u2013903."},{"issue":"3","key":"b13","series-title":"Oper Neurosurg (Hagerstown)","first-page":"234","article-title":"Bilateral subthalamic nucleus deep brain stimulation in elderly patients with Parkinson disease: a case-control study","volume":"19","author":"Mitchell KT","year":"2020","unstructured":"Mitchell KT, Younce JR, Norris SA,  Bilateral subthalamic nucleus deep brain stimulation in elderly patients with Parkinson disease: a case-control study. Oper Neurosurg (Hagerstown). 2020;19(3):234\u2013240."},{"key":"b14","series-title":"World Neurosurg","first-page":"e1008","article-title":"Safety of noncontrast imaging-guided deep brain stimulation electrode placement in Parkinson disease","volume":"134","author":"Cordeiro JG","year":"2020","unstructured":"Cordeiro JG, Diaz A, Davis JK,  Safety of noncontrast imaging-guided deep brain stimulation electrode placement in Parkinson disease. World Neurosurg. 2020;134:e1008\u2013e1014."},{"key":"b15","series-title":"SAGE Open Med","first-page":"2050312120913458","article-title":"Surgical management of adverse events associated with deep brain stimulation: a single-center experience","volume":"8","author":"Nonaka M","year":"2020","unstructured":"Nonaka M, Morishita T, Yamada K,  Surgical management of adverse events associated with deep brain stimulation: a single-center experience. SAGE Open Med. 2020;8:2050312120913458."},{"issue":"3","key":"b16","series-title":"Stereotact Funct Neurosurg","first-page":"176","article-title":"Screening for platelet dysfunction and use of prophylactic tranexamic acid in patients undergoing deep brain stimulation: a retrospective analysis of incidence and outcome of intracranial hemorrhage","volume":"98","author":"Helmers AK","year":"2020","unstructured":"Helmers AK, Kubelt C, Birkenfeld F,  Screening for platelet dysfunction and use of prophylactic tranexamic acid in patients undergoing deep brain stimulation: a retrospective analysis of incidence and outcome of intracranial hemorrhage. Stereotact Funct Neurosurg. 2020;98(3):176\u2013181."},{"issue":"5","key":"b17","series-title":"J Int Med Res","first-page":"300060519856747","article-title":"Intracranial hemorrhage risk factors of deep brain stimulation for Parkinson\u2019s disease: a 2-year follow-up study","volume":"48","author":"Yang C","year":"2020","unstructured":"Yang C, Qiu Y, Wang J, Wu Y, Hu X, Wu X. Intracranial hemorrhage risk factors of deep brain stimulation for Parkinson\u2019s disease: a 2-year follow-up study. J Int Med Res. 2020;48(5):300060519856747."},{"key":"b18","series-title":"J Clin Neurosci","first-page":"88","article-title":"Pre-operative smoking history increases risk of infection in deep brain stimulation surgery","volume":"69","author":"Farrokhi FR","year":"2019","unstructured":"Farrokhi FR, Marsans MT, Sikora M,  Pre-operative smoking history increases risk of infection in deep brain stimulation surgery. J Clin Neurosci. 2019;69:88\u201392."},{"issue":"1","key":"b19","series-title":"BMC Neurol","first-page":"137","article-title":"Deep brain stimulation for dystonia in Finland during 2007-2016","volume":"19","author":"Ortiz RM","year":"2019","unstructured":"Ortiz RM, Scheperjans F, Pekkonen E. Deep brain stimulation for dystonia in Finland during 2007-2016. BMC Neurol. 2019;19(1):137."},{"key":"b20","series-title":"J Neurol Sci","first-page":"97","article-title":"Hemorrhagic complications seen on immediate intraprocedural stereotactic computed tomography imaging during deep brain stimulation implantation","volume":"400","author":"Sobstyl M","year":"2019","unstructured":"Sobstyl M, Aleksandrowicz M, Z\u0105bek M, Pasterski T. Hemorrhagic complications seen on immediate intraprocedural stereotactic computed tomography imaging during deep brain stimulation implantation. J Neurol Sci. 2019;400:97\u2013103."},{"key":"b21","series-title":"World Neurosurg","first-page":"e801","article-title":"Intraoperative stereotactic magnetic resonance imaging for deep brain stimulation electrode planning in patients with movement disorders","volume":"119","author":"Jakobs M","year":"2018","unstructured":"Jakobs M, Krasniqi E, Klo\u00df M,  Intraoperative stereotactic magnetic resonance imaging for deep brain stimulation electrode planning in patients with movement disorders. World Neurosurg. 2018;119:e801\u2013e808."},{"issue":"11","key":"b22","series-title":"Neuroradiology","first-page":"1151","article-title":"Combination of CT angiography and MRI in surgical planning of deep brain stimulation","volume":"60","author":"Kr\u00fcger MT","year":"2018","unstructured":"Kr\u00fcger MT, Coenen VA, Jenkner C, Urbach H, Egger K, Reinacher PC. Combination of CT angiography and MRI in surgical planning of deep brain stimulation. Neuroradiology. 2018;60(11):1151\u20131158."},{"key":"b23","series-title":"Clin Neurol Neurosurg","first-page":"182","article-title":"Bilateral subthalamic deep brain stimulation is an effective and safe treatment option for the older patients with Parkinson\u2019s disease","volume":"173","author":"Kim M","year":"2018","unstructured":"Kim M, Cho KR, Park JH,  Bilateral subthalamic deep brain stimulation is an effective and safe treatment option for the older patients with Parkinson\u2019s disease. Clin Neurol Neurosurg. 2018;173:182\u2013186."},{"issue":"3","key":"b24","series-title":"JAMA Neurol","first-page":"353","article-title":"Efficacy and safety of deep brain stimulation in Tourette syndrome: the International Tourette Syndrome Deep Brain Stimulation Public Database and Registry","volume":"75","author":"Martinez-Ramirez D","year":"2018","unstructured":"Martinez-Ramirez D, Jimenez-Shahed J, Leckman JF,  Efficacy and safety of deep brain stimulation in Tourette syndrome: the International Tourette Syndrome Deep Brain Stimulation Public Database and Registry. JAMA Neurol. 2018;75(3):353\u2013359."},{"key":"b25","series-title":"Neuroimage Clin","first-page":"580","article-title":"Tractography-assisted deep brain stimulation of the superolateral branch of the medial forebrain bundle (slMFB DBS) in major depression","volume":"20","author":"Coenen VA","year":"2018","unstructured":"Coenen VA, Sajonz B, Reisert M,  Tractography-assisted deep brain stimulation of the superolateral branch of the medial forebrain bundle (slMFB DBS) in major depression. Neuroimage Clin. 2018;20:580\u2013593."},{"key":"b26","series-title":"Parkinsons Dis","first-page":"3056018","article-title":"Experience reduces surgical and hardware-related complications of deep brain stimulation surgery: a single-center study of 181 patients operated in six years","volume":"2018","author":"Sorar M","year":"2018","unstructured":"Sorar M, Hanalioglu S, Kocer B, Eser MT, Comoglu SS, Kertmen H. Experience reduces surgical and hardware-related complications of deep brain stimulation surgery: a single-center study of 181 patients operated in six years. Parkinsons Dis. 2018;2018:3056018."},{"key":"b27","series-title":"Seizure","first-page":"154","article-title":"Long-term follow-up of anterior thalamic deep brain stimulation in epilepsy: a 11-year, single center experience","volume":"52","author":"Kim SH","year":"2017","unstructured":"Kim SH, Lim SC, Kim J, Son BC, Lee KJ, Shon YM. Long-term follow-up of anterior thalamic deep brain stimulation in epilepsy: a 11-year, single center experience. Seizure. 2017;52:154\u2013161."},{"key":"b28","series-title":"World Neurosurg","first-page":"537","article-title":"Analysis of delayed intracerebral hemorrhage associated with deep brain stimulation surgery","volume":"104","author":"Park CK","year":"2017","unstructured":"Park CK, Jung NY, Kim M, Chang JW. Analysis of delayed intracerebral hemorrhage associated with deep brain stimulation surgery. World Neurosurg. 2017;104:537\u2013544."},{"issue":"5","key":"b29","series-title":"Neuromodulation","first-page":"424","article-title":"The insertion of electrodes in the brain for electrophysiological recording or chronic stimulation is not associated with any biochemically detectable neuronal injury","volume":"20","author":"Themistocleous MS","year":"2017","unstructured":"Themistocleous MS, Sakas DE, Boviatsis E,  The insertion of electrodes in the brain for electrophysiological recording or chronic stimulation is not associated with any biochemically detectable neuronal injury. Neuromodulation. 2017;20(5):424\u2013428."},{"key":"b30","series-title":"Parkinsonism Relat Disord","first-page":"18","article-title":"Thalamic DBS with a constant-current device in essential tremor: a controlled clinical trial","volume":"40","author":"Wharen RE Jr","year":"2017","unstructured":"Wharen RE Jr, Okun MS, Guthrie BL,  Thalamic DBS with a constant-current device in essential tremor: a controlled clinical trial. Parkinsonism Relat Disord. 2017;40:18\u201326."},{"issue":"2","key":"b31","series-title":"Cerebellum","first-page":"421","article-title":"Does the use of intraoperative microelectrode recording influence the final location of lead implants in the ventral intermediate nucleus for deep brain stimulation?","volume":"16","author":"Reddy S","year":"2017","unstructured":"Reddy S, Fenoy A, Furr-Stimming E, Schiess M, Mehanna R. Does the use of intraoperative microelectrode recording influence the final location of lead implants in the ventral intermediate nucleus for deep brain stimulation? Cerebellum. 2017;16(2):421\u2013426."},{"key":"b32","series-title":"World Neurosurg","first-page":"734","article-title":"Comparison of the stereotactic accuracies of function-guided deep brain stimulation, calculated using multitrack target locations geometrically inferred from three-dimensional trajectory rotations, and of magnetic resonance imaging-guided deep brain stimulation and outcomes","volume":"98","author":"Park SC","year":"2017","unstructured":"Park SC, Lee CS, Kim SM, Choi EJ, Lee JK. Comparison of the stereotactic accuracies of function-guided deep brain stimulation, calculated using multitrack target locations geometrically inferred from three-dimensional trajectory rotations, and of magnetic resonance imaging-guided deep brain stimulation and outcomes. World Neurosurg. 2017;98:734\u2013749.e7."},{"issue":"5","key":"b33","series-title":"Stereotact Funct Neurosurg","first-page":"307","article-title":"Hemorrhage detection and incidence during magnetic resonance-guided deep brain stimulator implantations","volume":"95","author":"Martin AJ","year":"2017","unstructured":"Martin AJ, Starr PA, Ostrem JL, Larson PS. Hemorrhage detection and incidence during magnetic resonance-guided deep brain stimulator implantations. Stereotact Funct Neurosurg. 2017;95(5):307\u2013314."},{"issue":"2","key":"b34","series-title":"Br J Neurosurg","first-page":"217","article-title":"Clinical analysis and treatment of symptomatic intracranial hemorrhage after deep brain stimulation surgery","volume":"31","author":"Wang X","year":"2017","unstructured":"Wang X, Wang J, Zhao H,  Clinical analysis and treatment of symptomatic intracranial hemorrhage after deep brain stimulation surgery. Br J Neurosurg. 2017;31(2):217\u2013222."},{"issue":"1","key":"b35","series-title":"J Neurosurg","first-page":"62","article-title":"Intraoperative MRI for optimizing electrode placement for deep brain stimulation of the subthalamic nucleus in Parkinson disease","volume":"124","author":"Cui Z","year":"2016","unstructured":"Cui Z, Pan L, Song H,  Intraoperative MRI for optimizing electrode placement for deep brain stimulation of the subthalamic nucleus in Parkinson disease. J Neurosurg. 2016;124(1):62\u201369."},{"issue":"1","key":"b36","series-title":"PLoS One","first-page":"e0146644","article-title":"Long-term clinical outcome of internal globus pallidus deep brain stimulation for dystonia","volume":"11","author":"Park HR","year":"2016","unstructured":"Park HR, Lee JM, Ehm G,  Long-term clinical outcome of internal globus pallidus deep brain stimulation for dystonia. PLoS One. 2016;11(1):e0146644."},{"issue":"8","key":"b37","series-title":"Neuromodulation","first-page":"670","article-title":"Long-term evaluation of changes in operative technique and hardware-related complications with deep brain stimulation","volume":"18","author":"Falowski SM","year":"2015","unstructured":"Falowski SM, Ooi YC, Bakay RA. Long-term evaluation of changes in operative technique and hardware-related complications with deep brain stimulation. Neuromodulation. 2015;18(8):670\u2013677."},{"key":"b38","series-title":"Clin Neurol Neurosurg","first-page":"183","article-title":"A detailed analysis of intracerebral hemorrhages in DBS surgeries","volume":"139","author":"Tonge M","year":"2015","unstructured":"Tonge M, Ackermans L, Kocabicak E,  A detailed analysis of intracerebral hemorrhages in DBS surgeries. Clin Neurol Neurosurg. 2015;139:183\u2013187."},{"issue":"Suppl 2","key":"b39","series-title":"Neurosurgery","first-page":"190","article-title":"Adverse events associated with deep brain stimulation for movement disorders: analysis of 510 consecutive cases","volume":"11","author":"Patel DM","year":"2015","unstructured":"Patel DM, Walker HC, Brooks R, Omar N, Ditty B, Guthrie BL. Adverse events associated with deep brain stimulation for movement disorders: analysis of 510 consecutive cases. Neurosurgery. 2015;11(Suppl 2):190\u2013199."},{"issue":"8","key":"b40","series-title":"Acta Neurochir (Wien)","first-page":"1505","article-title":"Surgical adverse events of deep brain stimulation in the subthalamic nucleus of patients with Parkinson\u2019s disease. The learning curve and the pitfalls","volume":"156","author":"Seijo F","year":"2014","unstructured":"Seijo F, Alvarez de Eulate Beramendi S, Santamarta Li\u00e9bana E,  Surgical adverse events of deep brain stimulation in the subthalamic nucleus of patients with Parkinson\u2019s disease. The learning curve and the pitfalls. Acta Neurochir (Wien). 2014;156(8):1505\u20131512."},{"issue":"1","key":"b41","series-title":"J Neurosurg","first-page":"132","article-title":"Risks of common complications in deep brain stimulation surgery: management and avoidance","volume":"120","author":"Fenoy AJ","year":"2014","unstructured":"Fenoy AJ, Simpson RK Jr. Risks of common complications in deep brain stimulation surgery: management and avoidance. J Neurosurg. 2014;120(1):132\u2013139."},{"issue":"2","key":"b42","series-title":"Lancet Neurol","first-page":"140","article-title":"Subthalamic deep brain stimulation with a constant-current device in Parkinson\u2019s disease: an open-label randomised controlled trial","volume":"11","author":"Okun MS","year":"2012","unstructured":"Okun MS, Gallo BV, Mandybur G,  Subthalamic deep brain stimulation with a constant-current device in Parkinson\u2019s disease: an open-label randomised controlled trial. Lancet Neurol. 2012;11(2):140\u2013149."},{"issue":"1","key":"b43","series-title":"J Neurosurg","first-page":"107","article-title":"Deep brain stimulation of the subthalamic nucleus for advanced Parkinson disease using general anesthesia: long-term results","volume":"116","author":"Harries AM","year":"2012","unstructured":"Harries AM, Kausar J, Roberts SA,  Deep brain stimulation of the subthalamic nucleus for advanced Parkinson disease using general anesthesia: long-term results. J Neurosurg. 2012;116(1):107\u2013113."},{"issue":"11","key":"b44","series-title":"Neurol Med Chir (Tokyo)","first-page":"749","article-title":"Complications of subthalamic nucleus stimulation in Parkinson\u2019s disease","volume":"51","author":"Umemura A","year":"2011","unstructured":"Umemura A, Oka Y, Yamamoto K, Okita K, Matsukawa N, Yamada K. Complications of subthalamic nucleus stimulation in Parkinson\u2019s disease. Neurol Med Chir (Tokyo). 2011;51(11):749\u2013755."},{"issue":"4","key":"b45","series-title":"J Neurosurg","first-page":"852","article-title":"Intraoperative magnetic resonance imaging findings during deep brain stimulation surgery","volume":"115","author":"Huston OO","year":"2011","unstructured":"Huston OO, Watson RE, Bernstein MA,  Intraoperative magnetic resonance imaging findings during deep brain stimulation surgery. J Neurosurg. 2011;115(4):852\u2013857."},{"issue":"3","key":"b46","series-title":"Neurosurg Q","first-page":"194","article-title":"Hemorrhagic and repositioning risk factors related to intraoperative multitrack microrecording on a large series of patients treated for deep brain stimulation","volume":"21","author":"Servello D","year":"2011","unstructured":"Servello D, Sassi M, Pacchetti C,  Hemorrhagic and repositioning risk factors related to intraoperative multitrack microrecording on a large series of patients treated for deep brain stimulation. Neurosurg Q. 2011;21(3):194\u2013198."},{"issue":"8","key":"b47","series-title":"Acta Neurochir (Wien)","first-page":"1573","article-title":"Analysis of hemorrhagic risk factors during deep brain stimulation surgery for movement disorders: comparison of the circumferential paired and multiple electrode insertion methods","volume":"153","author":"Park JH","year":"2011","unstructured":"Park JH, Chung SJ, Lee CS, Jeon SR. Analysis of hemorrhagic risk factors during deep brain stimulation surgery for movement disorders: comparison of the circumferential paired and multiple electrode insertion methods. Acta Neurochir (Wien). 2011;153(8):1573\u20131578."},{"issue":"12","key":"b48","series-title":"Acta Neurochir (Wien)","first-page":"2053","article-title":"Surgical and hardware complications of deep brain stimulation. A seven-year experience and review of the literature","volume":"152","author":"Boviatsis EJ","year":"2010","unstructured":"Boviatsis EJ, Stavrinou LC, Themistocleous M, Kouyialis AT, Sakas DE. Surgical and hardware complications of deep brain stimulation. A seven-year experience and review of the literature. Acta Neurochir (Wien). 2010;152(12):2053\u20132062."},{"issue":"4","key":"b49","series-title":"World Neurosurg","first-page":"338","article-title":"Surgical, medical, and hardware adverse events in a series of 141 patients undergoing subthalamic deep brain stimulation for Parkinson disease","volume":"73","author":"Vergani F","year":"2010","unstructured":"Vergani F, Landi A, Pirillo D, Cilia R, Antonini A, Sganzerla EP. Surgical, medical, and hardware adverse events in a series of 141 patients undergoing subthalamic deep brain stimulation for Parkinson disease. World Neurosurg. 2010;73(4):338\u2013344."},{"issue":"5","key":"b50","series-title":"Stereotact Funct Neurosurg","first-page":"296","article-title":"Avoidance and management of surgical and hardware-related complications of deep brain stimulation","volume":"88","author":"Hu X","year":"2010","unstructured":"Hu X, Jiang X, Zhou X,  Avoidance and management of surgical and hardware-related complications of deep brain stimulation. Stereotact Funct Neurosurg. 2010;88(5):296\u2013303."},{"issue":"6 Suppl","key":"b51","series-title":"Neurosurgery","first-page":"196","article-title":"Magnetic resonance-based deep brain stimulation technique: a series of 478 consecutive implanted electrodes with no perioperative intracerebral hemorrhage","volume":"65","author":"Maldonado IL","year":"2009","unstructured":"Maldonado IL, Roujeau T, Cif L,  Magnetic resonance-based deep brain stimulation technique: a series of 478 consecutive implanted electrodes with no perioperative intracerebral hemorrhage. Neurosurgery. 2009;65(6 Suppl):196\u2013202."},{"issue":"2","key":"b52","series-title":"Neurosurgery","first-page":"276","article-title":"Subcutaneous heparin for prophylaxis of venous thromboembolism in deep brain stimulation surgery: evidence from a decision analysis","volume":"65","author":"Bauman JA","year":"2009","unstructured":"Bauman JA, Church E, Halpern CH,  Subcutaneous heparin for prophylaxis of venous thromboembolism in deep brain stimulation surgery: evidence from a decision analysis. Neurosurgery. 2009;65(2):276\u2013280."},{"issue":"20","key":"b53","series-title":"N Engl J Med","first-page":"2121","article-title":"Subthalamic nucleus stimulation in severe obsessive-compulsive disorder","volume":"359","author":"Mallet L","year":"2008","unstructured":"Mallet L, Polosan M, Jaafari N,  Subthalamic nucleus stimulation in severe obsessive-compulsive disorder. N Engl J Med. 2008;359(20):2121\u20132134."},{"issue":"6","key":"b54","series-title":"Stereotact Funct Neurosurg","first-page":"367","article-title":"Surgical complications of deep brain stimulation. A longitudinal single surgeon, single institution study","volume":"86","author":"Bhatia S","year":"2008","unstructured":"Bhatia S, Oh M, Whiting T, Quigley M, Whiting D. Surgical complications of deep brain stimulation. A longitudinal single surgeon, single institution study. Stereotact Funct Neurosurg. 2008;86(6):367\u2013372."},{"issue":"10","key":"b55","series-title":"Mov Disord","first-page":"1457","article-title":"Does ageing influence deep brain stimulation outcomes in Parkinson\u2019s disease?","volume":"22","author":"Ory-Magne F","year":"2007","unstructured":"Ory-Magne F, Brefel-Courbon C, Simonetta-Moreau M,  Does ageing influence deep brain stimulation outcomes in Parkinson\u2019s disease? Mov Disord. 2007;22(10):1457\u20131463."},{"issue":"10","key":"b56","series-title":"Mov Disord","first-page":"1486","article-title":"Thirty days complication rate following surgery performed for deep-brain-stimulation","volume":"22","author":"Voges J","year":"2007","unstructured":"Voges J, Hilker R, B\u00f6tzel K,  Thirty days complication rate following surgery performed for deep-brain-stimulation. Mov Disord. 2007;22(10):1486\u20131489."},{"issue":"4","key":"b57","series-title":"J Neurosurg","first-page":"621","article-title":"Short-term and long-term safety of deep brain stimulation in the treatment of movement disorders","volume":"106","author":"Kenney C","year":"2007","unstructured":"Kenney C, Simpson R, Hunter C,  Short-term and long-term safety of deep brain stimulation in the treatment of movement disorders. J Neurosurg. 2007;106(4):621\u2013625."},{"key":"b58","series-title":"BMC Neurol","first-page":"7","article-title":"Subthalamic nucleus deep brain stimulation in elderly patients\u2014analysis of outcome and complications","volume":"7","author":"Vesper J","year":"2007","unstructured":"Vesper J, Haak S, Ostertag C, Nikkhah G. Subthalamic nucleus deep brain stimulation in elderly patients\u2014analysis of outcome and complications. BMC Neurol. 2007;7:7."},{"issue":"7","key":"b59","series-title":"J Neurol Neurosurg Psychiatry","first-page":"868","article-title":"Deep-brain stimulation: long-term analysis of complications caused by hardware and surgery\u2014experiences from a single centre","volume":"77","author":"Voges J","year":"2006","unstructured":"Voges J, Waerzeggers Y, Maarouf M,  Deep-brain stimulation: long-term analysis of complications caused by hardware and surgery\u2014experiences from a single centre. J Neurol Neurosurg Psychiatry. 2006;77(7):868\u2013872."},{"issue":"4","key":"b60","series-title":"Neurology","first-page":"612","article-title":"Surgical and hardware complications of subthalamic stimulation: a series of 160 procedures","volume":"63","author":"Lyons KE","year":"2004","unstructured":"Lyons KE, Wilkinson SB, Overman J, Pahwa R. Surgical and hardware complications of subthalamic stimulation: a series of 160 procedures. Neurology. 2004;63(4):612\u2013616."},{"issue":"11","key":"b61","series-title":"Mov Disord","first-page":"1332","article-title":"Two-year follow-up of subthalamic deep brain stimulation in Parkinson\u2019s disease","volume":"18","author":"Herzog J","year":"2003","unstructured":"Herzog J, Volkmann J, Krack P,  Two-year follow-up of subthalamic deep brain stimulation in Parkinson\u2019s disease. Mov Disord. 2003;18(11):1332\u20131337."},{"issue":"6","key":"b62","series-title":"Neurosurgery","first-page":"1268","article-title":"Long-term hardware-related complications of deep brain stimulation","volume":"50","author":"Oh MY","year":"2002","unstructured":"Oh MY, Abosch A, Kim SH, Lang AE, Lozano AM. Long-term hardware-related complications of deep brain stimulation. Neurosurgery. 2002;50(6):1268\u20131276."},{"issue":"1-4","key":"b63","series-title":"Stereotact Funct Neurosurg","first-page":"73","article-title":"Complications of deep brain stimulation surgery","volume":"77","author":"Beric A","year":"2002","unstructured":"Beric A, Kelly PJ, Rezai A,  Complications of deep brain stimulation surgery. Stereotact Funct Neurosurg. 2002;77(1-4):73\u201378."},{"issue":"13","key":"b64","series-title":"N Engl J Med","first-page":"956","article-title":"Deep-brain stimulation of the subthalamic nucleus or the pars interna of the globus pallidus in Parkinson\u2019s disease","volume":"345","author":"Obeso JA","year":"2001","unstructured":"Obeso JA, Olanow CW, Rodriguez-Oroz MC, Krack P, Kumar R, Lang AE. Deep-brain stimulation of the subthalamic nucleus or the pars interna of the globus pallidus in Parkinson\u2019s disease. N Engl J Med. 2001;345(13):956\u2013963."},{"issue":"3","key":"b65","series-title":"Mov Disord","first-page":"464","article-title":"Long-term safety and efficacy of unilateral deep brain stimulation of the thalamus in essential tremor","volume":"16","author":"Koller WC","year":"2001","unstructured":"Koller WC, Lyons KE, Wilkinson SB, Troster AI, Pahwa R. Long-term safety and efficacy of unilateral deep brain stimulation of the thalamus in essential tremor. Mov Disord. 2001;16(3):464\u2013468."},{"issue":"6","key":"b66","series-title":"Neurosurgery","first-page":"885","article-title":"Treatment of chronic pain by deep brain stimulation: long term follow-up and review of the literature","volume":"21","author":"Levy RM","year":"1987","unstructured":"Levy RM, Lamb S, Adams JE. Treatment of chronic pain by deep brain stimulation: long term follow-up and review of the literature. Neurosurgery. 1987;21(6):885\u2013893."},{"issue":"1","key":"b67","series-title":"J Neurosurg","first-page":"43","article-title":"Pallidotomy for Parkinson disease: a review of contemporary literature","volume":"94","author":"Alkhani A","year":"2001","unstructured":"Alkhani A, Lozano AM. Pallidotomy for Parkinson disease: a review of contemporary literature. J Neurosurg. 2001;94(1):43\u201349."},{"issue":"6","key":"b68","series-title":"J Neurosurg","first-page":"1058","article-title":"A metaanalysis comparing the results of pallidotomy performed using microelectrode recording or macroelectrode stimulation","volume":"96","author":"Palur RS","year":"2002","unstructured":"Palur RS, Berk C, Schulzer M, Honey CR. A metaanalysis comparing the results of pallidotomy performed using microelectrode recording or macroelectrode stimulation. J Neurosurg. 2002;96(6):1058\u20131062."},{"issue":"2","key":"b69","series-title":"Neurosurgery","first-page":"169","article-title":"Technique, results, and complications related to robot-assisted stereoelectroencephalography","volume":"78","author":"Gonz\u00e1lez-Mart\u00ednez J","year":"2016","unstructured":"Gonz\u00e1lez-Mart\u00ednez J, Bulacio J, Thompson S,  Technique, results, and complications related to robot-assisted stereoelectroencephalography. Neurosurgery. 2016;78(2):169\u2013180."},{"issue":"9","key":"b70","series-title":"Epilepsia","first-page":"1942","article-title":"Stereoelectroencephalography electrode placement: detection of blood vessel conflicts","volume":"60","author":"Li K","year":"2019","unstructured":"Li K, Vakharia VN, Sparks R,  Stereoelectroencephalography electrode placement: detection of blood vessel conflicts. Epilepsia. 2019;60(9):1942\u20131948."},{"issue":"2","key":"b71","series-title":"J Neurosurg","first-page":"263","article-title":"A stereotactic near-infrared probe for localization during functional neurosurgical procedures: further experience","volume":"110","author":"Giller CA","year":"2009","unstructured":"Giller CA, Liu H, German DC, Kashyap D, Dewey RB. A stereotactic near-infrared probe for localization during functional neurosurgical procedures: further experience. J Neurosurg. 2009;110(2):263\u2013273."},{"issue":"6","key":"b72","series-title":"Neuromodulation","first-page":"836","article-title":"Lesser-known aspects of deep brain stimulation for Parkinson\u2019s disease: programming sessions, hardware surgeries, residential care admissions, and deaths","volume":"25","author":"Xu SS","year":"2022","unstructured":"Xu SS, Malpas CB, Bulluss KJ, McDermott HJ, Kalincik T, Thevathasan W. Lesser-known aspects of deep brain stimulation for Parkinson\u2019s disease: programming sessions, hardware surgeries, residential care admissions, and deaths. Neuromodulation. 2022;25(6):836\u2013845."},{"issue":"4","key":"b73","series-title":"J Neurosurg","first-page":"779","article-title":"Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients","volume":"98","author":"Umemura A","year":"2003","unstructured":"Umemura A, Jaggi JL, Hurtig HI,  Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients. J Neurosurg. 2003;98(4):779\u2013784."},{"issue":"1","key":"b74","series-title":"Syst Rev","first-page":"204","article-title":"Relationship between surgeon volume and outcomes: a systematic review of systematic reviews","volume":"5","author":"Morche J","year":"2016","unstructured":"Morche J, Mathes T, Pieper D. Relationship between surgeon volume and outcomes: a systematic review of systematic reviews. Syst Rev. 2016;5(1):204."},{"key":"b75","series-title":"Front Hum Neurosci","first-page":"644593","article-title":"Proceedings of the Eighth Annual Deep Brain Stimulation Think Tank: advances in optogenetics, ethical issues affecting DBS research, neuromodulatory approaches for depression, adaptive neurostimulation, and emerging DBS technologies","volume":"15","author":"Vedam-Mai V","year":"2021","unstructured":"Vedam-Mai V, Deisseroth K, Giordano J,  Proceedings of the Eighth Annual Deep Brain Stimulation Think Tank: advances in optogenetics, ethical issues affecting DBS research, neuromodulatory approaches for depression, adaptive neurostimulation, and emerging DBS technologies. Front Hum Neurosci. 2021;15:644593."}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/141\/2\/article-p381.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/141\/2\/article-p381.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/141\/2\/article-p381.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,26]],"date-time":"2024-11-26T11:44:27Z","timestamp":1732621467000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/141\/2\/article-p381.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,1]]},"references-count":75,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3171\/2024.1.jns232385","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,1]]}}}