{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:01:49Z","timestamp":1787065309056,"version":"build-2736575974"},"reference-count":92,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,7,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>The Flow-Redirection Endoluminal Device X (FRED X) is a newer generation flow diverter with surface modifications aimed at minimizing thrombogenicity. At present, data on its long-term efficacy are limited. This multicenter study presents the largest series within the United States describing the device\u2019s efficacy, safety, and long-term outcomes in treating cerebral aneurysms of varying morphology.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>Patients treated with the FRED X for a cerebral aneurysm between February 2022 and February 2024 at 6 high-volume centers across the United States were included. Data were collected regarding demographics, clinical presentation, and procedural efficacy. Angiographic and clinical follow-up outcomes were assessed at 6 and 12 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>A total of 154 patients with 162 aneurysms were treated with 164 FRED X devices over the study period. Overall, 81.8% of the cohort was female with a mean age of 56.8 years. The authors observed satisfactory rates (\u2265 99.3%) of device deployment and good wall apposition and neck coverage. One hundred forty-seven (95.5%) patients were functionally independent at discharge (modified Rankin Scale scores 0\u20132). Rates of adequate occlusion (Raymond-Roy Occlusion Scale score I or II) increased from 84.2% at 6 months to 83.5% at the 12-month follow-up, while rates of in-stent stenosis decreased. All patients (100%) who underwent follow-up were functionally independent at 6 months, and 95.9% were functionally independent at 12 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>This multicenter cohort study demonstrates the ease of FRED X deployment with an adequate safety profile, with low rates of procedural complications and favorable outcomes on follow-up. Rates of aneurysm occlusion increased over time, with a subsequent decrease in stent-associated complications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2024.10.jns241233","type":"journal-article","created":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T20:45:20Z","timestamp":1740775520000},"page":"232-242","source":"Crossref","is-referenced-by-count":9,"title":["Long-term safety and efficacy of the FRED X flow diverter for intracranial aneurysms: a multicenter study of 154 patients"],"prefix":"10.3171","volume":"143","author":[{"given":"Joanna M.","family":"Roy","sequence":"first","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kareem","family":"El Naamani","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheritesh","family":"Amaravadi","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shyam","family":"Majmundar","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikolaos","family":"Mouchtouris","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandra R.","family":"Paul","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Albany Medical Center, Albany, New York;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas C.","family":"Field","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Albany Medical Center, Albany, New York;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Queens University Medical Group, Honolulu, Hawaii;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan-Karl","family":"Burkhardt","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hospital of the University of Pennsylvania, Penn Medicine, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Luisa","family":"K\u00fchn","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Massachusetts, Boston, Massachusetts; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajit","family":"Puri","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Massachusetts, Boston, Massachusetts; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elad","family":"Levy","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University at Buffalo, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. Reid","family":"Gooch","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pascal","family":"Jabbour","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert H.","family":"Rosenwasser","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stavropoula I.","family":"Tjoumakaris","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"6","key":"b1","series-title":"Neurosurg Focus","first-page":"E2","article-title":"Update on flow diverters for the endovascular management of cerebral aneurysms","volume":"42","author":"Rajah G","year":"2017","unstructured":"Rajah G, Narayanan S, Rangel-Castilla L. Update on flow diverters for the endovascular management of cerebral aneurysms. Neurosurg Focus. 2017;42(6):E2."},{"issue":"Suppl 1","key":"b2","series-title":"Neurosurgery","first-page":"S36","article-title":"Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes","volume":"86","author":"Chancellor B","year":"2020","unstructured":"Chancellor B, Raz E, Shapiro M,  Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes. Neurosurgery. 2020;86(Suppl 1):S36-S45."},{"issue":"2","key":"b3","series-title":"Stroke","first-page":"442","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji W","year":"2013","unstructured":"Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke. 2013;44(2):442\u2013447."},{"issue":"4","key":"b4","series-title":"Neuroradiology","first-page":"391","article-title":"Flow diverter treatment of posterior circulation aneurysms. A meta-analysis","volume":"58","author":"Wang CB","year":"2016","unstructured":"Wang CB, Shi WW, Zhang GX, Lu HC, Ma J. Flow diverter treatment of posterior circulation aneurysms. A meta-analysis. Neuroradiology. 2016;58(4):391\u2013400."},{"issue":"9","key":"b5","series-title":"J Neurointerv Surg","first-page":"898","article-title":"Long-term outcomes of flow diversion for unruptured intracranial aneurysms: a systematic review and meta-analysis","volume":"15","author":"Shehata MA","year":"2023","unstructured":"Shehata MA, Ibrahim MK, Ghozy S,  Long-term outcomes of flow diversion for unruptured intracranial aneurysms: a systematic review and meta-analysis. J Neurointerv Surg. 2023;15(9):898\u2013902."},{"issue":"6","key":"b6","series-title":"Neurosurg Focus","first-page":"E3","article-title":"Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center","volume":"42","author":"Briganti F","year":"2017","unstructured":"Briganti F, Leone G, Cirillo L, de Divitiis O, Solari D, Cappabianca P. Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center. Neurosurg Focus. 2017;42(6):E3."},{"issue":"2","key":"b7","series-title":"Neurosurg Clin N Am","first-page":"215","article-title":"Novel innovation in flow diversion: surface modifications","volume":"33","author":"Hudson JS","year":"2022","unstructured":"Hudson JS, Lang MJ, Gross BA. Novel innovation in flow diversion: surface modifications. Neurosurg Clin N Am. 2022;33(2):215\u2013218."},{"key":"b8","series-title":"Interv Neuroradiol. Published online October","article-title":"Flow diverter surface modifications for aneurysm treatment: a review of the mechanisms and data behind existing technologies","volume":"29,","author":"White TG","year":"2023","unstructured":"White TG, Santhumayor BA, Turpin J,  Flow diverter surface modifications for aneurysm treatment: a review of the mechanisms and data behind existing technologies. Interv Neuroradiol. Published online October 29,2023. doi:10.1177\/15910199231207550"},{"issue":"3","key":"b9","series-title":"Interv Neuroradiol","first-page":"350","article-title":"Treatment of ruptured intracranial aneurysms using the novel generation of flow-diverters with surface modification: a systematic review and meta-analysis","volume":"30","author":"Monteiro A","year":"2024","unstructured":"Monteiro A, Khan A, Donnelly BM,  Treatment of ruptured intracranial aneurysms using the novel generation of flow-diverters with surface modification: a systematic review and meta-analysis. Interv Neuroradiol. 2024;30(3):350\u2013360."},{"key":"b10","series-title":"World Neurosurg","first-page":"e184","article-title":"First U.S. experience using the Pipeline Flex Embolization Device with Shield technology for treatment of intracranial aneurysms","volume":"159","author":"Cappuzzo JM","year":"2022","unstructured":"Cappuzzo JM, Monteiro A, Taylor MN,  First U.S. experience using the Pipeline Flex Embolization Device with Shield technology for treatment of intracranial aneurysms. World Neurosurg. 2022;159:e184\u2013e191."},{"issue":"6","key":"b11","series-title":"Neuroradiology","first-page":"1213","article-title":"Efficacy of the Flow Re-direction Endoluminal Device for cerebral aneurysms and causes of failed deployment","volume":"64","author":"Suyama K","year":"2022","unstructured":"Suyama K, Nakahara I, Matsumoto S,  Efficacy of the Flow Re-direction Endoluminal Device for cerebral aneurysms and causes of failed deployment. Neuroradiology. 2022;64(6):1213\u20131219."},{"issue":"3","key":"b12","series-title":"Interv Neuroradiol","first-page":"347","article-title":"Flow redirection endoluminal device (FRED) for treatment of intracranial aneurysms: a systematic review","volume":"28","author":"Waqas M","year":"2022","unstructured":"Waqas M, Dossani RH, Alkhaldi M,  Flow redirection endoluminal device (FRED) for treatment of intracranial aneurysms: a systematic review. Interv Neuroradiol. 2022;28(3):347\u2013357."},{"issue":"6","key":"b13","series-title":"AJNR Am J Neuroradiol","first-page":"1155","article-title":"The FRED flow-diverter stent for intracranial aneurysms: clinical study to assess safety and efficacy","volume":"36","author":"M\u00f6hlenbruch MA","year":"2015","unstructured":"M\u00f6hlenbruch MA, Herweh C, Jestaedt L,  The FRED flow-diverter stent for intracranial aneurysms: clinical study to assess safety and efficacy. AJNR Am J Neuroradiol. 2015;36(6):1155\u20131161."},{"issue":"2","key":"b14","series-title":"J Neurointerv Surg","first-page":"153","article-title":"Comparison of PED and FRED flow diverters for posterior circulation aneurysms: a propensity score matched cohort study","volume":"13","author":"Griessenauer CJ","year":"2021","unstructured":"Griessenauer CJ, Enriquez-Marulanda A, Xiang S,  Comparison of PED and FRED flow diverters for posterior circulation aneurysms: a propensity score matched cohort study. J Neurointerv Surg. 2021;13(2):153\u2013158."},{"issue":"2","key":"b15","series-title":"Neurosurgery","first-page":"E249","article-title":"Comparison of Pipeline Embolization Device and Flow Re-Direction Endoluminal Device flow diverters for internal carotid artery aneurysms: a propensity score-matched cohort study","volume":"85","author":"Griessenauer CJ","year":"2019","unstructured":"Griessenauer CJ, Thomas AJ, Enriquez-Marulanda A,  Comparison of Pipeline Embolization Device and Flow Re-Direction Endoluminal Device flow diverters for internal carotid artery aneurysms: a propensity score-matched cohort study. Neurosurgery. 2019;85(2):E249\u2013E255."},{"key":"b16","series-title":"Interv Neuroradiol","article-title":"Comparison of pipeline embolization device, flow re-direction endoluminal device and surpass flow diverters in the treatment of intracerebral aneurysms","author":"Field NC","unstructured":"Field NC, Custozzo A, Gajjar AA, Dalfino JC, Boulos AS, Paul AR. Comparison of pipeline embolization device, flow re-direction endoluminal device and surpass flow diverters in the treatment of intracerebral aneurysms. Interv Neuroradiol. Published online August 27, 2023. doi:10.1177\/15910199231196621"},{"issue":"e1","key":"b17","series-title":"J Neurointerv Surg","first-page":"e159","article-title":"Flow diverter stents for endovascular treatment of aneurysms: a comparative study of efficacy and safety between FREDX and FRED","volume":"17","author":"Guimaraens L","year":"2024","unstructured":"Guimaraens L, Salda\u00f1a J, Vivas E,  Flow diverter stents for endovascular treatment of aneurysms: a comparative study of efficacy and safety between FREDX and FRED. J Neurointerv Surg. 2024;17(e1):e159\u2013e165."},{"issue":"3","key":"b18","series-title":"Radiology","first-page":"858","article-title":"Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial","volume":"267","author":"Becske T","year":"2013","unstructured":"Becske T, Kallmes DF, Saatci I,  Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology. 2013;267(3):858\u2013868."},{"issue":"1","key":"b19","series-title":"AJNR Am J Neuroradiol","first-page":"34","article-title":"The pipeline embolization device for the intracranial treatment of aneurysms trial","volume":"32","author":"Nelson PK","year":"2011","unstructured":"Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D. The pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol. 2011;32(1):34\u201340."},{"issue":"1","key":"b20","series-title":"Neurosurgery","first-page":"118","article-title":"Comparison of Flow-Redirection Endoluminal Device and Pipeline Embolization Device in the treatment of intracerebral aneurysms","volume":"92","author":"El Naamani K","year":"2023","unstructured":"El Naamani K, Saad H, Chen CJ,  Comparison of Flow-Redirection Endoluminal Device and Pipeline Embolization Device in the treatment of intracerebral aneurysms. Neurosurgery. 2023;92(1):118\u2013124."},{"issue":"3","key":"b21","series-title":"Interv Neuroradiol","first-page":"302","article-title":"Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms","volume":"28","author":"G\u00fcndo\u011fmu\u015f CA","year":"2022","unstructured":"G\u00fcndo\u011fmu\u015f CA, Sabet S, Baltac\u0131o\u011flu NA, T\u00fcreli D, Bayri Y, Baltac\u0131o\u011flu F. Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms. Interv Neuroradiol. 2022;28(3):302\u2013310."},{"issue":"4","key":"b22","series-title":"J Neurosurg","first-page":"1054","article-title":"First United States multicenter experience with the new-generation FRED X surface-modified flow diversion stent: feasibility, safety, and short-term efficacy","volume":"140","author":"Abbas R","year":"2023","unstructured":"Abbas R, Lan M, Naamani KE,  First United States multicenter experience with the new-generation FRED X surface-modified flow diversion stent: feasibility, safety, and short-term efficacy. J Neurosurg. 2023;140(4):1054\u20131063."},{"issue":"4","key":"b23","series-title":"AJNR Am J Neuroradiol","first-page":"474","article-title":"The FRESH Study: treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology\u2014first multicenter experience in 161 patients","volume":"44","author":"Vollherbst DF","year":"2023","unstructured":"Vollherbst DF, L\u00fccking H, DuPlessis J,  The FRESH Study: treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology\u2014first multicenter experience in 161 patients. AJNR Am J Neuroradiol. 2023;44(4):474\u2013480."},{"issue":"2","key":"b24","series-title":"J Neurointerv Surg","first-page":"184","article-title":"SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results","volume":"11","author":"Pierot L","year":"2019","unstructured":"Pierot L, Spelle L, Berge J,  SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results. J Neurointerv Surg. 2019;11(2):184\u2013189."},{"issue":"11","key":"b25","series-title":"J Neurointerv Surg","first-page":"1107","article-title":"Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study","volume":"12","author":"Rice H","year":"2020","unstructured":"Rice H, Mart\u00ednez Gald\u00e1mez M, Holtmannsp\u00f6tter M,  Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study. J Neurointerv Surg. 2020;12(11):1107\u20131112."},{"issue":"7","key":"b26","series-title":"J Neurointerv Surg","first-page":"694","article-title":"Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience","volume":"11","author":"Manning NW","year":"2019","unstructured":"Manning NW, Cheung A, Phillips TJ, Wenderoth JD. Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience. J Neurointerv Surg. 2019;11(7):694\u2013698."},{"issue":"8","key":"b27","series-title":"J Neurointerv Surg","first-page":"772","article-title":"Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study","volume":"9","author":"Mart\u00ednez-Gald\u00e1mez M","year":"2017","unstructured":"Mart\u00ednez-Gald\u00e1mez M, Lamin SM, Lagios KG,  Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study. J Neurointerv Surg. 2017;9(8):772\u2013776."},{"issue":"6","key":"b28","series-title":"Neuroradiology","first-page":"943","article-title":"Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study","volume":"63","author":"Dinc H","year":"2021","unstructured":"Dinc H, Saatci I, Oguz S,  Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study. Neuroradiology. 2021;63(6):943\u2013952."},{"issue":"5","key":"b29","series-title":"AJNR Am J Neuroradiol","first-page":"841","article-title":"European multicenter study for the evaluation of a dual-layer flow-diverting stent for treatment of wide-neck intracranial aneurysms: the European Flow-Redirection Intraluminal Device Study","volume":"39","author":"Killer-Oberpfalzer M","year":"2018","unstructured":"Killer-Oberpfalzer M, Kocer N, Griessenauer CJ,  European multicenter study for the evaluation of a dual-layer flow-diverting stent for treatment of wide-neck intracranial aneurysms: the European Flow-Redirection Intraluminal Device Study. AJNR Am J Neuroradiol. 2018;39(5):841\u2013847."},{"issue":"1","key":"b30","series-title":"J Neurosurg","first-page":"174","article-title":"FRED Italian Registry: a multicenter experience with the flow re-direction endoluminal device for intracranial aneurysms","volume":"133","author":"Piano M","year":"2019","unstructured":"Piano M, Valvassori L, Lozupone E,  FRED Italian Registry: a multicenter experience with the flow re-direction endoluminal device for intracranial aneurysms. J Neurosurg. 2019;133(1):174\u2013181."},{"issue":"6","key":"b31","series-title":"Neuroradiol J","first-page":"471","article-title":"Pipeline Flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes","volume":"33","author":"Yeomans J","year":"2020","unstructured":"Yeomans J, Sandu L, Sastry A. Pipeline Flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes. Neuroradiol J. 2020;33(6):471\u2013478."},{"issue":"4","key":"b32","series-title":"J Neurointerv Surg","first-page":"407","article-title":"Diffusion weighted image documented cerebral ischemia in the postprocedural period following pipeline embolization device with shield technology treatment of unruptured intracranial aneurysms: a prospective, single center study","volume":"12","author":"Pikis S","year":"2020","unstructured":"Pikis S, Mantziaris G, Mamalis V,  Diffusion weighted image documented cerebral ischemia in the postprocedural period following pipeline embolization device with shield technology treatment of unruptured intracranial aneurysms: a prospective, single center study. J Neurointerv Surg. 2020;12(4):407\u2013411."},{"issue":"12","key":"b33","series-title":"AJNR Am J Neuroradiol","first-page":"2094","article-title":"Outcome study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU)","volume":"40","author":"Atasoy D","year":"2019","unstructured":"Atasoy D, Kandasamy N, Hart J,  Outcome study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU). AJNR Am J Neuroradiol. 2019;40(12):2094\u20132101."},{"issue":"1","key":"b34","series-title":"Neurosurgery","first-page":"104","article-title":"Safety and effectiveness of the Pipeline Flex Embolization Device with Shield technology for the treatment of intracranial aneurysms: midterm results from a multicenter study","volume":"87","author":"Trivelato FP","year":"2020","unstructured":"Trivelato FP, Wajnberg E, Rezende MTS,  Safety and effectiveness of the Pipeline Flex Embolization Device with Shield technology for the treatment of intracranial aneurysms: midterm results from a multicenter study. Neurosurgery. 2020;87(1):104\u2013111."},{"issue":"5","key":"b35","series-title":"Neurosurg Focus","first-page":"E7","article-title":"Safety and efficacy of the p48 MW and p64 flow modulation devices: a systematic review and meta-analysis","volume":"54","author":"Vivanco-Suarez J","year":"2023","unstructured":"Vivanco-Suarez J, Salem MM, Sioutas GS,  Safety and efficacy of the p48 MW and p64 flow modulation devices: a systematic review and meta-analysis. Neurosurg Focus. 2023;54(5):E7."},{"issue":"1","key":"b36","series-title":"J Neurointerv Surg","first-page":"62","article-title":"Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results","volume":"12","author":"Hanel RA","year":"2020","unstructured":"Hanel RA, Kallmes DF, Lopes DK,  Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results. J Neurointerv Surg. 2020;12(1):62\u201366."},{"issue":"8","key":"b37","series-title":"J Neurointerv Surg","first-page":"765","article-title":"Feasibility, complications, morbidity, and mortality results at 6 months for aneurysm treatment with the Flow Re-Direction Endoluminal Device: report of SAFE study","volume":"10","author":"Pierot L","year":"2018","unstructured":"Pierot L, Spelle L, Berge J,  Feasibility, complications, morbidity, and mortality results at 6 months for aneurysm treatment with the Flow Re-Direction Endoluminal Device: report of SAFE study. J Neurointerv Surg. 2018;10(8):765\u2013770."},{"issue":"2","key":"b38","series-title":"Neurosurgery","first-page":"330","article-title":"Comparison of thromboembolic events between Pipeline Embolization Device (PED) Shield and PED\/PED Flex: a propensity score-matched analysis","volume":"95","author":"Ramirez-Velandia F","year":"2024","unstructured":"Ramirez-Velandia F, Enriquez-Marulanda A, Filo J,  Comparison of thromboembolic events between Pipeline Embolization Device (PED) Shield and PED\/PED Flex: a propensity score-matched analysis. Neurosurgery. 2024;95(2):330\u2013338."},{"issue":"2","key":"b39","series-title":"J Neurosurg","first-page":"436","article-title":"Comparison of PED\/PED Flex and PED Shield in the treatment of unruptured intracerebral aneurysms","volume":"140","author":"El Naamani K","year":"2023","unstructured":"El Naamani K, Mastorakos P, Yudkoff CJ,  Comparison of PED\/PED Flex and PED Shield in the treatment of unruptured intracerebral aneurysms. J Neurosurg. 2023;140(2):436\u2013440."},{"issue":"2","key":"b40","series-title":"J Neurointerv Surg","first-page":"166","article-title":"Transient in-stent stenosis at mid-term angiographic follow-up in patients treated with SILK flow diverter stents: incidence, clinical significance and long-term follow-up","volume":"11","author":"Essbaiheen F","year":"2019","unstructured":"Essbaiheen F, AlQahtani H, Almansoori TM,  Transient in-stent stenosis at mid-term angiographic follow-up in patients treated with SILK flow diverter stents: incidence, clinical significance and long-term follow-up. J Neurointerv Surg. 2019;11(2):166\u2013170."},{"issue":"9378","key":"b41","series-title":"Lancet","first-page":"103","article-title":"Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment","volume":"362","author":"Wiebers DO","year":"2003","unstructured":"Wiebers DO, Whisnant JP, Huston J III,  Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet. 2003;362(9378):103\u2013110."},{"issue":"5","key":"b42","series-title":"J Neuroradiol","first-page":"336","article-title":"Unruptured intracranial aneurysms","volume":"30","author":"White PM","year":"2003","unstructured":"White PM, Wardlaw JM. Unruptured intracranial aneurysms. J Neuroradiol. 2003;30(5):336\u2013350."},{"issue":"2","key":"b43","series-title":"J Neurosurg","first-page":"310","article-title":"The natural history of aneurysms incompletely occluded by placement of a flow diverter: a multiinstitutional study","volume":"141","author":"Theiss P","year":"2024","unstructured":"Theiss P, Ali AE, McGuire LS,  The natural history of aneurysms incompletely occluded by placement of a flow diverter: a multiinstitutional study. J Neurosurg. 2024;141(2):310\u2013315."},{"issue":"6","key":"b44","series-title":"Neurosurg Focus","first-page":"E4","article-title":"Off-label uses of the Pipeline embolization device: a review of the literature","volume":"42","author":"Patel PD","year":"2017","unstructured":"Patel PD, Chalouhi N, Atallah E,  Off-label uses of the Pipeline embolization device: a review of the literature. Neurosurg Focus. 2017;42(6):E4."},{"issue":"5","key":"b45","series-title":"Stroke","first-page":"1428","article-title":"ARISE I consensus review on the management of intracranial aneurysms","volume":"55","author":"Tjoumakaris SI","year":"2024","unstructured":"Tjoumakaris SI, Hanel R, Mocco J,  ARISE I consensus review on the management of intracranial aneurysms. Stroke. 2024;55(5):1428\u20131437."},{"issue":"2","key":"b46","series-title":"Interv Neuroradiol","first-page":"133","article-title":"A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents","volume":"16","author":"O\u2019Kelly CJ","year":"2010","unstructured":"O\u2019Kelly CJ, Krings T, Fiorella D, Marotta TR. A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol. 2010;16(2):133\u2013137."},{"issue":"6","key":"b1","series-title":"Neurosurg Focus","first-page":"E2","article-title":"Update on flow diverters for the endovascular management of cerebral aneurysms","volume":"42","author":"Rajah G","year":"2017","unstructured":"Rajah G, Narayanan S, Rangel-Castilla L. Update on flow diverters for the endovascular management of cerebral aneurysms. Neurosurg Focus. 2017;42(6):E2."},{"issue":"Suppl 1","key":"b2","series-title":"Neurosurgery","first-page":"S36","article-title":"Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes","volume":"86","author":"Chancellor B","year":"2020","unstructured":"Chancellor B, Raz E, Shapiro M,  Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes. Neurosurgery. 2020;86(Suppl 1):S36-S45."},{"issue":"2","key":"b3","series-title":"Stroke","first-page":"442","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji W","year":"2013","unstructured":"Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke. 2013;44(2):442\u2013447."},{"issue":"4","key":"b4","series-title":"Neuroradiology","first-page":"391","article-title":"Flow diverter treatment of posterior circulation aneurysms. A meta-analysis","volume":"58","author":"Wang CB","year":"2016","unstructured":"Wang CB, Shi WW, Zhang GX, Lu HC, Ma J. Flow diverter treatment of posterior circulation aneurysms. A meta-analysis. Neuroradiology. 2016;58(4):391\u2013400."},{"issue":"9","key":"b5","series-title":"J Neurointerv Surg","first-page":"898","article-title":"Long-term outcomes of flow diversion for unruptured intracranial aneurysms: a systematic review and meta-analysis","volume":"15","author":"Shehata MA","year":"2023","unstructured":"Shehata MA, Ibrahim MK, Ghozy S,  Long-term outcomes of flow diversion for unruptured intracranial aneurysms: a systematic review and meta-analysis. J Neurointerv Surg. 2023;15(9):898\u2013902."},{"issue":"6","key":"b6","series-title":"Neurosurg Focus","first-page":"E3","article-title":"Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center","volume":"42","author":"Briganti F","year":"2017","unstructured":"Briganti F, Leone G, Cirillo L, de Divitiis O, Solari D, Cappabianca P. Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center. Neurosurg Focus. 2017;42(6):E3."},{"issue":"2","key":"b7","series-title":"Neurosurg Clin N Am","first-page":"215","article-title":"Novel innovation in flow diversion: surface modifications","volume":"33","author":"Hudson JS","year":"2022","unstructured":"Hudson JS, Lang MJ, Gross BA. Novel innovation in flow diversion: surface modifications. Neurosurg Clin N Am. 2022;33(2):215\u2013218."},{"key":"b8","series-title":"Interv Neuroradiol. Published online October","article-title":"Flow diverter surface modifications for aneurysm treatment: a review of the mechanisms and data behind existing technologies","volume":"29,","author":"White TG","year":"2023","unstructured":"White TG, Santhumayor BA, Turpin J,  Flow diverter surface modifications for aneurysm treatment: a review of the mechanisms and data behind existing technologies. Interv Neuroradiol. Published online October 29,2023. doi:10.1177\/15910199231207550"},{"issue":"3","key":"b9","series-title":"Interv Neuroradiol","first-page":"350","article-title":"Treatment of ruptured intracranial aneurysms using the novel generation of flow-diverters with surface modification: a systematic review and meta-analysis","volume":"30","author":"Monteiro A","year":"2024","unstructured":"Monteiro A, Khan A, Donnelly BM,  Treatment of ruptured intracranial aneurysms using the novel generation of flow-diverters with surface modification: a systematic review and meta-analysis. Interv Neuroradiol. 2024;30(3):350\u2013360."},{"key":"b10","series-title":"World Neurosurg","first-page":"e184","article-title":"First U.S. experience using the Pipeline Flex Embolization Device with Shield technology for treatment of intracranial aneurysms","volume":"159","author":"Cappuzzo JM","year":"2022","unstructured":"Cappuzzo JM, Monteiro A, Taylor MN,  First U.S. experience using the Pipeline Flex Embolization Device with Shield technology for treatment of intracranial aneurysms. World Neurosurg. 2022;159:e184\u2013e191."},{"issue":"6","key":"b11","series-title":"Neuroradiology","first-page":"1213","article-title":"Efficacy of the Flow Re-direction Endoluminal Device for cerebral aneurysms and causes of failed deployment","volume":"64","author":"Suyama K","year":"2022","unstructured":"Suyama K, Nakahara I, Matsumoto S,  Efficacy of the Flow Re-direction Endoluminal Device for cerebral aneurysms and causes of failed deployment. Neuroradiology. 2022;64(6):1213\u20131219."},{"issue":"3","key":"b12","series-title":"Interv Neuroradiol","first-page":"347","article-title":"Flow redirection endoluminal device (FRED) for treatment of intracranial aneurysms: a systematic review","volume":"28","author":"Waqas M","year":"2022","unstructured":"Waqas M, Dossani RH, Alkhaldi M,  Flow redirection endoluminal device (FRED) for treatment of intracranial aneurysms: a systematic review. Interv Neuroradiol. 2022;28(3):347\u2013357."},{"issue":"6","key":"b13","series-title":"AJNR Am J Neuroradiol","first-page":"1155","article-title":"The FRED flow-diverter stent for intracranial aneurysms: clinical study to assess safety and efficacy","volume":"36","author":"M\u00f6hlenbruch MA","year":"2015","unstructured":"M\u00f6hlenbruch MA, Herweh C, Jestaedt L,  The FRED flow-diverter stent for intracranial aneurysms: clinical study to assess safety and efficacy. AJNR Am J Neuroradiol. 2015;36(6):1155\u20131161."},{"issue":"2","key":"b14","series-title":"J Neurointerv Surg","first-page":"153","article-title":"Comparison of PED and FRED flow diverters for posterior circulation aneurysms: a propensity score matched cohort study","volume":"13","author":"Griessenauer CJ","year":"2021","unstructured":"Griessenauer CJ, Enriquez-Marulanda A, Xiang S,  Comparison of PED and FRED flow diverters for posterior circulation aneurysms: a propensity score matched cohort study. J Neurointerv Surg. 2021;13(2):153\u2013158."},{"issue":"2","key":"b15","series-title":"Neurosurgery","first-page":"E249","article-title":"Comparison of Pipeline Embolization Device and Flow Re-Direction Endoluminal Device flow diverters for internal carotid artery aneurysms: a propensity score-matched cohort study","volume":"85","author":"Griessenauer CJ","year":"2019","unstructured":"Griessenauer CJ, Thomas AJ, Enriquez-Marulanda A,  Comparison of Pipeline Embolization Device and Flow Re-Direction Endoluminal Device flow diverters for internal carotid artery aneurysms: a propensity score-matched cohort study. Neurosurgery. 2019;85(2):E249\u2013E255."},{"key":"b16","series-title":"Interv Neuroradiol","article-title":"Comparison of pipeline embolization device, flow re-direction endoluminal device and surpass flow diverters in the treatment of intracerebral aneurysms","author":"Field NC","unstructured":"Field NC, Custozzo A, Gajjar AA, Dalfino JC, Boulos AS, Paul AR. Comparison of pipeline embolization device, flow re-direction endoluminal device and surpass flow diverters in the treatment of intracerebral aneurysms. Interv Neuroradiol. Published online August 27, 2023. doi:10.1177\/15910199231196621"},{"issue":"e1","key":"b17","series-title":"J Neurointerv Surg","first-page":"e159","article-title":"Flow diverter stents for endovascular treatment of aneurysms: a comparative study of efficacy and safety between FREDX and FRED","volume":"17","author":"Guimaraens L","year":"2024","unstructured":"Guimaraens L, Salda\u00f1a J, Vivas E,  Flow diverter stents for endovascular treatment of aneurysms: a comparative study of efficacy and safety between FREDX and FRED. J Neurointerv Surg. 2024;17(e1):e159\u2013e165."},{"issue":"3","key":"b18","series-title":"Radiology","first-page":"858","article-title":"Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial","volume":"267","author":"Becske T","year":"2013","unstructured":"Becske T, Kallmes DF, Saatci I,  Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology. 2013;267(3):858\u2013868."},{"issue":"1","key":"b19","series-title":"AJNR Am J Neuroradiol","first-page":"34","article-title":"The pipeline embolization device for the intracranial treatment of aneurysms trial","volume":"32","author":"Nelson PK","year":"2011","unstructured":"Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D. The pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol. 2011;32(1):34\u201340."},{"issue":"1","key":"b20","series-title":"Neurosurgery","first-page":"118","article-title":"Comparison of Flow-Redirection Endoluminal Device and Pipeline Embolization Device in the treatment of intracerebral aneurysms","volume":"92","author":"El Naamani K","year":"2023","unstructured":"El Naamani K, Saad H, Chen CJ,  Comparison of Flow-Redirection Endoluminal Device and Pipeline Embolization Device in the treatment of intracerebral aneurysms. Neurosurgery. 2023;92(1):118\u2013124."},{"issue":"3","key":"b21","series-title":"Interv Neuroradiol","first-page":"302","article-title":"Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms","volume":"28","author":"G\u00fcndo\u011fmu\u015f CA","year":"2022","unstructured":"G\u00fcndo\u011fmu\u015f CA, Sabet S, Baltac\u0131o\u011flu NA, T\u00fcreli D, Bayri Y, Baltac\u0131o\u011flu F. Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms. Interv Neuroradiol. 2022;28(3):302\u2013310."},{"issue":"4","key":"b22","series-title":"J Neurosurg","first-page":"1054","article-title":"First United States multicenter experience with the new-generation FRED X surface-modified flow diversion stent: feasibility, safety, and short-term efficacy","volume":"140","author":"Abbas R","year":"2023","unstructured":"Abbas R, Lan M, Naamani KE,  First United States multicenter experience with the new-generation FRED X surface-modified flow diversion stent: feasibility, safety, and short-term efficacy. J Neurosurg. 2023;140(4):1054\u20131063."},{"issue":"4","key":"b23","series-title":"AJNR Am J Neuroradiol","first-page":"474","article-title":"The FRESH Study: treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology\u2014first multicenter experience in 161 patients","volume":"44","author":"Vollherbst DF","year":"2023","unstructured":"Vollherbst DF, L\u00fccking H, DuPlessis J,  The FRESH Study: treatment of intracranial aneurysms with the new FRED X flow diverter with antithrombotic surface treatment technology\u2014first multicenter experience in 161 patients. AJNR Am J Neuroradiol. 2023;44(4):474\u2013480."},{"issue":"2","key":"b24","series-title":"J Neurointerv Surg","first-page":"184","article-title":"SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results","volume":"11","author":"Pierot L","year":"2019","unstructured":"Pierot L, Spelle L, Berge J,  SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results. J Neurointerv Surg. 2019;11(2):184\u2013189."},{"issue":"11","key":"b25","series-title":"J Neurointerv Surg","first-page":"1107","article-title":"Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study","volume":"12","author":"Rice H","year":"2020","unstructured":"Rice H, Mart\u00ednez Gald\u00e1mez M, Holtmannsp\u00f6tter M,  Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study. J Neurointerv Surg. 2020;12(11):1107\u20131112."},{"issue":"7","key":"b26","series-title":"J Neurointerv Surg","first-page":"694","article-title":"Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience","volume":"11","author":"Manning NW","year":"2019","unstructured":"Manning NW, Cheung A, Phillips TJ, Wenderoth JD. Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience. J Neurointerv Surg. 2019;11(7):694\u2013698."},{"issue":"8","key":"b27","series-title":"J Neurointerv Surg","first-page":"772","article-title":"Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study","volume":"9","author":"Mart\u00ednez-Gald\u00e1mez M","year":"2017","unstructured":"Mart\u00ednez-Gald\u00e1mez M, Lamin SM, Lagios KG,  Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study. J Neurointerv Surg. 2017;9(8):772\u2013776."},{"issue":"6","key":"b28","series-title":"Neuroradiology","first-page":"943","article-title":"Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study","volume":"63","author":"Dinc H","year":"2021","unstructured":"Dinc H, Saatci I, Oguz S,  Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study. Neuroradiology. 2021;63(6):943\u2013952."},{"issue":"5","key":"b29","series-title":"AJNR Am J Neuroradiol","first-page":"841","article-title":"European multicenter study for the evaluation of a dual-layer flow-diverting stent for treatment of wide-neck intracranial aneurysms: the European Flow-Redirection Intraluminal Device Study","volume":"39","author":"Killer-Oberpfalzer M","year":"2018","unstructured":"Killer-Oberpfalzer M, Kocer N, Griessenauer CJ,  European multicenter study for the evaluation of a dual-layer flow-diverting stent for treatment of wide-neck intracranial aneurysms: the European Flow-Redirection Intraluminal Device Study. AJNR Am J Neuroradiol. 2018;39(5):841\u2013847."},{"issue":"1","key":"b30","series-title":"J Neurosurg","first-page":"174","article-title":"FRED Italian Registry: a multicenter experience with the flow re-direction endoluminal device for intracranial aneurysms","volume":"133","author":"Piano M","year":"2019","unstructured":"Piano M, Valvassori L, Lozupone E,  FRED Italian Registry: a multicenter experience with the flow re-direction endoluminal device for intracranial aneurysms. J Neurosurg. 2019;133(1):174\u2013181."},{"issue":"6","key":"b31","series-title":"Neuroradiol J","first-page":"471","article-title":"Pipeline Flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes","volume":"33","author":"Yeomans J","year":"2020","unstructured":"Yeomans J, Sandu L, Sastry A. Pipeline Flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes. Neuroradiol J. 2020;33(6):471\u2013478."},{"issue":"4","key":"b32","series-title":"J Neurointerv Surg","first-page":"407","article-title":"Diffusion weighted image documented cerebral ischemia in the postprocedural period following pipeline embolization device with shield technology treatment of unruptured intracranial aneurysms: a prospective, single center study","volume":"12","author":"Pikis S","year":"2020","unstructured":"Pikis S, Mantziaris G, Mamalis V,  Diffusion weighted image documented cerebral ischemia in the postprocedural period following pipeline embolization device with shield technology treatment of unruptured intracranial aneurysms: a prospective, single center study. J Neurointerv Surg. 2020;12(4):407\u2013411."},{"issue":"12","key":"b33","series-title":"AJNR Am J Neuroradiol","first-page":"2094","article-title":"Outcome study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU)","volume":"40","author":"Atasoy D","year":"2019","unstructured":"Atasoy D, Kandasamy N, Hart J,  Outcome study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU). AJNR Am J Neuroradiol. 2019;40(12):2094\u20132101."},{"issue":"1","key":"b34","series-title":"Neurosurgery","first-page":"104","article-title":"Safety and effectiveness of the Pipeline Flex Embolization Device with Shield technology for the treatment of intracranial aneurysms: midterm results from a multicenter study","volume":"87","author":"Trivelato FP","year":"2020","unstructured":"Trivelato FP, Wajnberg E, Rezende MTS,  Safety and effectiveness of the Pipeline Flex Embolization Device with Shield technology for the treatment of intracranial aneurysms: midterm results from a multicenter study. Neurosurgery. 2020;87(1):104\u2013111."},{"issue":"5","key":"b35","series-title":"Neurosurg Focus","first-page":"E7","article-title":"Safety and efficacy of the p48 MW and p64 flow modulation devices: a systematic review and meta-analysis","volume":"54","author":"Vivanco-Suarez J","year":"2023","unstructured":"Vivanco-Suarez J, Salem MM, Sioutas GS,  Safety and efficacy of the p48 MW and p64 flow modulation devices: a systematic review and meta-analysis. Neurosurg Focus. 2023;54(5):E7."},{"issue":"1","key":"b36","series-title":"J Neurointerv Surg","first-page":"62","article-title":"Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results","volume":"12","author":"Hanel RA","year":"2020","unstructured":"Hanel RA, Kallmes DF, Lopes DK,  Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results. J Neurointerv Surg. 2020;12(1):62\u201366."},{"issue":"8","key":"b37","series-title":"J Neurointerv Surg","first-page":"765","article-title":"Feasibility, complications, morbidity, and mortality results at 6 months for aneurysm treatment with the Flow Re-Direction Endoluminal Device: report of SAFE study","volume":"10","author":"Pierot L","year":"2018","unstructured":"Pierot L, Spelle L, Berge J,  Feasibility, complications, morbidity, and mortality results at 6 months for aneurysm treatment with the Flow Re-Direction Endoluminal Device: report of SAFE study. J Neurointerv Surg. 2018;10(8):765\u2013770."},{"issue":"2","key":"b38","series-title":"Neurosurgery","first-page":"330","article-title":"Comparison of thromboembolic events between Pipeline Embolization Device (PED) Shield and PED\/PED Flex: a propensity score-matched analysis","volume":"95","author":"Ramirez-Velandia F","year":"2024","unstructured":"Ramirez-Velandia F, Enriquez-Marulanda A, Filo J,  Comparison of thromboembolic events between Pipeline Embolization Device (PED) Shield and PED\/PED Flex: a propensity score-matched analysis. Neurosurgery. 2024;95(2):330\u2013338."},{"issue":"2","key":"b39","series-title":"J Neurosurg","first-page":"436","article-title":"Comparison of PED\/PED Flex and PED Shield in the treatment of unruptured intracerebral aneurysms","volume":"140","author":"El Naamani K","year":"2023","unstructured":"El Naamani K, Mastorakos P, Yudkoff CJ,  Comparison of PED\/PED Flex and PED Shield in the treatment of unruptured intracerebral aneurysms. J Neurosurg. 2023;140(2):436\u2013440."},{"issue":"2","key":"b40","series-title":"J Neurointerv Surg","first-page":"166","article-title":"Transient in-stent stenosis at mid-term angiographic follow-up in patients treated with SILK flow diverter stents: incidence, clinical significance and long-term follow-up","volume":"11","author":"Essbaiheen F","year":"2019","unstructured":"Essbaiheen F, AlQahtani H, Almansoori TM,  Transient in-stent stenosis at mid-term angiographic follow-up in patients treated with SILK flow diverter stents: incidence, clinical significance and long-term follow-up. J Neurointerv Surg. 2019;11(2):166\u2013170."},{"issue":"9378","key":"b41","series-title":"Lancet","first-page":"103","article-title":"Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment","volume":"362","author":"Wiebers DO","year":"2003","unstructured":"Wiebers DO, Whisnant JP, Huston J III,  Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet. 2003;362(9378):103\u2013110."},{"issue":"5","key":"b42","series-title":"J Neuroradiol","first-page":"336","article-title":"Unruptured intracranial aneurysms","volume":"30","author":"White PM","year":"2003","unstructured":"White PM, Wardlaw JM. Unruptured intracranial aneurysms. J Neuroradiol. 2003;30(5):336\u2013350."},{"issue":"2","key":"b43","series-title":"J Neurosurg","first-page":"310","article-title":"The natural history of aneurysms incompletely occluded by placement of a flow diverter: a multiinstitutional study","volume":"141","author":"Theiss P","year":"2024","unstructured":"Theiss P, Ali AE, McGuire LS,  The natural history of aneurysms incompletely occluded by placement of a flow diverter: a multiinstitutional study. J Neurosurg. 2024;141(2):310\u2013315."},{"issue":"6","key":"b44","series-title":"Neurosurg Focus","first-page":"E4","article-title":"Off-label uses of the Pipeline embolization device: a review of the literature","volume":"42","author":"Patel PD","year":"2017","unstructured":"Patel PD, Chalouhi N, Atallah E,  Off-label uses of the Pipeline embolization device: a review of the literature. Neurosurg Focus. 2017;42(6):E4."},{"issue":"5","key":"b45","series-title":"Stroke","first-page":"1428","article-title":"ARISE I consensus review on the management of intracranial aneurysms","volume":"55","author":"Tjoumakaris SI","year":"2024","unstructured":"Tjoumakaris SI, Hanel R, Mocco J,  ARISE I consensus review on the management of intracranial aneurysms. Stroke. 2024;55(5):1428\u20131437."},{"issue":"2","key":"b46","series-title":"Interv Neuroradiol","first-page":"133","article-title":"A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents","volume":"16","author":"O\u2019Kelly CJ","year":"2010","unstructured":"O\u2019Kelly CJ, Krings T, Fiorella D, Marotta TR. A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol. 2010;16(2):133\u2013137."}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/143\/1\/article-p232.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/143\/1\/article-p232.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/143\/1\/article-p232.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T14:27:53Z","timestamp":1772720873000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/143\/1\/article-p232.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,1]]},"references-count":92,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3171\/2024.10.jns241233","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,1]]}}}