{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T04:45:47Z","timestamp":1784004347425,"version":"3.55.0"},"reference-count":68,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,12,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Robot-assisted (RA) technology is becoming more widely integrated and accepted in spine surgery. The authors sought to evaluate operative and patient-reported outcomes (PROs) in RA versus fluoroscopy-assisted (FA) pedicle screw placement during minimally invasive surgery (MIS) transforaminal lumbar interbody fusion (TLIF).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>The authors retrospectively studied elective patients who underwent single- or multilevel MIS TLIF for degenerative indication using FA versus RA pedicle screw placement. Patients were selected from September 2021 to May 2023 at a single institution with multiple surgeons whose practice consists of primarily MIS. Outcomes included fluoroscopy dosage per screw, operative time per screw, anesthesia time per screw, estimated blood loss (EBL), screw revision rate, inpatient surgical complications, and minimal clinically important difference (MCID) of Oswestry Disability Index (ODI) and numeric rating scale (NRS) scores at the 6- and 12-month follow-ups. Comparability of groups was analyzed by univariate analysis. Multivariable analysis modeling fluoroscopy time per screw was performed, adjusting for confounders.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>One hundred eighty-three patients (n = 133 in the FA group vs 50 in the RA group) were included. Patients in the RA cohort were significantly younger than those in the FA group (mean age 63.8 \u00b1 11.9 vs 59.8 \u00b1 11.0 years, p = 0.037). A total of 932 pedicle screws were placed (mean 5.1, range 4\u20138 per patient). The RA cohort demonstrated significantly lower intraoperative fluoroscopy dosage per screw (4.9 \u00b1 7.6 mGy per screw vs 20.3 \u00b1 14.0 mGy per screw, p &lt; 0.001), significantly longer anesthesia time per screw (49.1 \u00b1 12.6 vs 43.6 \u00b1 9.2, p = 0.009), and similar operative time per screw (33.3 vs 30.7 minutes, p = 0.125). The screw revision rate for symptomatic radiculopathy was zero in both groups. Revision surgery requiring screw removal or reposition was performed in 4 total cases (RA group: 1\/50 for infection; FA group: 2\/133 for infection, 1\/133 for foraminotomy). Both groups demonstrated significant improvement in PROs at 6 and 12 months compared with preoperatively. Moreover, both groups achieved MCID at similar rates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>When implementing RA technology, one can expect similar perioperative outcomes as FA techniques in addition to significantly lower radiation exposure. Moreover, there is no statistically significant difference in postoperative PROs between RA and FA. Longer anesthesia times may also be encountered, as in this study, which is likely a result of more complex robotic setup and workflow.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2024.9.focus24489","type":"journal-article","created":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T08:25:04Z","timestamp":1733041504000},"page":"E11","source":"Crossref","is-referenced-by-count":8,"title":["Irradiation safety, anesthesia time, surgical complications, and patient-reported outcomes in the robotic Mazor X versus fluoroscopy guided minimally invasive transforaminal lumbar interbody fusion surgery: a comparative cohort study"],"prefix":"10.3171","volume":"57","author":[{"given":"Daniel W.","family":"Griepp","sequence":"first","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua","family":"Caskey","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Armando","family":"Bunjaj","sequence":"additional","affiliation":[{"name":"Department of Medical Education, Lake Erie College of Medicine, Erie, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey","family":"Turnbull","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ammar","family":"Alsalahi","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hepzibha","family":"Alexander","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Dragonette","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryce","family":"Sarcar","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shivum","family":"Desai","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doris","family":"Tong","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teck M.","family":"Soo","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Bono","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prashant","family":"Kelkar","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clifford","family":"Houseman","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chad F.","family":"Claus","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyd F.","family":"Richards","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel A.","family":"Carr","sequence":"additional","affiliation":[{"name":"Division of Neurosurgery, Henry Ford Providence Hospital, Southfield, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"5","key":"b1","series-title":"Eur Spine J","first-page":"1017","article-title":"Minimally invasive versus open transforaminal lumbar interbody fusion for treatment of degenerative lumbar disease: systematic review and meta-analysis","volume":"24","author":"Phan K","year":"2015","unstructured":"Phan K, Rao PJ, Kam AC, Mobbs RJ. Minimally invasive versus open transforaminal lumbar interbody fusion for treatment of degenerative lumbar disease: systematic review and meta-analysis. Eur Spine J. 2015;24(5):1017\u20131030."},{"issue":"5","key":"b2","series-title":"J Neurosurg Sci","first-page":"391","article-title":"The evolving neurosurgical perspective on Enhanced Recovery After Surgery (ERAS): a systematic review","volume":"66","author":"Fiani B","year":"2022","unstructured":"Fiani B, Griepp DW, Kurien L,  The evolving neurosurgical perspective on Enhanced Recovery After Surgery (ERAS): a systematic review. J Neurosurg Sci. 2022;66(5):391\u2013398."},{"issue":"5","key":"b3","series-title":"J Neurosurg Spine","first-page":"503","article-title":"Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? Presented at the 2009 Joint Spine Section Meeting","volume":"12","author":"Brasiliense LBC","year":"2010","unstructured":"Brasiliense LBC, Theodore N, Lazaro BCR,  Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? Presented at the 2009 Joint Spine Section Meeting. J Neurosurg Spine. 2010;12(5):503\u2013508."},{"issue":"2","key":"b4","series-title":"Spine J","first-page":"193","article-title":"A cost benefit analysis of increasing surgical technology in lumbar spine fusion","volume":"21","author":"Passias PG","year":"2021","unstructured":"Passias PG, Brown AE, Alas H,  A cost benefit analysis of increasing surgical technology in lumbar spine fusion. Spine J. 2021;21(2):193\u2013201."},{"key":"b5","series-title":"World Neurosurg","first-page":"e570","article-title":"Perioperative comparison of robotic-assisted versus fluoroscopically guided minimally invasive transforaminal lumbar interbody fusion","volume":"149","author":"De Biase G","year":"2021","unstructured":"De Biase G, Gassie K, Garcia D,  Perioperative comparison of robotic-assisted versus fluoroscopically guided minimally invasive transforaminal lumbar interbody fusion. World Neurosurg. 2021;149:e570\u2013e575."},{"issue":"5","key":"b6","series-title":"Global Spine J","first-page":"1464","article-title":"Comparison of safety and perioperative outcomes between patient-specific template-guided and fluoroscopic-assisted freehand lumbar screw placement using cortical bone trajectory technique","volume":"14","author":"Matsukawa K","year":"2024","unstructured":"Matsukawa K, Kaito T, Abe Y. Comparison of safety and perioperative outcomes between patient-specific template-guided and fluoroscopic-assisted freehand lumbar screw placement using cortical bone trajectory technique. Global Spine J. 2024;14(5):1464\u20131471."},{"issue":"2","key":"b7","series-title":"Int J Med Robot","first-page":"e2188","article-title":"Fluoroscopy time analysis of a prospective, multi-centre study comparing robotic- and fluoroscopic-guided placement of percutaneous pedicle screw instrumentation for short segment minimally invasive lumbar fusion surgery","volume":"17","author":"Jamshidi AM","year":"2021","unstructured":"Jamshidi AM, Massel DH, Liounakos JI,  Fluoroscopy time analysis of a prospective, multi-centre study comparing robotic- and fluoroscopic-guided placement of percutaneous pedicle screw instrumentation for short segment minimally invasive lumbar fusion surgery. Int J Med Robot. 2021;17(2):e2188."},{"issue":"4","key":"b8","series-title":"Oper Neurosurg (Hagerstown)","first-page":"389","article-title":"A quantitative assessment of the accuracy and reliability of robotically guided percutaneous pedicle screw placement: technique and application accuracy","volume":"17","author":"Godzik J","year":"2019","unstructured":"Godzik J, Walker CT, Hartman C,  A quantitative assessment of the accuracy and reliability of robotically guided percutaneous pedicle screw placement: technique and application accuracy. Oper Neurosurg (Hagerstown). 2019;17(4):389\u2013395."},{"issue":"2","key":"b9","series-title":"Neurosurgery","first-page":"N20","article-title":"Evaluating the accuracy of robotic assistance in spine surgery","volume":"71","author":"Cahill KS","year":"2012","unstructured":"Cahill KS, Wang MY. Evaluating the accuracy of robotic assistance in spine surgery. Neurosurgery. 2012;71(2):N20\u2013N21."},{"issue":"1","key":"b10","series-title":"Syst Rev","first-page":"170","article-title":"Comparison of robot-assisted versus fluoroscopy-guided transforaminal lumbar interbody fusion (TLIF) for lumbar degenerative diseases: a systematic review and meta-analysis of randomized controlled trails and cohort studies","volume":"13","author":"Guan J","year":"2024","unstructured":"Guan J, Feng N, Yu X, Yang K. Comparison of robot-assisted versus fluoroscopy-guided transforaminal lumbar interbody fusion (TLIF) for lumbar degenerative diseases: a systematic review and meta-analysis of randomized controlled trails and cohort studies. Syst Rev. 2024;13(1):170."},{"issue":"3","key":"b11","series-title":"J Robot Surg","first-page":"431","article-title":"Navigated robotic assistance results in improved screw accuracy and positive clinical outcomes: an evaluation of the first 54 cases","volume":"14","author":"Benech CA","year":"2020","unstructured":"Benech CA, Perez R, Benech F, Greeley SL, Crawford N, Ledonio C. Navigated robotic assistance results in improved screw accuracy and positive clinical outcomes: an evaluation of the first 54 cases. J Robot Surg. 2020;14(3):431\u2013437."},{"issue":"18","key":"b12","series-title":"Spine (Phila Pa 1976)","first-page":"1279","article-title":"Robotics reduces radiation exposure in minimally invasive lumbar fusion compared with navigation","volume":"47","author":"Shahi P","year":"2022","unstructured":"Shahi P, Vaishnav A, Araghi K,  Robotics reduces radiation exposure in minimally invasive lumbar fusion compared with navigation. Spine (Phila Pa 1976). 2022;47(18):1279\u20131286."},{"issue":"1","key":"b13","series-title":"Spine (Phila Pa 1976)","first-page":"1","article-title":"Radiation exposure in minimally invasive lumbar fusion surgery: a randomized controlled trial comparing conventional fluoroscopy and 3D fluoroscopy-based navigation","volume":"46","author":"Klingler JH","year":"2021","unstructured":"Klingler JH, Scholz C, Kr\u00fcger MT,  Radiation exposure in minimally invasive lumbar fusion surgery: a randomized controlled trial comparing conventional fluoroscopy and 3D fluoroscopy-based navigation. Spine (Phila Pa 1976). 2021;46(1):1\u20138."},{"issue":"12","key":"b14","series-title":"Int J Surg","first-page":"1495","article-title":"The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement: guidelines for reporting observational studies","volume":"12","author":"von Elm E","year":"2014","unstructured":"von Elm E, Altman DG, Egger M, Pocock SJ, G\u00f8tzsche PC, Vandenbroucke JP. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement: guidelines for reporting observational studies. Int J Surg. 2014;12(12):1495\u20131499."},{"issue":"2","key":"b15","series-title":"Qual Life Res","first-page":"283","article-title":"Is the Oswestry Disability Index a valid measure of response to sacroiliac joint treatment","volume":"25","author":"Copay AG","year":"2016","unstructured":"Copay AG, Cher DJ. Is the Oswestry Disability Index a valid measure of response to sacroiliac joint treatment? Qual Life Res. 2016;25(2):283\u2013292."},{"issue":"6","key":"b16","series-title":"Spine J","first-page":"968","article-title":"Minimum clinically important difference in lumbar spine surgery patients: a choice of methods using the Oswestry Disability Index, Medical Outcomes Study questionnaire Short Form 36, and pain scales","volume":"8","author":"Copay AG","year":"2008","unstructured":"Copay AG, Glassman SD, Subach BR, Berven S, Schuler TC, Carreon LY. Minimum clinically important difference in lumbar spine surgery patients: a choice of methods using the Oswestry Disability Index, Medical Outcomes Study questionnaire Short Form 36, and pain scales. Spine J. 2008;8(6):968\u2013974."},{"issue":"1","key":"b17","series-title":"Spine (Phila Pa 1976)","first-page":"42","article-title":"What is the comparison in robot time per screw, radiation exposure, robot abandonment, screw accuracy, and clinical outcomes between percutaneous and open robot-assisted short lumbar fusion? A multicenter, propensity-matched analysis of 310 patients","volume":"47","author":"Lee NJ","year":"2022","unstructured":"Lee NJ, Buchanan IA, Zuckermann SL,  What is the comparison in robot time per screw, radiation exposure, robot abandonment, screw accuracy, and clinical outcomes between percutaneous and open robot-assisted short lumbar fusion? A multicenter, propensity-matched analysis of 310 patients. Spine (Phila Pa 1976). 2022;47(1):42\u201348."},{"issue":"5","key":"b18","series-title":"Neurosurg Focus","first-page":"E12","article-title":"Revisions for screw malposition and clinical outcomes after robot-guided lumbar fusion for spondylolisthesis","volume":"42","author":"Schr\u00f6der ML","year":"2017","unstructured":"Schr\u00f6der ML, Staartjes VE. Revisions for screw malposition and clinical outcomes after robot-guided lumbar fusion for spondylolisthesis. Neurosurg Focus. 2017;42(5):E12."},{"issue":"24","key":"b19","series-title":"Spine (Phila Pa 1976)","first-page":"E1692","article-title":"Risk of postoperative complications and revision surgery following robot-assisted posterior lumbar spinal fusion","volume":"45","author":"Yang DS","year":"2020","unstructured":"Yang DS, Li NY, Kleinhenz DT, Patel S, Daniels AH. Risk of postoperative complications and revision surgery following robot-assisted posterior lumbar spinal fusion. Spine (Phila Pa 1976). 2020;45(24):E1692\u2013E1698."},{"issue":"23","key":"b20","series-title":"Spine (Phila Pa 1976)","first-page":"1661","article-title":"Complications and revision rates in minimally invasive robotic-guided versus fluoroscopic-guided spinal fusions: the MIS ReFRESH prospective comparative study","volume":"46","author":"Good CR","year":"2021","unstructured":"Good CR, Orosz L, Schroerlucke SR,  Complications and revision rates in minimally invasive robotic-guided versus fluoroscopic-guided spinal fusions: the MIS ReFRESH prospective comparative study. Spine (Phila Pa 1976). 2021;46(23):1661\u20131668."},{"issue":"2","key":"b21","series-title":"J Robot Surg","first-page":"473","article-title":"Comparison of robot-assisted versus fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: 2-year follow-up","volume":"17","author":"Wang L","year":"2023","unstructured":"Wang L, Li C, Wang Z,  Comparison of robot-assisted versus fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: 2-year follow-up. J Robot Surg. 2023;17(2):473\u2013485."},{"key":"b22","series-title":"World Neurosurg","first-page":"e731","article-title":"Robotic-navigated percutaneous pedicle screw placement has less facet joint violation than fluoroscopy-guided percutaneous screws","volume":"151","author":"Katsevman GA","year":"2021","unstructured":"Katsevman GA, Spencer RD, Daffner SD,  Robotic-navigated percutaneous pedicle screw placement has less facet joint violation than fluoroscopy-guided percutaneous screws. World Neurosurg. 2021;151:e731\u2013e737."},{"issue":"1","key":"b23","series-title":"Orthop Surg","first-page":"133","article-title":"Rate and risk factors of superior facet joint violation during cortical bone trajectory screw placement: a comparison of robot-assisted approach with a conventional technique","volume":"12","author":"Le XF","year":"2020","unstructured":"Le XF, Shi Z, Wang QL, Xu YF, Zhao JW, Tian W. Rate and risk factors of superior facet joint violation during cortical bone trajectory screw placement: a comparison of robot-assisted approach with a conventional technique. Orthop Surg. 2020;12(1):133\u2013140."},{"issue":"5","key":"b24","series-title":"Orthop Surg","first-page":"850","article-title":"Comparison of superior-level facet joint violations between robot-assisted percutaneous pedicle screw placement and conventional open fluoroscopic-guided pedicle screw placement","volume":"11","author":"Zhang Q","year":"2019","unstructured":"Zhang Q, Xu YF, Tian W,  Comparison of superior-level facet joint violations between robot-assisted percutaneous pedicle screw placement and conventional open fluoroscopic-guided pedicle screw placement. Orthop Surg. 2019;11(5):850\u2013856."},{"key":"b25","first-page":"106698","article-title":"Operative time and learning curve between fluoroscopy-based instrument tracking and robot-assisted instrumentation for patients undergoing minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). Clin Neurol Neurosurg","volume":"206","author":"Wang TY","year":"2021","unstructured":"Wang TY, Mehta VA, Sankey EW, Lavoie S, Abd-El-Barr MM, Yarbrough CK. Operative time and learning curve between fluoroscopy-based instrument tracking and robot-assisted instrumentation for patients undergoing minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). Clin Neurol Neurosurg. 2021;206:106698."},{"issue":"1","key":"b26","series-title":"Oper Neurosurg (Hagerstown)","first-page":"61","article-title":"Next-generation robotic spine surgery: first report on feasibility, safety, and learning curve","volume":"17","author":"Khan A","year":"2019","unstructured":"Khan A, Meyers JE, Siasios I, Pollina J. Next-generation robotic spine surgery: first report on feasibility, safety, and learning curve. Oper Neurosurg (Hagerstown). 2019;17(1):61\u201369."},{"issue":"21","key":"b27","series-title":"Spine (Phila Pa 1976)","first-page":"1517","article-title":"Surgeon experience influences robotics learning curve for minimally invasive lumbar fusion: a cumulative sum analysis","volume":"48","author":"Shahi P","year":"2023","unstructured":"Shahi P, Subramanian T, Maayan O,  Surgeon experience influences robotics learning curve for minimally invasive lumbar fusion: a cumulative sum analysis. Spine (Phila Pa 1976). 2023;48(21):1517\u20131525."},{"issue":"1","key":"b28","series-title":"Eur J Orthop Surg Traumatol","first-page":"127","article-title":"Learning curves for robotic-assisted spine surgery: an analysis of the time taken for screw insertion, robot setting, registration, and fluoroscopy","volume":"34","author":"Akazawa T","year":"2024","unstructured":"Akazawa T, Torii Y, Ueno J,  Learning curves for robotic-assisted spine surgery: an analysis of the time taken for screw insertion, robot setting, registration, and fluoroscopy. Eur J Orthop Surg Traumatol. 2024;34(1):127\u2013134."},{"issue":"6","key":"b29","series-title":"Clin Orthop Relat Res","first-page":"1839","article-title":"What is the learning curve for robotic-assisted pedicle screw placement in spine surgery","volume":"472","author":"Hu X","year":"2014","unstructured":"Hu X, Lieberman IH. What is the learning curve for robotic-assisted pedicle screw placement in spine surgery? Clin Orthop Relat Res. 2014;472(6):1839\u20131844."},{"issue":"5","key":"b30","series-title":"Neurosurg Focus","first-page":"E4","article-title":"Initial academic experience and learning curve with robotic spine instrumentation","volume":"42","author":"Urakov TM","year":"2017","unstructured":"Urakov TM, Chang KHK, Burks SS, Wang MY. Initial academic experience and learning curve with robotic spine instrumentation. Neurosurg Focus. 2017;42(5):E4."},{"key":"b31","series-title":"World Neurosurg","first-page":"e417","article-title":"Robot-assisted pedicle screw placement: learning curve experience","volume":"130","author":"Siddiqui MI","year":"2019","unstructured":"Siddiqui MI, Wallace DJ, Salazar LM, Vardiman AB. Robot-assisted pedicle screw placement: learning curve experience. World Neurosurg. 2019;130:e417\u2013e422."},{"issue":"7","key":"b32","series-title":"Global Spine J","first-page":"1871","article-title":"Clinical outcomes of robotic versus freehand pedicle screw placement after one-to three-level lumbar fusion","volume":"13","author":"Karamian BA","year":"2023","unstructured":"Karamian BA, DiMaria SL, Sawires AN,  Clinical outcomes of robotic versus freehand pedicle screw placement after one-to three-level lumbar fusion. Global Spine J. 2023;13(7):1871\u20131877."},{"issue":"3","key":"b33","series-title":"Yonsei Med J","first-page":"438","article-title":"Radiographic and clinical outcomes of robot-assisted posterior pedicle screw fixation: two-year results from a randomized controlled trial","volume":"59","author":"Park SM","year":"2018","unstructured":"Park SM, Kim HJ, Lee SY, Chang BS, Lee CK, Yeom JS. Radiographic and clinical outcomes of robot-assisted posterior pedicle screw fixation: two-year results from a randomized controlled trial. Yonsei Med J. 2018;59(3):438\u2013444."},{"issue":"6","key":"b34","series-title":"Spine (Phila Pa 1976)","first-page":"353","article-title":"Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial","volume":"42","author":"Hyun SJ","year":"2017","unstructured":"Hyun SJ, Kim KJ, Jahng TA, Kim HJ. Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial. Spine (Phila Pa 1976). 2017;42(6):353\u2013358."},{"issue":"5","key":"b1","series-title":"Eur Spine J","first-page":"1017","article-title":"Minimally invasive versus open transforaminal lumbar interbody fusion for treatment of degenerative lumbar disease: systematic review and meta-analysis","volume":"24","author":"Phan K","year":"2015","unstructured":"Phan K, Rao PJ, Kam AC, Mobbs RJ. Minimally invasive versus open transforaminal lumbar interbody fusion for treatment of degenerative lumbar disease: systematic review and meta-analysis. Eur Spine J. 2015;24(5):1017\u20131030."},{"issue":"5","key":"b2","series-title":"J Neurosurg Sci","first-page":"391","article-title":"The evolving neurosurgical perspective on Enhanced Recovery After Surgery (ERAS): a systematic review","volume":"66","author":"Fiani B","year":"2022","unstructured":"Fiani B, Griepp DW, Kurien L,  The evolving neurosurgical perspective on Enhanced Recovery After Surgery (ERAS): a systematic review. J Neurosurg Sci. 2022;66(5):391\u2013398."},{"issue":"5","key":"b3","series-title":"J Neurosurg Spine","first-page":"503","article-title":"Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? Presented at the 2009 Joint Spine Section Meeting","volume":"12","author":"Brasiliense LBC","year":"2010","unstructured":"Brasiliense LBC, Theodore N, Lazaro BCR,  Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? Presented at the 2009 Joint Spine Section Meeting. J Neurosurg Spine. 2010;12(5):503\u2013508."},{"issue":"2","key":"b4","series-title":"Spine J","first-page":"193","article-title":"A cost benefit analysis of increasing surgical technology in lumbar spine fusion","volume":"21","author":"Passias PG","year":"2021","unstructured":"Passias PG, Brown AE, Alas H,  A cost benefit analysis of increasing surgical technology in lumbar spine fusion. Spine J. 2021;21(2):193\u2013201."},{"key":"b5","series-title":"World Neurosurg","first-page":"e570","article-title":"Perioperative comparison of robotic-assisted versus fluoroscopically guided minimally invasive transforaminal lumbar interbody fusion","volume":"149","author":"De Biase G","year":"2021","unstructured":"De Biase G, Gassie K, Garcia D,  Perioperative comparison of robotic-assisted versus fluoroscopically guided minimally invasive transforaminal lumbar interbody fusion. World Neurosurg. 2021;149:e570\u2013e575."},{"issue":"5","key":"b6","series-title":"Global Spine J","first-page":"1464","article-title":"Comparison of safety and perioperative outcomes between patient-specific template-guided and fluoroscopic-assisted freehand lumbar screw placement using cortical bone trajectory technique","volume":"14","author":"Matsukawa K","year":"2024","unstructured":"Matsukawa K, Kaito T, Abe Y. Comparison of safety and perioperative outcomes between patient-specific template-guided and fluoroscopic-assisted freehand lumbar screw placement using cortical bone trajectory technique. Global Spine J. 2024;14(5):1464\u20131471."},{"issue":"2","key":"b7","series-title":"Int J Med Robot","first-page":"e2188","article-title":"Fluoroscopy time analysis of a prospective, multi-centre study comparing robotic- and fluoroscopic-guided placement of percutaneous pedicle screw instrumentation for short segment minimally invasive lumbar fusion surgery","volume":"17","author":"Jamshidi AM","year":"2021","unstructured":"Jamshidi AM, Massel DH, Liounakos JI,  Fluoroscopy time analysis of a prospective, multi-centre study comparing robotic- and fluoroscopic-guided placement of percutaneous pedicle screw instrumentation for short segment minimally invasive lumbar fusion surgery. Int J Med Robot. 2021;17(2):e2188."},{"issue":"4","key":"b8","series-title":"Oper Neurosurg (Hagerstown)","first-page":"389","article-title":"A quantitative assessment of the accuracy and reliability of robotically guided percutaneous pedicle screw placement: technique and application accuracy","volume":"17","author":"Godzik J","year":"2019","unstructured":"Godzik J, Walker CT, Hartman C,  A quantitative assessment of the accuracy and reliability of robotically guided percutaneous pedicle screw placement: technique and application accuracy. Oper Neurosurg (Hagerstown). 2019;17(4):389\u2013395."},{"issue":"2","key":"b9","series-title":"Neurosurgery","first-page":"N20","article-title":"Evaluating the accuracy of robotic assistance in spine surgery","volume":"71","author":"Cahill KS","year":"2012","unstructured":"Cahill KS, Wang MY. Evaluating the accuracy of robotic assistance in spine surgery. Neurosurgery. 2012;71(2):N20\u2013N21."},{"issue":"1","key":"b10","series-title":"Syst Rev","first-page":"170","article-title":"Comparison of robot-assisted versus fluoroscopy-guided transforaminal lumbar interbody fusion (TLIF) for lumbar degenerative diseases: a systematic review and meta-analysis of randomized controlled trails and cohort studies","volume":"13","author":"Guan J","year":"2024","unstructured":"Guan J, Feng N, Yu X, Yang K. Comparison of robot-assisted versus fluoroscopy-guided transforaminal lumbar interbody fusion (TLIF) for lumbar degenerative diseases: a systematic review and meta-analysis of randomized controlled trails and cohort studies. Syst Rev. 2024;13(1):170."},{"issue":"3","key":"b11","series-title":"J Robot Surg","first-page":"431","article-title":"Navigated robotic assistance results in improved screw accuracy and positive clinical outcomes: an evaluation of the first 54 cases","volume":"14","author":"Benech CA","year":"2020","unstructured":"Benech CA, Perez R, Benech F, Greeley SL, Crawford N, Ledonio C. Navigated robotic assistance results in improved screw accuracy and positive clinical outcomes: an evaluation of the first 54 cases. J Robot Surg. 2020;14(3):431\u2013437."},{"issue":"18","key":"b12","series-title":"Spine (Phila Pa 1976)","first-page":"1279","article-title":"Robotics reduces radiation exposure in minimally invasive lumbar fusion compared with navigation","volume":"47","author":"Shahi P","year":"2022","unstructured":"Shahi P, Vaishnav A, Araghi K,  Robotics reduces radiation exposure in minimally invasive lumbar fusion compared with navigation. Spine (Phila Pa 1976). 2022;47(18):1279\u20131286."},{"issue":"1","key":"b13","series-title":"Spine (Phila Pa 1976)","first-page":"1","article-title":"Radiation exposure in minimally invasive lumbar fusion surgery: a randomized controlled trial comparing conventional fluoroscopy and 3D fluoroscopy-based navigation","volume":"46","author":"Klingler JH","year":"2021","unstructured":"Klingler JH, Scholz C, Kr\u00fcger MT,  Radiation exposure in minimally invasive lumbar fusion surgery: a randomized controlled trial comparing conventional fluoroscopy and 3D fluoroscopy-based navigation. Spine (Phila Pa 1976). 2021;46(1):1\u20138."},{"issue":"12","key":"b14","series-title":"Int J Surg","first-page":"1495","article-title":"The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement: guidelines for reporting observational studies","volume":"12","author":"von Elm E","year":"2014","unstructured":"von Elm E, Altman DG, Egger M, Pocock SJ, G\u00f8tzsche PC, Vandenbroucke JP. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement: guidelines for reporting observational studies. Int J Surg. 2014;12(12):1495\u20131499."},{"issue":"2","key":"b15","series-title":"Qual Life Res","first-page":"283","article-title":"Is the Oswestry Disability Index a valid measure of response to sacroiliac joint treatment","volume":"25","author":"Copay AG","year":"2016","unstructured":"Copay AG, Cher DJ. Is the Oswestry Disability Index a valid measure of response to sacroiliac joint treatment? Qual Life Res. 2016;25(2):283\u2013292."},{"issue":"6","key":"b16","series-title":"Spine J","first-page":"968","article-title":"Minimum clinically important difference in lumbar spine surgery patients: a choice of methods using the Oswestry Disability Index, Medical Outcomes Study questionnaire Short Form 36, and pain scales","volume":"8","author":"Copay AG","year":"2008","unstructured":"Copay AG, Glassman SD, Subach BR, Berven S, Schuler TC, Carreon LY. Minimum clinically important difference in lumbar spine surgery patients: a choice of methods using the Oswestry Disability Index, Medical Outcomes Study questionnaire Short Form 36, and pain scales. Spine J. 2008;8(6):968\u2013974."},{"issue":"1","key":"b17","series-title":"Spine (Phila Pa 1976)","first-page":"42","article-title":"What is the comparison in robot time per screw, radiation exposure, robot abandonment, screw accuracy, and clinical outcomes between percutaneous and open robot-assisted short lumbar fusion? A multicenter, propensity-matched analysis of 310 patients","volume":"47","author":"Lee NJ","year":"2022","unstructured":"Lee NJ, Buchanan IA, Zuckermann SL,  What is the comparison in robot time per screw, radiation exposure, robot abandonment, screw accuracy, and clinical outcomes between percutaneous and open robot-assisted short lumbar fusion? A multicenter, propensity-matched analysis of 310 patients. Spine (Phila Pa 1976). 2022;47(1):42\u201348."},{"issue":"5","key":"b18","series-title":"Neurosurg Focus","first-page":"E12","article-title":"Revisions for screw malposition and clinical outcomes after robot-guided lumbar fusion for spondylolisthesis","volume":"42","author":"Schr\u00f6der ML","year":"2017","unstructured":"Schr\u00f6der ML, Staartjes VE. Revisions for screw malposition and clinical outcomes after robot-guided lumbar fusion for spondylolisthesis. Neurosurg Focus. 2017;42(5):E12."},{"issue":"24","key":"b19","series-title":"Spine (Phila Pa 1976)","first-page":"E1692","article-title":"Risk of postoperative complications and revision surgery following robot-assisted posterior lumbar spinal fusion","volume":"45","author":"Yang DS","year":"2020","unstructured":"Yang DS, Li NY, Kleinhenz DT, Patel S, Daniels AH. Risk of postoperative complications and revision surgery following robot-assisted posterior lumbar spinal fusion. Spine (Phila Pa 1976). 2020;45(24):E1692\u2013E1698."},{"issue":"23","key":"b20","series-title":"Spine (Phila Pa 1976)","first-page":"1661","article-title":"Complications and revision rates in minimally invasive robotic-guided versus fluoroscopic-guided spinal fusions: the MIS ReFRESH prospective comparative study","volume":"46","author":"Good CR","year":"2021","unstructured":"Good CR, Orosz L, Schroerlucke SR,  Complications and revision rates in minimally invasive robotic-guided versus fluoroscopic-guided spinal fusions: the MIS ReFRESH prospective comparative study. Spine (Phila Pa 1976). 2021;46(23):1661\u20131668."},{"issue":"2","key":"b21","series-title":"J Robot Surg","first-page":"473","article-title":"Comparison of robot-assisted versus fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: 2-year follow-up","volume":"17","author":"Wang L","year":"2023","unstructured":"Wang L, Li C, Wang Z,  Comparison of robot-assisted versus fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: 2-year follow-up. J Robot Surg. 2023;17(2):473\u2013485."},{"key":"b22","series-title":"World Neurosurg","first-page":"e731","article-title":"Robotic-navigated percutaneous pedicle screw placement has less facet joint violation than fluoroscopy-guided percutaneous screws","volume":"151","author":"Katsevman GA","year":"2021","unstructured":"Katsevman GA, Spencer RD, Daffner SD,  Robotic-navigated percutaneous pedicle screw placement has less facet joint violation than fluoroscopy-guided percutaneous screws. World Neurosurg. 2021;151:e731\u2013e737."},{"issue":"1","key":"b23","series-title":"Orthop Surg","first-page":"133","article-title":"Rate and risk factors of superior facet joint violation during cortical bone trajectory screw placement: a comparison of robot-assisted approach with a conventional technique","volume":"12","author":"Le XF","year":"2020","unstructured":"Le XF, Shi Z, Wang QL, Xu YF, Zhao JW, Tian W. Rate and risk factors of superior facet joint violation during cortical bone trajectory screw placement: a comparison of robot-assisted approach with a conventional technique. Orthop Surg. 2020;12(1):133\u2013140."},{"issue":"5","key":"b24","series-title":"Orthop Surg","first-page":"850","article-title":"Comparison of superior-level facet joint violations between robot-assisted percutaneous pedicle screw placement and conventional open fluoroscopic-guided pedicle screw placement","volume":"11","author":"Zhang Q","year":"2019","unstructured":"Zhang Q, Xu YF, Tian W,  Comparison of superior-level facet joint violations between robot-assisted percutaneous pedicle screw placement and conventional open fluoroscopic-guided pedicle screw placement. Orthop Surg. 2019;11(5):850\u2013856."},{"key":"b25","first-page":"106698","article-title":"Operative time and learning curve between fluoroscopy-based instrument tracking and robot-assisted instrumentation for patients undergoing minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). Clin Neurol Neurosurg","volume":"206","author":"Wang TY","year":"2021","unstructured":"Wang TY, Mehta VA, Sankey EW, Lavoie S, Abd-El-Barr MM, Yarbrough CK. Operative time and learning curve between fluoroscopy-based instrument tracking and robot-assisted instrumentation for patients undergoing minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). Clin Neurol Neurosurg. 2021;206:106698."},{"issue":"1","key":"b26","series-title":"Oper Neurosurg (Hagerstown)","first-page":"61","article-title":"Next-generation robotic spine surgery: first report on feasibility, safety, and learning curve","volume":"17","author":"Khan A","year":"2019","unstructured":"Khan A, Meyers JE, Siasios I, Pollina J. Next-generation robotic spine surgery: first report on feasibility, safety, and learning curve. Oper Neurosurg (Hagerstown). 2019;17(1):61\u201369."},{"issue":"21","key":"b27","series-title":"Spine (Phila Pa 1976)","first-page":"1517","article-title":"Surgeon experience influences robotics learning curve for minimally invasive lumbar fusion: a cumulative sum analysis","volume":"48","author":"Shahi P","year":"2023","unstructured":"Shahi P, Subramanian T, Maayan O,  Surgeon experience influences robotics learning curve for minimally invasive lumbar fusion: a cumulative sum analysis. Spine (Phila Pa 1976). 2023;48(21):1517\u20131525."},{"issue":"1","key":"b28","series-title":"Eur J Orthop Surg Traumatol","first-page":"127","article-title":"Learning curves for robotic-assisted spine surgery: an analysis of the time taken for screw insertion, robot setting, registration, and fluoroscopy","volume":"34","author":"Akazawa T","year":"2024","unstructured":"Akazawa T, Torii Y, Ueno J,  Learning curves for robotic-assisted spine surgery: an analysis of the time taken for screw insertion, robot setting, registration, and fluoroscopy. Eur J Orthop Surg Traumatol. 2024;34(1):127\u2013134."},{"issue":"6","key":"b29","series-title":"Clin Orthop Relat Res","first-page":"1839","article-title":"What is the learning curve for robotic-assisted pedicle screw placement in spine surgery","volume":"472","author":"Hu X","year":"2014","unstructured":"Hu X, Lieberman IH. What is the learning curve for robotic-assisted pedicle screw placement in spine surgery? Clin Orthop Relat Res. 2014;472(6):1839\u20131844."},{"issue":"5","key":"b30","series-title":"Neurosurg Focus","first-page":"E4","article-title":"Initial academic experience and learning curve with robotic spine instrumentation","volume":"42","author":"Urakov TM","year":"2017","unstructured":"Urakov TM, Chang KHK, Burks SS, Wang MY. Initial academic experience and learning curve with robotic spine instrumentation. Neurosurg Focus. 2017;42(5):E4."},{"key":"b31","series-title":"World Neurosurg","first-page":"e417","article-title":"Robot-assisted pedicle screw placement: learning curve experience","volume":"130","author":"Siddiqui MI","year":"2019","unstructured":"Siddiqui MI, Wallace DJ, Salazar LM, Vardiman AB. Robot-assisted pedicle screw placement: learning curve experience. World Neurosurg. 2019;130:e417\u2013e422."},{"issue":"7","key":"b32","series-title":"Global Spine J","first-page":"1871","article-title":"Clinical outcomes of robotic versus freehand pedicle screw placement after one-to three-level lumbar fusion","volume":"13","author":"Karamian BA","year":"2023","unstructured":"Karamian BA, DiMaria SL, Sawires AN,  Clinical outcomes of robotic versus freehand pedicle screw placement after one-to three-level lumbar fusion. Global Spine J. 2023;13(7):1871\u20131877."},{"issue":"3","key":"b33","series-title":"Yonsei Med J","first-page":"438","article-title":"Radiographic and clinical outcomes of robot-assisted posterior pedicle screw fixation: two-year results from a randomized controlled trial","volume":"59","author":"Park SM","year":"2018","unstructured":"Park SM, Kim HJ, Lee SY, Chang BS, Lee CK, Yeom JS. Radiographic and clinical outcomes of robot-assisted posterior pedicle screw fixation: two-year results from a randomized controlled trial. Yonsei Med J. 2018;59(3):438\u2013444."},{"issue":"6","key":"b34","series-title":"Spine (Phila Pa 1976)","first-page":"353","article-title":"Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial","volume":"42","author":"Hyun SJ","year":"2017","unstructured":"Hyun SJ, Kim KJ, Jahng TA, Kim HJ. Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial. Spine (Phila Pa 1976). 2017;42(6):353\u2013358."}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/57\/6\/article-pE11.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/57\/6\/article-pE11.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/57\/6\/article-pE11.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T08:29:10Z","timestamp":1779524950000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/57\/6\/article-pE11.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,1]]},"references-count":68,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2024.9.focus24489","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,1]]}}}