{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T01:38:08Z","timestamp":1780364288600,"version":"3.54.1"},"reference-count":82,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,8,8]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>The present investigation aimed to 1) develop a new CT-based assessment of endplate bone density (endplate Hounsfield unit [EP-HU]) and 2) analyze if EP-HU was a better predictor than vertebral Hounsfield unit (HU) for subsidence after anterior cervical discectomy and fusion (ACDF).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>All adult patients who underwent one- to three-level ACDF with a titanium interbody for radiculopathy and\/or myelopathy at an academic center between 2018 and 2020 were retrospectively identified. Based on preoperative sagittal CT scans (left, right, and middle cuts), 2-mm superior and inferior endplate regions were circumscribed with the free draw tool to account for endplate surface undulations. The average of the superior and inferior EP-HUs on all CT cuts was used to calculate EP-HU. Cervical vertebral HUs were determined from the average of axial CT cranial, middle, and caudal cuts circumscribing only trabecular bone. The interbody subsidence of the cranial and caudal endplates of each ACDF level was directly measured on the endplate-facing surface of both coronal and sagittal cuts of postoperative CT scans (at 1 year) to determine the maximum subsidence (subsidence defined as \u2265 2 mm). Univariate and stepwise logistic regression analyses were used to compare subsidence based on CT bone metrics. Receiver operating characteristic (ROC) curve analyses were used to determine the probability of subsidence based on EP-HUs and vertebral HUs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>A total of 35 patients were included. Subsidence occurred at 32 of 67 unique fusion levels. Subsidence was associated with older age (p = 0.008), diabetes diagnosis (p = 0.015), and decreased interbody length (p = 0.019). EP-HUs exhibited moderate correlation with cervical vertebral HUs (Pearson\u2019s \u03c1 = 0.63). Subsidence was significantly associated with decreased total EP-HUs (subsidence: 475 HU, no subsidence: 543 HU; p = 0.019) and decreased lumbar vertebral HUs (subsidence: 296 HU, no subsidence: 341 HU; p = 0.011). ROC curve analysis identified an optimal EP-HU cutoff of 512.30 (area under the curve [AUC] = 0.701) to predict subsidence. The AUC of the vertebral HUs with respect to subsidence was 0.662. EP-HUs &lt; 512.30 predicted subsidence (OR 6.67, p = 0.001) independent of significant demographic and surgical factors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>CT cervical EP-HUs rather than vertebral cervical trabecular HUs may be more efficacious in predicting subsidence after ACDF.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/2025.4.spine241067","type":"journal-article","created":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T14:34:15Z","timestamp":1757687655000},"page":"672-680","source":"Crossref","is-referenced-by-count":1,"title":["The superiority of endplate Hounsfield units relative to cervical vertebral Hounsfield units in predicting subsidence after anterior cervical discectomy and fusion"],"prefix":"10.3171","volume":"43","author":[{"given":"Hannah A.","family":"Levy","sequence":"first","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria D.","family":"Astudillo Potes","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caden J.","family":"Messer","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher A.","family":"Magera","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachariah W.","family":"Pinter","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamad","family":"Bydon","sequence":"additional","affiliation":[{"name":"Neurologic Surgery, Mayo Clinic, Rochester, Minnesota; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremy L.","family":"Fogelson","sequence":"additional","affiliation":[{"name":"Neurologic Surgery, Mayo Clinic, Rochester, Minnesota; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin D.","family":"Elder","sequence":"additional","affiliation":[{"name":"Neurologic Surgery, Mayo Clinic, Rochester, Minnesota; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bradford L.","family":"Currier","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmad N.","family":"Nassr","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brett A.","family":"Freedman","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian A.","family":"Karamian","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arjun S.","family":"Sebastian","sequence":"additional","affiliation":[{"name":"Departments of Orthopedic Surgery and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"1","key":"b1","series-title":"Surg Neurol","first-page":"66","article-title":"National trends in spinal fusion for cervical spondylotic myelopathy","volume":"71","author":"Lad SP","year":"2009","unstructured":"Lad SP, Patil CG, Berta S, Santarelli JG, Ho C, Boakye M. National trends in spinal fusion for cervical spondylotic myelopathy. Surg Neurol. 2009;71(1):66\u201369."},{"issue":"2","key":"b2","series-title":"Brain","first-page":"325","article-title":"Epidemiology of cervical radiculopathy: a population-based study from Rochester, Minnesota, 1976 through 1990","volume":"117","author":"Radhakrishnan K","year":"1994","unstructured":"Radhakrishnan K, Litchy WJ, O\u2019Fallon WM, Kurland LT. Epidemiology of cervical radiculopathy: a population-based study from Rochester, Minnesota, 1976 through 1990. Brain. 1994;117(2):325\u2013335."},{"issue":"3","key":"b3","series-title":"Global Spine J","first-page":"689","article-title":"Does facet distraction affect patient outcomes after ACDF?","volume":"13","author":"Karamian BA","year":"2023","unstructured":"Karamian BA, Levy HA, Canseco JA,  Does facet distraction affect patient outcomes after ACDF? Global Spine J. 2023;13(3):689\u2013695."},{"issue":"7","key":"b4","series-title":"J Bone Jt Surg","first-page":"941","article-title":"Anterior cervical decompression and arthrodesis for the treatment of cervical spondylotic myelopathy. Two to seventeen-year follow-up","volume":"80","author":"Emery SE","year":"1998","unstructured":"Emery SE, Bohlman HH, Bolesta MJ, Jones PK. Anterior cervical decompression and arthrodesis for the treatment of cervical spondylotic myelopathy. Two to seventeen-year follow-up. J Bone Jt Surg. 1998;80(7):941\u2013951."},{"issue":"6","key":"b5","series-title":"Spine (Phila Pa 1976)","first-page":"E365","article-title":"Surgical treatment of cervical radiculopathy","volume":"43","author":"Gutman G","year":"2018","unstructured":"Gutman G, Rosenzweig DH, Golan JD. Surgical treatment of cervical radiculopathy. Spine (Phila Pa 1976). 2018;43(6):E365\u2013E372."},{"issue":"7","key":"b6","series-title":"Global Spine J","first-page":"1703","article-title":"Titanium cervical cage subsidence: postoperative computed tomography analysis defining incidence and associated risk factors","volume":"13","author":"Pinter ZW","year":"2023","unstructured":"Pinter ZW, Reed R, Townsley SE,  Titanium cervical cage subsidence: postoperative computed tomography analysis defining incidence and associated risk factors. Global Spine J. 2023;13(7):1703\u20131715."},{"issue":"12","key":"b7","series-title":"J Clin Neurosci","first-page":"1673","article-title":"Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion: cage subsidence and cervical alignment","volume":"19","author":"Yamagata T","year":"2012","unstructured":"Yamagata T, Takami T, Uda T,  Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion: cage subsidence and cervical alignment. J Clin Neurosci. 2012;19(12):1673\u20131678."},{"issue":"8","key":"b8","series-title":"Spine (Phila Pa 1976)","first-page":"951","article-title":"Effect of endplate conditions and bone mineral density on the compressive strength of the graft\u2013endplate interface in anterior cervical spine fusion","volume":"26","author":"Lim TH","year":"2001","unstructured":"Lim TH, Kwon H, Jeon CH,  Effect of endplate conditions and bone mineral density on the compressive strength of the graft\u2013endplate interface in anterior cervical spine fusion. Spine (Phila Pa 1976). 2001;26(8):951\u2013956."},{"issue":"3","key":"b9","series-title":"Neurosurgery","first-page":"502","article-title":"Subsidence of stand-alone cervical carbon fiber cages","volume":"58","author":"Bartels RHMA","year":"2006","unstructured":"Bartels RHMA, Donk RD, Feuth T. Subsidence of stand-alone cervical carbon fiber cages. Neurosurgery. 2006;58(3):502\u2013508."},{"issue":"1","key":"b10","series-title":"Clin Orthop Surg","first-page":"16","article-title":"Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage","volume":"3","author":"Yang JJ","year":"2011","unstructured":"Yang JJ, Yu CH, Chang BS, Yeom JS, Lee JH, Lee CK. Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage. Clin Orthop Surg. 2011;3(1):16\u201323."},{"issue":"9","key":"b11","series-title":"Eur Spine J","first-page":"1395","article-title":"Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion","volume":"16","author":"Barsa P","year":"2007","unstructured":"Barsa P, Suchomel P. Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion. Eur Spine J. 2007;16(9):1395\u20131400."},{"issue":"9","key":"b12","series-title":"Clin Spine Surg","first-page":"E1239","article-title":"Graft subsidence and revision rates following anterior cervical corpectomy","volume":"30","author":"Weber MH","year":"2017","unstructured":"Weber MH, Fortin M, Shen J,  Graft subsidence and revision rates following anterior cervical corpectomy. Clin Spine Surg. 2017;30(9):E1239\u2013E1245."},{"issue":"1","key":"b13","series-title":"J Neurosurg Spine","first-page":"50","article-title":"Graft subsidence as a predictor of revision surgery following stand-alone lateral lumbar interbody fusion","volume":"28","author":"Tempel ZJ","year":"2018","unstructured":"Tempel ZJ, McDowell MM, Panczykowski DM,  Graft subsidence as a predictor of revision surgery following stand-alone lateral lumbar interbody fusion. J Neurosurg Spine. 2018;28(1):50\u201356."},{"issue":"suppl 3","key":"b14","series-title":"Eur Spine J","first-page":"414","article-title":"Impaired bone mineral density as a predictor of graft subsidence following minimally invasive transpsoas lateral lumbar interbody fusion","volume":"24","author":"Tempel ZJ","year":"2015","unstructured":"Tempel ZJ, Gandhoke GS, Okonkwo DO, Kanter AS. Impaired bone mineral density as a predictor of graft subsidence following minimally invasive transpsoas lateral lumbar interbody fusion. Eur Spine J. 2015;24(suppl 3):414-419."},{"issue":"8","key":"b15","series-title":"Global Spine J","first-page":"1723","article-title":"Allograft subsidence decreases postoperative segmental lordosis with minimal effect on global alignment following ACDF","volume":"12","author":"Pinter ZW","year":"2022","unstructured":"Pinter ZW, Mikula A, Shirley M,  Allograft subsidence decreases postoperative segmental lordosis with minimal effect on global alignment following ACDF. Global Spine J. 2022;12(8):1723\u20131730."},{"issue":"5","key":"b16","series-title":"J Neurosurg Spine","first-page":"540","article-title":"Is disc height loss at 1 year predictive of pseudarthrosis and patient-reported outcome measures following anterior cervical discectomy and fusion with structural allograft?","volume":"38","author":"D\u2019Antonio ND","year":"2023","unstructured":"D\u2019Antonio ND, Lambrechts MJ, Heard JC,  Is disc height loss at 1 year predictive of pseudarthrosis and patient-reported outcome measures following anterior cervical discectomy and fusion with structural allograft? J Neurosurg Spine. 2023;38(5):540\u2013546."},{"issue":"5","key":"b17","series-title":"Eur Spine J","first-page":"513","article-title":"Subsidence of stand-alone cervical cages in anterior interbody fusion: warning","volume":"12","author":"Gercek E","year":"2003","unstructured":"Gercek E, Arlet V, Delisle J, Marchesi D. Subsidence of stand-alone cervical cages in anterior interbody fusion: warning. Eur Spine J. 2003;12(5):513\u2013516."},{"issue":"4","key":"b18","series-title":"J Neurosurg Spine","first-page":"463","article-title":"Transforaminal lumbar interbody fusion subsidence: computed tomography analysis of incidence, associated risk factors, and impact on outcomes","volume":"41","author":"Levy HA","year":"2024","unstructured":"Levy HA, Pinter ZW, Reed R,  Transforaminal lumbar interbody fusion subsidence: computed tomography analysis of incidence, associated risk factors, and impact on outcomes. J Neurosurg Spine. 2024;41(4):463\u2013472."},{"issue":"2","key":"b19","series-title":"J Spinal Disord Tech","first-page":"87","article-title":"Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion","volume":"26","author":"Kim MC","year":"2013","unstructured":"Kim MC, Chung HT, Cho JL, Kim DJ, Chung NS. Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion. J Spinal Disord Tech. 2013;26(2):87\u201392."},{"issue":"22","key":"b20","series-title":"Spine (Phila Pa 1976)","first-page":"2441","article-title":"Effects of disc height and distractive forces on graft compression in an anterior cervical discectomy model","volume":"27","author":"Truumees E","year":"2002","unstructured":"Truumees E, Demetropoulos CK, Yang KH, Herkowitz HN. Effects of disc height and distractive forces on graft compression in an anterior cervical discectomy model. Spine (Phila Pa 1976). 2002;27(22):2441\u20132445."},{"issue":"2","key":"b21","series-title":"Neurosurg Focus","first-page":"E9","article-title":"Lumbar disc height and vertebral Hounsfield units: association with interbody cage subsidence","volume":"49","author":"Pisano AJ","year":"2020","unstructured":"Pisano AJ, Fredericks DR, Steelman T, Riccio C, Helgeson MD, Wagner SC. Lumbar disc height and vertebral Hounsfield units: association with interbody cage subsidence. Neurosurg Focus. 2020;49(2):E9."},{"issue":"9","key":"b22","series-title":"Acta Neurochir (Wien)","first-page":"2557","article-title":"Risk factors for polyetheretherketone cage subsidence following minimally invasive transforaminal lumbar interbody fusion","volume":"163","author":"Singhatanadgige W","year":"2021","unstructured":"Singhatanadgige W, Sukthuayat A, Tanaviriyachai T,  Risk factors for polyetheretherketone cage subsidence following minimally invasive transforaminal lumbar interbody fusion. Acta Neurochir (Wien). 2021;163(9):2557\u20132565."},{"issue":"1","key":"b23","series-title":"BMC Musculoskelet Disord","first-page":"882","article-title":"The value of Hounsfield units in predicting cage subsidence after transforaminal lumbar interbody fusion","volume":"23","author":"Xie F","year":"2022","unstructured":"Xie F, Yang Z, Tu Z,  The value of Hounsfield units in predicting cage subsidence after transforaminal lumbar interbody fusion. BMC Musculoskelet Disord. 2022;23(1):882."},{"issue":"1","key":"b24","series-title":"Sci Rep","first-page":"1620","article-title":"CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion","volume":"13","author":"Yao YC","year":"2023","unstructured":"Yao YC, Chao H, Kao KY,  CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion. Sci Rep. 2023;13(1):1620."},{"issue":"6","key":"b25","series-title":"Rheumatology (Oxford)","first-page":"968","article-title":"Friend or foe: high bone mineral density on routine bone density scanning, a review of causes and management","volume":"52","author":"Gregson CL","year":"2013","unstructured":"Gregson CL, Hardcastle SA, Cooper C, Tobias JH. Friend or foe: high bone mineral density on routine bone density scanning, a review of causes and management. Rheumatology (Oxford). 2013;52(6):968\u2013985."},{"issue":"7","key":"b26","series-title":"Eur J Orthop Surg Traumatol","first-page":"1291","article-title":"Risk factors for cage subsidence and clinical outcomes after transforaminal and posterior lumbar interbody fusion","volume":"32","author":"Amorim-Barbosa T","year":"2022","unstructured":"Amorim-Barbosa T, Pereira C, Catelas D,  Risk factors for cage subsidence and clinical outcomes after transforaminal and posterior lumbar interbody fusion. Eur J Orthop Surg Traumatol. 2022;32(7):1291\u20131299."},{"issue":"1","key":"b27","series-title":"Eur Spine J","first-page":"216","article-title":"Cervical vertebral Hounsfield units are a better predictor of Zero-P subsidence than the T-score of DXA in patients following single-level anterior cervical discectomy and fusion with zero-profile anchored spacer","volume":"33","author":"Pu H","year":"2024","unstructured":"Pu H, Yu Song X, Zhou Wang B,  Cervical vertebral Hounsfield units are a better predictor of Zero-P subsidence than the T-score of DXA in patients following single-level anterior cervical discectomy and fusion with zero-profile anchored spacer. Eur Spine J. 2024;33(1):216\u2013223."},{"issue":"9","key":"b28","series-title":"Spine J","first-page":"S211","article-title":"P302. The superiority of endplate Hounsfield Units relative to lumbar vertebral Hounsfield Units in predicting subsidence after transforaminal lumbar interbody fusion","volume":"24","author":"Levy HA","year":"2024","unstructured":"Levy HA, Bydon M, Elder BD,  P302. The superiority of endplate Hounsfield Units relative to lumbar vertebral Hounsfield Units in predicting subsidence after transforaminal lumbar interbody fusion. Spine J. 2024;24(9):S211."},{"issue":"3","key":"b29","series-title":"Eur Spine J","first-page":"235","article-title":"Variation of endplate thickness in the cervical spine","volume":"13","author":"Pitzen T","year":"2004","unstructured":"Pitzen T, Schmitz B, Georg T,  Variation of endplate thickness in the cervical spine. Eur Spine J. 2004;13(3):235\u2013240."},{"key":"b30","series-title":"World Neurosurg","first-page":"e700","article-title":"Risk factors for allograft subsidence following anterior cervical discectomy and fusion","volume":"170","author":"Pinter ZW","year":"2023","unstructured":"Pinter ZW, Mikula A, Shirley M,  Risk factors for allograft subsidence following anterior cervical discectomy and fusion. World Neurosurg. 2023;170:e700\u2013e711."},{"issue":"1","key":"b31","series-title":"BMC Med Res Methodol","first-page":"93","article-title":"Estimation of an inter-rater intra-class correlation coefficient that overcomes common assumption violations in the assessment of health measurement scales","volume":"18","author":"Bobak CA","year":"2018","unstructured":"Bobak CA, Barr PJ, O\u2019Malley AJ. Estimation of an inter-rater intra-class correlation coefficient that overcomes common assumption violations in the assessment of health measurement scales. BMC Med Res Methodol. 2018;18(1):93."},{"key":"b32","article-title":"Statistics Without Maths for Psychology","author":"Dancey CP","year":"2007","unstructured":"Dancey CP, Reidy J. Statistics Without Maths for Psychology. Pearson Education; 2007."},{"issue":"5","key":"b33","series-title":"Global Spine J","first-page":"851","article-title":"Average lumbar Hounsfield units predicts osteoporosis-related complications following lumbar spine fusion","volume":"12","author":"St Jeor JD","year":"2022","unstructured":"St Jeor JD, Jackson TJ, Xiong AE,  Average lumbar Hounsfield units predicts osteoporosis-related complications following lumbar spine fusion. Global Spine J. 2022;12(5):851\u2013857."},{"issue":"5","key":"b34","series-title":"J Bone Miner Res","first-page":"860","article-title":"Future osteoporotic fracture risk related to lumbar vertebral trabecular attenuation measured at routine body CT","volume":"33","author":"Lee SJ","year":"2018","unstructured":"Lee SJ, Graffy PM, Zea RD, Ziemlewicz TJ, Pickhardt PJ. Future osteoporotic fracture risk related to lumbar vertebral trabecular attenuation measured at routine body CT. J Bone Miner Res. 2018;33(5):860\u2013867."},{"issue":"3","key":"b35","series-title":"Eur Radiol","first-page":"1526","article-title":"The preoperative Hounsfield unit value at the position of the future screw insertion is a better predictor of screw loosening than other methods","volume":"33","author":"Li J","year":"2023","unstructured":"Li J, Zhang Z, Xie T, Song Z, Song Y, Zeng J. The preoperative Hounsfield unit value at the position of the future screw insertion is a better predictor of screw loosening than other methods. Eur Radiol. 2023;33(3):1526\u20131536."},{"issue":"1","key":"b36","series-title":"BMC Musculoskelet Disord","first-page":"1","article-title":"Risk factors of instrumentation failure after laminectomy and posterior cervical fusions (PCF)","volume":"25","author":"Chen Z","year":"2024","unstructured":"Chen Z, Lv G, Zhang O,  Risk factors of instrumentation failure after laminectomy and posterior cervical fusions (PCF). BMC Musculoskelet Disord. 2024;25(1):1."},{"issue":"5","key":"b37","series-title":"J Orthop Sci","first-page":"734","article-title":"Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusion","volume":"23","author":"Sakai Y","year":"2018","unstructured":"Sakai Y, Takenaka S, Matsuo Y,  Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusion. J Orthop Sci. 2018;23(5):734\u2013738."},{"issue":"10","key":"b38","series-title":"Spine J","first-page":"1729","article-title":"Endplate volumetric bone mineral density is a predictor for cage subsidence following lateral lumbar interbody fusion: a risk factor analysis","volume":"21","author":"Jones C","year":"2021","unstructured":"Jones C, Okano I, Salzmann SN,  Endplate volumetric bone mineral density is a predictor for cage subsidence following lateral lumbar interbody fusion: a risk factor analysis. Spine J. 2021;21(10):1729\u20131737."},{"issue":"5","key":"b39","series-title":"Eur Spine J","first-page":"1131","article-title":"Endplate volumetric bone mineral density measured by quantitative computed tomography as a novel predictive measure of severe cage subsidence after standalone lateral lumbar fusion","volume":"29","author":"Okano I","year":"2020","unstructured":"Okano I, Jones C, Salzmann SN,  Endplate volumetric bone mineral density measured by quantitative computed tomography as a novel predictive measure of severe cage subsidence after standalone lateral lumbar fusion. Eur Spine J. 2020;29(5):1131\u20131140."},{"issue":"5","key":"b40","series-title":"J Clin Med","first-page":"1374","article-title":"Comparative study of cage subsidence in single-level lateral lumbar interbody fusion","volume":"11","author":"Hiyama A","year":"2022","unstructured":"Hiyama A, Sakai D, Katoh H, Nomura S, Sato M, Watanabe M. Comparative study of cage subsidence in single-level lateral lumbar interbody fusion. J Clin Med. 2022;11(5):1374."},{"issue":"1","key":"b41","series-title":"Sci Rep","first-page":"748","article-title":"Comparison of laminoplasty and posterior fusion surgery for cervical ossification of posterior longitudinal ligament","volume":"12","author":"Nakashima H","year":"2022","unstructured":"Nakashima H, Imagama S, Yoshii T,  Comparison of laminoplasty and posterior fusion surgery for cervical ossification of posterior longitudinal ligament. Sci Rep. 2022;12(1):748."},{"issue":"1","key":"b1","series-title":"Surg Neurol","first-page":"66","article-title":"National trends in spinal fusion for cervical spondylotic myelopathy","volume":"71","author":"Lad SP","year":"2009","unstructured":"Lad SP, Patil CG, Berta S, Santarelli JG, Ho C, Boakye M. National trends in spinal fusion for cervical spondylotic myelopathy. Surg Neurol. 2009;71(1):66\u201369."},{"issue":"2","key":"b2","series-title":"Brain","first-page":"325","article-title":"Epidemiology of cervical radiculopathy: a population-based study from Rochester, Minnesota, 1976 through 1990","volume":"117","author":"Radhakrishnan K","year":"1994","unstructured":"Radhakrishnan K, Litchy WJ, O\u2019Fallon WM, Kurland LT. Epidemiology of cervical radiculopathy: a population-based study from Rochester, Minnesota, 1976 through 1990. Brain. 1994;117(2):325\u2013335."},{"issue":"3","key":"b3","series-title":"Global Spine J","first-page":"689","article-title":"Does facet distraction affect patient outcomes after ACDF?","volume":"13","author":"Karamian BA","year":"2023","unstructured":"Karamian BA, Levy HA, Canseco JA,  Does facet distraction affect patient outcomes after ACDF? Global Spine J. 2023;13(3):689\u2013695."},{"issue":"7","key":"b4","series-title":"J Bone Jt Surg","first-page":"941","article-title":"Anterior cervical decompression and arthrodesis for the treatment of cervical spondylotic myelopathy. Two to seventeen-year follow-up","volume":"80","author":"Emery SE","year":"1998","unstructured":"Emery SE, Bohlman HH, Bolesta MJ, Jones PK. Anterior cervical decompression and arthrodesis for the treatment of cervical spondylotic myelopathy. Two to seventeen-year follow-up. J Bone Jt Surg. 1998;80(7):941\u2013951."},{"issue":"6","key":"b5","series-title":"Spine (Phila Pa 1976)","first-page":"E365","article-title":"Surgical treatment of cervical radiculopathy","volume":"43","author":"Gutman G","year":"2018","unstructured":"Gutman G, Rosenzweig DH, Golan JD. Surgical treatment of cervical radiculopathy. Spine (Phila Pa 1976). 2018;43(6):E365\u2013E372."},{"issue":"7","key":"b6","series-title":"Global Spine J","first-page":"1703","article-title":"Titanium cervical cage subsidence: postoperative computed tomography analysis defining incidence and associated risk factors","volume":"13","author":"Pinter ZW","year":"2023","unstructured":"Pinter ZW, Reed R, Townsley SE,  Titanium cervical cage subsidence: postoperative computed tomography analysis defining incidence and associated risk factors. Global Spine J. 2023;13(7):1703\u20131715."},{"issue":"12","key":"b7","series-title":"J Clin Neurosci","first-page":"1673","article-title":"Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion: cage subsidence and cervical alignment","volume":"19","author":"Yamagata T","year":"2012","unstructured":"Yamagata T, Takami T, Uda T,  Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion: cage subsidence and cervical alignment. J Clin Neurosci. 2012;19(12):1673\u20131678."},{"issue":"8","key":"b8","series-title":"Spine (Phila Pa 1976)","first-page":"951","article-title":"Effect of endplate conditions and bone mineral density on the compressive strength of the graft\u2013endplate interface in anterior cervical spine fusion","volume":"26","author":"Lim TH","year":"2001","unstructured":"Lim TH, Kwon H, Jeon CH,  Effect of endplate conditions and bone mineral density on the compressive strength of the graft\u2013endplate interface in anterior cervical spine fusion. Spine (Phila Pa 1976). 2001;26(8):951\u2013956."},{"issue":"3","key":"b9","series-title":"Neurosurgery","first-page":"502","article-title":"Subsidence of stand-alone cervical carbon fiber cages","volume":"58","author":"Bartels RHMA","year":"2006","unstructured":"Bartels RHMA, Donk RD, Feuth T. Subsidence of stand-alone cervical carbon fiber cages. Neurosurgery. 2006;58(3):502\u2013508."},{"issue":"1","key":"b10","series-title":"Clin Orthop Surg","first-page":"16","article-title":"Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage","volume":"3","author":"Yang JJ","year":"2011","unstructured":"Yang JJ, Yu CH, Chang BS, Yeom JS, Lee JH, Lee CK. Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage. Clin Orthop Surg. 2011;3(1):16\u201323."},{"issue":"9","key":"b11","series-title":"Eur Spine J","first-page":"1395","article-title":"Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion","volume":"16","author":"Barsa P","year":"2007","unstructured":"Barsa P, Suchomel P. Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion. Eur Spine J. 2007;16(9):1395\u20131400."},{"issue":"9","key":"b12","series-title":"Clin Spine Surg","first-page":"E1239","article-title":"Graft subsidence and revision rates following anterior cervical corpectomy","volume":"30","author":"Weber MH","year":"2017","unstructured":"Weber MH, Fortin M, Shen J,  Graft subsidence and revision rates following anterior cervical corpectomy. Clin Spine Surg. 2017;30(9):E1239\u2013E1245."},{"issue":"1","key":"b13","series-title":"J Neurosurg Spine","first-page":"50","article-title":"Graft subsidence as a predictor of revision surgery following stand-alone lateral lumbar interbody fusion","volume":"28","author":"Tempel ZJ","year":"2018","unstructured":"Tempel ZJ, McDowell MM, Panczykowski DM,  Graft subsidence as a predictor of revision surgery following stand-alone lateral lumbar interbody fusion. J Neurosurg Spine. 2018;28(1):50\u201356."},{"issue":"suppl 3","key":"b14","series-title":"Eur Spine J","first-page":"414","article-title":"Impaired bone mineral density as a predictor of graft subsidence following minimally invasive transpsoas lateral lumbar interbody fusion","volume":"24","author":"Tempel ZJ","year":"2015","unstructured":"Tempel ZJ, Gandhoke GS, Okonkwo DO, Kanter AS. Impaired bone mineral density as a predictor of graft subsidence following minimally invasive transpsoas lateral lumbar interbody fusion. Eur Spine J. 2015;24(suppl 3):414-419."},{"issue":"8","key":"b15","series-title":"Global Spine J","first-page":"1723","article-title":"Allograft subsidence decreases postoperative segmental lordosis with minimal effect on global alignment following ACDF","volume":"12","author":"Pinter ZW","year":"2022","unstructured":"Pinter ZW, Mikula A, Shirley M,  Allograft subsidence decreases postoperative segmental lordosis with minimal effect on global alignment following ACDF. Global Spine J. 2022;12(8):1723\u20131730."},{"issue":"5","key":"b16","series-title":"J Neurosurg Spine","first-page":"540","article-title":"Is disc height loss at 1 year predictive of pseudarthrosis and patient-reported outcome measures following anterior cervical discectomy and fusion with structural allograft?","volume":"38","author":"D\u2019Antonio ND","year":"2023","unstructured":"D\u2019Antonio ND, Lambrechts MJ, Heard JC,  Is disc height loss at 1 year predictive of pseudarthrosis and patient-reported outcome measures following anterior cervical discectomy and fusion with structural allograft? J Neurosurg Spine. 2023;38(5):540\u2013546."},{"issue":"5","key":"b17","series-title":"Eur Spine J","first-page":"513","article-title":"Subsidence of stand-alone cervical cages in anterior interbody fusion: warning","volume":"12","author":"Gercek E","year":"2003","unstructured":"Gercek E, Arlet V, Delisle J, Marchesi D. Subsidence of stand-alone cervical cages in anterior interbody fusion: warning. Eur Spine J. 2003;12(5):513\u2013516."},{"issue":"4","key":"b18","series-title":"J Neurosurg Spine","first-page":"463","article-title":"Transforaminal lumbar interbody fusion subsidence: computed tomography analysis of incidence, associated risk factors, and impact on outcomes","volume":"41","author":"Levy HA","year":"2024","unstructured":"Levy HA, Pinter ZW, Reed R,  Transforaminal lumbar interbody fusion subsidence: computed tomography analysis of incidence, associated risk factors, and impact on outcomes. J Neurosurg Spine. 2024;41(4):463\u2013472."},{"issue":"2","key":"b19","series-title":"J Spinal Disord Tech","first-page":"87","article-title":"Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion","volume":"26","author":"Kim MC","year":"2013","unstructured":"Kim MC, Chung HT, Cho JL, Kim DJ, Chung NS. Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion. J Spinal Disord Tech. 2013;26(2):87\u201392."},{"issue":"22","key":"b20","series-title":"Spine (Phila Pa 1976)","first-page":"2441","article-title":"Effects of disc height and distractive forces on graft compression in an anterior cervical discectomy model","volume":"27","author":"Truumees E","year":"2002","unstructured":"Truumees E, Demetropoulos CK, Yang KH, Herkowitz HN. Effects of disc height and distractive forces on graft compression in an anterior cervical discectomy model. Spine (Phila Pa 1976). 2002;27(22):2441\u20132445."},{"issue":"2","key":"b21","series-title":"Neurosurg Focus","first-page":"E9","article-title":"Lumbar disc height and vertebral Hounsfield units: association with interbody cage subsidence","volume":"49","author":"Pisano AJ","year":"2020","unstructured":"Pisano AJ, Fredericks DR, Steelman T, Riccio C, Helgeson MD, Wagner SC. Lumbar disc height and vertebral Hounsfield units: association with interbody cage subsidence. Neurosurg Focus. 2020;49(2):E9."},{"issue":"9","key":"b22","series-title":"Acta Neurochir (Wien)","first-page":"2557","article-title":"Risk factors for polyetheretherketone cage subsidence following minimally invasive transforaminal lumbar interbody fusion","volume":"163","author":"Singhatanadgige W","year":"2021","unstructured":"Singhatanadgige W, Sukthuayat A, Tanaviriyachai T,  Risk factors for polyetheretherketone cage subsidence following minimally invasive transforaminal lumbar interbody fusion. Acta Neurochir (Wien). 2021;163(9):2557\u20132565."},{"issue":"1","key":"b23","series-title":"BMC Musculoskelet Disord","first-page":"882","article-title":"The value of Hounsfield units in predicting cage subsidence after transforaminal lumbar interbody fusion","volume":"23","author":"Xie F","year":"2022","unstructured":"Xie F, Yang Z, Tu Z,  The value of Hounsfield units in predicting cage subsidence after transforaminal lumbar interbody fusion. BMC Musculoskelet Disord. 2022;23(1):882."},{"issue":"1","key":"b24","series-title":"Sci Rep","first-page":"1620","article-title":"CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion","volume":"13","author":"Yao YC","year":"2023","unstructured":"Yao YC, Chao H, Kao KY,  CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion. Sci Rep. 2023;13(1):1620."},{"issue":"6","key":"b25","series-title":"Rheumatology (Oxford)","first-page":"968","article-title":"Friend or foe: high bone mineral density on routine bone density scanning, a review of causes and management","volume":"52","author":"Gregson CL","year":"2013","unstructured":"Gregson CL, Hardcastle SA, Cooper C, Tobias JH. Friend or foe: high bone mineral density on routine bone density scanning, a review of causes and management. Rheumatology (Oxford). 2013;52(6):968\u2013985."},{"issue":"7","key":"b26","series-title":"Eur J Orthop Surg Traumatol","first-page":"1291","article-title":"Risk factors for cage subsidence and clinical outcomes after transforaminal and posterior lumbar interbody fusion","volume":"32","author":"Amorim-Barbosa T","year":"2022","unstructured":"Amorim-Barbosa T, Pereira C, Catelas D,  Risk factors for cage subsidence and clinical outcomes after transforaminal and posterior lumbar interbody fusion. Eur J Orthop Surg Traumatol. 2022;32(7):1291\u20131299."},{"issue":"1","key":"b27","series-title":"Eur Spine J","first-page":"216","article-title":"Cervical vertebral Hounsfield units are a better predictor of Zero-P subsidence than the T-score of DXA in patients following single-level anterior cervical discectomy and fusion with zero-profile anchored spacer","volume":"33","author":"Pu H","year":"2024","unstructured":"Pu H, Yu Song X, Zhou Wang B,  Cervical vertebral Hounsfield units are a better predictor of Zero-P subsidence than the T-score of DXA in patients following single-level anterior cervical discectomy and fusion with zero-profile anchored spacer. Eur Spine J. 2024;33(1):216\u2013223."},{"issue":"9","key":"b28","series-title":"Spine J","first-page":"S211","article-title":"P302. The superiority of endplate Hounsfield Units relative to lumbar vertebral Hounsfield Units in predicting subsidence after transforaminal lumbar interbody fusion","volume":"24","author":"Levy HA","year":"2024","unstructured":"Levy HA, Bydon M, Elder BD,  P302. The superiority of endplate Hounsfield Units relative to lumbar vertebral Hounsfield Units in predicting subsidence after transforaminal lumbar interbody fusion. Spine J. 2024;24(9):S211."},{"issue":"3","key":"b29","series-title":"Eur Spine J","first-page":"235","article-title":"Variation of endplate thickness in the cervical spine","volume":"13","author":"Pitzen T","year":"2004","unstructured":"Pitzen T, Schmitz B, Georg T,  Variation of endplate thickness in the cervical spine. Eur Spine J. 2004;13(3):235\u2013240."},{"key":"b30","series-title":"World Neurosurg","first-page":"e700","article-title":"Risk factors for allograft subsidence following anterior cervical discectomy and fusion","volume":"170","author":"Pinter ZW","year":"2023","unstructured":"Pinter ZW, Mikula A, Shirley M,  Risk factors for allograft subsidence following anterior cervical discectomy and fusion. World Neurosurg. 2023;170:e700\u2013e711."},{"issue":"1","key":"b31","series-title":"BMC Med Res Methodol","first-page":"93","article-title":"Estimation of an inter-rater intra-class correlation coefficient that overcomes common assumption violations in the assessment of health measurement scales","volume":"18","author":"Bobak CA","year":"2018","unstructured":"Bobak CA, Barr PJ, O\u2019Malley AJ. Estimation of an inter-rater intra-class correlation coefficient that overcomes common assumption violations in the assessment of health measurement scales. BMC Med Res Methodol. 2018;18(1):93."},{"key":"b32","article-title":"Statistics Without Maths for Psychology","author":"Dancey CP","year":"2007","unstructured":"Dancey CP, Reidy J. Statistics Without Maths for Psychology. Pearson Education; 2007."},{"issue":"5","key":"b33","series-title":"Global Spine J","first-page":"851","article-title":"Average lumbar Hounsfield units predicts osteoporosis-related complications following lumbar spine fusion","volume":"12","author":"St Jeor JD","year":"2022","unstructured":"St Jeor JD, Jackson TJ, Xiong AE,  Average lumbar Hounsfield units predicts osteoporosis-related complications following lumbar spine fusion. Global Spine J. 2022;12(5):851\u2013857."},{"issue":"5","key":"b34","series-title":"J Bone Miner Res","first-page":"860","article-title":"Future osteoporotic fracture risk related to lumbar vertebral trabecular attenuation measured at routine body CT","volume":"33","author":"Lee SJ","year":"2018","unstructured":"Lee SJ, Graffy PM, Zea RD, Ziemlewicz TJ, Pickhardt PJ. Future osteoporotic fracture risk related to lumbar vertebral trabecular attenuation measured at routine body CT. J Bone Miner Res. 2018;33(5):860\u2013867."},{"issue":"3","key":"b35","series-title":"Eur Radiol","first-page":"1526","article-title":"The preoperative Hounsfield unit value at the position of the future screw insertion is a better predictor of screw loosening than other methods","volume":"33","author":"Li J","year":"2023","unstructured":"Li J, Zhang Z, Xie T, Song Z, Song Y, Zeng J. The preoperative Hounsfield unit value at the position of the future screw insertion is a better predictor of screw loosening than other methods. Eur Radiol. 2023;33(3):1526\u20131536."},{"issue":"1","key":"b36","series-title":"BMC Musculoskelet Disord","first-page":"1","article-title":"Risk factors of instrumentation failure after laminectomy and posterior cervical fusions (PCF)","volume":"25","author":"Chen Z","year":"2024","unstructured":"Chen Z, Lv G, Zhang O,  Risk factors of instrumentation failure after laminectomy and posterior cervical fusions (PCF). BMC Musculoskelet Disord. 2024;25(1):1."},{"issue":"5","key":"b37","series-title":"J Orthop Sci","first-page":"734","article-title":"Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusion","volume":"23","author":"Sakai Y","year":"2018","unstructured":"Sakai Y, Takenaka S, Matsuo Y,  Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusion. J Orthop Sci. 2018;23(5):734\u2013738."},{"issue":"10","key":"b38","series-title":"Spine J","first-page":"1729","article-title":"Endplate volumetric bone mineral density is a predictor for cage subsidence following lateral lumbar interbody fusion: a risk factor analysis","volume":"21","author":"Jones C","year":"2021","unstructured":"Jones C, Okano I, Salzmann SN,  Endplate volumetric bone mineral density is a predictor for cage subsidence following lateral lumbar interbody fusion: a risk factor analysis. Spine J. 2021;21(10):1729\u20131737."},{"issue":"5","key":"b39","series-title":"Eur Spine J","first-page":"1131","article-title":"Endplate volumetric bone mineral density measured by quantitative computed tomography as a novel predictive measure of severe cage subsidence after standalone lateral lumbar fusion","volume":"29","author":"Okano I","year":"2020","unstructured":"Okano I, Jones C, Salzmann SN,  Endplate volumetric bone mineral density measured by quantitative computed tomography as a novel predictive measure of severe cage subsidence after standalone lateral lumbar fusion. Eur Spine J. 2020;29(5):1131\u20131140."},{"issue":"5","key":"b40","series-title":"J Clin Med","first-page":"1374","article-title":"Comparative study of cage subsidence in single-level lateral lumbar interbody fusion","volume":"11","author":"Hiyama A","year":"2022","unstructured":"Hiyama A, Sakai D, Katoh H, Nomura S, Sato M, Watanabe M. Comparative study of cage subsidence in single-level lateral lumbar interbody fusion. J Clin Med. 2022;11(5):1374."},{"issue":"1","key":"b41","series-title":"Sci Rep","first-page":"748","article-title":"Comparison of laminoplasty and posterior fusion surgery for cervical ossification of posterior longitudinal ligament","volume":"12","author":"Nakashima H","year":"2022","unstructured":"Nakashima H, Imagama S, Yoshii T,  Comparison of laminoplasty and posterior fusion surgery for cervical ossification of posterior longitudinal ligament. Sci Rep. 2022;12(1):748."}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/43\/6\/article-p672.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/43\/6\/article-p672.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/43\/6\/article-p672.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T13:45:23Z","timestamp":1772804723000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/43\/6\/article-p672.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,8]]},"references-count":82,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2025.4.spine241067","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2025,8,8]]}}}