{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T06:23:32Z","timestamp":1790663012315,"version":"4.1.0"},"reference-count":60,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["FOC"],"published-print":{"date-parts":[[2008,9]]},"abstract":"<jats:sec>\n                    <jats:title>Object<\/jats:title>\n                    <jats:p>The authors summarize one center's experience with a novel device, the Responsive Neurostimulation (RNS) system, which is used to treat seizures, and they provide technical details regarding the implantation procedure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The authors reviewed seizure detection, cortical stimulation, and clinical data obtained in 7 patients in whom the RNS system was implanted. Data pertaining to seizure alteration are provided for the first 4 implant-treated patients. The implantation procedure in the case of one patient with occipital lobe heterotopia is included.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Based on patients' seizure diaries, the implanted devices functioned at a high sensitivity for clinical seizure detection. Reductions in seizure frequency, based on their diaries and on clinic follow-up notes, ranged from 50 to 75%. No adverse stimulation-induced side effects were noted, and no hardware malfunctions requiring explantation occurred. Generator replacements for battery depletion were required at 11, 17, and 20 months in 3 patients. The implantation procedure was well tolerated, and postoperative hospital stays were short. A revision cranioplasty for a skull defect was performed in the index patient, whose case will be discussed in the most detail.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The results obtained in this small preliminary series demonstrate a safe implantation method for the responsive neurostimulation device.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3171\/foc\/2008\/25\/9\/e12","type":"journal-article","created":{"date-parts":[[2008,8,29]],"date-time":"2008-08-29T20:52:07Z","timestamp":1220043127000},"page":"E12","source":"Crossref","is-referenced-by-count":51,"title":["Implantation of a responsive neurostimulator device in patients with refractory epilepsy"],"prefix":"10.3171","volume":"25","author":[{"given":"William S.","family":"Anderson","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Harvard Medical School, Brigham and Women's Hospital, Boston, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric H.","family":"Kossoff","sequence":"additional","affiliation":[{"name":"Departments of Neurology and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory K.","family":"Bergey","sequence":"additional","affiliation":[{"name":"Departments of Neurology and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George I.","family":"Jallo","sequence":"additional","affiliation":[{"name":"Neurosurgery, The Johns Hopkins Hospital, Baltimore, Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"issue":"4 Suppl","key":"b1-0250012","series-title":"Epilepsia","first-page":"A12","article-title":"Safety and preliminary efficacy of the RNS responsive neurostimulator for the treatment of intractable epilepsy in adults","volume":"47","author":"Barkley","year":"2006"},{"key":"b2-0250012","series-title":"Neurosurgery","first-page":"1385","article-title":"Antiepileptic effect of high-frequency stimulation of the subthalamic nucleus (corpus luysi) in a case of medically intractable epilepsy caused by focal dysplasia: a 30-month follow-up: technical case report","volume":"50","author":"Benabid","year":"2002"},{"key":"b3-0250012","series-title":"J Neurosurg","first-page":"203","article-title":"Chronic electrical stimulation of the ventralis intermedius nucleus of the thalamus as a treatment of movement disorders","volume":"84","author":"Benabid","year":"1996"},{"key":"b4-0250012","series-title":"Stereotact Funct Neurosurg","first-page":"76","article-title":"Acute and long-term effects of subthalamic nucleus stimulation in Parkinson's disease","volume":"62","author":"Benabid","year":"1994"},{"key":"b5-0250012","series-title":"Epilepsia","first-page":"616","article-title":"Vagus nerve stimulation for treatment of partial seizures: 1. A controlled study of effect on seizures. First International Vagus Nerve Stimulation Study Group","volume":"35","author":"Ben-Menachem","year":"1994"},{"key":"b6-0250012","series-title":"Clin Neurol Neurosurg","first-page":"318","article-title":"Electrophysiological effects and clinical results of direct brain stimulation for intractable epilepsy","volume":"106","author":"Chkhenkeli","year":"2004"},{"key":"b7-0250012","series-title":"IEEE Trans Biomed Eng","first-page":"603","article-title":"Epileptic seizure prediction using hybrid feature selection over multiple intracranial EEG electrode contacts: a report of four patients","volume":"50","author":"D'Alessandro","year":"2003"},{"issue":"7 Suppl","key":"b8-0250012","series-title":"Epilepsia","first-page":"35","article-title":"Long-term validation of detection algorithms suitable for an implantable device","volume":"42","author":"Echauz","year":"2001"},{"key":"b9-0250012","series-title":"Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, October 2001, Istanbul, Turkey","first-page":"1707","article-title":"Line length: an efficient feature of seizure onset detection","author":"Estellar"},{"key":"b10-0250012","series-title":"Epilepsia","first-page":"841","article-title":"Placebo-controlled pilot study of centromedian thalamic stimulation in treatment of intractable seizures","volume":"33","author":"Fisher","year":"1992"},{"key":"b11-0250012","series-title":"Stereotact Funct Neurosurg","first-page":"153","article-title":"Implantation of a closed-loop stimulation in the management of medically refractory focal epilepsy: a technical note","volume":"83","author":"Fountas","year":"2005"},{"key":"b12-0250012","series-title":"Epilepsy Res","first-page":"65","article-title":"External excitatory stimuli can terminate bursting in neural network models","volume":"53","author":"Franaszczuk","year":"2003"},{"key":"b13-0250012","series-title":"Acta Neurochir Suppl (Wien)","first-page":"127","article-title":"Taylored implants for alloplastic cranioplasty\u2014clinical and surgical considerations","volume":"93","author":"Hoffmann","year":"2005"},{"key":"b14-0250012","series-title":"Epilepsia","first-page":"346","article-title":"Electrical stimulation of the anterior nucleus of the thalamus for the treatment of intractable epilepsy","volume":"45","author":"Kerrigan","year":"2004"},{"key":"b15-0250012","series-title":"Epilepsia","first-page":"787","article-title":"Electrical stimulation on human cortex suppresses fast cortical activity and epileptic spikes","volume":"45","author":"Kinoshita","year":"2004"},{"key":"b16-0250012","series-title":"Epilepsia","first-page":"1560","article-title":"Effect of an external responsive neurostimulator on seizures and electrographic discharges during subdural electrode monitoring","volume":"45","author":"Kossoff","year":"2004"},{"key":"b17-0250012","series-title":"Clin Neurophysiol","first-page":"2431","article-title":"Selection of stimulus parameters for deep brain stimulation","volume":"115","author":"Kuncel","year":"2004"},{"key":"b18-0250012","series-title":"Neurology","first-page":"2073","article-title":"Brief bursts of pulse stimulation terminate after discharges caused by cortical stimulation","volume":"53","author":"Lesser","year":"1999"},{"key":"b19-0250012","series-title":"Lancet Neurol","first-page":"22","article-title":"Prediction of epileptic seizures","volume":"1","author":"Litt","year":"2002"},{"key":"b20-0250012","article-title":"Responsive Neurostimulator (RNS) System Feasibility Clinical Investigation","author":"NeuroPace","year":"2004"},{"key":"b21-0250012","series-title":"IEEE Trans Biomed Eng","first-page":"449","article-title":"Detection of seizure precursors from depth-EEG using a sign periodogram transform","volume":"51","author":"Niederhauser","year":"2003"},{"key":"b22-0250012","series-title":"J Clin Neurophys","first-page":"533","article-title":"An introduction to contingent (closed-loop) brain electrical stimulation for seizure blockage, ultra-short-term clinical trials, and to multidimensional statistical analysis of therapeutic efficacy","volume":"18","author":"Osorio","year":"2001"},{"key":"b23-0250012","series-title":"Epilepsy and the Functional Anatomy of the Human Brain","first-page":"712","author":"Penfield","year":"1954"},{"issue":"2 Suppl","key":"b24-0250012","series-title":"Epilepsia","first-page":"S40","article-title":"Prevention of intractable partial seizures by intermittent vagal stimulation in humans: preliminary results","volume":"31","author":"Penry","year":"1990"},{"key":"b25-0250012","series-title":"Acta Neurochir (Wien)","first-page":"1193","article-title":"Cranioplasty with individual carbon fiber reinforced polymere (CFRP) medical grade implants based on CAD\/CAM technique","volume":"144","author":"Saringer","year":"2002"},{"key":"b26-0250012","series-title":"Neurosurgery","first-page":"1126","article-title":"Bilateral chronic electrostimulation of the ventroposterolateral pallidum: a new therapeutic approach for alleviating all Parkinsonian symptoms","volume":"35","author":"Siegfried","year":"1994"},{"key":"b27-0250012","series-title":"Biomaterials","first-page":"324","article-title":"Polyetheretherketone as a biomaterial for spinal applications","volume":"27","author":"Toth","year":"2006"},{"issue":"2 Suppl","key":"b28-0250012","series-title":"Epilepsia","first-page":"S44","article-title":"Efficacy and safety of vagus nerve stimulation in patients with complex partial seizures","volume":"31","author":"Uthman","year":"1990"},{"key":"b29-0250012","series-title":"Epilepsia","first-page":"1071","article-title":"Double-blind, randomized controlled pilot study of bilateral cerebellar stimulation for treatment of intractable motor seizures","volume":"46","author":"Velasco","year":"2005"},{"key":"b30-0250012","series-title":"Stereotact Funct Neurosurg","first-page":"223","article-title":"Electrical stimulation for epilepsy: stimulation of hippocampal foci","volume":"77","author":"Velasco","year":"2001"},{"issue":"4 Suppl","key":"b1-0250012","series-title":"Epilepsia","first-page":"A12","article-title":"Safety and preliminary efficacy of the RNS responsive neurostimulator for the treatment of intractable epilepsy in adults","volume":"47","author":"Barkley","year":"2006"},{"key":"b2-0250012","series-title":"Neurosurgery","first-page":"1385","article-title":"Antiepileptic effect of high-frequency stimulation of the subthalamic nucleus (corpus luysi) in a case of medically intractable epilepsy caused by focal dysplasia: a 30-month follow-up: technical case report","volume":"50","author":"Benabid","year":"2002"},{"key":"b3-0250012","series-title":"J Neurosurg","first-page":"203","article-title":"Chronic electrical stimulation of the ventralis intermedius nucleus of the thalamus as a treatment of movement disorders","volume":"84","author":"Benabid","year":"1996"},{"key":"b4-0250012","series-title":"Stereotact Funct Neurosurg","first-page":"76","article-title":"Acute and long-term effects of subthalamic nucleus stimulation in Parkinson's disease","volume":"62","author":"Benabid","year":"1994"},{"key":"b5-0250012","series-title":"Epilepsia","first-page":"616","article-title":"Vagus nerve stimulation for treatment of partial seizures: 1. A controlled study of effect on seizures. First International Vagus Nerve Stimulation Study Group","volume":"35","author":"Ben-Menachem","year":"1994"},{"key":"b6-0250012","series-title":"Clin Neurol Neurosurg","first-page":"318","article-title":"Electrophysiological effects and clinical results of direct brain stimulation for intractable epilepsy","volume":"106","author":"Chkhenkeli","year":"2004"},{"key":"b7-0250012","series-title":"IEEE Trans Biomed Eng","first-page":"603","article-title":"Epileptic seizure prediction using hybrid feature selection over multiple intracranial EEG electrode contacts: a report of four patients","volume":"50","author":"D'Alessandro","year":"2003"},{"issue":"7 Suppl","key":"b8-0250012","series-title":"Epilepsia","first-page":"35","article-title":"Long-term validation of detection algorithms suitable for an implantable device","volume":"42","author":"Echauz","year":"2001"},{"key":"b9-0250012","series-title":"Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, October 2001, Istanbul, Turkey","first-page":"1707","article-title":"Line length: an efficient feature of seizure onset detection","author":"Estellar"},{"key":"b10-0250012","series-title":"Epilepsia","first-page":"841","article-title":"Placebo-controlled pilot study of centromedian thalamic stimulation in treatment of intractable seizures","volume":"33","author":"Fisher","year":"1992"},{"key":"b11-0250012","series-title":"Stereotact Funct Neurosurg","first-page":"153","article-title":"Implantation of a closed-loop stimulation in the management of medically refractory focal epilepsy: a technical note","volume":"83","author":"Fountas","year":"2005"},{"key":"b12-0250012","series-title":"Epilepsy Res","first-page":"65","article-title":"External excitatory stimuli can terminate bursting in neural network models","volume":"53","author":"Franaszczuk","year":"2003"},{"key":"b13-0250012","series-title":"Acta Neurochir Suppl (Wien)","first-page":"127","article-title":"Taylored implants for alloplastic cranioplasty\u2014clinical and surgical considerations","volume":"93","author":"Hoffmann","year":"2005"},{"key":"b14-0250012","series-title":"Epilepsia","first-page":"346","article-title":"Electrical stimulation of the anterior nucleus of the thalamus for the treatment of intractable epilepsy","volume":"45","author":"Kerrigan","year":"2004"},{"key":"b15-0250012","series-title":"Epilepsia","first-page":"787","article-title":"Electrical stimulation on human cortex suppresses fast cortical activity and epileptic spikes","volume":"45","author":"Kinoshita","year":"2004"},{"key":"b16-0250012","series-title":"Epilepsia","first-page":"1560","article-title":"Effect of an external responsive neurostimulator on seizures and electrographic discharges during subdural electrode monitoring","volume":"45","author":"Kossoff","year":"2004"},{"key":"b17-0250012","series-title":"Clin Neurophysiol","first-page":"2431","article-title":"Selection of stimulus parameters for deep brain stimulation","volume":"115","author":"Kuncel","year":"2004"},{"key":"b18-0250012","series-title":"Neurology","first-page":"2073","article-title":"Brief bursts of pulse stimulation terminate after discharges caused by cortical stimulation","volume":"53","author":"Lesser","year":"1999"},{"key":"b19-0250012","series-title":"Lancet Neurol","first-page":"22","article-title":"Prediction of epileptic seizures","volume":"1","author":"Litt","year":"2002"},{"key":"b20-0250012","article-title":"Responsive Neurostimulator (RNS) System Feasibility Clinical Investigation","author":"NeuroPace","year":"2004"},{"key":"b21-0250012","series-title":"IEEE Trans Biomed Eng","first-page":"449","article-title":"Detection of seizure precursors from depth-EEG using a sign periodogram transform","volume":"51","author":"Niederhauser","year":"2003"},{"key":"b22-0250012","series-title":"J Clin Neurophys","first-page":"533","article-title":"An introduction to contingent (closed-loop) brain electrical stimulation for seizure blockage, ultra-short-term clinical trials, and to multidimensional statistical analysis of therapeutic efficacy","volume":"18","author":"Osorio","year":"2001"},{"key":"b23-0250012","series-title":"Epilepsy and the Functional Anatomy of the Human Brain","first-page":"712","author":"Penfield","year":"1954"},{"issue":"2 Suppl","key":"b24-0250012","series-title":"Epilepsia","first-page":"S40","article-title":"Prevention of intractable partial seizures by intermittent vagal stimulation in humans: preliminary results","volume":"31","author":"Penry","year":"1990"},{"key":"b25-0250012","series-title":"Acta Neurochir (Wien)","first-page":"1193","article-title":"Cranioplasty with individual carbon fiber reinforced polymere (CFRP) medical grade implants based on CAD\/CAM technique","volume":"144","author":"Saringer","year":"2002"},{"key":"b26-0250012","series-title":"Neurosurgery","first-page":"1126","article-title":"Bilateral chronic electrostimulation of the ventroposterolateral pallidum: a new therapeutic approach for alleviating all Parkinsonian symptoms","volume":"35","author":"Siegfried","year":"1994"},{"key":"b27-0250012","series-title":"Biomaterials","first-page":"324","article-title":"Polyetheretherketone as a biomaterial for spinal applications","volume":"27","author":"Toth","year":"2006"},{"issue":"2 Suppl","key":"b28-0250012","series-title":"Epilepsia","first-page":"S44","article-title":"Efficacy and safety of vagus nerve stimulation in patients with complex partial seizures","volume":"31","author":"Uthman","year":"1990"},{"key":"b29-0250012","series-title":"Epilepsia","first-page":"1071","article-title":"Double-blind, randomized controlled pilot study of bilateral cerebellar stimulation for treatment of intractable motor seizures","volume":"46","author":"Velasco","year":"2005"},{"key":"b30-0250012","series-title":"Stereotact Funct Neurosurg","first-page":"223","article-title":"Electrical stimulation for epilepsy: stimulation of hippocampal foci","volume":"77","author":"Velasco","year":"2001"}],"container-title":["Neurosurgical Focus"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/25\/3\/article-pE12.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/25\/3\/article-pE12.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/neurosurg-focus\/25\/3\/article-pE12.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T08:52:58Z","timestamp":1779526378000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/neurosurg-focus\/25\/3\/article-pE12.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,9]]},"references-count":60,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3171\/foc\/2008\/25\/9\/e12","relation":{},"ISSN":["1092-0684"],"issn-type":[{"value":"1092-0684","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,9]]}}}