{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T01:55:25Z","timestamp":1774922125913,"version":"3.50.1"},"reference-count":25,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2008,6]]},"abstract":"<jats:sec>\n<jats:title>Object<\/jats:title>\n<jats:p>There is little evidence addressing whether procedures requiring adjunctive devices lead to an increased frequency of thromboembolic complications. The authors report their experience with 155 aneurysms treated with and without adjunctive devices.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>The authors retrospectively reviewed their last 155 aneurysm coil placement procedures. The patients' records were reviewed for the following phenomena: 1) evidence of procedure-related thrombus formation; 2) clinical evidence of stroke; and 3) the presence of acute ischemia in the treated vascular territory on diffusion-weighted (DW) imaging.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>Of the 155 aneurysms treated in 132 patients, 66 were treated with coils only, 45 had stent-assisted coil placement, 33 underwent balloon remodeling, and in 11 stents were placed after balloon remodeling. Small DW imaging abnormalities were present in the treated vascular territory in 24% of cases (37 lesions). Specifically, 21 (32%) of 66 lesions in the coil-treated group, 6 (13%) of 45 in the stent-assisted coil treatment group, 8 (24%) of 33 in the balloon remodeling group, and 2 (18%) of 11 in the balloon and stent group showed DW imaging positivity. Furthermore, 25 (68%) of the 37 cases that were positive on DW imaging occurred in patients presenting with subarachnoid hemorrhage (SAH). Clinically evident stroke or transient ischemic attack was present in 10 (27%) of 37 cases, with 70% occurring in patients presenting with SAH.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Use of adjunctive devices in treating aneurysms does not appear to increase the frequency of embolic or ischemic events. The presence of DW imaging abnormalities and clinically evident stroke was actually less frequent when adjunctive devices were used and in electively treated cases. This was probably related to perioperative antiplatelet medical management.<\/jats:p><\/jats:sec>","DOI":"10.3171\/jns\/2008\/108\/6\/1095","type":"journal-article","created":{"date-parts":[[2008,6,2]],"date-time":"2008-06-02T16:01:25Z","timestamp":1212422485000},"page":"1095-1100","source":"Crossref","is-referenced-by-count":82,"title":["Frequency of thromboembolic events associated with endovascular aneurysm treatment: retrospective case series"],"prefix":"10.3171","volume":"108","author":[{"given":"Nathaniel P.","family":"Brooks","sequence":"first","affiliation":[{"name":"Departments of Neurological Surgery and Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aquilla S.","family":"Turk","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David B.","family":"Niemann","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Beverly","family":"Aagaard-Kienitz","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kari","family":"Pulfer","sequence":"additional","affiliation":[{"name":"Departments of Neurological Surgery and Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Cook","sequence":"additional","affiliation":[{"name":"Biostatistics and Medical Informatics, University of Wisconsin at Madison, Wisconsin"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"1768","article-title":"Thromboembolic events associated with balloon-assisted coil embolization: evaluation with diffusion-weighted MR imaging","volume":"25","author":"Albayram","year":"2004"},{"key":"b2-1081095","series-title":"Circulation","doi-asserted-by":"publisher","first-page":"2210","DOI":"10.1161\/01.CIR.0000144301.82391.85","article-title":"Heparin and air filters reduce embolic events caused by intra-arterial cerebral angiography: a prospective, randomized trial","volume":"110","author":"Bendszus","year":"2004"},{"key":"b3-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"345","article-title":"Utility of balloon-assisted Guglielmi detachable coiling in the treatment of 49 cerebral aneurysms: a retrospective, multicenter study","volume":"22","author":"Cottier","year":"2001"},{"key":"b4-1081095","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"1329","DOI":"10.1161\/01.STR.31.6.1329","article-title":"Comparison of microembolism detected by transcranial Doppler and neuropsychological sequelae of carotid surgery and percutaneous transluminal angioplasty","volume":"31","author":"Crawley","year":"2000"},{"key":"b5-1081095","series-title":"Neuroradiology","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1007\/s00234-005-1408-2","article-title":"Diffusion and perfusion MRI in patients with ruptured and unruptured intracranial aneurysms treated by endovascular coiling: complications, procedural results, MR findings and clinical outcome","volume":"47","author":"Cronqvist","year":"2005"},{"key":"b6-1081095","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"837","DOI":"10.3171\/jns.2002.96.5.0837","article-title":"Postprocedure ischemic events after treatment of intracranial aneurysms with Guglielmi detachable coils","volume":"96","author":"Derdeyn","year":"2002"},{"key":"b7-1081095","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1227\/00006123-199508000-00006","article-title":"Hemostasis in spontaneous subarachnoidal hemorrhage","volume":"37","author":"Fujii","year":"1995"},{"key":"b8-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"1223","article-title":"Embolization of experimentally created aneurysms with intravascular stent devices","volume":"15","author":"Geremia","year":"1994"},{"key":"b9-1081095","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/jns.1991.75.1.0001","article-title":"Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technique, and experimental results","volume":"75","author":"Guglielmi","year":"1991"},{"key":"b10-1081095","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1097\/00006123-200204000-00010","article-title":"Diffusion-weighted magnetic resonance imaging in patients with subarachnoid hemorrhage","volume":"50","author":"Hadeishi","year":"2002"},{"key":"b11-1081095","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1227\/01.NEU.0000137653.93173.1C","article-title":"Treatment of unruptured cerebral aneurysms by embolization with guglielmi detachable coils: case-fatality, morbidity, and effectiveness in preventing bleeding\u2014a systematic review of the literature","volume":"55","author":"Lanterna","year":"2004"},{"key":"b12-1081095","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1097\/00006123-199909000-00024","article-title":"Balloon-assisted Guglielmi detachable coiling of wide-necked aneurysms: Part II\u2014clinical results","volume":"45","author":"Lefkowitz","year":"1999"},{"key":"b13-1081095","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1397","DOI":"10.1097\/00006123-200006000-00022","article-title":"Balloon-assist technique for endovascular coil embolization of geometrically difficult intracranial aneurysms","volume":"46","author":"Malek","year":"2000"},{"key":"b14-1081095","series-title":"Lancet","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1016\/S0140-6736(02)11314-6","article-title":"International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial","volume":"360","author":"Molyneux","year":"2002"},{"key":"b15-1081095","series-title":"J Neuroradiol","first-page":"30","article-title":"[Reconstruction technic in the treatment of wide-neck intracranial aneurysms: Long-term angiographic and clinical results. Apropos of 56 cases.]","volume":"24","author":"Moret","year":"1997"},{"key":"b16-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"19","article-title":"Balloon-assisted coil embolization of wide-necked aneurysms of the internal carotid artery: medium-term angiographic and clinical follow-up in 22 patients","volume":"22","author":"Nelson","year":"2001"},{"key":"b17-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"1541","article-title":"Thromboembolic events associated with the treatment of cerebral aneurysms with Guglielmi detachable coils","volume":"19","author":"Pelz","year":"1998"},{"key":"b18-1081095","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1360","DOI":"10.1097\/00006123-200006000-00014","article-title":"Prevention and treatment of thromboembolic and ischemic complications associated with endovascular procedures: Part II\u2014Clinical aspects and recommendations","volume":"46","author":"Qureshi","year":"2000"},{"key":"b19-1081095","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1097\/00006123-200002000-00006","article-title":"Ischemic events associated with unruptured intracranial aneurysms: multicenter clinical study and review of the literature","volume":"46","author":"Qureshi","year":"2000"},{"key":"b20-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"5","article-title":"Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils: prospective study applying diffusion-weighted imaging","volume":"22","author":"Rordorf","year":"2001"},{"key":"b21-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"2035","article-title":"Thromboembolic events associated with Guglielmi detachable coil embolization with use of diffusion-weighted MR imaging. Part II. Detection of the microemboli proximal to cerebral aneurysm","volume":"24","author":"Soeda","year":"2003"},{"key":"b22-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"127","article-title":"Thromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms: evaluation of 66 consecutive cases with use of diffusion-weighted MR imaging","volume":"24","author":"Soeda","year":"2003"},{"key":"b23-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"385","article-title":"Diffusion-weighted imaging abnormalities after percutaneous transluminal angioplasty and stenting for intracranial atherosclerotic disease","volume":"26","author":"Tsumoto","year":"2005"},{"key":"b24-1081095","series-title":"AJNR Am J Neuroradiol","first-page":"1498","article-title":"Procedural complications of coiling of ruptured intracranial aneurysms: incidence and risk factors in a consecutive series of 681 patients","volume":"27","author":"van Rooij","year":"2006"},{"key":"b25-1081095","series-title":"Lancet","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/S0140-6736(03)13860-3","article-title":"Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment","volume":"362","author":"Wiebers","year":"2003"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/108\/6\/article-p1095.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/108\/6\/article-p1095.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/108\/6\/article-p1095.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,9]],"date-time":"2024-03-09T09:40:47Z","timestamp":1709977247000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/108\/6\/article-p1095.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,6]]},"references-count":25,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/jns\/2008\/108\/6\/1095","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,6]]}}}