{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T17:15:33Z","timestamp":1762017333210},"reference-count":10,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JNS"],"published-print":{"date-parts":[[2008,6]]},"abstract":"<jats:p>\u2713 To the authors' knowledge, only 1 case of communicating hydrocephalus after endovascular coiling of unruptured brain aneurysms has been reported previously. Here, they report on 2 such cases of delayed communicating hydrocephalus after treatment with hydrogel-coated coils and offer the first histopathological evidence of foreign material, presumably related to the coils, as the cause of hydrocephalus.<\/jats:p>","DOI":"10.3171\/jns\/2008\/108\/6\/1241","type":"journal-article","created":{"date-parts":[[2008,6,2]],"date-time":"2008-06-02T16:01:25Z","timestamp":1212422485000},"page":"1241-1244","source":"Crossref","is-referenced-by-count":15,"title":["Communicating hydrocephalus after endovascular coiling of unruptured aneurysms"],"prefix":"10.3171","volume":"108","author":[{"given":"Alim P.","family":"Mitha","sequence":"first","affiliation":[{"name":"Divisions of Neurosurgery,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John H.","family":"Wong","sequence":"additional","affiliation":[{"name":"Divisions of Neurosurgery,"},{"name":"Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian-Qiang","family":"Lu","sequence":"additional","affiliation":[{"name":"Neuropathology, Foothills Medical Centre, University of Calgary, Alberta, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William F.","family":"Morrish","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark E.","family":"Hudon","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William Y.","family":"Hu","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology, and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1-1081241","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1227\/01.neu.0000310192.67937.d8","article-title":"HydroCoils for the treatment of cerebral aneurysms: experience with 110 cases. Paper 37","volume":"58","author":"Arthur","year":"2006"},{"issue":"2","key":"b2-1081241","series-title":"Neurosurg Focus","first-page":"E1","article-title":"Hydrogel-coated coils for the treatment of cerebral aneurysms: preliminary results","volume":"18","author":"Arthur","year":"2005"},{"key":"b3-1081241","series-title":"AJNR Am J Neuroradiol","first-page":"1834","article-title":"Treatment of cerebral aneurysms with hydrogel-coated platinum coils (HydroCoil): early single-center experience","volume":"27","author":"Berenstein","year":"2006"},{"key":"b4-1081241","series-title":"AJNR Am J Neuroradiol","first-page":"60","article-title":"Aneurysm packing with HydroCoil Embolic System versus platinum coils: initial clinical experience","volume":"25","author":"Cloft","year":"2004"},{"key":"b5-1081241","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"226","DOI":"10.3171\/jns.2007.106.2.226","article-title":"A prospective single-center analysis of the safety and efficacy of the hydrocoil embolization system for the treatment of intracranial aneurysms","volume":"106","author":"Deshaies","year":"2007"},{"key":"b6-1081241","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1161\/01.STR.0000221314.55144.0b","article-title":"Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy","volume":"37","author":"Gaba","year":"2006"},{"key":"b7-1081241","series-title":"J Leukoc Biol","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1189\/jlb.0103037","article-title":"Nondisposable materials, chronic inflammation, and adjuvant action","volume":"73","author":"Hamilton","year":"2003"},{"key":"b8-1081241","series-title":"AJNR Am J Neuroradiol","first-page":"1580","article-title":"New expandable hydrogel-platinum coil hybrid device for aneurysm embolization","volume":"23","author":"Kallmes","year":"2002"},{"key":"b9-1081241","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1227\/01.NEU.0000140987.71791.DF","article-title":"Chemical meningitis after cerebral aneurysm treatment using two second-generation aneurysm coils: report of two cases","volume":"55","author":"Meyers","year":"2004"},{"key":"b10-1081241","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1227\/01.NEU.0000043932.84900.70","article-title":"Shunt revision for asymptomatic failure: surgical and clinical results","volume":"52","author":"Vinchon","year":"2003"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/108\/6\/article-p1241.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/108\/6\/article-p1241.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/108\/6\/article-p1241.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,9]],"date-time":"2024-03-09T09:40:40Z","timestamp":1709977240000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/108\/6\/article-p1241.xml"}},"subtitle":["Report of 2 cases"],"short-title":[],"issued":{"date-parts":[[2008,6]]},"references-count":10,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/jns\/2008\/108\/6\/1241","relation":{},"ISSN":["0022-3085","1933-0693"],"issn-type":[{"value":"0022-3085","type":"print"},{"value":"1933-0693","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,6]]}}}