{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T14:12:41Z","timestamp":1791900761865,"version":"4.3.4"},"reference-count":54,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1990,12]]},"abstract":"<jats:p content-type=\"fine-print\">\u2713 Two types of artificial membranes, a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer, were tested as substitutes for dura in 24 and 12 rabbits, respectively. The films were placed either epidurally, subdurally, or as dural grafts in equal subgroups of animals. The postoperative course was uneventful with no manifestations of convulsive disorder or cerebrospinal fluid leak. The animals were sacrificed 3, 6, or 9 months after implantation of the artificial membranes. Both types of artificial membranes were easily removed from the underlying nervous and the other surrounding tissues. The histological examination failed to reveal adhesions, neomembrane formations, or any type of foreign body reactions to the polyurethane film. The implantation of the polysiloxane-carbonate film caused no reaction when it was applied epidurally. As a dural graft, the polysiloxane-carbonate copolymer induced the formation of a thin neomembrane of one to two layers of fibroblasts which formed a watertight seal of the dural defect. A similar thin neomembrane was found to encase this artificial membrane in the group of animals in which it was implanted subdurally. There was no foreign body reaction to the polysiloxane-carbonate film. The authors conclude that these materials hold promise as dural substitutes or in the prevention of spinal dural scarring, and should be evaluated clinically.<\/jats:p>","DOI":"10.3171\/jns.1990.73.6.0936","type":"journal-article","created":{"date-parts":[[2009,5,13]],"date-time":"2009-05-13T18:12:09Z","timestamp":1242238329000},"page":"936-941","source":"Crossref","is-referenced-by-count":32,"title":["Biologically inert synthetic dural substitutes"],"prefix":"10.3171","volume":"73","author":[{"given":"Damianos E.","family":"Sakas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Komporn","family":"Charnvises","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lawrence F.","family":"Borges","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas T.","family":"Zervas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Trans Am Surg Assoc","first-page":"490","article-title":"Rubber tissue for meningeal adhesions.","volume":"13","author":"Abbe","year":"1895"},{"key":"b2","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"770","DOI":"10.3171\/jns.1971.34.6.0770","article-title":"Clinical results of lyophilized human cadaver dura transplantation.","volume":"34","author":"Abbot","year":"1971"},{"key":"b3","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"295","DOI":"10.3171\/jns.1983.58.2.0295","article-title":"The role of neomembranes in formation of hematoma around Silastic dura substitute. Case report.","volume":"58","author":"Adegbite","year":"1983"},{"key":"b4","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"545","DOI":"10.3171\/jns.1962.19.7.0545","article-title":"Nonsuture sealing of a dural substitute utilizing a plastic adhesive, methyl 2-cyanoacrylate.","volume":"19","author":"Albin","year":"1962"},{"key":"b5","series-title":"Trans Am Soc Artif Intern Organs","first-page":"209","article-title":"An elastomericvascular prosthesis.","volume":"24","author":"Annis","year":"1978"},{"key":"b6","series-title":"J Clin Invest","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1172\/JCI101529","article-title":"Chemical, clinical, and immunological studies of human plasma fractionation. XXII. Fibrin films in neurosurgery, with special reference to their use in the repair of dural defects and in the prevention of meningocerebral adhesions.","volume":"23","author":"Bailey","year":"1944"},{"key":"b7","series-title":"Am Surg","first-page":"434","article-title":"Unusual complications with use of Silastic dural substitute.","volume":"40","author":"Banerjee","year":"1974"},{"key":"b8","series-title":"Neurochirurgia","first-page":"45","article-title":"Silicone coated Dacron for enlargement of dural canal in cervical disc surgery. A preliminary report.","volume":"13","author":"Bartal","year":"1970"},{"key":"b9","series-title":"Boston Med Surg J","first-page":"281","article-title":"Gold foil in general surgery.","volume":"126","author":"Beach","year":"1897"},{"key":"b10","series-title":"J Biomed Mater Res","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1002\/jbm.820090308","article-title":"Surface and bulk characteristics of a polyether urethane for artificial hearts.","volume":"9","author":"Boretos","year":"1975"},{"key":"b11","series-title":"J Biomed Mater Res","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1002\/jbm.820070405","article-title":"Development of ablock copolyether-urethane intra-aortic balloons and other medical devices.","volume":"7","author":"Brash","year":"1973"},{"key":"b12","series-title":"Acta Chir Scand","first-page":"410","article-title":"Gelatine and polyethlene film as dura substitutes and polyethene plates as bone substitutes in skull defects.","volume":"97","author":"Busch","year":"1948"},{"key":"b13","series-title":"Br Med J","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1136\/bmj.1.4134.517","article-title":"A new method of preventing adhesions. The use of amnioplastin after craniotomy.","volume":"1","author":"Chao","year":"1940"},{"key":"b14","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"633","DOI":"10.3171\/jns.1989.70.4.0633","article-title":"Inflammatory reaction to synthetic dural substitute. Case report.","volume":"70","author":"Cohen","year":"1989"},{"key":"b15","series-title":"Surg Gynecol Obstet","first-page":"449","article-title":"The indications and technique for the use of a subdural patch.","volume":"136","author":"Collis","year":"1973"},{"key":"b16","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"57","DOI":"10.3171\/jns.1966.25.1.0057","article-title":"Cervical spondylotic myelopathy.","volume":"25","author":"Crandall","year":"1966"},{"key":"b17","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"258","DOI":"10.3171\/jns.1954.11.3.0258","article-title":"Use of polyvinyl sponge in neurosurgery.","volume":"11","author":"Dodge","year":"1954"},{"key":"b18","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1227\/00006123-198312000-00020","article-title":"Cervical myelopathy from dural substitute.","volume":"13","author":"Fisher","year":"1983"},{"key":"b19","series-title":"Trans Am Soc Artif Intern Organs","first-page":"571","article-title":"Mitrathane: a new polyether urethane urea for critical medical applications.","volume":"30","author":"Gilding","year":"1984"},{"key":"b20","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"550","DOI":"10.3171\/jns.1955.12.6.0550","article-title":"The use of Orion for dural replacement.","volume":"12","author":"Huertas","year":"1955"},{"key":"b21","series-title":"JAMA","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1001\/jama.1947.02890020012005","article-title":"Polyethylene, a new synthetic plastic for use in surgery. Experimental applications in neurosurgery.","volume":"135","author":"Ingraham","year":"1947"},{"key":"b22","series-title":"Surg Forum","first-page":"435","article-title":"Formaldehyde-treated, regenerated collagen film and film-laminate as a substitute for dura mater.","volume":"16","author":"Jannetta","year":"1965"},{"key":"b23","series-title":"Biomater Med Devices Artif Organs","doi-asserted-by":"publisher","first-page":"387","DOI":"10.3109\/10731197409118608","article-title":"Design, fabrication and testing of prosthetic blood vessels.","volume":"2","author":"Kardos","year":"1974"},{"key":"b24","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"412","DOI":"10.3171\/jns.1978.49.3.0412","article-title":"The fate of autogenous grafts to the spinal dura. An experimental study.","volume":"49","author":"Keller","year":"1978"},{"key":"b25","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.3171\/jns.1984.60.5.1022","article-title":"Repair of spinal dural defects. An experimental study.","volume":"60","author":"Keller","year":"1984"},{"key":"b26","series-title":"Arch Surg","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1001\/archsurg.1965.01320180058014","article-title":"Dural replacement with resorbable collagen.","volume":"91","author":"Kline","year":"1965"},{"key":"b27","series-title":"Biomater Med Devices Artif Organs","first-page":"1","article-title":"Small diameter vascular grafts: physical property evaluation.","volume":"14","author":"Kogliwi","year":"1986"},{"key":"b28","series-title":"Polymers Med","first-page":"277","article-title":"Tissue reaction to polyurethane KL-3 adhesive.","volume":"4","author":"Kovalev","year":"1974"},{"key":"b29","series-title":"Biocompatibility Studies of Poly(Dimethylsiloxane)-Bisphenol-A Carbonate Block Copolymers.","author":"Lawton","year":"1974"},{"key":"b30","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"558","DOI":"10.3171\/jns.1967.27.6.0558","article-title":"Experimental evaluation of silicone-coated Dacron and collagen fabric-film laminate as dural substitutes.","volume":"27","author":"Lee","year":"1967"},{"key":"b31","series-title":"J Polymer Sci","first-page":"239","article-title":"Some chemical aspects of the behavior of synthetic polymers in a living organism.","volume":"66","author":"Lipatova","year":"1979"},{"key":"b32","series-title":"Trans Am Soc Artif Intern Organs","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/00002480-197700230-00067","article-title":"Development of small diameter vascular prosthesis.","volume":"23","author":"Lyman","year":"1977"},{"key":"b33","series-title":"Trans Am Soc Artif Intern Organs","first-page":"456","article-title":"The development and implantation of a polyurethane hemispherical artificial heart.","volume":"17","author":"Lyman","year":"1979"},{"key":"b34","series-title":"Am J Med Sci","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1097\/00000441-189805000-00004","article-title":"The surgical treatment of epilepsy, withreport of fourteen cases.","volume":"115","author":"McCosh","year":"1898"},{"key":"b35","series-title":"Trans Am Soc Artif Intern Organs","first-page":"50","article-title":"Fabrication and long-term implantation of semi-compliant small vascular prosthesis.","volume":"31","author":"Murabayashi","year":"1985"},{"key":"b36","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"351","DOI":"10.3171\/jns.1984.61.2.0351","article-title":"Use of porcine dermis as a dural substitute in 72 patients.","volume":"61","author":"O'Neill","year":"1984"},{"key":"b37","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.3171\/jns.1984.60.5.1076","article-title":"An unusual complication of Dura Film as dural substitute. Report of two cases.","volume":"60","author":"Ongkiko","year":"1984"},{"key":"b38","series-title":"Pace","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1111\/j.1540-8159.1983.tb04406.x","article-title":"Thermoplastic polyurethanes as insulating materials for long-life cardiac pacing leads.","volume":"6","author":"Panole","year":"1983"},{"key":"b39","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1227\/00006123-198001000-00009","article-title":"Repair of spinal cerebrospinal fistula with the use of a tissue adhesive: technical note.","volume":"6","author":"Papadakis","year":"1980"},{"key":"b40","series-title":"Synthetic Biomedical Polymers, Concepts and Applications.","first-page":"39","article-title":"The use of segmented polyurethane in ventricular assist devices and artificial hearts","author":"Philips","year":"1980"},{"key":"b41","series-title":"Polymers in Medicine and Surgery.","first-page":"263","article-title":"Polymers in biomedical devices: materials for artificial heart and circulatory assist devices","author":"Pierce","year":"1975"},{"key":"b42","series-title":"Trans Am Soc Artif Intern Organs","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1097\/00002480-197902500-00057","article-title":"Comprehensive real time endurance testing.","volume":"25","author":"Poirier","year":"1979"},{"key":"b43","series-title":"Surgery","first-page":"318","article-title":"Meningocerebral adhesions. An experimental study of the effect of human amniotic membrane, amnioplastin, beef allantoic membrane, cargile membrane, tantalum foil, and polyvinyl alcohol films.","volume":"12","author":"Pudenz","year":"1942"},{"key":"b44","series-title":"Br Med J","first-page":"518","article-title":"Epilepsy treated by subdural implantation of silver foil.","volume":"1","author":"Ray","year":"1901"},{"key":"b45","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"197","DOI":"10.3171\/jns.1959.16.2.0197","article-title":"Ethylene oxide sterilized, freeze-dried dura mater for the repair of pachymeningeal defects.","volume":"16","author":"Rosomoff","year":"1959"},{"key":"b46","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"192","DOI":"10.3171\/jns.1958.15.2.0192","article-title":"Lyophilized human dura mater as a dural substitute.","volume":"15","author":"Sharkey","year":"1958"},{"key":"b47","series-title":"Trans Am Soc Artif Intern Organs","first-page":"240","article-title":"The medical silicones.","volume":"10","author":"Silas","year":"1964"},{"key":"b48","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"408","DOI":"10.3171\/jns.1984.60.2.0408","article-title":"Recurrent subarachnoid bleeding in association with dural substitute. Report of three cases.","volume":"60","author":"Simpson","year":"1984"},{"key":"b49","series-title":"Biomaterials","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/0142-9612(82)90024-2","article-title":"Polyether urethanes for implantable pacemaker leads.","volume":"3","author":"Stokes","year":"1982"},{"key":"b50","series-title":"J Biomater Appl","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1177\/088532828800300207","article-title":"The biostability of polyurethane elastomers: a critical review.","volume":"3","author":"Szycher","year":"1988"},{"key":"b51","series-title":"Elastomerics","first-page":"20","article-title":"Polyurethane elastomers in specific medical applications.","volume":"116","author":"Szycher","year":"1984"},{"key":"b52","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"591","DOI":"10.3171\/jns.1955.12.6.0591","article-title":"Vinyon \u201cN\u201d as a dural substitute. An experimental study in the monkey.","volume":"12","author":"Teng","year":"1955"},{"key":"b53","series-title":"J Neurol Neurosurg Psychiatry","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1136\/jnnp.26.3.244","article-title":"The use of Teflon as a dural substitute and its other neurosurgical applications.","volume":"26","author":"Teng","year":"1963"},{"key":"b54","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"151","DOI":"10.3171\/jns.1970.33.2.0151","article-title":"Repair of cerebrospinal fluid fistulas using a tissue adhesive.","volume":"33","author":"VanderArk","year":"1970"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/73\/6\/article-p936.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/73\/6\/article-p936.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/73\/6\/article-p936.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,20]],"date-time":"2023-03-20T01:47:41Z","timestamp":1679276861000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/73\/6\/article-p936.xml"}},"subtitle":["Appraisal of a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer"],"short-title":[],"issued":{"date-parts":[[1990,12]]},"references-count":54,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/jns.1990.73.6.0936","relation":{},"ISSN":["0022-3085"],"issn-type":[{"value":"0022-3085","type":"print"}],"subject":[],"published":{"date-parts":[[1990,12]]}}}