{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,3,9]],"date-time":"2024-03-09T10:18:51Z","timestamp":1709979531769},"reference-count":7,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1991,6]]},"abstract":"<jats:p content-type=\"fine-print\">\u2713 A new method for evaluating the patency of a ventriculoatrial shunt is described, and early experience with it is reported. Transesophageal echocardiography can demonstrate a cerebrospinal fluid leak in the right atrium through the atrial tip of a shunting device. This capability was an incidental discovery, and since then the accuracy of the technique in evaluating the patency of a ventriculoatrial shunt has been prospectively studied in 20 observations of 16 patients. The method proved to be accurate in 90% to 100% of cases. It is concluded that transesophageal echocardiography offers a rapid and accurate assessment of ventriculoatrial shunt function, is well tolerated, and is easy to perform.<\/jats:p>","DOI":"10.3171\/jns.1991.74.6.1018","type":"journal-article","created":{"date-parts":[[2009,5,19]],"date-time":"2009-05-19T16:22:10Z","timestamp":1242750130000},"page":"1018-1020","source":"Crossref","is-referenced-by-count":9,"title":["Transesophageal echocardiography: a simple method for monitoring the patency of ventriculoatrial shunts"],"prefix":"10.3171","volume":"74","author":[{"given":"Luc","family":"Calliauw","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johan","family":"Vandenbogaerde","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Okito","family":"Kalala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacques","family":"Caemaert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fr\u00e9d\u00e9ric","family":"Martens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom","family":"Vandekerckhove","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Int J Cardiol Imag","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/BF01745227","article-title":"The initial clinical application of a transesophageal system with pulsed Doppler, continuous wave Doppler and color flow imaging based on an annular array technology.","volume":"5","author":"Chapman","year":"1989"},{"key":"b2","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"121","DOI":"10.3171\/jns.1976.44.1.0121","article-title":"A simple test of shunt function: the shuntgram. Technical note.","volume":"44","author":"Dewey","year":"1976"},{"key":"b3","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"743","DOI":"10.3171\/jns.1966.24.4.0743","article-title":"Evaluation of surgical and spontaneous cerebrospinal fluid shunts by isotope scanning.","volume":"24","author":"Di Chiro","year":"1966"},{"key":"b4","series-title":"Childs Brain","first-page":"25","article-title":"Correlation of the response of the flushing device to compression with the clinical picture in the evaluation of the functional status of the shunting system.","volume":"3","author":"Osaka","year":"1977"},{"key":"b5","series-title":"Childs Nerv Syst","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1007\/BF00735730","article-title":"In vitro evaluation of CSF shunt function by radionuclides.","volume":"1","author":"Pendleton","year":"1985"},{"key":"b6","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"398","DOI":"10.3171\/jns.1978.49.3.0398","article-title":"Determination of cerebrospinal fluid shunt function with water-soluble contrast medium.","volume":"49","author":"Savoiardo","year":"1978"},{"key":"b7","series-title":"Mayo Clin Proc","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/S0025-6196(12)65529-3","article-title":"Transesophageal echocardiography: technique, anatomic correlations, implementation, and clinical applications.","volume":"63","author":"Seward","year":"1988"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/74\/6\/article-p1018.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/74\/6\/article-p1018.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/74\/6\/article-p1018.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T20:16:25Z","timestamp":1679861785000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/74\/6\/article-p1018.xml"}},"subtitle":["Technical note"],"short-title":[],"issued":{"date-parts":[[1991,6]]},"references-count":7,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/jns.1991.74.6.1018","relation":{},"ISSN":["0022-3085"],"issn-type":[{"value":"0022-3085","type":"print"}],"subject":[],"published":{"date-parts":[[1991,6]]}}}