{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T17:38:31Z","timestamp":1790530711058,"version":"4.1.0"},"reference-count":43,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1999,11]]},"abstract":"<jats:p content-type=\"fine-print\"><jats:italic>Object.<\/jats:italic> The authors' goal was to place a mobile, 1.5-tesla magnetic resonance (MR) imaging system into a neurosurgical operating room without adversely affecting established neurosurgical management. The system would help to plan accurate surgical corridors, confirm the accomplishment of operative objectives, and detect acute complications such as hemorrhage or ischemia.<\/jats:p><jats:p content-type=\"fine-print\"><jats:italic>Methods.<\/jats:italic> The authors used an actively shielded 1.5-tesla magnet, together with 15 mtesla\/m gradients, MR console computers, gradient amplifiers, a titanium, hydraulic-controlled operating table, and a radiofrequency coil that can be disassembled. The magnet is moved to and from the surgical field by using overhead crane technology. To date, the system has provided unfettered access in 46 neurosurgical patients.<\/jats:p><jats:p content-type=\"fine-print\">In all patients, high-definition T<jats:sub>1<\/jats:sub>- and\/or T<jats:sub>2<\/jats:sub>-weighted images were rapidly and reproducibly acquired at various stages of the surgical procedures. Eleven patients underwent craniotomy that was optimized after preincision imaging. In four patients who harbored subtotally resected tumor, intraoperative MR imaging aided the surgeon in removing the remaining tumor. Interestingly, the intraoperative administration of gadolinium demonstrated a dynamic expansion of enhancement beyond the preoperative contrast contour in patients with malignant glioma. These zones of new enhancement proved, on examination of biopsy samples, to be tumor.<\/jats:p><jats:p content-type=\"fine-print\"><jats:italic>Conclusions.<\/jats:italic> The authors have demonstrated that high-quality MR images can be obtained in the operating room within reasonable time constraints. Procedures can be conducted without compromising or altering traditional neurosurgical, nursing, or anesthetic techniques. It is feasible that within the next decade intraoperative MR imaging may become the standard of care in neurosurgery.<\/jats:p>","DOI":"10.3171\/jns.1999.91.5.0804","type":"journal-article","created":{"date-parts":[[2009,5,13]],"date-time":"2009-05-13T17:20:08Z","timestamp":1242235208000},"page":"804-813","source":"Crossref","is-referenced-by-count":221,"title":["A mobile high-field magnetic resonance system for neurosurgery"],"prefix":"10.3171","volume":"91","author":[{"given":"Garnette R.","family":"Sutherland","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taro","family":"Kaibara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deon","family":"Louw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David I.","family":"Hoult","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boguslaw","family":"Tomanek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Saunders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Neurosurgery","first-page":"45","article-title":"Early postoperative magnetic resonance imaging after resection of malignant glioma: objective evaluation of residual tumor and its influence on regrowth and prognosis.","volume":"34","author":"Albert","year":"1994"},{"key":"b2","series-title":"Stereotact Funct Neurosurg","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1159\/000099896","article-title":"The present and future role of intraoperative MRI in neurosurgical procedures.","volume":"68","author":"Alexander","year":"1997"},{"key":"b3","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"447","DOI":"10.3171\/jns.1991.74.3.0447","article-title":"Characterization of astrocytomas, meningiomas, and pituitary adenomas by phosphorus magnetic resonance spectroscopy.","volume":"74","author":"Arnold","year":"1991"},{"key":"b4","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"510","DOI":"10.3171\/jns.1993.78.3.0510","article-title":"Intraoperative localization using an armless, frameless stereotactic wand. Technical note.","volume":"78","author":"Barnett","year":"1993"},{"key":"b5","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1227\/00006123-199202000-00001","article-title":"Intraoperative angiography in the management of neurovascular disorders.","volume":"30","author":"Barrow","year":"1992"},{"key":"b6","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1097\/00006123-199710000-00013","article-title":"Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications.","volume":"41","author":"Black","year":"1997"},{"key":"b7","series-title":"Bull Soc Anat Paris","first-page":"398","article-title":"Nouvelle observation d'aph\u00e9mie produite par une lesion de la moiti\u00e9 post\u00e9rieure des deuxi\u00e8me et troisi\u00e8me circonvolutions frontales gauches.","volume":"6","author":"Broca","year":"1861"},{"key":"b8","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"157","DOI":"10.3171\/jns.1982.57.2.0157","article-title":"Intraoperative use of real-time ultrasonography in neurosurgery.","volume":"57","author":"Chandler","year":"1982"},{"key":"b9","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1227\/00006123-198707000-00005","article-title":"Supratentorial gliomas: surgical considerations and immediate postoperative results. Gross total resection versus partial resection.","volume":"21","author":"Ciric","year":"1987"},{"key":"b10","series-title":"Ann Surg","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1097\/00000658-191910000-00004","article-title":"Roentgenography of the brain after the injection of air into the spinal canal.","volume":"70","author":"Dandy","year":"1919"},{"key":"b11","series-title":"Nature","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1038\/308225a0","article-title":"Radiography of the living brain.","volume":"308","author":"Darius","year":"1984"},{"key":"b12","series-title":"AJNR","first-page":"307","article-title":"Intraoperative digital subtraction angiography: a review of 112 consecutive examinations.","volume":"16","author":"Derdeyn","year":"1995"},{"key":"b13","series-title":"Neurol Clin","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/S0733-8619(18)31047-8","article-title":"Dynamic intraoperative imaging and instrumentation of brain and spinal cord using ultrasound.","volume":"3","author":"Dohrmann","year":"1985"},{"key":"b14","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"656","DOI":"10.3171\/jns.1998.88.4.0656","article-title":"Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation.","volume":"88","author":"Dorward","year":"1998"},{"key":"b15","series-title":"J Clin Oncol","doi-asserted-by":"publisher","first-page":"2076","DOI":"10.1200\/JCO.1997.15.5.2076","article-title":"Prospective study of postoperative magnetic resonance imaging in patients with malignant gliomas.","volume":"15","author":"Forsyth","year":"1997"},{"key":"b16","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"197","DOI":"10.3171\/jns.1995.83.2.0197","article-title":"Clinical use of a frameless stereotactic arm: results of 325 cases.","volume":"83","author":"Golfinos","year":"1995"},{"key":"b17","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"174","DOI":"10.3171\/jns.1996.84.2.0174","article-title":"Early postoperative magnetic resonance imaging following nonneoplastic cortical resection.","volume":"84","author":"Henegar","year":"1996"},{"key":"b18","series-title":"Magn Reson Med","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1002\/mrm.1910160307","article-title":"A high-sensitivity, high-B1 homogeneity probe for quantitation of metabolites.","volume":"16","author":"Hoult","year":"1990"},{"key":"b19","article-title":"Surgical procedure with magnetic resonance imaging.","author":"Hoult"},{"key":"b20","series-title":"Magn eson Med","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1002\/mrm.1910390208","article-title":"Automatic probe tuning and matching.","volume":"39","author":"Hwang","year":"1998"},{"key":"b21","article-title":"Tuning and matching an impedance (automatic matching and tuning RF coil for the intraoperative).","author":"Hwang","year":"1999"},{"key":"b22","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"339","DOI":"10.3171\/jns.1999.90.2.0339","article-title":"Hypothermia: depression of tricarboxylic acid cycle flux and evidence for pentose phosphate shunt upregulation.","volume":"90","author":"Kaibara","year":"1999"},{"key":"b23","series-title":"Biochem Cell Biol","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1139\/o98-048","article-title":"Human cerebral neoplasms studied using MR spectroscopy: a review.","volume":"76","author":"Kaibara","year":"1998"},{"key":"b24","series-title":"Radiologe","first-page":"218","article-title":"[Intraoperative magnetic resonance tomography for control of extent of neurosurgical operations.]","volume":"38","author":"Knauth","year":"1998"},{"key":"b25","series-title":"Functional and Stereotactic Neurosurgery.","first-page":"51","article-title":"The Leksell stereotactic system","author":"Lunsford","year":"1998"},{"key":"b26","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1097\/00006123-199810000-00006","article-title":"Comment on Steinmeier R, Fahlbusch R, Ganslandt O, et al: Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report.","volume":"43","author":"Lunsford","year":"1998"},{"key":"b27","series-title":"Appl Neurophysiol","first-page":"374","article-title":"A dedicated CT system for the stereotactic operating room.","volume":"45","author":"Lunsford","year":"1982"},{"key":"b28","series-title":"Stereotact Funct Neurosurg","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1159\/000099668","article-title":"Intraoperative imaging of the brain.","volume":"66","author":"Lunsford","year":"1996"},{"key":"b29","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1227\/00006123-198410000-00017","article-title":"Intraoperative imaging with a therapeutic computed tomographic scanner.","volume":"15","author":"Lunsford","year":"1984"},{"key":"b30","series-title":"Surg Neurol","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/0090-3019(82)90369-X","article-title":"Stereotactic surgery using the \u201ctherapeutic\u201d CT scanner.","volume":"18","author":"Lunsford","year":"1982"},{"key":"b31","series-title":"Stereotact Funct Neurosurg","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1159\/000098982","article-title":"A universal system for interactive image-directed neurosurgery.","volume":"58","author":"Maciunas","year":"1992"},{"key":"b32","series-title":"Cancer","doi-asserted-by":"publisher","first-page":"2727","DOI":"10.1002\/1097-0142(19950601)75:11<2727::AID-CNCR2820751115>3.0.CO;2-H","article-title":"Prognostic implications of the extent of surgical resection in patients with intracranial malignant gliomas.","volume":"75","author":"Nitta","year":"1995"},{"key":"b33","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.3171\/jns.1978.48.6.1038","article-title":"A new combined neurosurgical headholder and cassette changer for intraoperative serial angiography. Technical note.","volume":"48","author":"Parkinson","year":"1978"},{"key":"b34","series-title":"Magn Reson Med","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1002\/mrm.1910240113","article-title":"High-resolution 1H NMR spectroscopy studies of extracts of human cerebral neoplasms.","volume":"24","author":"Peeling","year":"1992"},{"key":"b35","series-title":"Nat Med","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1038\/nm0396-323","article-title":"Accurate, noninvasive diagnosis of human brain tumors by using proton magnetic resonance spectroscopy.","volume":"2","author":"Preul","year":"1996"},{"key":"b36","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1097\/00006123-199810000-00010","article-title":"Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases.","volume":"43","author":"Roberts","year":"1998"},{"key":"b37","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1097\/00006123-199810000-00005","article-title":"Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report.","volume":"43","author":"Steinmeier","year":"1998"},{"key":"b38","series-title":"Diabetes","doi-asserted-by":"publisher","first-page":"1328","DOI":"10.2337\/diab.41.10.1328","article-title":"Forebrain ischemia in diabetic and nondiabetic BB rats studied with 31P magnetic resonance spectroscopy.","volume":"41","author":"Sutherland","year":"1992"},{"key":"b39","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1097\/00006123-199810000-00006","article-title":"Comment on Steinmeier R, Fahlbusch R, Ganslandt, O, et al: Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report.","volume":"43","author":"Tronnier","year":"1998"},{"key":"b40","series-title":"Stroke","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1161\/01.STR.27.5.957","article-title":"23Na nuclear magnetic resonance spectral changes during and after forebrain ischemia in hypoglycemic, normoglycemic, and hyperglycemic rats.","volume":"27","author":"Tyson","year":"1996"},{"key":"b41","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1227\/00006123-199106000-00002","article-title":"Open surgery assisted by the neuronavigator, a stereotactic, articulated, sensitive arm.","volume":"28","author":"Watanabe","year":"1991"},{"key":"b42","series-title":"Ultrasound Med Biol","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/0301-5629(92)90126-U","article-title":"The early development of neurosonology: I. Echoencephalography in adults.","volume":"18","author":"White","year":"1992"},{"key":"b43","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"487","DOI":"10.3171\/jns.1989.71.4.0487","article-title":"Supratentorial anaplastic gliomas in adults. The prognostic importance of extent of resection and prior low-grade glioma.","volume":"71","author":"Winger","year":"1989"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/91\/5\/article-p804.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/91\/5\/article-p804.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/91\/5\/article-p804.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T01:45:30Z","timestamp":1679881530000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/91\/5\/article-p804.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,11]]},"references-count":43,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.3171\/jns.1999.91.5.0804","relation":{},"ISSN":["0022-3085"],"issn-type":[{"value":"0022-3085","type":"print"}],"subject":[],"published":{"date-parts":[[1999,11]]}}}