{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T05:19:00Z","timestamp":1780636740842,"version":"3.54.1"},"reference-count":23,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2002,6]]},"abstract":"<jats:p content-type=\"fine-print\"><jats:italic>Object.<\/jats:italic> The routine use of intraoperative angiography as an aid in the surgical treatment of aneurysms is uncommon. The advantages of the ability to visualize residual aneurysm or unintended occlusion of parent vessels intraoperatively must be weighed against the complications associated with repeated angiography and prolonged vascular access. The authors reviewed the results of their routine use of intraoperative angiography to determine its safety and efficacy.<\/jats:p>\n<jats:p content-type=\"fine-print\"><jats:italic>Methods.<\/jats:italic> Prospectively gathered data from all aneurysm cases treated surgically between January 1996 and June 2000 were reviewed. A total of 303 operations were performed in 284 patients with aneurysms; 24 patients also underwent postoperative angiography. Findings on intraoperative angiographic studies prompted reexploration and clip readjustment in 37 (11%) of the 337 aneurysms clipped. Angiography revealed parent vessel occlusion in 10 cases (3%), residual aneurysm in 22 cases (6.5%), and both residual lesion and parent vessel occlusion in five cases (1.5%). When compared with subsequent postoperative imaging, false-negative results were found on two intraoperative angiograms (8.3%) and a false-positive result was found on one (4.2%). Postoperative angiograms obtained in both false-negative cases revealed residual anterior communicating artery aneurysms. Both of these aneurysms also subsequently rebled, requiring reoperation. In the group that underwent intraoperative angiography, in 303 operations eight patients (2.6%) suffered complications, of which only one was neurological.<\/jats:p>\n<jats:p content-type=\"fine-print\"><jats:italic>Conclusions.<\/jats:italic> In the surgical treatment of intracranial aneurysms, the use of routine intraoperative angiography is safe and helpful in a significant number of cases, although it does not replace careful intraoperative inspection of the surgical field.<\/jats:p>","DOI":"10.3171\/jns.2002.96.6.0988","type":"journal-article","created":{"date-parts":[[2009,5,13]],"date-time":"2009-05-13T17:44:46Z","timestamp":1242236686000},"page":"988-992","source":"Crossref","is-referenced-by-count":154,"title":["Routine intraoperative angiography during aneurysm surgery"],"prefix":"10.3171","volume":"96","author":[{"given":"Veronica L.","family":"Chiang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillipe","family":"Gailloud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kieran J.","family":"Murphy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniele","family":"Rigamonti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafael J.","family":"Tamargo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1097\/00006123-199607000-00004","article-title":"Intraoperative angiography in cerebral aneurysm surgery: a prospective study of 100 craniotomies.","volume":"39","author":"Alexander","year":"1996"},{"key":"b2","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"752","DOI":"10.3171\/jns.1963.20.9.0752","article-title":"Postoperative angiography in cases of ruptured intracranial aneurysm.","volume":"20","author":"Allcock","year":"1963"},{"key":"b3","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1227\/00006123-199202000-00001","article-title":"Intraoperative angiography in the management of neurovascular disorders.","volume":"30","author":"Barrow","year":"1992"},{"key":"b4","series-title":"AJNR","first-page":"307","article-title":"Intraoperative digital subtraction angiography: a review of 112 consecutive examinations.","volume":"16","author":"Derdeyn","year":"1995"},{"key":"b5","series-title":"Radiology","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1148\/radiology.205.2.9356612","article-title":"Intracranial aneurysm: anatomic factors that predict the usefulness of intraoperative angiography.","volume":"205","author":"Derdeyn","year":"1997"},{"key":"b6","series-title":"AJNR","first-page":"300","article-title":"Radiation dose to patients and personnel during intraoperative digital subtraction angiography.","volume":"20","author":"Derdeyn","year":"1999"},{"key":"b7","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"226","DOI":"10.3171\/jns.1967.27.3.0226","article-title":"The late consequences of incomplete surgical treatment of cerebral aneurysms.","volume":"27","author":"Drake","year":"1967"},{"key":"b8","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"30","DOI":"10.3171\/jns.1987.66.1.0030","article-title":"Natural history of postoperative aneurysm rests.","volume":"66","author":"Feuerberg","year":"1987"},{"key":"b9","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"387","DOI":"10.3171\/jns.1995.83.3.0387","article-title":"Reoperative management of intracranial aneurysms.","volume":"83","author":"Giannotta","year":"1995"},{"key":"b10","series-title":"AJNR","first-page":"759","article-title":"Intraoperative digital subtraction neuroangiography: a diagnostic and therapeutic tool.","volume":"8","author":"Hieshima","year":"1987"},{"key":"b11","series-title":"Acta Neurochir","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1007\/BF01456349","article-title":"Per-operative angiography\u2014a useful tool in cerebral aneurysm surgery?","volume":"84","author":"Hillman","year":"1987"},{"key":"b12","series-title":"Neurosurgery","first-page":"629","article-title":"Routine angiography after surgery for ruptured intracranial aneurysms: a cost versus benefit analysis.","volume":"41","author":"Kallmes","year":"1997"},{"key":"b13","series-title":"Acta Neurochir","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/s007010050279","article-title":"Bleeding risk in unruptured and residual cerebral aneurysms\u2014angiographic annual growth rate in nineteen patients.","volume":"141","author":"Kamitani","year":"1999"},{"key":"b14","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1097\/00006123-199806000-00026","article-title":"Risks and benefits of diagnostic angiography after aneurysm surgery: a retrospective analysis of 597 studies.","volume":"42","author":"LeRoux","year":"1998"},{"key":"b15","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"556","DOI":"10.3171\/jns.1989.70.4.0556","article-title":"Regrowth of aneurysm sacs from residual neck following aneurysm clipping.","volume":"70","author":"Lin","year":"1989"},{"key":"b16","series-title":"Acta Radiol (Diagn)","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1177\/02841851660050P140","article-title":"Applications of angiography during intracranial operation.","volume":"5","author":"Loop","year":"1966"},{"key":"b17","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"826","DOI":"10.3171\/jns.1993.79.6.0826","article-title":"Role of angiography following aneurysm surgery.","volume":"79","author":"Macdonald","year":"1993"},{"key":"b18","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"526","DOI":"10.3171\/jns.1990.73.4.0526","article-title":"Intraoperative digital subtraction angiography and the surgical treatment of intracranial aneurysms and vascular malformations.","volume":"73","author":"Martin","year":"1990"},{"key":"b19","series-title":"Surg Neurol","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/S0090-3019(97)00529-6","article-title":"Optimal clip application and intraoperative angiography for intracranial aneurysms.","volume":"51","author":"Origitano","year":"1999"},{"key":"b20","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"441","DOI":"10.3171\/jns.1998.88.3.0441","article-title":"Role of intraoperative angiography in the surgical treatment of cerebral aneurysms.","volume":"88","author":"Payner","year":"1998"},{"key":"b21","series-title":"Surg Neurol","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/S0090-3019(97)00035-9","article-title":"Angiography after aneurysm surgery: indications for \u201cselective\u201d angiography.","volume":"49","author":"Rauzzino","year":"1998"},{"key":"b22","series-title":"J Neurosurg","first-page":"148","article-title":"Postoperative angiography.","volume":"82","author":"Vajda","year":"1995"},{"key":"b23","series-title":"AJNR","first-page":"1457","article-title":"Utility, safety, and accuracy of intraoperative angiography in the surgical treatment of aneurysms and arteriovenous malformations.","volume":"20","author":"Vitaz","year":"1999"}],"container-title":["Journal of Neurosurgery"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/96\/6\/article-p988.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/96\/6\/article-p988.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg\/96\/6\/article-p988.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T21:42:25Z","timestamp":1679866945000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg\/96\/6\/article-p988.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,6]]},"references-count":23,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/jns.2002.96.6.0988","relation":{},"ISSN":["0022-3085"],"issn-type":[{"value":"0022-3085","type":"print"}],"subject":[],"published":{"date-parts":[[2002,6]]}}}