{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T11:11:30Z","timestamp":1792062690619,"version":"4.4.0"},"reference-count":22,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2001,1]]},"abstract":"<jats:p content-type=\"fine-print\">\n                    <jats:italic>Object.<\/jats:italic>\n                    The authors sought to create and to evaluate an in vitro model of Grade I degenerative (closed-arch) spondylolisthesis.\n                  <\/jats:p>\n                  <jats:p content-type=\"fine-print\">\n                    <jats:italic>Methods.<\/jats:italic>\n                    The model of spondylolisthesis was created by two primary procedures: 1) resection of the disc; and 2) stripping of anterior and posterior longitudinal ligaments away from the vertebral bodies (VBs). In 13 vertebral levels obtained from three cadaveric lumbar spines, the tissues were resected sequentially in alternating order to determine the relative contribution of each resection to spinal instability. The entire specimens were loaded with nonconstraining torques and then individual levels were loaded with anteroposterior shear forces. The motion values were measured optoelectronically for each specimen at individual levels.\n                  <\/jats:p>\n                  <jats:p content-type=\"fine-print\">\n                    <jats:italic>Conclusions.<\/jats:italic>\n                    The integrity of the disc was more important than attachment of the ligaments to the VB, but the resection of both structures was necessary to achieve substantial destabilization. The structures of the spine are highly resilient, and destabilization is difficult to achieve without performing extensive resection. Using the techniques described in this paper to alter normal spines, a level of spinal instability (Grade I; 25% slippage) that may represent spondylolisthesis can be modeled in vitro.\n                  <\/jats:p>","DOI":"10.3171\/spi.2001.94.1.0045","type":"journal-article","created":{"date-parts":[[2009,5,7]],"date-time":"2009-05-07T11:55:30Z","timestamp":1241697330000},"page":"45-50","source":"Crossref","is-referenced-by-count":11,"title":["Biomechanics of Grade I degenerative lumbar spondylolisthesis. Part 1: In vitro model"],"prefix":"10.3171","volume":"94","author":[{"given":"Neil R.","family":"Crawford","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sedat","family":"\u00c7agli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Volker K. H.","family":"Sonntag","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Curtis A.","family":"Dickman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1097\/00007632-198912000-00019","article-title":"Biomechanical analysis of pedicle screw instrumentation systems in a corpectomy model.","volume":"14","author":"Ashman","year":"1989"},{"key":"b2","series-title":"J Bone Joint Surg (Am)","doi-asserted-by":"publisher","first-page":"403","DOI":"10.2106\/00004623-199603000-00012","article-title":"Orientation of the lumbar facet joints: association with degenerative disc disease.","volume":"78","author":"Boden","year":"1996"},{"key":"b3","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2097","DOI":"10.1097\/00007632-199510000-00005","article-title":"An apparatus for applying pure nonconstraining moments to spine segments in vitro.","volume":"20","author":"Crawford","year":"1995"},{"key":"b4","series-title":"Spine","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1097\/00007632-199703010-00020","article-title":"Construction of local vertebral coordinate systems using a digitizing probe. Technical note.","volume":"22","author":"Crawford","year":"1997"},{"key":"b5","series-title":"Clin Biomech","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/S0268-0033(98)00080-1","article-title":"A new technique for determining 3-D joint angles: the tilt\/twist method.","volume":"14","author":"Crawford","year":"1999"},{"key":"b6","series-title":"J Neurosurg (Spine 1)","first-page":"51","article-title":"Biomechanics of Grade I degenerative lumbar spondylolisthesis. Part 2: Treatment using threaded interbody cages\/dowels and pedicle screws.","volume":"94","author":"\u00c7agli","year":"2000"},{"key":"b7","series-title":"Spine","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1097\/00007632-198507000-00008","article-title":"Kinematics of the whole lumbar spine. Effect of discectomy.","volume":"10","author":"Goel","year":"1985"},{"key":"b8","series-title":"Spine","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1097\/00007632-198409000-00007","article-title":"Lumbosacral spinal fusion. A biomechanical study.","volume":"9","author":"Lee","year":"1984"},{"key":"b9","series-title":"Semin Spine Surg","first-page":"14","article-title":"Biomechanical considerations for spondylolisthesis.","volume":"11","author":"Lim","year":"1999"},{"key":"b10","series-title":"J Bone Joint Surg (Br)","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1302\/0301-620X.80B2.0800351","article-title":"Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density.","volume":"80","author":"Lund","year":"1998"},{"key":"b11","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1204","DOI":"10.1097\/00007632-199011010-00021","article-title":"Natural history of degenerative spondylolisthesis. Pathogenesis and natural course of the slippage.","volume":"15","author":"Matsunaga","year":"1990"},{"key":"b12","series-title":"J Spinal Disord","first-page":"357","article-title":"Multidirectional stabilizing potential of BAK interbody spinal fusion system for anterior surgery.","volume":"10","author":"Nibu","year":"1997"},{"key":"b13","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1097\/00007632-198810000-00013","article-title":"Biomechanical evaluation of spinal fixation devices: I. A conceptual framework.","volume":"13","author":"Panjabi","year":"1988"},{"key":"b14","series-title":"J Spinal Disord","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1097\/00002517-199212000-00002","article-title":"The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis.","volume":"5","author":"Panjabi","year":"1992"},{"key":"b15","series-title":"J Orthop Res","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1002\/jor.1100030305","article-title":"Biomechanical time-tolerance of fresh cadaveric human spine specimens.","volume":"3","author":"Panjabi","year":"1985"},{"key":"b16","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1007\/s005860050097","article-title":"The role of supplemental translaminar screws in anterior lumbar interbody fixation: A biomechanical study.","volume":"7","author":"Rathonyi","year":"1998"},{"key":"b17","series-title":"J Bone Joint Surg (Am)","doi-asserted-by":"publisher","first-page":"518","DOI":"10.2106\/00004623-199173040-00007","article-title":"Biomechanical evaluation of methods of posterior stabilization of the spine and posterior lumbar interbody arthrodesis for lumbosacral isthmic spondylolisthesis. A calf-spine model.","volume":"73","author":"Shirado","year":"1991"},{"key":"b18","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1097\/00007632-199507000-00003","article-title":"Instability of the lumbar burst fracture and limitations of transpedicular instrumentation.","volume":"20","author":"Slosar","year":"1995"},{"key":"b19","series-title":"Semin Spine Surg","first-page":"2","article-title":"Classification, diagnosis, radiographs, natural history, and conservative treatment of spondylolisthesis.","volume":"11","author":"Southern","year":"1999"},{"key":"b20","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2408","DOI":"10.1097\/00007632-199511001-00007","article-title":"Biomechanical properties of threaded inserts for lumbar interbody spinal fusion.","volume":"20","author":"Tencer","year":"1995"},{"key":"b21","series-title":"J Spinal Disord","first-page":"425","article-title":"Transfacet screws with lumbar interbody reconstruction: biomechanical study of motion segment stiffness.","volume":"9","author":"Volkman","year":"1996"},{"key":"b22","series-title":"Anat Rec","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1002\/(SICI)1097-0185(199805)251:1<15::AID-AR4>3.0.CO;2-D","article-title":"Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular-deformation rate, and moisture condition.","volume":"251","author":"Wilke","year":"1998"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/94\/1\/article-p45.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/94\/1\/article-p45.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/94\/1\/article-p45.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T16:43:06Z","timestamp":1681576986000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/94\/1\/article-p45.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,1]]},"references-count":22,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3171\/spi.2001.94.1.0045","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2001,1]]}}}