{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T09:12:44Z","timestamp":1742634764522},"reference-count":23,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2003,3]]},"abstract":"<jats:p content-type=\"fine-print\"><jats:italic>Object.<\/jats:italic> The purpose of this study was to evaluate the usefulness of a high-porosity hydroxyapatite (HA) spacer in cervical laminoplasty. Bone\u2014spacer bonding rates, complications associated with the implant, and factors related to bone bonding were examined.<\/jats:p>\n<jats:p content-type=\"fine-print\"><jats:italic>Methods.<\/jats:italic> The authors evaluated 33 consecutive patients with cervical myelopathy who underwent high-porosity HA spacer\u2014assisted laminoplasty and were followed for at least 1 year (mean 30 months). The results of bone\u2014spacer bonding of the 147 implants were evaluated using computerized tomography (CT) scanning. The symptoms significantly improved in 30 patients. No difference in results was detected between patients with cervical spondylosis and those with ossification of posterior longitudinal ligament. Breakage of seven spacers occurred in four patients without causing neck pain or neurological deficits. There were no other HA spacer\u2014related complications. The spacers became rigidly bound to bone in 61% of the cases, and bone regrowth developed around the spacer in 91%. The rate of bone\u2014spacer bonding increased over time, and the CT-documented attenuation value (Hounsfield unit) of the spacer adjacent to the bone\u2014spacer junction in the group in which union occurred was significantly higher than in the nonunion group.<\/jats:p>\n<jats:p content-type=\"fine-print\"><jats:italic>Conclusions.<\/jats:italic> High-porosity HA spacer\u2014augmented laminoplasty produced good bonding-related results. Bone bonding continued to progress 1 year after surgery, indicating the good osteoconductive capability of high-porosity HA. To avoid breakage of a spacer, a minimum 7-mm distance between spacers is necessary.<\/jats:p>","DOI":"10.3171\/spi.2003.98.2.0137","type":"journal-article","created":{"date-parts":[[2009,5,7]],"date-time":"2009-05-07T15:59:32Z","timestamp":1241711972000},"page":"137-142","source":"Crossref","is-referenced-by-count":9,"title":["Cervical laminoplasty: evaluation of bone bonding of a high porosity hydroxyapatite spacer"],"prefix":"10.3171","volume":"98","author":[{"given":"Tetsuhiro","family":"Iguchi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aritetsu","family":"Kanemura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Kurihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Kasahara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichi","family":"Yoshiya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Minoru","family":"Doita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kotaro","family":"Nishida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"key":"b1","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1788","DOI":"10.1097\/00007632-200007150-00009","article-title":"T-Saw laminoplasty for the management of cervical spondylotic myelopathy: clinical and radiographic outcome.","volume":"25","author":"Edwards","year":"2000"},{"key":"b2","series-title":"Arch Orthop Trauma","first-page":"203","article-title":"Atrophy of the nuchal muscle and change in cervical curvature after expansive open-door laminoplasty.","volume":"Surg 115","author":"Fujimura","year":"1996"},{"key":"b3","series-title":"J Orthop Sci","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1007\/s007760170013","article-title":"Resorption of synthetic porous hydroxyapatite and replacement by newly formed bone.","volume":"6","author":"Goto","year":"2001"},{"key":"b4","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1097\/00007632-199111000-00005","article-title":"Bilateral open laminoplasty using ceramic laminas for cervical myelopathy.","volume":"16","author":"Hase","year":"1991"},{"key":"b5","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1097\/00007632-200106150-00013","article-title":"Laminoplasty versus laminectomy and fusion for multilevel cervical myelopathy: an independent matched cohort analysis.","volume":"26","author":"Heller","year":"2001"},{"key":"b6","series-title":"Spine","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1097\/00007632-198807000-00011","article-title":"A comparison of anterior cervical fusion, cervical laminectomy, and cervical laminoplasty for the surgical management of multiple level spondylotic radiculopathy.","volume":"13","author":"Herkowitz","year":"1988"},{"key":"b7","series-title":"Spine","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1097\/00007632-198310000-00003","article-title":"Expansive opendoor laminoplasty for cervical spinal stenotic myelopathy.","volume":"8","author":"Hirabayashi","year":"1983"},{"key":"b8","series-title":"J Orthop Sci","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1007\/s007760050102","article-title":"Contact of hydroxyapatite spacers with split spinous processes in double-door laminoplasty for cervical myelopathy.","volume":"4","author":"Hirabayashi","year":"1999"},{"key":"b9","series-title":"Spinal Cord","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1038\/sc.1996.132","article-title":"Expansive cervical laminoplasties\u2014observations on comparative changes in spinous process lengths following longitudinal laminal divisions using autogenous bone or hydroxyapatite spacers.","volume":"34","author":"Hoshi","year":"1996"},{"key":"b10","series-title":"J Japan Spine Res Society","first-page":"215","article-title":"[Bone ingrowth to the hydroxyapatite spacer after spinous process splitting laminoplasty.]","volume":"5","author":"Ichikawa","year":"1994"},{"key":"b11","series-title":"Clin Orthop","first-page":"287","article-title":"Packing with high-porosity hydroxyapatite cubes alone for the treatment of simple bone cyst.","volume":"293","author":"Inoue","year":"1993"},{"key":"b12","series-title":"Nippon Seikeigeka Gakkai Zasshi","first-page":"1033","article-title":"[Roentgenographic studies on the normal pattern of the cervical curvature.]","volume":"42","author":"Ishihara","year":"1968"},{"key":"b13","series-title":"Tohoku J Exp Med","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1620\/tjem.173.337","article-title":"Histological verification of bone bonding and ingrowth into porous hydroxyapatite spinous process spacer for cervical laminoplasty.","volume":"173","author":"Kokubun","year":"1994"},{"key":"b14","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1227\/00006123-199509000-00010","article-title":"Spinous process-splitting laminoplasty with an extended foraminotomy for cervical myelopathy.","volume":"37","author":"Koshu","year":"1995"},{"key":"b15","series-title":"Surg Neurol","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/0090-3019(85)90128-4","article-title":"Cervical laminoplasty using apatite beads as implants. Experience in 31 patients with compressive myelopathy due to developmental canal stenosis.","volume":"24","author":"Koyama","year":"1985"},{"key":"b16","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"64","DOI":"10.3171\/jns.1997.86.1.0064","article-title":"Modified open-door cervical expansive laminoplasty for spondylotic myelopathy: operative technique, outcome, and predictors for gait improvement.","volume":"86","author":"Lee","year":"1997"},{"key":"b17","series-title":"Spine","doi-asserted-by":"publisher","first-page":"S41","DOI":"10.1097\/00007632-199203001-00009","article-title":"Spinous process-splitting laminoplasty using hydroxyapatite spinous process spacer.","volume":"17","author":"Nakano","year":"1992"},{"key":"b18","series-title":"Rinsho Seikei Geka","first-page":"1233","article-title":"[Studies in implantation of the synthetic hydroxyapatite.]","volume":"21","author":"Niwa","year":"1986"},{"key":"b19","series-title":"Biomaterials","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/0142-9612(90)90008-E","article-title":"Quantitative study on osteoconduction of apatite-wollastonite containing glass ceramic granules, hydroxyapatite granules, and alumina granules.","volume":"11","author":"Ono","year":"1990"},{"key":"b20","series-title":"Spine","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1097\/00007632-200103010-00010","article-title":"Long-term results of double-door laminoplasty for cervical stenotic myelopathy.","volume":"26","author":"Seichi","year":"2001"},{"key":"b21","series-title":"J Neurosurg (Spine 1)","doi-asserted-by":"publisher","first-page":"22","DOI":"10.3171\/spi.2002.96.1.0022","article-title":"Bilateral open-door cervical expansive laminoplasty with hydroxyapatite spacers and titanium screws.","volume":"96","author":"Takayasu","year":"2002"},{"key":"b22","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2308","DOI":"10.1097\/00007632-199911150-00004","article-title":"Operative results of canal-expansive laminoplasty for cervical spondylotic myelopathy in elderly patients.","volume":"24","author":"Tanaka","year":"1999"},{"key":"b23","series-title":"Spine","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1097\/00007632-199801010-00007","article-title":"Expansive midline T-saw laminoplasty (modified spinous process-splitting) for the management of cervical myelopathy.","volume":"23","author":"Tomita","year":"1998"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/98\/2\/article-p137.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/98\/2\/article-p137.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/98\/2\/article-p137.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T20:30:20Z","timestamp":1681590620000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/98\/2\/article-p137.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,3]]},"references-count":23,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3171\/spi.2003.98.2.0137","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2003,3]]}}}