{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T01:37:03Z","timestamp":1775871423395,"version":"3.50.1"},"reference-count":16,"publisher":"Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.31744\/einstein_journal\/2018ao4312","type":"journal-article","created":{"date-parts":[[2018,11,28]],"date-time":"2018-11-28T06:23:31Z","timestamp":1543386211000},"source":"Crossref","is-referenced-by-count":8,"title":["Comparative study of transepidermal water loss in patients with and without hyperhidrosis by closed-chamber measurer in an air-conditioned environment"],"prefix":"10.31744","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4260-0595","authenticated-orcid":false,"given":"Andre","family":"Miotto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5113-1663","authenticated-orcid":false,"given":"Pedro Augusto Antunes","family":"Honda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9933-0354","authenticated-orcid":false,"given":"Thiago Gangi","family":"Bachichi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9473-3365","authenticated-orcid":false,"given":"Caio Santos","family":"Holanda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4292-4995","authenticated-orcid":false,"suffix":"Neto","given":"Ernesto","family":"Evangelista","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5958-2541","authenticated-orcid":false,"given":"Jo\u00e3o Alessio Juliano","family":"Perfeito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2323-3547","authenticated-orcid":false,"given":"Luiz Eduardo Villa\u00e7a","family":"Le\u00e3o","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0912-2330","authenticated-orcid":false,"suffix":"Jr","given":"Altair da Silva","family":"Costa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"16942","published-online":{"date-parts":[[2018,10,30]]},"reference":[{"issue":"5","key":"key20181205134737_B1","doi-asserted-by":"crossref","first-page":"657","DOI":"10.4065\/80.5.657","article-title":"Hyperhidrosis: evolving therapies for a well-established phenomenon","volume":"80","author":"Eisenach","year":"2005","journal-title":"Mayo Clin Proc"},{"issue":"5","key":"key20181205134737_B2","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1590\/S1806-37132012000500006","article-title":"Quantitative assessment of the intensity of palmar and plantar sweating in patients with primary palmoplantar hyperhidrosis","volume":"38","author":"Sakiyama","year":"2012","journal-title":"J Bras Pneumol"},{"issue":"6","key":"key20181205134737_B3","first-page":"757","article-title":"Sweating and hyperhidrosis","volume":"276","author":"Clark","year":"2006","journal-title":"Pharmacol J"},{"issue":"1","key":"key20181205134737_B4","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1111\/j.1600-0846.2008.00334.x","article-title":"Comparison of closed chamber and open chamber evaporimetry","volume":"15","author":"Cohen","year":"2009","journal-title":"Skin Res Technol"},{"issue":"2","key":"key20181205134737_B5","doi-asserted-by":"crossref","first-page":"101","DOI":"10.6061\/clinics\/2014(02)05","article-title":"Randomized trial - oxybutynin for treatment of persistent plantar hyperhidrosis in women after sympathectomy","volume":"69","author":"Costa","year":"2014","journal-title":"Clinics"},{"issue":"1","key":"key20181205134737_B6","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1111\/j.1600-0846.2005.00101.x","article-title":"Validation of the VapoMeter, a closed unventilated chamber system to assess transepidermal water loss vs. the open chamber Tewameter","volume":"11","author":"De Paepe","year":"2005","journal-title":"Skin Res Technol"},{"issue":"4","key":"key20181205134737_B7","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1510\/icvts.2010.252015","article-title":"Objective evaluation of patients with palmar hyperhidrosis submitted to two levels of sympathectomy: T3 and T4","volume":"12","author":"Ishy","year":"2011","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"2","key":"key20181205134737_B8","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1034\/j.1600-0846.2003.00025.x","article-title":"A closed unventilated chamber for the measurement of transepidermal water loss","volume":"9","author":"Nuutinen","year":"2003","journal-title":"Skin Res Technol"},{"issue":"5","key":"key20181205134737_B9","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1177\/1090820X11410869","article-title":"Definitive diagnosis and management of axillary hyperhidrosis: the VapoMeter and suction-assisted arthroscopic shaving","volume":"31","author":"Larson","year":"2011","journal-title":"Aesthet Surg J"},{"issue":"3","key":"key20181205134737_B10","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1111\/j.1600-0846.2011.00509.x","article-title":"Side-by-side comparison of an open-chamber (TM 300) and a closed-chamber (Vapometer\u00ae) transepidermal water loss meter","volume":"17","author":"Steiner","year":"2011","journal-title":"Skin Res Technol"},{"issue":"3","key":"key20181205134737_B11","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1111\/srt.12043","article-title":"Climate and skin function: an overview","volume":"19","author":"Singh","year":"2013","journal-title":"Skin Res Technol"},{"issue":"5","key":"key20181205134737_B12","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1590\/S1516-31802003000500003","article-title":"Role of video-assisted thoracoscopic sympathectomy in the treatment of primary hyperhidrosis","volume":"121","author":"Le\u00e3o","year":"2003","journal-title":"S\u00e3o Paulo Med J"},{"issue":"11","key":"key20181205134737_B13","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1590\/S1806-37132008001100013","article-title":"Guidelines for the prevention, diagnosis and treatment of compensatory hyperhidrosis","volume":"34","author":"Lyra","year":"2008","journal-title":"J Bras Pneumol"},{"issue":"3","key":"key20181205134737_B14","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1111\/srt.12037","article-title":"International guidelines for the in vivo assessment of skin properties in non-clinical settings: Part 2. transepidermal water loss and skin hydration","volume":"19","author":"du Plessis","year":"2013","journal-title":"Skin Res Technol"},{"issue":"45","key":"key20181205134737_B15","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000008611","article-title":"Diabetic and sympathetic influences on the water permeability barrier function of human skin as measured using transepidermal water loss: a case-control study","volume":"96","author":"Han","year":"2017","journal-title":"Medicine"},{"issue":"10","key":"key20181205134737_B16","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1001\/archderm.1995.01690220040008","article-title":"Skin type, but neither race nor gender, influence epidermal permeability barrier function","volume":"131","author":"Reed","year":"1995","journal-title":"Arch Dermatol"}],"container-title":["Einstein (S\u00e3o Paulo)"],"original-title":[],"language":"en","deposited":{"date-parts":[[2018,12,5]],"date-time":"2018-12-05T13:47:50Z","timestamp":1544017670000},"score":1,"resource":{"primary":{"URL":"https:\/\/journal.einstein.br\/pt-br\/article\/estudo-comparativo-da-perda-transepidermica-de-agua-em-pacientes-com-e-sem-hiperidrose-por-mensurador-de-camara-fechada-em-ambiente-climatizado\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"references-count":16,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2018,10,30]]},"published-print":{"date-parts":[[2018]]}},"alternative-id":["10.31744\/einstein_journal\/2018AO4312"],"URL":"https:\/\/doi.org\/10.31744\/einstein_journal\/2018ao4312","relation":{},"ISSN":["1679-4508","2317-6385"],"issn-type":[{"value":"1679-4508","type":"print"},{"value":"2317-6385","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018]]},"article-number":"eAO4312"}}