{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T15:40:40Z","timestamp":1753890040497,"version":"3.41.2"},"reference-count":16,"publisher":"Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,3,14]]},"DOI":"10.31744\/einstein_journal\/2024ce0910","type":"journal-article","created":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T13:54:40Z","timestamp":1710510880000},"source":"Crossref","is-referenced-by-count":0,"title":["Ringing a bell in healthcare: harnessing benefits, overcoming implementation challenges, and bridging knowledge gaps of Closed-Loop Oxygen Control systems (CLOCs)"],"prefix":"10.31744","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9493-0150","authenticated-orcid":false,"given":"Caroline Gomes","family":"M\u00f3l","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6048-716X","authenticated-orcid":false,"given":"Al\u00e9xia Gabriela da Silva","family":"Vieira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8241-3241","authenticated-orcid":false,"given":"Raquel Afonso Caserta","family":"Eid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1520-9387","authenticated-orcid":false,"suffix":"Neto","given":"Ary","family":"Serpa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3969-7792","authenticated-orcid":false,"given":"Marcus J.","family":"Schultz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0852-7013","authenticated-orcid":false,"given":"Ricardo Kenji","family":"Nawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"16942","reference":[{"key":"key20240315095435_B1","author":"World Health Organization (WHO)","year":"2023","unstructured":"1. World Health Organization (WHO). WHO Model List of Essential Medicines - 23rd list, 2023. Geneva: WHO; 2023 [cited 2023 Sep 28]. Available from: https:\/\/www.who.int\/publications\/i\/item\/WHO-MHP-HPS-EML-2023.02","journal-title":"WHO Model List of Essential Medicines - 23rd list, 2023"},{"issue":"6","key":"key20240315095435_B2","doi-asserted-by":"crossref","first-page":"R156","DOI":"10.1186\/cc7150","article-title":"Association between administered oxygen, arterial partial oxygen pressure and mortality in mechanically ventilated intensive care unit patients","volume":"12","author":"de Jonge","year":"2008","unstructured":"2. de Jonge E, Peelen L, Keijzers PJ, Joore H, de Lange D, van der Voort PH, et al. Association between administered oxygen, arterial partial oxygen pressure and mortality in mechanically ventilated intensive care unit patients. Crit Care. 2008;12(6):R156.","journal-title":"Crit Care"},{"issue":"2","key":"key20240315095435_B3","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1097\/CCM.0000000000002084","article-title":"Metrics of Arterial Hyperoxia and Associated Outcomes in Critical Care","volume":"45","author":"Helmerhorst","year":"2017","unstructured":"3. Helmerhorst HJ, Arts DL, Schultz MJ, van der Voort PH, Abu-Hanna A, de Jonge E, et al. Metrics of Arterial Hyperoxia and Associated Outcomes in Critical Care. Crit Care Med. 2017;45(2):187-95.","journal-title":"Crit Care Med"},{"issue":"Suppl 1","key":"key20240315095435_B4","doi-asserted-by":"crossref","first-page":"ii1","DOI":"10.1136\/thoraxjnl-2016-209729","article-title":"BTS guideline for oxygen use in adults in healthcare and emergency settings","volume":"72","author":"O\u2019Driscoll","year":"2017","unstructured":"4. O\u2019Driscoll BR, Howard LS, Earis J, Mak V; British Thoracic Society Emergency Oxygen Guideline Group; BTS Emergency Oxygen Guideline Development Group. BTS guideline for oxygen use in adults in healthcare and emergency settings. Thorax. 2017;72(Suppl 1):ii1-ii90. Review.","journal-title":"Thorax"},{"issue":"19","key":"key20240315095435_B5","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1056\/NEJMoa2208415","article-title":"Oxygen-Saturation Targets for Critically Ill Adults Receiving Mechanical Ventilation","volume":"387","author":"Semler","year":"2022","unstructured":"5. Semler MW, Casey JD, Lloyd BD, Hastings PG, Hays MA, Stollings JL, Buell KG, Brems JH, Qian ET, Seitz KP, Wang L, Lindsell CJ, Freundlich RE, Wanderer JP, Han JH, Bernard GR, Self WH, Rice TW; PILOT Investigators and the Pragmatic Critical Care Research Group. Oxygen-Saturation Targets for Critically Ill Adults Receiving Mechanical Ventilation. N Engl J Med. 2022;387(19):1759-69.","journal-title":"N Engl J Med"},{"issue":"2","key":"key20240315095435_B6","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1159\/000499119","article-title":"Automatic versus Manual Oxygen Titration in Patients Requiring Supplemental Oxygen in the Hospital: a Systematic Review and Meta-Analysis","volume":"98","author":"Denault","year":"2019","unstructured":"6. Denault MH, P\u00e9loquin F, Lajoie AC, Lacasse Y. Automatic versus Manual Oxygen Titration in Patients Requiring Supplemental Oxygen in the Hospital: a Systematic Review and Meta-Analysis. Respiration. 2019;98(2):178-88.","journal-title":"Respiration"},{"key":"key20240315095435_B7","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.cmpb.2017.05.013","article-title":"Physiological closed-loop control in intelligent oxygen therapy: a review","volume":"146","author":"Sanchez-Morillo","year":"2017","unstructured":"7. Sanchez-Morillo D, Olaby O, Fernandez-Granero MA, Leon-Jimenez A. Physiological closed-loop control in intelligent oxygen therapy: a review. Comput Methods Programs Biomed. 2017;146:101-08. Review.","journal-title":"Comput Methods Programs Biomed"},{"issue":"1","key":"key20240315095435_B8","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1001\/jamapediatrics.2018.3619","article-title":"Association of Nurse Workload With Missed Nursing Care in the Neonatal Intensive Care Unit","volume":"173","author":"Tubbs-Cooley","year":"2019","unstructured":"8. Tubbs-Cooley HL, Mara CA, Carle AC, Mark BA, Pickler RH. Association of Nurse Workload With Missed Nursing Care in the Neonatal Intensive Care Unit. JAMA Pediatr. 2019;173(1):44-51.","journal-title":"JAMA Pediatr"},{"issue":"5","key":"key20240315095435_B9","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1007\/s10877-018-0219-z","article-title":"Applying machine learning to continuously monitored physiological data","volume":"33","author":"Rush","year":"2019","unstructured":"9. Rush B, Celi LA, Stone DJ. Applying machine learning to continuously monitored physiological data. J Clin Monit Comput. 2019;33(5):887-93. Review.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"key20240315095435_B10","doi-asserted-by":"crossref","first-page":"2000182","DOI":"10.1183\/13993003.00182-2020","article-title":"Automated closed-loop versus standard manual oxygen administration after major abdominal or thoracic surgery: an international multicentre randomised controlled study","volume":"57","author":"L\u2019Her","year":"2021","unstructured":"10. L\u2019Her E, Jaber S, Verzilli D, Jacob C, Huiban B, Futier E, et al. Automated closed-loop versus standard manual oxygen administration after major abdominal or thoracic surgery: an international multicentre randomised controlled study. Eur Respir J. 2021;57(1):2000182.","journal-title":"Eur Respir J"},{"key":"key20240315095435_B11","doi-asserted-by":"crossref","first-page":"3997","DOI":"10.2147\/COPD.S183762","article-title":"Automated oxygen control with O2matic\u00ae during admission with exacerbation of COPD","volume":"13","author":"Hansen","year":"2018","unstructured":"11. Hansen EF, Hove JD, Bech CS, Jensen JS, Kallemose T, Vestbo J. Automated oxygen control with O2matic\u00ae during admission with exacerbation of COPD. Int J Chron Obstruct Pulmon Dis. 2018;13:3997-4003.","journal-title":"Int J Chron Obstruct Pulmon Dis"},{"issue":"1","key":"key20240315095435_B12","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-022-03970-w","article-title":"Closed-loop oxygen control improves oxygen therapy in acute hypoxemic respiratory failure patients under high flow nasal oxygen: a randomized cross-over study (the HILOOP study)","volume":"26","author":"Roca","year":"2022","unstructured":"12. Roca O, Caritg O, Santaf\u00e9 M, Ramos FJ, Pacheco A, Garc\u00eda-de-Acilu M, et al. Closed-loop oxygen control improves oxygen therapy in acute hypoxemic respiratory failure patients under high flow nasal oxygen: a randomized cross-over study (the HILOOP study). Crit Care. 2022;26(1):108.","journal-title":"Crit Care"},{"issue":"1","key":"key20240315095435_B13","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2017-018835","article-title":"Cost-effectiveness of FreeO2 in patients with chronic obstructive pulmonary disease hospitalised for acute exacerbations: analysis of a pilot study in Quebec","volume":"8","author":"Poder","year":"2018","unstructured":"13. Poder TG, Kouakou CR, Bouchard PA, Tremblay V, Blais S, Maltais F, et al. Cost-effectiveness of FreeO2 in patients with chronic obstructive pulmonary disease hospitalised for acute exacerbations: analysis of a pilot study in Quebec. BMJ Open. 2018;8(1):e018835.","journal-title":"BMJ Open"},{"issue":"10277","key":"key20240315095435_B14","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/S0140-6736(21)00561-4","article-title":"Medical oxygen crisis: a belated COVID-19 response","volume":"397","author":"Usher","year":"2021","unstructured":"14. Usher AD. Medical oxygen crisis: a belated COVID-19 response. Lancet. 2021;397(10277):868-9.","journal-title":"Lancet"},{"issue":"5","key":"key20240315095435_B15","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.4269\/ajtmh.22-0793","article-title":"Oxygen Consumption with High-Flow Nasal Oxygen versus Mechanical Ventilation- An International Multicenter Observational Study in COVID-19 Patients (PROXY-COVID)","volume":"108","author":"Botta","year":"2023","unstructured":"15. Botta M, Caritg O, van Meenen DM, Pacheco A, Tsonas AM, Mooij WE, et al. Oxygen Consumption with High-Flow Nasal Oxygen versus Mechanical Ventilation- An International Multicenter Observational Study in COVID-19 Patients (PROXY-COVID). Am J Trop Med Hyg. 2023;108(5):1035-41.","journal-title":"Am J Trop Med Hyg"},{"issue":"1","key":"key20240315095435_B16","article-title":"Automatic versus manual oxygen titration using a novel nasal high-flow device in medical inpatients with an acute illness: a randomised controlled trial","volume":"8","author":"Harper","year":"2021","unstructured":"16. Harper J, Kearns N, Bird G, Braithwaite I, Eathorne A, Shortt N, et al. Automatic versus manual oxygen titration using a novel nasal high-flow device in medical inpatients with an acute illness: a randomised controlled trial. BMJ Open Respir Res. 2021;8(1):e000843.","journal-title":"BMJ Open Respir Res"}],"container-title":["einstein (S\u00e3o Paulo)"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T13:54:51Z","timestamp":1710510891000},"score":1,"resource":{"primary":{"URL":"https:\/\/journal.einstein.br\/article\/ringing-a-bell-in-healthcare-harnessing-benefits-overcoming-implementation-challenges-and-bridging-knowledge-gaps-of-closed-loop-oxygen-control-systems-clocs\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":16,"alternative-id":["10.31744\/einstein_journal\/2024CE0910"],"URL":"https:\/\/doi.org\/10.31744\/einstein_journal\/2024ce0910","relation":{},"ISSN":["1679-4508","2317-6385"],"issn-type":[{"type":"print","value":"1679-4508"},{"type":"electronic","value":"2317-6385"}],"subject":[],"published":{"date-parts":[[2024]]},"article-number":"eCE0910"}}