{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T14:25:19Z","timestamp":1777472719157,"version":"3.51.4"},"reference-count":29,"publisher":"European Society of Computational Methods in Sciences and Engineering","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"published-print":{"date-parts":[[2022,1,26]]},"abstract":"<jats:p>At present, the main way for electric power companies to check the accuracy of electric meters is that professionals regularly bring standard electric meters to the site for verification. With the widespread application of smart meters and the development of data processing technology, remote error estimation based on the operating data of smart meters becomes possible. In this paper, an error estimation method of smart meter based on clustering and adaptive gradient descent method is proposed. Firstly, the fuzzy c-means clustering method is used to preprocess the data to classify the operating conditions of each measurement, and then the adaptive gradient descent method is used to establish the error estimation model. The simulation results show that this method has high error estimation accuracy. This method has a small amount of calculation and high reliability and is suitable for large-scale power grids.<\/jats:p>","DOI":"10.3233\/jcm-215901","type":"journal-article","created":{"date-parts":[[2021,12,21]],"date-time":"2021-12-21T12:58:27Z","timestamp":1640091507000},"page":"207-217","source":"Crossref","is-referenced-by-count":5,"title":["Remote error estimation of smart meter based on clustering and adaptive gradient descent method"],"prefix":"10.66113","volume":"22","author":[{"given":"Liang","family":"Chen","sequence":"first","affiliation":[{"name":"Meteorology Center of Guangdong Power Grid Co. Ltd., Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youpeng","family":"Huang","sequence":"additional","affiliation":[{"name":"Meteorology Center of Guangdong Power Grid Co. Ltd., Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Lu","sequence":"additional","affiliation":[{"name":"Meteorology Center of Guangdong Power Grid Co. Ltd., Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanlei","family":"Dang","sequence":"additional","affiliation":[{"name":"Meteorology Center of Guangdong Power Grid Co. Ltd., Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Zhang","sequence":"additional","affiliation":[{"name":"Meteorology Center of Guangdong Power Grid Co. Ltd., Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wen","family":"Zhao","sequence":"additional","affiliation":[{"name":"Meteorology Center of Guangdong Power Grid Co. Ltd., Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhengmin","family":"Kong","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Automation, Wuhan University, Wuhan, Hubei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"55691","reference":[{"key":"10.3233\/JCM-215901_ref1","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.solener.2018.01.070","article-title":"Monitoring and assessment of pv generation based on a combination of smart metering and thermographic measurement","volume":"163","author":"Stegner","year":"2018","journal-title":"Solar Energy."},{"key":"10.3233\/JCM-215901_ref2","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.enbuild.2017.09.056","article-title":"Mining electrical meter data to predict principal building use, performance class, and operations strategy for hundreds of non-residential buildings","volume":"156","author":"Miller","year":"2017","journal-title":"Energy and Buildings."},{"key":"10.3233\/JCM-215901_ref3","doi-asserted-by":"crossref","unstructured":"Wang Y, Qiu H, Tu Y, Liu Q, Ding Y, Wang W. A review of smart metering for future chinese grids. Energy Procedia. 2018; 152: 1194-1199.","DOI":"10.1016\/j.egypro.2018.09.158"},{"issue":"3","key":"10.3233\/JCM-215901_ref4","doi-asserted-by":"crossref","first-page":"3125","DOI":"10.1109\/TSG.2018.2818167","article-title":"Review of smart meter data analytics: Applications, methodologies, and challenges","volume":"10","author":"Wang","year":"2018","journal-title":"IEEE Transactions on Smart Grid."},{"issue":"4","key":"10.3233\/JCM-215901_ref5","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1109\/MCOM.2017.1600210C","article-title":"Graph-based cyber security analysis of state estimation in smart power grid","volume":"55","author":"Bi","year":"2017","journal-title":"IEEE Communications Magazine."},{"issue":"5","key":"10.3233\/JCM-215901_ref6","first-page":"162","article-title":"Design of big data analytics electricity collecting data analysis and intelligent monitoring systems","author":"Yu","year":"2017","journal-title":"Automation & Instrumentation."},{"key":"10.3233\/JCM-215901_ref7","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1016\/j.apenergy.2016.09.087","article-title":"Measuring the energy intensity of domestic activities from smart meter data","volume":"183","author":"Stankovic","year":"2016","journal-title":"Applied Energy."},{"issue":"1","key":"10.3233\/JCM-215901_ref8","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1109\/TPWRD.2016.2580663","article-title":"A generic waveform abnormality detection method for utility equipment condition monitoring","volume":"32","author":"Li","year":"2016","journal-title":"IEEE Transactions on Power Delivery."},{"key":"10.3233\/JCM-215901_ref9","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1016\/j.rser.2017.05.134","article-title":"Big data issues in smart grid \u2013 a review","volume":"79","author":"Tu","year":"2017","journal-title":"Renewable and Sustainable Energy Reviews."},{"key":"10.3233\/JCM-215901_ref10","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.epsr.2017.06.006","article-title":"Big data framework for analytics in smart grids","volume":"151","author":"Munshi","year":"2017","journal-title":"Electric Power Systems Research."},{"issue":"4","key":"10.3233\/JCM-215901_ref11","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1109\/TPWRD.2019.2912267","article-title":"Data-driven condition monitoring of data acquisition for consumers\u2019 transformers in actual distribution systems using t-statistics","volume":"34","author":"Liu","year":"2019","journal-title":"IEEE Transactions on Power Delivery."},{"issue":"9","key":"10.3233\/JCM-215901_ref12","doi-asserted-by":"crossref","first-page":"1592","DOI":"10.1016\/j.measurement.2011.06.024","article-title":"Autonomous algorithm for relative error of generalized flow meters in tree topology","volume":"44","author":"Guo","year":"2011","journal-title":"Measurement."},{"key":"10.3233\/JCM-215901_ref13","first-page":"174","article-title":"General model of security region and its application in energy meters\u2019 status estimation","volume":"7","author":"Cheng","year":"2016","journal-title":"Electronic Measurement Technology."},{"key":"10.3233\/JCM-215901_ref15","first-page":"110","article-title":"Remote error self-diagnosis of metering fault and power stealing identification","volume":"23","author":"Jiang","year":"2019","journal-title":"Electronics World."},{"key":"10.3233\/JCM-215901_ref16","first-page":"46","article-title":"Exploration and practice of remote error calculation of energy meter based on low voltage station area","volume":"33","author":"Liu","year":"2018","journal-title":"Technology Innovation and Application."},{"issue":"3","key":"10.3233\/JCM-215901_ref17","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1109\/TCPMT.2015.2500023","article-title":"A novel intermittent fault detection algorithm and health monitoring for electronic interconnections","volume":"6","author":"Syed","year":"2016","journal-title":"IEEE Transactions on Components, Packaging and Manufacturing Technology."},{"issue":"2","key":"10.3233\/JCM-215901_ref18","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1049\/hve.2017.0026","article-title":"Condition monitoring and diagnosis of power equipment: review and prospective","volume":"2","author":"Li","year":"2017","journal-title":"High Voltage."},{"issue":"5","key":"10.3233\/JCM-215901_ref19","doi-asserted-by":"crossref","first-page":"805","DOI":"10.3390\/en12050805","article-title":"A recursive least squares method with double-parameter for online estimation of electric meter errors","volume":"12","author":"Kong","year":"2019","journal-title":"Energies."},{"issue":"1","key":"10.3233\/JCM-215901_ref20","doi-asserted-by":"crossref","first-page":"37","DOI":"10.3390\/en12010037","article-title":"An analysis of the systematic error of a remote method for a wattmeter adjustment gain estimation in smart grids","volume":"12","author":"Lukocius","year":"2019","journal-title":"Energies."},{"key":"10.3233\/JCM-215901_ref21","doi-asserted-by":"crossref","first-page":"105536","DOI":"10.1016\/j.ijepes.2019.105536","article-title":"Error performance analysis and modeling of narrow-band plc technology enabling smart metering systems","volume":"116","author":"Borovina","year":"2020","journal-title":"International Journal of Electrical Power & Energy Systems."},{"issue":"10","key":"10.3233\/JCM-215901_ref22","doi-asserted-by":"crossref","first-page":"2514","DOI":"10.3390\/en11102514","article-title":"Data-driven risk analysis for probabilistic three-phase grid-supportive demand side management","volume":"11","author":"Blaauwbroek","year":"2018","journal-title":"Energies."},{"issue":"3","key":"10.3233\/JCM-215901_ref23","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1109\/TIM.2018.2857118","article-title":"A method for remote estimation of wattmeter\u2019 s adjustment gain","volume":"68","author":"Nakutis","year":"2018","journal-title":"IEEE Transactions on Instrumentation and Measurement."},{"key":"10.3233\/JCM-215901_ref24","unstructured":"Kong X, Ma Y, Li Y, Wang C, Zhao X. Remote estimation for measurement error of smart meter based on limited memory recursive least squares algorithm. Proceedings of the CSEE. 2020; 40(7): 2143-2151."},{"issue":"16","key":"10.3233\/JCM-215901_ref27","first-page":"142","article-title":"A method for remote calibration and large-scale verification of electric energy meter","volume":"56","author":"Yang","year":"2019","journal-title":"Electrical Measurement & Instrumentation."},{"key":"10.3233\/JCM-215901_ref28","doi-asserted-by":"crossref","first-page":"165","DOI":"10.4028\/www.scientific.net\/KEM.419-420.165","article-title":"An outlier detection method based on fuzzy c-means clustering","volume":"419\u2013420","author":"Li","year":"2009","journal-title":"Key Engineering Materials."},{"issue":"1","key":"10.3233\/JCM-215901_ref30","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1109\/TFUZZ.2010.2087382","article-title":"A kernel fuzzy c-means clustering-based fuzzy support vector machine algorithm for classification problems with outliers or noises","volume":"19","author":"Yang","year":"2010","journal-title":"IEEE Transactions on Fuzzy Systems."},{"issue":"9","key":"10.3233\/JCM-215901_ref32","first-page":"90","article-title":"Load data identification and repair method based on improved fuzzy c-means clustering","volume":"41","author":"Kong","year":"2017","journal-title":"Automation of Electric Power Systems."},{"key":"10.3233\/JCM-215901_ref33","unstructured":"Li Y, Liu L, Li B. Calculation method of station line loss rate based on improved k-means clustering and bp neural network. Proceedings of the CSEE. 2016; 36(17): 4543-4551."},{"issue":"7","key":"10.3233\/JCM-215901_ref34","first-page":"2121","article-title":"Adaptive subgradient methods for online learning and stochastic optimization","volume":"12","author":"Duchi","year":"2011","journal-title":"Journal of machine learning research."}],"container-title":["Journal of Computational Methods in Sciences and Engineering"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/JCM-215901","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:06:33Z","timestamp":1776809193000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/JCM-215901"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,26]]},"references-count":29,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3233\/jcm-215901","relation":{},"ISSN":["1472-7978","1875-8983"],"issn-type":[{"value":"1472-7978","type":"print"},{"value":"1875-8983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,26]]}}}