{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:48:44Z","timestamp":1776811724314,"version":"3.51.2"},"reference-count":17,"publisher":"European Society of Computational Methods in Sciences and Engineering","issue":"4","license":[{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Computational Methods in Sciences and Engineering"],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:p>Steady-state calculation and analysis are often inconsistent with actual conditions, because buildings are usually in unsteady heat transfer conditions; however, studies on heat transfer in the unsteady state usually adopt experiments and simulations, which do not allow consecutive analysis corresponding with the changes of the independent variable of construction. Therefore, the solution to the equation of heat transfer in the unsteady state is of great importance to the consecutive analysis of heat transfer condition in the unsteady state. Adopting the methods of both convolution calculation analysis of heat transfer in the unsteady state and experiments, the researchers ranked the four types of construction insulation performances of non-transparent enclosures of subtropical buildings in summer, including external thermal insulation, self-insulation, and two type of internal thermal insulation due to the change in the thickness of the insulation layer. As a result, the maximum value of indoor temperature in the actual condition is different from the one from the calculation of the steady steady-state but consistent with the one from convolution analysis of the unsteady state. Both the actual situation and the results of unsteady convolution calculation prove that we should not hastily draw the conclusion as to the \u201cwinner\u201d between \u201cinner heat preservation\u201d and \u201couter heat preservation\u201d. The unsteady convolution calculation enables us to better conduct a continuous and quantitative description and prediction of the insulation performance of the constructions in the working condition and their ranking along with the changes of construction layer.<\/jats:p>","DOI":"10.3233\/jcm-226766","type":"journal-article","created":{"date-parts":[[2023,5,12]],"date-time":"2023-05-12T13:40:56Z","timestamp":1683898856000},"page":"2127-2140","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["A descriptive study on the convolution analysis of the insulation performance of non-transparent enclosures corresponding with the changes of the construction hierarchy"],"prefix":"10.66113","volume":"23","author":[{"given":"Shuo","family":"Wang","sequence":"first","affiliation":[{"name":"Key Laboratory of Disaster Forecast and Control in Engineering, Jinan University, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huisheng","family":"Zeng","sequence":"additional","affiliation":[{"name":"Key Laboratory of Disaster Forecast and Control in Engineering, Jinan University, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Tang","sequence":"additional","affiliation":[{"name":"Key Laboratory of Disaster Forecast and Control in Engineering, Jinan University, Guangzhou, Guangdong, China"},{"name":"Guangdong University of Finance &amp; Economics, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenchen","family":"Wang","sequence":"additional","affiliation":[{"name":"Key Laboratory of Disaster Forecast and Control in Engineering, Jinan University, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lan","family":"Wang","sequence":"additional","affiliation":[{"name":"Key Laboratory of Disaster Forecast and Control in Engineering, Jinan University, Guangzhou, Guangdong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"55691","published-online":{"date-parts":[[2023,7]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.6110\/kjacr.2015.27.12.633"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6701(06)82240-x"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1080\/01430750.2021.1994463"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","unstructured":"FengG ShaS XuX. Analysis of the building envelope influence to building energy consumption in the cold regions. Procedia Engineering. 2016; 146: 244-250. doi: 10.1016\/j.proeng.2016.06.382.","DOI":"10.1016\/j.proeng.2016.06.382"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","unstructured":"YinF LinZ KongQ et al. FedLoc: Federated learning framework for data-driven cooperative localization and location data processing. IEEE Open Journal of Signal Processing. 2020; 1: 187-215. doi: 10.1109\/ojsp.2020.3036276.","DOI":"10.1109\/ojsp.2020.3036276"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/jsac.2019.2904330"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3130\/aije.78.929"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3130\/jaabe.17.159"},{"key":"e_1_3_2_10_2","first-page":"13","article-title":"Heat load calculations by thermal response factors","volume":"62","author":"Brisken WR","year":"1956","unstructured":"BriskenWR RequeSG. Heat load calculations by thermal response factors. ASHVE Transactions. 1956; 62: 13-17.","journal-title":"ASHVE Transactions."},{"issue":"2","key":"e_1_3_2_11_2","first-page":"117","article-title":"cooling load calculation by thermal response factor method","volume":"79","author":"Stephenson DG","year":"1973","unstructured":"StephensonDG MitalasGP. cooling load calculation by thermal response factor method. ASHVE Transactions. 1973; 79(2): 117-126.","journal-title":"ASHVE Transactions."},{"key":"e_1_3_2_12_2","article-title":"Comments on the z-transfer function method for calculating heat transfer in buildings","author":"Mitalas GP","year":"1978","unstructured":"MitalasGP. Comments on the z-transfer function method for calculating heat transfer in buildings. ASHRAE Transactions, Part 1; 1978.","journal-title":"ASHRAE Transactions, Part 1"},{"key":"e_1_3_2_13_2","unstructured":"StamperMB. Proceedings of the Conference of the Thermal Performance of the Exterior Envelopes of Buildings. Annual Cycle Moisture Analysis. 1979; FL pp. 3-5."},{"issue":"2","key":"e_1_3_2_14_2","first-page":"44","article-title":"A new method for calculating the heat transfer reaction coefficients of multilayer walls \u2013 State space method","author":"Ouyang K","year":"1989","unstructured":"OuyangK. A new method for calculating the heat transfer reaction coefficients of multilayer walls \u2013 State space method. Building Science. 1989; (2): 44-48.","journal-title":"Building Science."},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3846\/13923730.2006.9636379"},{"key":"e_1_3_2_16_2","first-page":"82","article-title":"A convolution analysis and comparison of the insulation performance in the unsteady state of subtropical oyster shell wall and non-transparent enclosures","volume":"128","author":"Wang S","year":"2021","unstructured":"WangS TangJ WangCC ChenX. A convolution analysis and comparison of the insulation performance in the unsteady state of subtropical oyster shell wall and non-transparent enclosures. Basic & Clinical Pharmacology & Toxicology. 2021; 128: 82-83.","journal-title":"Basic & Clinical Pharmacology & Toxicology."},{"key":"e_1_3_2_17_2","unstructured":"DingLK TangJ. Comparative analysis of monetary and energy dimension methods in calculating the payback period of photovoltaic (PV) curtain wall Energy Education Science and Technology Part A: Energy Science and Research. 2014; 32(5): 3269-3276."},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.14257\/ijmue.2016.11.4.27"}],"container-title":["Journal of Computational Methods in Sciences and Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JCM-226766","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.3233\/JCM-226766","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JCM-226766","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:06:59Z","timestamp":1776809219000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.3233\/JCM-226766"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,7]]}},"alternative-id":["10.3233\/JCM-226766"],"URL":"https:\/\/doi.org\/10.3233\/jcm-226766","relation":{},"ISSN":["1472-7978","1875-8983"],"issn-type":[{"value":"1472-7978","type":"print"},{"value":"1875-8983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7]]}}}