{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:49:30Z","timestamp":1776811770268,"version":"3.51.2"},"reference-count":26,"publisher":"European Society of Computational Methods in Sciences and Engineering","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"published-print":{"date-parts":[[2023,12,15]]},"abstract":"<jats:p>The heat source tower heat pump system is widely used in large and medium-sized air conditioning systems due to its good energy-saving advantages. However, there is no relatively reasonable evaluation system for the applicability of heat source tower heat pumps due to significant regional climate differences. Therefore, in order to better comprehensively evaluate the applicability of the heat source tower heat pump system, a comprehensive evaluation index system for the applicability of the heat source tower heat pump system was first constructed. On the basis of this evaluation index, an applicability evaluation model based on backpropagation neural network is constructed. In response to the slow convergence speed and susceptibility to local values in the application process of this evaluation model, particle swarm optimization algorithm is used to improve it. A comprehensive evaluation model for the applicability of heat source tower heat pumps based on improved backpropagation neural networks has been constructed. For the evaluation model constructed in the study, experimental data from four different regions were selected for validation. The experimental results show that in the training set, the F-Measure value of the evaluation model reaches 0.949, and in the test set, the F-Measure value of the model reaches 0.973. The comprehensive evaluation data from four regions indicate that the heat source tower heat pump system can achieve different heating and cooling effects in different regions. This indicates that the proposed comprehensive evaluation model for the applicability of heat source tower heat pumps based on this improved method has good evaluation results. It can conduct a good analysis of the applicability of the heat source tower heat pump system, providing effective support for developing reasonable and energy-saving refrigeration and heating methods in different regions.<\/jats:p>","DOI":"10.3233\/jcm-226957","type":"journal-article","created":{"date-parts":[[2023,12,19]],"date-time":"2023-12-19T12:23:13Z","timestamp":1702988593000},"page":"2879-2892","source":"Crossref","is-referenced-by-count":0,"title":["A comprehensive evaluation method of heat source tower heat pump applicability considering regional climate differences"],"prefix":"10.66113","volume":"23","author":[{"given":"Hongyin","family":"Chen","sequence":"first","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Songcen","family":"Wang","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming","family":"Zhong","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lu","family":"Jin","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoqiang","family":"Jia","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Guo","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinhe","family":"Zhang","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Huang","sequence":"additional","affiliation":[{"name":"National Key Laboratory of Power Grid Safety, Beijing, China"},{"name":"China Electric Power Research Institute Co., Ltd., Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"55691","reference":[{"key":"10.3233\/JCM-226957_ref1","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.renene.2021.10.009","article-title":"Rational assessment and selection of air source heat pump system operating with CO2 and R407C for electric bus","volume":"182","author":"Wang","year":"2022","journal-title":"Renew Energ."},{"key":"10.3233\/JCM-226957_ref2","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.energy.2019.02.061","article-title":"Performance and feasibility study of hybrid ground source heat pump system assisted with cooling tower for one office building based on one Shanghai case","volume":"173","author":"Liu","year":"2019","journal-title":"Energy."},{"key":"10.3233\/JCM-226957_ref3","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1016\/j.solener.2021.06.046","article-title":"Performance evaluation of off-grid solar chemical heat pump for cooling\/heating","volume":"224","author":"Ren","year":"2021","journal-title":"Sol Energy."},{"issue":"17","key":"10.3233\/JCM-226957_ref4","doi-asserted-by":"crossref","first-page":"2990","DOI":"10.1049\/iet-com.2020.0368","article-title":"Distributed resource allocation optimisation algorithm based on particle swarm optimisation in wireless sensor network","volume":"14","author":"Hao","year":"2020","journal-title":"IET Commun."},{"key":"10.3233\/JCM-226957_ref5","doi-asserted-by":"crossref","first-page":"632","DOI":"10.2112\/SI83-104.1","article-title":"Classification method of marine tourism resource of least square support vector machines based on particle swarm algorithm","volume":"83","author":"Xu","year":"2018","journal-title":"J Coastal Res."},{"key":"10.3233\/JCM-226957_ref6","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.renene.2020.07.106","article-title":"Experimental investigation on the heating and cooling performance of a solar air composite heat source heat pump","volume":"161","author":"Zhang","year":"2020","journal-title":"Renew Energ."},{"issue":"2","key":"10.3233\/JCM-226957_ref7","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/s11630-020-1163-z","article-title":"Dynamic simulation of a novel solar polygeneration system for heat, power and fresh water production based on solar thermal power tower plant","volume":"29","author":"Li","year":"2020","journal-title":"J Therm Sci."},{"key":"10.3233\/JCM-226957_ref8","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1016\/j.egyr.2021.03.006","article-title":"Reconciling thermal performance and power-saving performance of counter-flow spray heating towers","volume":"7","author":"Cui","year":"2021","journal-title":"Energy Rep."},{"issue":"9","key":"10.3233\/JCM-226957_ref9","doi-asserted-by":"crossref","first-page":"5668","DOI":"10.1016\/j.ijhydene.2019.03.061","article-title":"Development and performance analysis of a new solar tower and high temperature steam electrolyzer hybrid integrated plant","volume":"45","author":"Yilmaz","year":"2020","journal-title":"Int J Hydrogen Energ."},{"key":"10.3233\/JCM-226957_ref10","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.renene.2021.01.145","article-title":"Research on the passive double effect tower based on time misplaced exergy","volume":"170","author":"Song","year":"2021","journal-title":"Renew Energ."},{"issue":"6","key":"10.3233\/JCM-226957_ref11","doi-asserted-by":"crossref","first-page":"2125","DOI":"10.1016\/j.net.2023.02.029","article-title":"Multi-objective optimization of printed circuit heat exchanger with airfoil fins based on the improved PSO-BP neural network and the NSGA-II algorithm","volume":"55","author":"Wang","year":"2023","journal-title":"Nucl Eng Technol."},{"issue":"23","key":"10.3233\/JCM-226957_ref12","first-page":"5180","article-title":"On the potential of the particle swarm algorithm for the optimization of detailed kinetic mechanisms","volume":"125","author":"El Rassy","year":"2021","journal-title":"Comparison with the genetic algorithm. J Phys Chem A."},{"key":"10.3233\/JCM-226957_ref13","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.ress.2018.09.005","article-title":"An improved particle swarm optimization algorithm for reliability-redundancy allocation problem with mixed redundancy strategy and heterogeneous components","volume":"181","author":"Ouyang","year":"2019","journal-title":"Reliab Eng Syst Safe."},{"key":"10.3233\/JCM-226957_ref14","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1016\/j.egyr.2022.10.199","article-title":"Optimization dispatching of isolated island microgrid based on improved particle swarm optimization algorithm","volume":"8","author":"Zhang","year":"2022","journal-title":"Energy Rep."},{"issue":"38","key":"10.3233\/JCM-226957_ref15","doi-asserted-by":"crossref","first-page":"17885","DOI":"10.1021\/acs.iecr.9b01854","article-title":"Hybrid model-based feedforward and fractional-order feedback control design for the benchmark refrigeration system","volume":"58","author":"Yuan","year":"2019","journal-title":"Ind Eng Chem Res."},{"issue":"43","key":"10.3233\/JCM-226957_ref16","doi-asserted-by":"crossref","first-page":"14502","DOI":"10.1021\/acssuschemeng.1c04971","article-title":"Dicationic-type quaternary ammonium salts as candidates of desiccants for an air-conditioning system","volume":"9","author":"Itoh","year":"2021","journal-title":"ACS Sustainable Chemistry & Engineering."},{"key":"10.3233\/JCM-226957_ref17","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.solener.2019.11.056","article-title":"Experimental study of a solar adsorption refrigeration system integrated with a compound parabolic concentrator based on an enhanced mass transfer cycle in Kunming, China","volume":"195","author":"Zhao","year":"2020","journal-title":"Sol Energy."},{"key":"10.3233\/JCM-226957_ref18","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.atmosenv.2019.02.002","article-title":"Neural network predictions of pollutant emissions from open burning of crop residues: Application to air quality forecasts in southern China","volume":"204","author":"Feng","year":"2019","journal-title":"Atmos Environ."},{"issue":"38","key":"10.3233\/JCM-226957_ref19","doi-asserted-by":"crossref","first-page":"20065","DOI":"10.1016\/j.ijhydene.2021.03.132","article-title":"Modeling the SOFC by BP neural network algorithm","volume":"46","author":"Song","year":"2021","journal-title":"International Journal of Hydrogen Energy."},{"key":"10.3233\/JCM-226957_ref20","doi-asserted-by":"crossref","first-page":"1750","DOI":"10.1016\/j.energy.2017.10.130","article-title":"A MINLP model of optimal scheduling for a district heating and cooling system: A case study of an energy station in Tianjin","volume":"141","author":"Deng","year":"2018","journal-title":"Energy."},{"issue":"1","key":"10.3233\/JCM-226957_ref21","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1021\/acs.iecr.8b04821","article-title":"Hybrid strategy integrating variable selection and a neural network for fluid catalytic cracking modeling","volume":"58","author":"Long","year":"2019","journal-title":"Ind Eng Chem Res."},{"issue":"13","key":"10.3233\/JCM-226957_ref22","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1049\/iet-map.2019.1136","article-title":"Research on evaporation duct height prediction based on back propagation neural network","volume":"14","author":"Zhao","year":"2020","journal-title":"IET Microw Antenna P."},{"key":"10.3233\/JCM-226957_ref23","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1016\/j.energy.2018.12.208","article-title":"Short term electric load forecasting model and its verification for process industrial enterprises based on hybrid GA-PSO-BPNN algorithm\u2013A case study of papermaking process","volume":"170","author":"Hu","year":"2019","journal-title":"Energy."},{"key":"10.3233\/JCM-226957_ref24","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.anucene.2019.06.034","article-title":"Predictive control modeling of ADS\u2019s MEBT using BPNN to reduce the impact of noise on the control system","volume":"132","author":"Yang","year":"2019","journal-title":"Ann Nucl Energy."},{"key":"10.3233\/JCM-226957_ref25","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/j.energy.2018.01.177","article-title":"Hourly day-ahead solar irradiance prediction using weather forecasts by LSTM","volume":"148","author":"Qing","year":"2018","journal-title":"Energy."},{"key":"10.3233\/JCM-226957_ref26","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.solener.2020.10.068","article-title":"An autonomous solar driven adsorption cooling system","volume":"211","author":"Robbins","year":"2020","journal-title":"Sol Energy."}],"container-title":["Journal of Computational Methods in Sciences and Engineering"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/JCM-226957","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:07:06Z","timestamp":1776809226000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/JCM-226957"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,15]]},"references-count":26,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3233\/jcm-226957","relation":{},"ISSN":["1472-7978","1875-8983"],"issn-type":[{"value":"1472-7978","type":"print"},{"value":"1875-8983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,15]]}}}