{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:45:10Z","timestamp":1776811510668,"version":"3.51.2"},"reference-count":27,"publisher":"European Society of Computational Methods in Sciences and Engineering","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"published-print":{"date-parts":[[2022,7,8]]},"abstract":"<jats:p>Centralized photovoltaic power station is an important part of building a new power system, whose power generation unit is the main equipment of the photovoltaic power station. Therefore, it is the basis of analyzing the harmonic characteristics of photovoltaic power generation to study the harmonic generation mechanism and influencing factors of power generation units and establish the harmonic equivalent model of photovoltaic power generation units. In this paper, firstly, the harmonic generation mechanism is analyzed from the aspects of sinusoidal pulse width modulation (SPWM) and dead time of inverter. Secondly, the correlation analysis of influencing factors of output power of photovoltaic power generation unit is carried out, and then the influence of output power on harmonics is analyzed. Thirdly, the harmonic characteristic model of photovoltaic power generation unit based on actual photovoltaic power station and influencing factors is constructed. Finally, the theoretical simulation of SPWM modulation and dead time is verified and analyzed, and the simulation results of harmonic characteristics are compared with the measured data. The results show that the harmonic characteristic of the centralized photovoltaic power station is mainly to generate high-frequency odd-order harmonics, which will generate extra high-frequency even-order harmonics when the irradiation is too high or too low, and cause interharmonics when the irradiance fluctuates on the DC side of the inverter.<\/jats:p>","DOI":"10.3233\/jcm226035","type":"journal-article","created":{"date-parts":[[2022,3,29]],"date-time":"2022-03-29T14:08:54Z","timestamp":1648562934000},"page":"1235-1250","source":"Crossref","is-referenced-by-count":2,"title":["Harmonic characteristics of power generation unit of centralized photovoltaic power station connected to Tibet power grid"],"prefix":"10.66113","volume":"22","author":[{"given":"Yilin","family":"Zhao","sequence":"first","affiliation":[{"name":"School of Water Conservancy and Civil Engineering, Xizang Agriculture and Animal Husbandry College, Nyingchi, Xizang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoyan","family":"Jiang","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Xizang Agriculture and Animal Husbandry College, Nyingchi, Xizang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaobing","family":"Li","sequence":"additional","affiliation":[{"name":"Shannan Power Supply Company, State Grid Tibet Power Co., Ltd., Xizang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pan","family":"Gao","sequence":"additional","affiliation":[{"name":"Tibet Shannan Naidong Xiehe Solar Power Generation Co., Ltd., Xizang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanglu","family":"Shao","sequence":"additional","affiliation":[{"name":"Concord New Energy Group Limited, Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"55691","reference":[{"issue":"9","key":"10.3233\/JCM226035_ref1","first-page":"3072","article-title":"Key technology of power equipment operation and maintenance for new power system and its application prospect","volume":"47","author":"Sheng","year":"2021","journal-title":"High Voltage Technol."},{"issue":"4","key":"10.3233\/JCM226035_ref3","first-page":"811","article-title":"Influence analysis of parallel interaction of single stage grid-connected multi-inverter photovoltaic system","volume":"55","author":"Chen","year":"2020","journal-title":"J Southwest Jiaotong Univ."},{"issue":"7","key":"10.3233\/JCM226035_ref4","first-page":"107","article-title":"Impedance modeling and characteristic analysis of three-phase LCL grid-connected inverter","volume":"39","author":"Li","year":"2019","journal-title":"Power Autom Equip."},{"key":"10.3233\/JCM226035_ref5","doi-asserted-by":"crossref","first-page":"129108","DOI":"10.1109\/ACCESS.2020.3005671","article-title":"A time-domain companion-circuit newton-based methodology applied to the harmonic analysis of electrical networks with PV systems","volume":"8","author":"Godinez-Delgado","year":"2020","journal-title":"IEEE Access."},{"issue":"9","key":"10.3233\/JCM226035_ref6","first-page":"108","article-title":"Research and design of grid-connected photovoltaic inverter based on H\u221e control in weak current network","volume":"37","author":"Kang","year":"2021","journal-title":"Power Grid Clean Energy."},{"issue":"1","key":"10.3233\/JCM226035_ref7","first-page":"92","article-title":"Equivalent model of controlled source and resonance mechanism analysis of grid-connected photovoltaic inverter","volume":"41","author":"Wu","year":"2020","journal-title":"Acta Energ Sol Sin."},{"issue":"11","key":"10.3233\/JCM226035_ref8","first-page":"1679","article-title":"Research on control strategy of photovoltaic inverter in high harmonic power grid","volume":"37","author":"Huo","year":"2019","journal-title":"Renewable Energy."},{"issue":"5","key":"10.3233\/JCM226035_ref9","doi-asserted-by":"crossref","first-page":"3798","DOI":"10.1109\/TIE.2019.2921278","article-title":"Solar PV energy generation system interfaced to three phase grid with improved power quality","volume":"67","author":"Singh","year":"2020","journal-title":"IEEE Trans Ind Electr."},{"issue":"5","key":"10.3233\/JCM226035_ref10","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1109\/JPHOTOV.2021.3093047","article-title":"Design and real-time implementation of cascaded model reference adaptive controllers for a three-phase grid-connected PV system","volume":"11","author":"Bhunia","year":"2021","journal-title":"IEEE J Photovoltaics."},{"issue":"8","key":"10.3233\/JCM226035_ref11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TASC.2021.3094446","article-title":"An advanced control scheme for voltage source inverter based grid-tied PV systems","volume":"31","author":"Jahan","year":"2021","journal-title":"IEEE Trans Appl Supercond."},{"key":"10.3233\/JCM226035_ref12","doi-asserted-by":"crossref","first-page":"178360","DOI":"10.1109\/ACCESS.2020.3027784","article-title":"Power quality improvement in solar fed cascaded multilevel inverter with output voltage regulation techniques","volume":"8","author":"Stonier","year":"2020","journal-title":"IEEE Access."},{"issue":"2","key":"10.3233\/JCM226035_ref13","doi-asserted-by":"crossref","first-page":"2859","DOI":"10.1109\/JSYST.2020.2985164","article-title":"An improved adaptive control strategy in grid-tied PV system with active power filter for power quality enhancement","volume":"15","author":"Babu","year":"2021","journal-title":"IEEE Syst J."},{"issue":"1","key":"10.3233\/JCM226035_ref14","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1109\/TEC.2020.3006552","article-title":"An improved multilevel inverter for single-phase transformerless PV system","volume":"36","author":"Faraji","year":"2021","journal-title":"IEEE Trans Energy Convers."},{"issue":"6","key":"10.3233\/JCM226035_ref15","doi-asserted-by":"crossref","first-page":"7077","DOI":"10.1109\/TIA.2020.3020931","article-title":"Three-phase four-wire PV system for grid interconnection at weak grid conditions","volume":"56","author":"Naqvi","year":"2020","journal-title":"IEEE Trans Ind Appl."},{"issue":"1","key":"10.3233\/JCM226035_ref16","first-page":"101","article-title":"Harmonic resonance suppression strategy for photovoltaic grid-connected system considering the influence of distributed capacitance of transmission line","volume":"41","author":"Shen","year":"2020","journal-title":"Acta Energ Sol Sin."},{"issue":"9","key":"10.3233\/JCM226035_ref17","first-page":"2561","article-title":"Research on harmonic resonance suppression strategy of grid-connected system based on long transmission lines","volume":"40","author":"Zhang","year":"2019","journal-title":"Acta Energ Sin."},{"issue":"12","key":"10.3233\/JCM226035_ref18","first-page":"40","article-title":"Harmonic and voltage control of high permeability distributed photovoltaic system","volume":"48","author":"Zou","year":"2020","journal-title":"Smart Electr Power."},{"issue":"2","key":"10.3233\/JCM226035_ref19","first-page":"1","article-title":"Research on harmonic comprehensive characteristics of feeder network with multiple power sources","volume":"48","author":"He","year":"2020","journal-title":"Intell Electr Power."},{"issue":"1","key":"10.3233\/JCM226035_ref20","first-page":"71","article-title":"Output characteristics analysis and harmonic source modeling of grid-connected photovoltaic inverter","volume":"42","author":"Sun","year":"2020","journal-title":"Electr Autom."},{"issue":"5","key":"10.3233\/JCM226035_ref21","doi-asserted-by":"crossref","first-page":"2978","DOI":"10.1109\/TPWRD.2020.3031375","article-title":"Impact assessment of high-frequency distortions produced by PV inverters","volume":"36","author":"Torquato","year":"2021","journal-title":"IEEE Trans Power Delivery."},{"issue":"8","key":"10.3233\/JCM226035_ref22","first-page":"192","article-title":"Preliminary study on multiple constraints of photovoltaic access traction power supply system","volume":"41","author":"Deng","year":"2020","journal-title":"Acta Energ Sol Sin."},{"key":"10.3233\/JCM226035_ref23","unstructured":"Deng WL, Dai CH, Chen WR. Application and key problems analysis of photovoltaic in AC\/DC traction power supply system under the background of rail transit energy Internet. Proc CSEE. 2019; 39(19): 5692-5702+5897."},{"issue":"10","key":"10.3233\/JCM226035_ref24","first-page":"3663","article-title":"Review of photovoltaic power station access to rail transit traction power supply system","volume":"43","author":"Chen","year":"2019","journal-title":"Power Grid Technol."},{"issue":"4","key":"10.3233\/JCM226035_ref25","first-page":"181","article-title":"Harmonic interaction and adaptability analysis of photovoltaic access traction power supply system","volume":"39","author":"Deng","year":"2019","journal-title":"Electr Power Autom Equip."},{"issue":"9","key":"10.3233\/JCM226035_ref27","first-page":"161","article-title":"Modeling of inverter dead zone and its influence on large-scale photovoltaic grid-connected system","volume":"41","author":"Zhang","year":"2020","journal-title":"Acta Energ Sol Sin."},{"issue":"5","key":"10.3233\/JCM226035_ref28","first-page":"117","article-title":"Effect of Dead zone on output error of voltage inverter and its compensation","volume":"22","author":"Liu","year":"2007","journal-title":"Trans China Electrotech Soc."},{"issue":"2","key":"10.3233\/JCM226035_ref30","first-page":"403","article-title":"Influence of meteorological factors on photovoltaic power generation based on PRINCIPAL component regression analysis","volume":"42","author":"Cheng","year":"2021","journal-title":"Acta Energ Sol Sin."}],"container-title":["Journal of Computational Methods in Sciences and Engineering"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/JCM226035","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:06:26Z","timestamp":1776809186000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/JCM226035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,8]]},"references-count":27,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3233\/jcm226035","relation":{},"ISSN":["1472-7978","1875-8983"],"issn-type":[{"value":"1472-7978","type":"print"},{"value":"1875-8983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,8]]}}}