{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T06:34:20Z","timestamp":1777703660877,"version":"3.51.4"},"reference-count":20,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2017,3,29]],"date-time":"2017-03-29T00:00:00Z","timestamp":1490745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"published-print":{"date-parts":[[2017,3,29]]},"abstract":"<jats:p>The traditional signal processing algorithms suffer from large execution delay for real time issues, therefore implementation of high speed algorithms is needed. The present work aims to implement multiplier less Savitzky Golay smoothing filter (SGSF) based on distributed arithmetic (DA) for pre-processing of Electro-oculographic (EOG) signals such that speed is increased along with reduction in chip area. The filter used should be efficient enough to remove the artifacts along with least deformation from the actual signal. Savitzky-Golay (SG) filter is widely employed in biomedical signal analysis but its fast and efficient implementation is not proposed yet for EOG analysis. SGSF is selected so that disease diagnosis using saccade detection of EOG signal can be done accurately. The efficiency of proposed filter is tested in terms of signal-to-signal-plus-noise ratio (SSNR) and real time computations. It is observed from the analysis that DA based architecture increases the processing speed, reduces the chip area and original features of filtered signal are preserved.<\/jats:p>","DOI":"10.3233\/jifs-169228","type":"journal-article","created":{"date-parts":[[2017,3,31]],"date-time":"2017-03-31T18:21:18Z","timestamp":1490984478000},"page":"2857-2862","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":8,"title":["Hardware efficient denoising system for real EOG signal processing"],"prefix":"10.1177","volume":"32","author":[{"given":"Shivangi","family":"Agarwal","sequence":"first","affiliation":[{"name":"ICE Division, NSIT, Sec-3, Dwarka, New Delhi, University of Delhi, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vijander","family":"Singh","sequence":"additional","affiliation":[{"name":"ICE Division, NSIT, Sec-3, Dwarka, New Delhi, University of Delhi, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Asha","family":"Rani","sequence":"additional","affiliation":[{"name":"ICE Division, NSIT, Sec-3, Dwarka, New Delhi, University of Delhi, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.P.","family":"Mittal","sequence":"additional","affiliation":[{"name":"ICE Division, NSIT, Sec-3, Dwarka, New Delhi, University of Delhi, Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2017,3,29]]},"reference":[{"issue":"1","key":"e_1_3_1_2_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1475-925X-12-110","article-title":"Algorithm for automatic analysis of electro-oculographic data","volume":"12","author":"Pettersson K.","year":"2013","unstructured":"PetterssonK., JagadeesanS., LukanderK., HeneliusA., H\u00e6ggstr\u00f6mE. and M\u00fcllerK., Algorithm for automatic analysis of electro-oculographic data, Biomedical Engineering Online12(1) (2013), 1.","journal-title":"Biomedical Engineering Online"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2015.01.005"},{"issue":"6","key":"e_1_3_1_4_2","doi-asserted-by":"crossref","first-page":"1440","DOI":"10.1109\/TIM.2013.2287803","article-title":"Entropy index in quantitative EEG measurement for diagnosis accuracy","volume":"63","author":"Lay-Ekuakille A.","year":"2014","unstructured":"Lay-EkuakilleA., VergalloP., GriffoG., ConversanoF., CasciaroS., Urooj...S. and TrabaccaA., Entropy index in quantitative EEG measurement for diagnosis accuracy, IEEE Transactions on Instrumentation and Measurement63(6) (2014), 1440\u20131450.","journal-title":"IEEE Transactions on Instrumentation and Measurement"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.3233\/IFS-151564"},{"key":"e_1_3_1_6_2","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/978-3-319-28658-7_21","volume-title":"Advances in Signal Processing and Intelligent Recognition Systems","author":"Baijal S.","year":"2016","unstructured":"BaijalS., SinghS., RaniA. and AgarwalS., Performance Evaluation of S-Golay and MA Filter on the Basis of White and Flicker Noise. In Advances in Signal Processing and Intelligent Recognition Systems (pp. 245\u2013255). Springer International Publishing (2016)."},{"issue":"5","key":"e_1_3_1_7_2","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/0010-4825(86)90003-X","article-title":"The effect of digital lowpass filters on the maximum velocity of saccadic eye movements","volume":"16","author":"Juhola M.","year":"1986","unstructured":"JuholaM., The effect of digital lowpass filters on the maximum velocity of saccadic eye movements, Computers in Biology and Medicine16(5) (1986), 361\u2013370.","journal-title":"Computers in Biology and Medicine"},{"issue":"406","key":"e_1_3_1_8_2","doi-asserted-by":"crossref","first-page":"231","DOI":"10.3109\/00016488309123040","article-title":"Effect of filtering in the computer analysis of saccades","volume":"96","author":"Jantti V.","year":"1983","unstructured":"JanttiV., Pyykk\u00f6I., JuholaM., IgnatiusJ., \u00c5HanssonG. and HenrikssonN.G., Effect of filtering in the computer analysis of saccades, Acta Oto-Laryngologica96(sup406) (1983), 231\u2013234.","journal-title":"Acta Oto-Laryngologica"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac60214a047"},{"issue":"4","key":"e_1_3_1_10_2","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1109\/MSP.2011.941097","article-title":"What is a Savitzky-Golay filter?[lecture notes]","volume":"28","author":"Schafer R.W.","year":"2011","unstructured":"SchaferR.W., What is a Savitzky-Golay filter?[lecture notes], IEEE Signal Processing Magazine28(4) (2011), 111\u2013117.","journal-title":"IEEE Signal Processing Magazine"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2014.11.057"},{"key":"e_1_3_1_12_2","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/978-3-319-02309-0_24","volume-title":"Man-Machine Interactions 3","author":"Czabanski R.","year":"2014","unstructured":"CzabanskiR., PanderT. and PrzybylaT., Fuzzy approach to saccades detection in optokinetic nystagmus. In Man-Machine Interactions 3 (pp. 231\u2013238). Springer International Publishing (2014)."},{"key":"e_1_3_1_13_2","first-page":"1","article-title":"Automatic electrooculogram classification for microcontroller based interface design","author":"Trikha M.","year":"2007","unstructured":"TrikhaM., BhandariA. and GandhiT., Automatic electrooculogram classification for microcontroller based interface design. In Proceedings of the IEEE systems and information engineering design symposium (pp. 1\u20136) (2007, April).","journal-title":"Proceedings of the IEEE systems and information engineering design symposium"},{"issue":"3","key":"e_1_3_1_14_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10916-015-0404-2","article-title":"Performance Evaluation and Implementation of FPGA Based SGSF in Smart Diagnostic Applications","volume":"40","author":"Agarwal S.","year":"2016","unstructured":"AgarwalS., RaniA., SinghV. and MittalA.P., Performance Evaluation and Implementation of FPGA Based SGSF in Smart Diagnostic Applications, Journal of Medical Systems40(3) (2016), 1\u201315.","journal-title":"Journal of Medical Systems"},{"issue":"2","key":"e_1_3_1_15_2","first-page":"179","article-title":"Efficient Implementation and Design of a New Single-Channel Electrooculography-Based Human-Machine Interface System","volume":"62","author":"Wu J.F.","year":"2015","unstructured":"WuJ.F., AngA.M.S., TsuiK.M., WuH.C., HungY.S., Hu...Y. and ZhangZ.G., Efficient Implementation and Design of a New Single-Channel Electrooculography-Based Human-Machine Interface System, IEEE Transactions on Circuits and Systems II: Express Briefs62(2) (2015), 179\u2013183.","journal-title":"IEEE Transactions on Circuits and Systems II: Express Briefs"},{"key":"e_1_3_1_16_2","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.vlsi.2016.01.006","article-title":"A high-performance VLSI architecture for reconfigurable FIR using distributed arithmetic","volume":"54","author":"Mohanty B.K.","year":"2016","unstructured":"MohantyB.K., MeherP.K., SinghalS.K. and SwamyM.N.S., A high-performance VLSI architecture for reconfigurable FIR using distributed arithmetic, Integration, the VLSI Journal54 (2016), 37\u201346.","journal-title":"Integration, the VLSI Journal"},{"issue":"3","key":"e_1_3_1_17_2","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1109\/53.29648","article-title":"Applications of distributed arithmetic to digital signal processing: A tutorial review","volume":"6","author":"White S.A.","year":"1989","unstructured":"WhiteS.A., Applications of distributed arithmetic to digital signal processing: A tutorial review, IEEE ASSP Magazine6(3) (1989), 4\u201319.","journal-title":"IEEE ASSP Magazine"},{"issue":"2","key":"e_1_3_1_18_2","first-page":"185","article-title":"Multiplierless FIR Filter Implementation on FPGA","volume":"2","author":"Badave S.M.","year":"2012","unstructured":"BadaveS.M. and BhalchandraA.S., Multiplierless FIR Filter Implementation on FPGA, International Journal of Information and Electronics Engineering2(2) (2012), 185.","journal-title":"International Journal of Information and Electronics Engineering"},{"key":"e_1_3_1_19_2","unstructured":"Xilinx UG230 Spartan-3E FPGA Starter Kit Board User Guide http:\/\/www.xilinx.com\/support\/documentation\/boardsandkits\/ug230.pdf"},{"key":"e_1_3_1_20_2","unstructured":"MIT-BIH Polysomnographic Database http:\/\/physionet.org\/physiobank\/database\/slpdb\/"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2012.2217494"}],"container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-169228","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.3233\/JIFS-169228","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-169228","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T09:39:15Z","timestamp":1777455555000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.3233\/JIFS-169228"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,29]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,3,29]]}},"alternative-id":["10.3233\/JIFS-169228"],"URL":"https:\/\/doi.org\/10.3233\/jifs-169228","relation":{},"ISSN":["1064-1246","1875-8967"],"issn-type":[{"value":"1064-1246","type":"print"},{"value":"1875-8967","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,29]]}}}